Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Drug Evaluation Research ; (6): 1576-1580, 2017.
Article in Chinese | WPRIM | ID: wpr-664626

ABSTRACT

Objective To establish a UPLC-MS/MS method for determination of 10 anti-rheumatic constituents illegally added in Chinese traditional medicine and health products preparation.Methods The column was ACQUITY UPLC BEHC18 (50 mm× 2.1 mm,1.7 μm),The mobile phase was acetonitrile-Ammonium acetate solution (containing 0.1% Acetic acid) with gradient elution at a flow rate of 0.3 mL/min.The ion source was electrospray ionization (ESI),Multiple-reaction monitoring (MRM) was performed to identify and quantify 10 anti-rheumatic constituents.Results 10 linear calibration curves were obtained with r ≥ 0.996 1.The recoveries were determinated at three concentration and ranged from 92.5% to 101.8%.The precision of the method was shown by RSD (n =5) ranged from 0.9% to 3.1%.The ranges of limit of detection were from 0.001 5 to 0.018 μg,and quantitation were from 0.004 5 to 0.55 μg.The illegally added chemicals were detected with 10 batches of 27 batches of samples.Conclusion The method were simple,sensitivity,accurate,and can be used to detect Anti-rheumatic constituents illegally added in Chinese traditional medicine and health products.