Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Chinese Journal of Ultrasonography ; (12): 766-770, 2018.
Article in Chinese | WPRIM | ID: wpr-707720

ABSTRACT

Objective To evaluate the effectiveness of spatio-temporal image correlation with M-mode display ( STIC-M ) in monitoring fetal left ventricular systolic function in fetuses with congenital heart disease(CHD) . Methods Five hundred and thirty-six normal fetuses and 34 fetuses with CHD( 29 without hydrops and 5 with hydrops) were involved in the study . Left ventricular fractional shortening ( LVFS) was measured using STIC-M . The data of normal fetuses was used to construct reference ranges of LVFS for assessment of fetuses with CHD . Results The LVFS of the normal fetuses [ range :26 .8% - 42 .9% , mean :( 34 .9 ± 4 .1) % ] was negatively correlated with gestational age ( r = - 0 .16 , P < 0 .001) . Compared with the normal controls ,LVFS was significantly decreased in CHD fetuses with hydrops ( P < 0 .001) . However ,there was no significant difference in LVFS between normal controls and CHD fetuses without hydrops ( P > 0 .05) . Conclusions STIC-M is a new method that can be used to measure LVFS to evaluate fetal ventricular systolic function . The fetal ventricular contractile function of CHD fetuses without hydrops may not be damaged or is in compensation stage . The fetuses with cardiac hydrops generally become lower .

2.
China Modern Doctor ; (36): 54-56, 2015.
Article in Chinese | WPRIM | ID: wpr-1037661

ABSTRACT

Objective To investigate the factors of term pregnancy fetal distress at term pregnancy and intervention midwifery cesarean section and vaginal fetal distress. Methods All 104 cases of full-term pregnancy with maternal fetal distress in labor were random divided into observation group and control group from our hospital from October 2012-October 2013, each group had 52 cases. Mothers in the control group were given vaginal midwifery, maternal in the observation group were used cesarean section, fetal distress factors and maternal and neonatal outcomes of two groups were compared and analyzed. Results Fetal distress factor (placenta, umbilical cord factors, maternal factors, fetal factors or amniotic fluid, etc.) of two groups were compared, the difference was not statistically significant (P>0.05). The inci dence of postpartum hemorrhage, neonatal asphyxia, hypoxic ischemic encephalopathy, fetal growth restric-tion,puerperal infection and hypoproteinemia of the observation group were 5.77%,5.77%, 3.85%,1.92%, 11.54%,9.62%,compared with 9.62%, 7.69%, 5.77%, 1.92%, 7.69%, 5.77%in the control group,the difference was not statis-tically significant (P>0.05). Single factor factors Logistic regression analysis results showed that the umbilical cord and placenta, fetal and maternal,amniotic fluid dung are independent risk factors of fetal distress. Multiple factors Logistic regression analysis results showed that fetal and maternal,amniotic fluid dung are independent risk factors of fetal dis-tress. neonatal deaths of two groups did not occur. Conclusion Vaginal delivery applications and cesarean surgery in treatment of fetal distress of full-term pregnancy can get better maternal and neonatal outcomes, should be based on the specific circumstances of women to choose the appropriate mode of delivery.

3.
China Modern Doctor ; (36): 55-58, 2015.
Article in Chinese | WPRIM | ID: wpr-1037805

ABSTRACT

Objective To explore the pulse oxygen saturation instrument in the application of vaginal delivery newborn, and analyze the pulse oxygen saturation in the clinical application value of vaginal delivery newborn. Methods From May 2012 to May 2013 in our hospital, 100 cases was born of the gestational age between 37 weeks to 42 weeks of vaginal delivery term newborns were randomly selected, and randomly divided into two groups in digital method: ob-servation group and control group, 50 cases in each group, after birth, the observation group with pulse oxygen satu-ration meter records the pulse of the fetus within 1 h each time values,and blood oxygen saturation, the control group was using Apgar score record the pulse of the fetus within 1 h each time values, and blood oxygen saturation, then put the two methods respectively recorded data entry into SPSS19.0 statistical software for analysis processing, analysis and comparison of pulse oxygen saturation and Apgar score in vaginal delivery was how to apply in the newborn and appli-cation value. Results Neonatal pulse oxygen saturation in observation group 1 min-monitoring value, 5 min-the moni-toring value of 10 min-monitoring value, 30 min-monitoring values were significantly higher than that of control group, significant difference was found in two groups, with statistical significance(P<0.05); Newborns in observation group 60 min-pulse oxygen saturation monitoring values similar to the control group, no significant differences between the two groups, no statistically significant (P>0.05);Neonatal pulse monitoring value in observation group, 1 min value, pulse pulse value when the 5 min,when 10 min pulse value, pulse value when 30 min, when 60 min pulse value were significantly higher than that of control group, significant difference, the two groups have statistical significance (P<0.05). Conclusion Pulse oxygen saturation meter compared with traditional Apgar score detection method, pulse oxy-gen saturation meter advantage in the application of vaginal delivery neonate, and reliability is extremely strong, ap-plication prospect, is worthy of popularization and application in clinical work.

4.
Chinese Journal of Ultrasonography ; (12): 237-241, 2011.
Article in Chinese | WPRIM | ID: wpr-414102

ABSTRACT

Objective To establish the reference ranges of the spatial angles among cardiac chambers and great vessels in second and third trimester fetuses measured by spatiotemporal image correlation (STIC).Methods Volume images of 352 normal fetuses from 20 to 38 weeks of gestation were recruited in the study.An off-line analysis of acquired volume datasets was carried out with multiplanar mode.Parameters measured included angles between:(1) the 4-chamber view and the left ventricular long axis view; (2) the left ventricular long axis view and main pulmonary artery; and (3) the ductal arch and aortic arch.The relationships between above-mentioned angles and gestational age were assessed by correlation and regression analysis.Results The angle between the 4-chamber view and the left ventricular long axis view (range:55.7° - 35.7°,mean:45.7° ± 5.12°) was uncorrelated with gestational age (r = 0.03,P = 0.51).In contrast,the angle between the left ventricular long axis view and main pulmonary artery,and the angle between the ductal arch and aortic arch were correlated with gestational age (P < 0.001),and the correlation coefficient was - 0.53 and 0.57 respectively.The best-fit exponential curve regression equations of the angle between the left ventricular long axis view and main pulmonary artery was:Y = 154- 4.24X +0.05X2 ,and the angle between the ductal arch and aortic arch was:Y = - 20.8 + 2.65X - 0.37X2.Conclusions The angles among cardiac chambers and great arteries of fetuses from 20 to 38 weeks of gestation can be quantitatively measured by STIC.The reference ranges provide a reliable quantitative standard to estimate the spatial relationships of the cardiac large arteries of fetuses,which may be clinically useful in prenatal screening congenital heart disease.

5.
Chinese Journal of Neuroanatomy ; (6): 569-575, 2005.
Article in Chinese | WPRIM | ID: wpr-409737

ABSTRACT

The aim of this study is to elucidate the protective and anti-apoptotic effects of insulin-like growth factor 1 ( IGF-1 ) against β-amyloid (Aβ) and investigate the effect of IGF-1 on Aβ-induced tau phosphorylation. Cell viability was measured using the MTT (3-(4,5-dimethylthiazolyl-2 )-2,5-diphenyltetrazolium bromide) assay, early apoptosis and late apoptosis/necrosis were analyzed by flow cytometry using Annexin V-FITC and propidium iodide (PI) double staining, and morphology was examined by Hoechst 33342 staining. Tau phosphorylation was detected using AT8 immunostaining. Preincubation of cultured rat hippocampal neurons with IGF-1 for 24 h prevented cytotoxicity induced by Aβ25-35 for 48 h. The MTT value significantly increased from 54.51% to 61.8% of the control group, and the percentage of Hoechst 33342-positive cells decreased from 30.77% to 22.81%. Incubation with Aβ25-35 for 48 h caused a marked increase in the percentages of Annexin V-FITC single-labeled cells (Annexin V +/PI-) and Annexin V/PI double-stained cells (Annexin V +/PI + ) (3.41% and 19.47% , respectively), which were significantly decreased by pretreatment with 100 ng/ml of IGF-1 for 24 h (to 2.98% and 15.16% , respectively). Aβ25-35 treatment increased tau phosphorylation and AT8 positive cells were 41.84%. This effect could be inhibited by different concentrations of IGF-1. Our findings showed that IGF-1 protected against Aβ-induced cytotoxicity, decreased the percentage of early and late apoptosis/necrosis cells, and inhibited tau phosphorylation, which may be the cellular mechanisms for its neuroprotective action.

SELECTION OF CITATIONS
SEARCH DETAIL