ABSTRACT
To evaluate whether a new biphasic cement composed of calcium sulfate and beta tricalcium phosphate with zeta potential control could induce or lead to bone neoformation in critical defects. METHODS: A critical defect of diameter 8 mm was made in the calvaria of forty male Wistar rats. In the Test Group (n = 20), the defects were filled with cement. In the Control Group (n = 20), the defect was not filled and only coagulum was present. The animals were sacrificed 7, 14, 21 and 42 days after the operation. Calvaria specimens were subjected to microtomography and were then prepared for histological analysis. The analyses included morphological assessment on the histopathology of the repair; comparative morphometric evaluation of the area of formation of bone trabeculae between the groups; and histochemical staining by means of tartrate-resistant phosphatase (TRAP) in order to identify osteoclasts. RESULTS: Microtomographic images of the defects filled by the cement did not show any decrease in area over the course of postoperative evolution. In the Test Group, the material continued to present a foreign-body response until the last observational periods. Histomorphological analysis showed that there were more significant groupings of giant cells in the Test Group and greater maturity of neoformed bone in the Control Group. Exogenous material was also present. Histomorphometric analysis showed that in the Control Group, the total area of bone neoformation was significantly greater (p = 0.009) and grew progressively. The giant cells presented a positive reaction to TRAP but no osteoclasts were observed. CONCLUSION: The ceramic cement did not induce or lead to bone neoformation from the microtomographic or histological point of view.
Avaliar se um novo cimento bifásico composto por sulfato de cálcio e beta fosfato tricálcico com controle de potencial zeta poderia induzir ou conduzir a neoformação óssea em defeitos críticos. MÉTODOS: Foi feito um defeito crítico de 8 mm de diâmetro na calvária de 40 ratos Wistar machos. No grupo teste (n = 20) os defeitos foram preenchidos pelo cimento. No grupo controle (n = 20) os defeitos não foram preenchidos, permaneceu apenas o coágulo. Os animais sofreram eutanásia em 7, 14, 21 e 42 dias do pós-operatório. Espécimes da calvária foram microtomografados e posteriormente preparados para análise histológica. As análises incluíram a avaliação morfológica da histopatologia do reparo e a avaliação morfométrica da área de formação das trabéculas ósseas comparativamente entre os grupos e coloração histoquímica por meio da fosfatase tartrato-resistente (TRAP) para identificação de osteoclastos. RESULTADOS: As imagens microtomográficas dos defeitos preenchidos pelo cimento não apresentaram diminuição da área de acordo com a progressão dos períodos pós-operatórios. No grupo teste houve permanência do material e resposta corpo estranho até os últimos períodos de observação. A histomorfologia mostrou agrupamentos mais expressivos de células gigantes no grupo teste e osso neoformado mais maduro no grupo controle e comprovou a presença de material exógeno. Na histomorfometria, a área total de neoformação óssea foi significativamente maior (p = 0,009) e crescente no grupo controle. As células gigantes apresentaram expressão histoquímica positiva para TRAP e não foram observados osteoclatos. CONCLUSÃO: O cimento cerâmico não induziu ou conduziu a neoformação óssea sob o ponto de vista microtomográfico e histológico.
Subject(s)
Animals , Rats , Biocompatible Materials , Bone Regeneration , zeta Potential , Rats, WistarABSTRACT
A reconstrução de defeitos ósseos críticos é alvo de inúmeras pesquisas em cirurgia bucomaxilofacial. Tais pesquisas visam, de maneira geral, a optimização da neoformação óssea e a eliminação dos procedimentos de remoção de osso autógeno para reconstrução. Os modelos animais têm sido a metodologia mais utilizada para avaliar a eficácia de novas substâncias e biomateriais na reparação óssea. O objetivo desta pesquisa foi avaliar a influência de um flavonóide, o icariin, na reparação óssea de defeitos críticos confeccionados na calvária de ratos Wistar. Um defeito ósseo crítico circular foi confeccionado em 40 calvarias de ratos por meio de uma broca trefina de 8 mm de diâmetro sob irrigação salina constante. Ao final dos procedimentos cirúrgicos, os animais foram divididos, aleatoriamente, em grupo teste (n=20), que recebeu o icariin, na dose de 125 mg/kg de peso e grupo controle (n=20), que recebeu soro fisiológico. Ambas as substâncias foram administradas por meio de gavagem até o dia da eutanásia. Ao final de cada período observacional de 7, 14, 21 e 42 dias, 5 animais de cada grupo foram eutanasiados e as amostras da calvária foram removidas e mantidas em formol 10% por 48 horas.
As calvárias foram radiografadas e, após descalcificação, foram submetidas à avaliação histológica com coloração hematoxilina-eosina sob microscópio de luz. Os defeitos foram analisados considerando a diminuição da área do defeito na imagem radiográfica, as características de reparo ósseo e a osteogênese na região da ferida. Os resultados da análise radiográfica mostraram que a área do defeito ósseo no grupo teste foi significativamente menor que no grupo controle em todos os períodos observacionais. A avaliação histológica mostrou um aumento na neoformação óssea do grupo teste (p=0,02). A histomorfometria demonstrou osteogênese significante no grupo teste com 7 dias (p=0,021), 14 dias (p=0,014), 21 dias (p=0,021) e 42 dias (p=0,009). Foi possível concluir que o icariin sistêmico induziu uma maior neoformação óssea em defeitos críticos.
Bone critical defect reconstruction is an important target in current oral surgery research. Contemporary research has been searching for osteogenesis optimization to minimize the necessity of using autogenous bone grafts procedures. Animal models have been the widespread methodology to evaluate the effect of different new substances and biomaterials in bone healing. The aim of this study was to assess the influence of systemic daily flavonoid, icariin, in the repair of calvaria critical size defects induced in Wistar rats. A round critical size defect was performed centrally in 40 rats calvaria using an 8mm trephine under sterile saline solution irrigation. After surgery, half the animals, randomly, received by gavage daily doses of 125mg/Kg-icariin (Test Group) till the euthanasia. The other half (Control Group) received the same volume of saline solution. Five animals of each group were euthanized after 7, 14, 21 and 42 days postoperatively. The rats calvaria were removed, fixed in 10% formalin for 48 hours. Calvarias were X-rayed and after decalcification they underwent histological examination with hematoxylin eosin stain under a light microscope. Defects were analyzed considering area diminishing in X-ray image, bone healing characteristics and osteogenesis in the defect region. Results showed that bone defect area in Test Group was significant smaller in all observational periods. Histological evaluation showed an increased expression in bone trabeculae neoformation in Test Group (p=0,02). Histomorphometry demonstrated significant osteogenesis in Test Group at 7 days (p=0,021), 14 days (p=0,014), 21 days (p=0,021) and 42 days (p=0,009). It was concluded that systemic icariin induced a more expressive bone healing in critical size defects in rats.
Subject(s)
Animals , Rats , Bone Regeneration , Rats, Wistar , Skull , Wound HealingABSTRACT
PURPOSE: The objective of this study was to evaluate the influence of the Grander technology in reducing the surface tension and contact angle of a self-etch adhesive system. METHODS: Distilled water and Xeno III self-etch adhesive system (Dentsply) were modified by physical contact with the Flexible unit Grander system to revitalize water, for 48 hours, resulting in four groups: Group 1 - Xeno III under normal conditions; Group 2 - Xeno III modified by Grander; Group 3 - distilled water under normal conditions; Group 4 - distilled water system modified by the Grander system;. Surface tension and contact angle (dentin substrate and titanium plate) of the adhesive system and water in normal and Grander-modified conditions was measured with a goniometer. Data were analyzed by ANOVA and Tukey test (5%). RESULTS: Grander technology reduced the surface tension of water but not of the adhesive system Xeno III. The contact angle property of the adhesive ystem was not affected. CONCLUSION: Grander technology did not interfere with the surface tension and contact angle physical properties of the Xeno III self-etch adhesive system.
OBJETIVO: Esta pesquisa verificou os efeitos da tecnologia Grander na alteração da tensão superficial e ângulo de contato de um sistema adesivo autocondicionante. METODOLOGIA: O sistema adesivo autocondicionante Xeno III (Dentsply) e a água destilada foram modificados pelo contato físico com a unidade flexible do sistema Grander para revitalização de águas por 48 horas, resultando em 4 grupos: Grupo 1 - sistema adesivo Xeno III em condições de normalidade; Grupo 2 - sistema adesivo Xeno III modificado pelo sistema Grander; Grupo 3 - água destilada em condições de normalidade; Grupo 4 - água destilada modificada pelo sistema Grander. A tensão superficial dos líquidos foi verificada em goniômetro utilizando cinco medidas para cada gota de líquido. O ângulo de contato foi medido com o goniômetro sobre os substratos placa de titânio e dentes bovinos. Os dados foram submetidos aos testes ANOVA e Tukey (5%). RESULTADOS: Houve redução significativa da tensão superficial da água com a modificação pelo sistema Grander. Não houve redução da tensão superficial e ângulo de contato para o sistema adesivo Xeno III. CONCLUSÃO: A tecnologia Grander não interferiu com a tensão superficial e o ângulo de contato para o sistema adesivo Xeno III.