ABSTRACT
Objective:To explore the effects of the LAmbre device and mitral annulus(MA), as well as left atrium(LA) in patients with non-valvular atrial fibrillation(NVAF) after left atrial appendage closure (LAAC) using real-time-three-dimensional transesophageal echocardiography (3D TEE).Methods:Fity-six consecutive patients who underwent LAAC with the LAmbre device in Zhongshan Hospital of Fudan University from June 2019 to March 2023 were retrospectively enrolled, with no or less than moderate mitral regurgitation (MR). All patients underwent pre-operative and follow-up two-and three-dimensional transesophageal echocardiography (2D TEE, 3D TEE) at 60 days after the operation. The quantitative parameters of MA and LA were obtained by offline analysis using QLab 13.0 (Philips Healthcare, Andover, MA). Importantly, mitral annular measurements were made at seven time points throughout the cardiac cycle: early diastole, mid-diastole, late diastole, mitral valve closure, early systole, mid-systole, and late systole, which facilitates constructing the dynamic model of MA to assess the annular morphology and dynamics.Results:The values of AP diameter (APD), AL-PM diameter (ALPMD), 3D annulus circumference (3DAC), 3D annulus area (3DAA) decreased significantly compared with pre-operative values at all time points of the cardiac cycle (all P<0.05), while non-planar angle (NPA) and AH/CD were not apparently changed (all P>0.05 ). Throughout the cardiac cycle, MA showed regular changes, gradually increased in systole with the saddle shape deepened, and gradually decreased in diastole with the saddle shape shallowed.During systole, there was an increase in the rate of change of AP in MA [pre-operative (3.01±2.64)%, post-operative (3.81±3.51)%, P=0.037] after LAAC, with no significant difference in the rate of change of ALPM, 3DAC, and 3DAA.Meanwhile, we observed an evident reduction in LA minimal volume (LAVmin) [pre-operative (78.36±25.16)ml, post-operative (70.73±22.78)ml, P=0.004] and an obvious increase in LA ejection function [pre-operative (22.88±10.09)%, post-operative (31.41±12.28)%, P<0.05] during follow-up. Conclusions:3D TEE can accurately assess the impact of LAAC on the MA and LA. The LAmbre device can affect the morphology of MA, as well as the structure and function of LA, while the change of the dynamics of MA is not so prominent.
ABSTRACT
@#Transcatheter aortic valve replacement (TAVR) has seen a surge in clinical research, basic research, and innovative device development both domestically and internationally in the previous 2023. This article aims to review the progress of TAVR in the past year from the perspectives of international, and domestic research development of application. It highlights new clinical and basic research findings both domestically and internationally, the emergence of new devices and technologies, and the development and use of TAVR in China. Finally, it provides an outlook on the trajectory of TAVR development in 2024.
ABSTRACT
@#Transcatheter edge-to-edge repair (TEER) for mitral regurgitation (MR) is known as M-TEER. Its strengths include: precise targets and fewer implants; simple and clear principles for catheterization; originating from dependable medical concepts and broad applicability. Furthermore, TEER offers advantages in real-time hemodynamic and effectiveness measurement throughout the procedure over surgical edge-to-edge repair (SEER). When it comes to patients with degenerative mitral regurgitation , M-TEER should aim to deliver more optimum procedural outcomes. In functional mitral regurgitation, a modest transvalvular gradients or moderate residual shunt can be tolerated with M-TEER, which reduces the risk of problems and has no bearing on the patient's prognosis.
ABSTRACT
@#Transcatheter mitral valve edge-to-edge repair (TEER) has become an important treatment opinion for patients with severe mitral regurgitation (MR) at high risk for surgery. The devices and procedural techniques of TEER are complex and require excellent team cooperation. However, there is still a lack of standardized clinical pathways in China. Based on the latest evidence, the expert group wrote this clinical pathway to guide and optimize TEER therapy in clinical practice. It demonstrates the following key issues of clinical concern: (1) TEER team building; (2) preoperative clinical evaluation of TEER patients; (3) imaging assessment before TEER procedure; (4) standardized procedures for TEER; (5) TEER for complex MR; (6) the standard process of perioperative comprehensive management; and (7) full life-cycle rehabilitation and follow-up. This clinical pathway might be helpful to facilitate the standardized development of TEER therapy and application, and promote the improvement of management and life quality for patients with MR.
ABSTRACT
Transcatheter tricuspid valve intervention is the new frontier of interventional cardiology. The LuX-Valve is a radial force-independent orthotopic tricuspid valve replacement device developed in China. The LuX-Valve Plus transcatheter tricuspid valve replacement (TTVR) system is changed from the trans-atrial to the transjugular approach, which further reduces trauma and pulmonary complications compared with the first generation LuX-Valve. The first-in-human study has been completed at Zhongshan Hospital, Fudan University and an exploratory multicentre clinical study is underway. Echocardiography plays an important role in pre-TTVR screening, intraoperative guidance and postoperative evaluation and follow-up, especially two-dimensional transoesophageal echocardiography (2D-TEE) and three-dimensional transoesophageal echocardiography (3D-TEE). However, there is a lack of appropriate intraoperative guidance and assessment protocols. In this study, we briefly described the protocols and imaging considerations for intraoperative 2D-TEE and 3D-TEE to ensure the successful implantation of TTVR.
ABSTRACT
@#Objective To study the hemocompatibility of bioprosthetic heart valve materials respectively based on glutaraldehyde and non-glutaraldehyde treatment. Methods Fresh bovine pericardium was treated with glutaraldehyde or non-glutaraldehyde after adipose tissue was removed. To evaluate the hemocompatibility of the two bioprosthetic heart valve materials, hemolysis test, in vitro fibrinogen adsorption experiment, platelet adhesion experiment, thrombin-antithrombin complex (TAT) test, complement activation assay and ex vivo circulation experiment were performed. Results The hemolysis test results demonstrated that both of the materials showed hemolytic rates lower than 5%. The results of TAT test and complement activation assay showed no statistical differences among the two materials and the blank control group. Compared to the bioprosthetic heart valve materials with glutaraldehyde-based treatment, the materials with non-glutaraldehyde-based treatment showed significantly decreased fibrinogen adsorption, platelet adhesion and thrombosis. Conclusion Compared to the bioprosthetic heart valve materials with glutaraldehyde-based treatment, the materials with non-glutaraldehyde-based treatment show better hemocompatibility.
ABSTRACT
@#Objective To evaluate the safety and efficacy of transcatheter aortic valve replacement (TAVR) using the SAPIEN 3 system. Methods This was a prospective, multicenter, single arm study in 4 centers in China. The clinical data of 50 patients with high-risk symptomatic severe aortic stenosis who underwent TAVR using the SAPIEN 3 system from June 2017 to June 2019 were analyzed, including 27 males and 23 females aged 76.8±6.1 years. Results The Society of Thoracic Surgeon score was 6.0%±2.8%. Totally, 20.0% of patients had severe bicuspid aortic stenosis. The operation time was 41.8±16.5 min and the hospital stay time was 8.5±5.0 d. At the postoperative 30-day follow-up, no all-cause mortality occurred and the device success rate was 89.5%. Major vascular complications occurred in one (2.0%) patient, stroke in one (2.0%) patient, new pacemaker implantation in one (2.0%) patient, as well as coronary artery obstruction in one (2.0%) patient. There was no moderate or moderate/severe paravalvular leak. The aortic pressure gradient was decreased from 49.2±16.2 mm Hg before the operation to 12.4±4.6 mm Hg at the postoperative 30-day follow-up, and the valvular area was increased from 0.6±0.3 cm2 to 1.3±0.3 cm2 (P<0.01). Moreover, the New York Heart Association classification in 83.7% of the patients was improved during the follow-up. Conclusion This pre-marketing multicenter study has demonstrated the safety and effectiveness of transfemoral TAVR with the SAPIEN 3 transcatheter valve system in Chinese aortic stenosis patients at high risk for surgery.
ABSTRACT
Tricuspid regurgitation (TR) interventions are under rapid development. The K-Clip? system is the first domestic transcatheter tricuspid annuloplasty system with unique clamping procedure to achieve annular reduction.Intraoperative echocardiographic monitoring procedures for transcatheter tricuspid annuloplasty have not been reported yet in China. Thus, this review aimed to propose the standard two-dimensional and three-dimensional transesophageal echocardiographic workplanes and procedures to guide and monitor the implantation of K-Clip system based on our experience in Zhongshan Hospital, Fudan University to provide a reference point for the intraoperative echocardiographic monitoring of future transcatheter tricuspid annuloplasty devices in China.
ABSTRACT
@#Transcatheter edge-to-edge repair (TEER) originated from surgical edge-to-edge repair. MitraClip is the first mature TEER device, and the TEER based on MitraClip is far ahead of many transcatheter mitral valve repair (TMVr) technologies in terms of safety, effectiveness and popularity, so it is named separately in the latest guidelines. The TEER has the following advantages: consistent with basic medical principles, few implants, precise target, less invasive and repeatable. However, there are also some shortcomings, such as the relatively complex design of transfemoral device, target single and relatively narrow indications. At present, the main clinical data of TEER are mainly from the clinical practice of MitraClip. Based on the three-year outcomes of COAPT study, both 2020 ACC/AHA guideline and 2020 ACC expert consensus decision pathway on the management of mitral regurgitation recommend in patients with chronic heart failure with left ventricular dysfunction and severe mitral regurgitation in nonresponders to medicine treatment. Edward's PASCAL, another TEER device, has two models. Among the domestic TEER devices, the ValveClamp of Hanyu medical technology has many distinct advantages, such as simple operation, large clamping area, high clamping efficiency and no need of X-ray. DragonFly, another domestic TEER device, has also completed its feasibility study. There are five trends of TEER in the future: further expansion of indications, combination with other interventional techniques, repeatable operations, transcatheter mitral valve replacement after TEER, and continuous improvement and innovation of equipment.
ABSTRACT
Objective:To investigate the relationship between Watchman occluder and structure of mitral valve apparatus in patients with nonvalvular atrial fibrillation after left atrial appendage closure(LAAC) by transesophageal echocardiography.Methods:From January 2018 to December 2020, 29 patients [20 male, 9 female, (69.55±10.06)years old] with nonvalvular atrial fibrillation underwent LAAC in Zhongshan Hospital (implanted Watchman occluder), and all patients underwent pre-operative and follow-up two and three dimensional transesophageal echocardiography(2DTEE, 3DTEE) at 60 days after the operation. The quantitative parameters of mitral valve apparatus were obtained by offline analysis using the MVA module in QLab 13.0 (Philips Healthcare, Andover, MA), the differences between pre-operation and post-operation were compared, and the relationship between occluder compression ratio and mitral valve parameters with significant changes after operation was analyzed.Results:①The values of AL-PM diameter(AL-PM), 3D annulus circumference(3DAC), 2D annulus area(2DAA), 3D annulus area(3DAA), tenting volume(TnV), tenting area(TnA) and commissural diameter(CD) decreased significantly compared with pre-operative values(all P<0.05), while the annulus sphericity index(SPI) increased significantly ( P<0.05). ②In the quantitative mitral value parameters with significant pre- and post-operation changes, TnV was correlated with the occluder compression ratio ( r=0.403, P=0.030), but AL-PM, SPI, 3DAC, 2DAA, 3DAA, TnA, CD were not correlated with it(all P>0.05). Conclusions:3DTEE can accurately evaluate the effect of Watchman occluder on the morphology of mitral valve device. Implanting Watchman occluder in left atrial appendage can make three-dimensional mitral valve apparatus flat and decrease annulus left-right diameter and annulus area; the pre-operative TnV, the more susceptible to the occluder implantation, and TnV is correlated with the compression ratio.
ABSTRACT
@#In 2020, due to the impact of the novel coronavirus epidemic, the development of transcatheter heart valve therapy has been shown to slow down, but there are still many aspects worth noting. The indication of monoclonal antibody after transcatheter aortic valve replacement (TAVR) should be further clarified. Low surgical risk patients were included in TAVR relative indications. Mitraclip G4 was approved by CE. The indication of atrial septal occlusion after mitraclip should be further clarified. The technique of coaptation augmentation is expected to become a new method of mitral valve interventional repair. Tendyne transcatheter mitral valve was approved by European Union. Transcatheter tricuspid valve treatment equipments, TriClip and PASCAL obtained CE mark. TAVR technology is being popularized rapidly in China, and what’s more, balloon dilated valve Sapien 3 and new recyclable repositioning valve system-Venus plus have entered the domestic market. A number of mitral valve therapeutic instruments have appeared one after another, and China's first tricuspid valve lux has completed its FIM research. Finally, with the improvement of devices and technology in the future, interventional therapy of heart valve is expected to benefit more patients.
ABSTRACT
@#Mitral regurgitation (MR) is the most common heart valve disease. In recent years, the rise of interventional therapy has expanded the indications of interventional treatment for patients with MR, but the epidemiological characteristics of MR (especially the number of patients with MR requiring treatment) in China are still unclear. In this paper, we analyzed and estimated the number of MR patients in China based on three epidemiological studies in Europe and America, and referring to the patients population surveys from Zhongshan Hospital Affiliated to聽Fudan University, the Second Affiliated Hospital Zhejiang University School of Medicine and Beijing Fuwai Hospital. Our analysis estimated that about 7.5 million patients with MR need intervention in China, including about 5.5 million patients with severe MR.
ABSTRACT
@#Objective To evaluate the efficiency and safety of intraprocedural valve-in-valve deployment for treatment of aortic regurgitation following transcatheter aortic valve replacement (TAVR). Methods Consecutive patients (n=333) who diagnosed with severe aortic stenosis and underwent TAVR in Zhongshan Hospital affiliated to Fudan University from October 3rd, 2010 to April 21st, 2021 were included. There were 208 males and 125 females aged 76.0±7.0 years. There were 316 patients underwent simple TAVR (simple TAVR group) and 17 patients underwent intraprocedural valve-in-valve deployment following TAVR (valve-in-valve group). Their clinical and echocardiographic outcomes were evaluated and compared. Results There was no significant difference between the two groups of patients at postoperative 30 d and 1 year in all-cause mortality (4.4% vs. 0, P=1.000; 6.3% vs. 0, P=1.000), incidence of pacemaker implantation (10.4% vs. 17.6%, P=1.000; 11.8% vs. 17.6%, P=1.000), incidence of ischemic stroke (1.3% vs. 0, P=1.000; 1.3% vs. 0, P=1.000), mean trans-aortic pressure gradient (11.4±6.4 mm Hg vs. 8.9±4.9 mm Hg, P=0.099; 10.5±7.6 mm Hg vs. 11.2±5.2 mm Hg, P=0.432), left ventricular ejection fraction (62.0%±9.0% vs. 57.0%±12.0%, P=0.189; 63.0%±7.0% vs. 60.0%±8.0%, P=0.170), and incidence of mitral valve dysfunction (0.6% vs. 5.9%, P=1.000; 0.6% vs. 5.9%, P=1.000). Conclusion It is feasible to treat perivalvular leakage with valve-in-valve technology in the procedure of TAVR, and the short and medium-term effects are satisfied.
ABSTRACT
Objective To evaluate the role of transthoracic echocardiography ( T T E ) and transesophageal echocardiography( T EE) in the process of transapical mitral valve repair using a novel edge‐to‐edge device( ValveClamp) and this device′s efficacy and safety in a preliminary clinical trial . Methods Six patients with moderate to severe or severe degenerative mitral regurgitation ( DM R) confirmed by T T E and T EE were enrolled . T T E was performed pre and post procedure as well as 30 days post procedures . Related cardiac structure and hemodynamic parameters ,including mitral regurgitation area ( MRA‐max ) , vena contracta width ( VCW ) ,mitral valve effective orifice area ( M VEOA ) ,left ventricular end diastolic diameter ( LVEDD ) , left ventricular end systolic diameter ( LVESD ) , left ventricular ejection fraction ( LVEF) ,max and mean mitral valve pressure gradient ( M VPG‐max and M VPG‐mean) were recorded and evaluated in a central core laboratory . Results All the procedures were successfully performed .M RA‐max , VCW and M VEOA decreased significantly post procedures ( all P < 0 .000 ) , and they remained no significant changes within 30 days post procedures ( all P > 0 .05 ) . M eanwhile ,M VPG‐max and M VPG‐mean slightly increased ( all P <0 .01 ) and left atrial anterior‐posterior dimension attenuated 30 days post procedures( P <0 .05) ,but all M VPG‐mean were lower than 5 mm Hg ( 1 mm Hg=0 .133 kPa) . T here were no significant changes in other hemodynamic parameters ( all P > 0 .05) . Conclusions T ransapical mitral valve repair using ValveClamp can be performed safely and a significant reduction in mitral regurgitation can be achieved in patients with DM R . T EE and T T E facilitate the patient selection for ValveClamp procedures as well as perioperative navigation and assessment .
ABSTRACT
Objective@#To investigate the effects of transcatheter aortic valve replacement (TAVR) in patients with severe aortic valve stenosis.@*Methods@#The clinical data of 130 patients with severe aortic valve stenosis, who underwent TAVR in our hospital with self-expanding valve between January 1,2010 and October 30, 2016, were analyzed retrospectively. The patients were divided into calcific aortic valve stenosis (CAS) group (112 cases) and non-calcific aortic valve stenosis (NCAS) group (18 cases) according to 3D volume-rendering reconstruction under multiple detector computed tomography before TAVR. The baseline clinical features, imageology results, procedural details, and clinical prognosis were compared between the 2 groups.@*Results@#(1) Compared with CAS group, the patients in NCAS group were younger, had higher proportion of rheumatic heart disease, and less proportion of bicuspid aortic valve morphology (P<0.01 or 0.05). Except for minimum value of sinotubular junction (P=0.017), there were no significant differences in multiple detector computed tomography measurements of aortic valve annulus and aortic root structure between the 2 groups (all P>0.05). (2) Compared with CAS group, the proportions of valve release under rapid pacing and oversized valve release were larger than pre-procedural evaluation, and the proportion of post-dilation was lower in NCAS group (P<0.01 or 0.05). (3) Post-procedural transthoracic echocardiography revealed that left ventricular ejection fraction was higher than baseline level in CAS group (P<0.001), while which was similar in NCAS group (P=0.552). Compared with before TAVR, mean pressure gradient and maximum transvalvular velocity were significantly reduced, aortic valve orifice area was significantly increased, and proportion of moderate to severe aortic regurgitation was significantly reduced after the procedure in both groups (all P<0.01). There were no significant differences in left ventricular ejection fraction, mean pressure gradient, maximum transvalvular velocity, aortic valve orifice area, and proportion of moderate to severe aortic regurgitation after TAVR between the 2 groups (all P>0.05). (4) There were no significant differences in successful rate of device placement and cardiovascular related death within 30 days after TAVR between the 2 groups (105/112 vs. 17/18, P=0.909; 3/112 vs. 1/18, P=0.453, respectively).@*Conclusion@#TAVR is safe and effective for patients with severe aortic valve stenosis.
ABSTRACT
Objective To evaluate the usefulness of real-time three-dimensional intraoperative epicardial echocardiography ( RT-3D IEE) in the process of transapical mitral valve repair and a new device's efficacy in an animal model . Methods Acute mitral regurgitation ( MR) was induced in 18 anesthetized domestic pigs as MR group by cutting chordae supporting the segment of the leaflet ( A2 , n = 9 ; P2 , n = 8 ;P3 , n = 1) ,while 15 pigs received no cutting chordae were chosed as normal mitral valve ( NMV ) group . The ValveClamp procedures were then transapically performed either on the prolapsing segment ( MR group) or A2/ P2 segment ( NMV group ) respectively solely under 3D epicardial echocardiographic guidance . Epicardial echocardiography was obtained before and after transcatheter interventions . Thirty days later all pigs were humanely killed to verify the location of implanted devices . Results In normal group , the preoperative max and mean mitral valve pressure gradient was higher than postoperative those ( P < 0 .0001) ,and no significant difference was found in other echocardiographic parameters . In MR group , the preoperative echocardiography showed that cutting the leaflet chordae caused severe ( n = 15 ) or moderate( n = 3) MR ,while postoperative immediate echo observed overt MR area reduction( P < 0 .0001) with 8 cases to slight ,5 cases to mild and 1 case eliminated .Furthermore ,the mean postoperative and max mitral valve pressure gradient significantly increased both in two groups ( P < 0 .0001 ) ,whereas no complications or other structural changes were observed ( P > 0 .05) .The autopsy report demonstrated that all ValveClamp devices were precisely placed to clamp either the prolapsing segments (MR group) of mitral valve or A2/P2 segments (NMV group) ,respectively .Conclusions Real-time three-dimensional epicardial echocardiography can independently monitor the new transcatheter mitral repair technique-ValveClamp , facilitating the overall procedure . Transapical implantation of ValveClamp device under epicardial echocardiographic guidance is effective in reducing acutely induced mitral regurgitation .
ABSTRACT
Objective@#To investigate the safety and efficacy of transcatheter aortic valve replacement(TAVR) through transcarotid approach for patients with severe aortic valve stenosis.@*Methods@#The clinical data of 9 symptomatic severe aortic valve stenosis patients who had high or prohibitive risk for surgery and not suitable for TAVR through femoral artery access,and thus received TAVR through transcarotid approach in our hospital from November 2015 to February 2017 were retrospectively analyzed.The patients were followed up to observe the safety and efficacy of the procedure.@*Results@#There were 4 male and 5 female patients in this cohort, and age was (75.7±8.7) years old. The Society of Thoracic Surgery (STS) scores were (7.9±1.6)%. All patients were treated by left carotid artery approach. One patient experienced valve dislodgement during the procedure and received surgery, and TAVR procedure was successful in the rest 8 patients. Two patients were implanted with permanent pacemaker because of third degree atrioventricular block during the procedure.One patient had cardiac arrest during the procedure and recovered after external chest compression.One patient developed severe carotid stenosis,and there was no clinical manifestation of nerve function deficit after the procedure. All patients were followed up at (30±3) days after the procedure, and there were no adverse events. The modified Rankin scale score was 0. Echocardiography examination showed that the tranvalvular mean gradient was reduced from (63.0±19.2)mmHg(1 mmHg=0.133 kPa) on baseline to (18.1±4.9)mmHg(P<0.001), 4 cases had mild paravalvular leakage, and there was no moderate or severe paravalvular leakage.The NYHA classes was significantly improved at 30 days when compared with before the procedure(2 cases class Ⅱ, 4 cases class Ⅲ,3 cases class Ⅳ before the procedure,and 5 cases classⅠ, 4 cases class Ⅱ after the procedure, P=0.006) , and left ventricular ejection fraction increased from (55.9±13.1)% to (60.4±10.0)% (P=0.030).@*Conclusion@#Our initial experience indicates that transcarotid TAVR is safe and effective for patients with severe aortic valve stenosis.
ABSTRACT
Objective To evaluate the impact of individualized occluder application on efficacy and complications of transcatheter closure treatment for multi-feneatrated atrial septal defects (mfASD).Methods Seventy six patients with mfASD who were hospitalized at Fudan University Zhongshan Hospital from July 2006 to July 2015 were retrospectively enrolled.Clinical and follow-up data were collected and analyzed.Results Among the 76 patients including 18 males and 58 females,transcatheter closure was successfully performed in 73 patients (96.1%).The morphological features of ASD included: 60 cases (78.9%) with two defects and 16 cases (21.1%) with cribriform defects, 3 cases (3.9%) combined with patent foramen ovale (PFO),13 cases (17.1%) with atrial septal aneurysm (ASA).Dual occluders were used for closure in 26 patients (35.6%),while single occluder was implanted in 47 patients (64.4%).In single-occluder group,measuring balloon was used to assist occlusion in 7 patients (14.9%).3 patients versus 11 patients required the small-waist-big-edge occluders in the dual-occluder group and the single-occluder group respectively (11.5% vs.23.4%, P=0.352).The complication rate in the dual-occluders group was higher than that in the single-occluder group (19.2% vs.4.3%, P=0.037),while the incidence of residual shunt showed no significant difference between these two groups (11.5% vs.10.6%, P=0.906).Conclusions The occluder for transcatheter closure of multiple atrial septal defects needs to be individually chosen according to the morphological characters.Transcatheter closure of mfASD using two devices is feasible,safe and effective for selected patients.
ABSTRACT
Objective To evaluate the left ventricle systolic function in patients with aortic stenosis (AS) underwent transcatheter aortic valve implantation(TAVI) by speckle tracking imaging and to observe the indicators in bicuspid aortic valves(BAV) and tricuspid aortic valves(TAV) groups.Methods Twenty nine patients with AS were enrolled,all of them underwent TAVI successfully.The regular echocardiography and 3D full-volume images were acquired on before and 3 days,1 month after TAVI.Longitudinal strain,circumferential strain,and three-dimensional left ventricle ejection fraction(3D-LVEF) were analyzed using Qlab software.Results Compared with the baseline,aortic valve blood flow velocity (AV),maximum aortic valve pressure gradient (AVPG-max),mean aortic valve pressure gradient (AVPG-mean),aortic valve area(AVA) after TAVI were improved significantly.Global longitudinal strain(GLS) had a improvement on 3 days after TAVI(all P <0.001),and further increased during 1 month after TAVI (all P <0.001).Global circumferential strain(GCS) were increased during 1 month after TAVI(all P < 0.001).The 3D-LVEF after 1 month were improved significantly(all P <0.001).The BAV patients and TAV patients had similar changes in all of indicators observed.Conclusions The left ventricle systolic function has early improvement after TAVI,and further recovery during follow-up.The BAV patients can obtain a benefit from TAVI equally to the TAV patients.
ABSTRACT
Objective To investigate the alternation of right ventricular volume and systolic function in patients with severe pulmonary regurgitation under percutaneous pulmonary valve implantation(PPVI) by real-time three-dimensional echocardiography(RT-3DE).Methods Ten patients with severe pulmonary regurgitation were enrolled.The 2D echocardiography images and real-time 3D full volume images on apical four-chamber view on a Philips IE33 system were acquired before PPVI and at 3 days,1 month,3months and 6 months after PPVI.Right ventricular end diastolic volume (EDV),end systolic volume(ESV),stroke volume (SV),ejection fraction(EF),fractional area change(FAC),tricuspid annular plane systolic excursion (TAPSE),right ventricular longitudinal strain-free wall(RVLSf) and right ventricular longitudinal strainseptum(RVLSs) were analysed using off-line TomTec software,the differences among the five groups were compared,and correlation analysis was made between the CMR and RT-3DE measurements.Results The level of pulmonary regurgitation had decreased or disappeared after PPVI.Compared with the preoperation,EDV,ESV at 3 days,1 month,3months and 6 months after operation had decreased significantly.EF,FAC,TAPSE,RVLS had increased significantly(all P <0.05).There were close correlation in EDV,ESV,EF between RT-3DE and CMR(pre-operation r =0.811,0.817,0.807,post-operation r =0.735,0.834,0.800,all P <0.055).Conclusions RV volume notably decreases while RV systolic function remarkably improves.The RT-3DE is a helpful technology in the evaluation of right ventricular volume and systolic function in patients after PPVI.