Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 74
Filter
1.
Article in English | WPRIM | ID: wpr-1000502

ABSTRACT

Pulmonary vein isolation is an well-established treatment strategy for atrial fibrillation (AF), and it is especially effective for patients with paroxysmal AF. However, the success rate is limited for patients with persistent AF, because non-pul‑ monary vein triggers which increase AF recurrence are frequently found in these patients. The major non-pulmonary vein triggers are from the left atrial posterior wall, left atrial appendage, ligament of Marshall, coronary sinus, superior vena cava, and crista terminalis, but other atrial sites can also generate AF triggers. All these sites have been known to contain atrial myocytes with potential arrhythmogenic electrical activity. The prevalence and clinical characteristics of these non-pulmonary vein triggers are well studied; however, the clinical outcome of catheter ablation for persistent AF is still unclear. Here, we reviewed the current ablation strategies for persistent AF and the clinical implications of major non-pulmonary vein triggers.

2.
Article in English | WPRIM | ID: wpr-937688

ABSTRACT

Background@#The efficacy and safety of high-power, short-duration (HPSD) radiofrequency catheter ablation for atrial fibrillation (AF) have been demonstrated in several studies. We aimed to evaluate and compare the effects of the conventional method and the HPSD method for AF ablation on the sinus and AV node function in patients with paroxysmal AF. @*Methods@#The medical records of patients with paroxysmal AF who underwent pulmonary vein isolation (PVI) were retrieved from a prospectively collected AF ablation registry at a large-sized tertiary center. The HPSD group (n = 41) was distinguished from the conventional ablation group (n = 198) in terms of the power (50 W vs. 20–40 W) and dura‑ tion (6–10 s vs. 20–30 s) of radiofrequency energy delivery during PVI. Peri-procedural changes in cardiac autonomy were assessed in terms of the changes in sinus cycle length (SCL), block cycle length (BCL), and effective refractory period (ERP) of the atrioventricular node (AVN). @*Results@#The SCL, BCL, and ERP of the AVN at baseline and post-ablation were not significantly different between the conventional ablation group and the HPSD group. Shortening of the SCL, BCL, and ERP of the AVN was observed immediately after AF ablation in both groups. One-year recurrence of AF/atrial flutter (35.1% vs. 20.3%; P = 0.011) and atrial flutter (13.8% vs. 4.7%; P = 0.015) were higher in the HPSD group than in the conventional ablation group. @*Conclusion@#Both the HPSD and the conventional ablation method resulted in post-ablation vagal modification as evidenced by the shortening of SCL, BCL, and ERP of the AVN. One-year recurrence of atrial flutter and AF/atrial flutter was higher in patients who underwent the HPSD method.

3.
Korean Circulation Journal ; : 513-526, 2022.
Article in English | WPRIM | ID: wpr-938456

ABSTRACT

Background and Objectives@#Atrial tachycardias (ATs) from noncoronary aortic cusp (NCC) uncovered after radiofrequency ablation for atrial fibrillation (AF) are rarely reported. This study was conducted to investigate the prevalence and clinical characteristics of NCC ATs detected during AF ablation and compare their characteristics with de novo NCC ATs without AF. @*Methods@#Consecutive patients who underwent radiofrequency catheter ablation for AF were reviewed from the multicenter AF ablation registry of 11 tertiary hospitals. The clinical and electrophysiological characteristics of NCC AT newly detected during AF ablation were compared with its comparators (de novo NCC AT ablation cases without AF). @*Results@#Among 10,178 AF cases, including 1,301 redo ablation cases, 8 (0.08%) NCC AT cases were discovered after pulmonary vein isolation (PVI; 0.07% in first ablation and 0.15% in redo ablation cases). All ATs were reproducibly inducible spontaneously or with programmed atrial stimulation without isoproterenol infusion. The P-wave morphological features of tachycardia were variable depending on the case, and most cases exhibited 1:1 atrioventricular conduction. AF recurrence rate after PVI and NCC AT successful ablation was 12.5% (1 of 8). Tachycardia cycle length was shorter than that of 17 de novo ATs from NCC (303 versus 378, p=0.012). No AV block occurred during and after successful AT ablation. @*Conclusions@#Uncommon NCC ATs (0.08% in AF ablation cases) uncovered after PVI, showing different characteristics compared to de-novo NCC ATs, should be suspected irrespective of P-wave morphologies when AT shows broad propagation from the anterior interatrial septum.

4.
Article in English | WPRIM | ID: wpr-927030

ABSTRACT

Background/Aims@#The safety of direct oral anticoagulants (DOACs) compared with warfarin in patients with both nonvalvular atrial fibrillation (AF) and clinically confirmed liver cirrhosis (LC) has not been well studied. We compared the risk of a major bleeding event between DOAC and warfarin treatments in this patient population. @*Methods@#A total of 238 cirrhotic patients with AF were retrospectively analyzed. The major bleeding event risk was compared between DOAC- and warfarin-treated groups. The median follow-up duration was 5.6 years. @*Results@#Among the 238 study patients with LC and AF, 128 (53.8%) received DOACs and 110 (46.2%) received warfarin. The mean patient age was 68.8 years, and 78.2% were men. A major bleeding event occurred in 10 and 20 patients in the DOAC and warfarin groups, respectively, most commonly caused by gastrointestinal bleeding (70.0%). The cumulative risk of major bleeding did not differ between the groups by log-rank test (p = 0.12). This finding did not change when using 60 propensity score-matched pairs. A multivariable Cox regression model indicated that the concomitant use of antiplatelet agents (adjusted hazard ratio [aHR], 2.06; 95% confidence interval [CI], 1.00 to 4.30; p = 0.048) and presence of esophageal or gastric varices confirmed by endoscopic examination (aHR, 2.31; 95% CI, 1.03 to 5.17; p = 0.04) were associated with major bleeding in the entire cohort. @*Conclusions@#A major bleeding event risk is not increased by DOAC compared with warfarin treatment. Antiplatelet agent use and varices are independently associated with a higher risk of major bleeding during anticoagulation.

5.
Korean Circulation Journal ; : 143-153, 2021.
Article in English | WPRIM | ID: wpr-901604

ABSTRACT

Background and Objectives@#Data regarding the safety of atrial fibrillation (AF) ablation using high-power (50 W) radiofrequency (RF) energy in Asian populations are limited. This study was conducted to evaluate the incidence and pattern of esophageal injury after highpower AF ablation in an Asian cohort. @*Methods@#We searched the prospective AF ablation registry to identify patients who underwent AF ablation with 50 W RF energy using the smart touch surround flow catheter (Biosense Webster, Diamond Bar, CA, USA). Visitag™ (Biosense Webster) was used for lesion annotation with predefined settings of catheter stability (3 mm for 5 seconds) and minimum contact force (50% of time >5 g). All patients underwent upper gastrointestinal endoscopy at 1 or 3 days after the ablation. @*Results@#A total of 159 patients (mean age: 63±9 years, male: 69%, paroxysmal AF: 45.3%, persistent AF: 27.7%, long-standing persistent AF: 27.0%) were analyzed. Initially, 26 patients underwent pulmonary vein isolation with 50 W for 5 seconds at each point. The remaining 133 patients underwent prolonged RF duration (anterior 10 seconds and posterior 6 seconds). The incidence rates of esophageal erythema/erosion and superficial ulceration were 1.3% for each type of the lesion. Food stasis, a suggestive finding of gastroparesis, was observed in 25 (15.7%) patients. There were no cases of cardiac tamponade, stroke, or death. @*Conclusions@#In Asian patients, AF ablations using 50 W resulted in very low rates of mild esophageal complications.

6.
Korean Journal of Radiology ; : 1609-1618, 2021.
Article in English | WPRIM | ID: wpr-902487

ABSTRACT

Objective@#Arrhythmogenic mitral valve prolapse (MVP) is an important cause of sudden cardiac death characterized by fibrosis of the papillary muscles or left ventricle (LV) wall, and an association between late gadolinium enhancement (LGE) of the LV papillary muscles and ventricular arrhythmia in MVP has been reported. However, LGE of the papillary muscles may be observed in other causes of mitral regurgitation, and it is not limited to patients with MVP. This study was to evaluate the association of LGE of the LV papillary muscles or ventricular wall on cardiac magnetic resonance imaging (CMR) and ventricular arrhythmia in patients with mitral regurgitation. @*Materials and Methods@#This study included 88 patients (mean age ± standard deviation, 58.3 ± 12.0 years; male, 42%) with mitral regurgitation who underwent CMR. They were allocated to the MVP (n = 43) and non-MVP (n = 45) groups, and their LGE images on CMR, clinical characteristics, echocardiographic findings, and presence of arrhythmia were compared. @*Results@#LV myocardial wall enhancement was more frequent in the MVP group than in the non-MVP group (28% vs. 11%, p = 0.046). Papillary muscle enhancement was observed in 7 (7.9%) patients. Of the 43 patients with MVP, 15 (34.8%) showed LGE in the papillary muscles or LV myocardium, including 12 (27.9%) with LV myocardial wall enhancement and 4 (9.3%) with papillary muscle enhancement. One patient with bilateral diffuse papillary muscle enhancement experienced sudden cardiac arrest due to ventricular fibrillation. Univariable logistic regression analysis showed that high systolic blood pressure (BP; odds ratio [OR], 1.05; 95% confidence interval [CI], 1.01–1.09; p = 0.027) and ventricular arrhythmia (OR, 6.84; 95% CI, 1.29–36.19; p = 0.024) were significantly associated with LGE of the papillary muscles. @*Conclusion@#LGE of the papillary muscles was present not only in patients with MVP, but also in patients with other etiologies of mitral regurgitation, and it was associated with high systolic BP and ventricular arrhythmia. Papillary muscle enhancement on CMR should not be overlooked.

7.
Article in English | WPRIM | ID: wpr-903665

ABSTRACT

Background/Aims@#Atrial fibrillation (AF)-related stroke accounts for 20% of ischemic strokes. Rivaroxaban use in AF patients for preventing stroke and systemic embolism was approved in 2013 in Korea. This study was to investigate the safety and effectiveness of rivaroxaban use in Korean patients with non-valvular AF in a real-world setting. @*Methods@#This was an analysis of the Korean patients in Xarelto for Prevention of Stroke in Patients with Atrial Fibrillation in Asia-Pacific (XANAP), which was a prospective, observational cohort study including patients with non-valvular AF starting rivaroxaban treatment to prevent stroke or non-central nervous system systemic embolism (non-CNS SE), conducted in 10 Asian countries. @*Results@#A total of 844 patients were enrolled in the Korean portion of the XANAP study. In XANAP Korea, the mean age was 70.1 years and 62.6% were males. The mean CHADS2 score was 2.5 and the mean CHA2DS2-VASc score was 3.8. 47% of the patients had experienced prior stroke or non-CNS SE or transient ischemic attack. 73.6% of the patients had CHADS2 score ≥ 2. Incidence proportions of 0.8% of the patients (1.1 per 100 patient-years) developed adjudicated treatment-emergent major bleeding. Death was observed in 1.2% of the patients. The incidence of non-major bleeding as well as thromboembolic event were 8.4% (11.6 per 100 patient-years) and 1.5% (2.0 per 100 patient-years), respectively. @*Conclusions@#This study reaffirmed the consistent safety profile of rivaroxaban. We found consistent results with overall XANAP population for rivaroxaban in terms of safety in non-valvular AF patients for the prevention of stroke and non-CNS SE.

8.
Korean Circulation Journal ; : 143-153, 2021.
Article in English | WPRIM | ID: wpr-893900

ABSTRACT

Background and Objectives@#Data regarding the safety of atrial fibrillation (AF) ablation using high-power (50 W) radiofrequency (RF) energy in Asian populations are limited. This study was conducted to evaluate the incidence and pattern of esophageal injury after highpower AF ablation in an Asian cohort. @*Methods@#We searched the prospective AF ablation registry to identify patients who underwent AF ablation with 50 W RF energy using the smart touch surround flow catheter (Biosense Webster, Diamond Bar, CA, USA). Visitag™ (Biosense Webster) was used for lesion annotation with predefined settings of catheter stability (3 mm for 5 seconds) and minimum contact force (50% of time >5 g). All patients underwent upper gastrointestinal endoscopy at 1 or 3 days after the ablation. @*Results@#A total of 159 patients (mean age: 63±9 years, male: 69%, paroxysmal AF: 45.3%, persistent AF: 27.7%, long-standing persistent AF: 27.0%) were analyzed. Initially, 26 patients underwent pulmonary vein isolation with 50 W for 5 seconds at each point. The remaining 133 patients underwent prolonged RF duration (anterior 10 seconds and posterior 6 seconds). The incidence rates of esophageal erythema/erosion and superficial ulceration were 1.3% for each type of the lesion. Food stasis, a suggestive finding of gastroparesis, was observed in 25 (15.7%) patients. There were no cases of cardiac tamponade, stroke, or death. @*Conclusions@#In Asian patients, AF ablations using 50 W resulted in very low rates of mild esophageal complications.

9.
Korean Journal of Radiology ; : 1609-1618, 2021.
Article in English | WPRIM | ID: wpr-894783

ABSTRACT

Objective@#Arrhythmogenic mitral valve prolapse (MVP) is an important cause of sudden cardiac death characterized by fibrosis of the papillary muscles or left ventricle (LV) wall, and an association between late gadolinium enhancement (LGE) of the LV papillary muscles and ventricular arrhythmia in MVP has been reported. However, LGE of the papillary muscles may be observed in other causes of mitral regurgitation, and it is not limited to patients with MVP. This study was to evaluate the association of LGE of the LV papillary muscles or ventricular wall on cardiac magnetic resonance imaging (CMR) and ventricular arrhythmia in patients with mitral regurgitation. @*Materials and Methods@#This study included 88 patients (mean age ± standard deviation, 58.3 ± 12.0 years; male, 42%) with mitral regurgitation who underwent CMR. They were allocated to the MVP (n = 43) and non-MVP (n = 45) groups, and their LGE images on CMR, clinical characteristics, echocardiographic findings, and presence of arrhythmia were compared. @*Results@#LV myocardial wall enhancement was more frequent in the MVP group than in the non-MVP group (28% vs. 11%, p = 0.046). Papillary muscle enhancement was observed in 7 (7.9%) patients. Of the 43 patients with MVP, 15 (34.8%) showed LGE in the papillary muscles or LV myocardium, including 12 (27.9%) with LV myocardial wall enhancement and 4 (9.3%) with papillary muscle enhancement. One patient with bilateral diffuse papillary muscle enhancement experienced sudden cardiac arrest due to ventricular fibrillation. Univariable logistic regression analysis showed that high systolic blood pressure (BP; odds ratio [OR], 1.05; 95% confidence interval [CI], 1.01–1.09; p = 0.027) and ventricular arrhythmia (OR, 6.84; 95% CI, 1.29–36.19; p = 0.024) were significantly associated with LGE of the papillary muscles. @*Conclusion@#LGE of the papillary muscles was present not only in patients with MVP, but also in patients with other etiologies of mitral regurgitation, and it was associated with high systolic BP and ventricular arrhythmia. Papillary muscle enhancement on CMR should not be overlooked.

10.
Article in English | WPRIM | ID: wpr-895961

ABSTRACT

Background/Aims@#Atrial fibrillation (AF)-related stroke accounts for 20% of ischemic strokes. Rivaroxaban use in AF patients for preventing stroke and systemic embolism was approved in 2013 in Korea. This study was to investigate the safety and effectiveness of rivaroxaban use in Korean patients with non-valvular AF in a real-world setting. @*Methods@#This was an analysis of the Korean patients in Xarelto for Prevention of Stroke in Patients with Atrial Fibrillation in Asia-Pacific (XANAP), which was a prospective, observational cohort study including patients with non-valvular AF starting rivaroxaban treatment to prevent stroke or non-central nervous system systemic embolism (non-CNS SE), conducted in 10 Asian countries. @*Results@#A total of 844 patients were enrolled in the Korean portion of the XANAP study. In XANAP Korea, the mean age was 70.1 years and 62.6% were males. The mean CHADS2 score was 2.5 and the mean CHA2DS2-VASc score was 3.8. 47% of the patients had experienced prior stroke or non-CNS SE or transient ischemic attack. 73.6% of the patients had CHADS2 score ≥ 2. Incidence proportions of 0.8% of the patients (1.1 per 100 patient-years) developed adjudicated treatment-emergent major bleeding. Death was observed in 1.2% of the patients. The incidence of non-major bleeding as well as thromboembolic event were 8.4% (11.6 per 100 patient-years) and 1.5% (2.0 per 100 patient-years), respectively. @*Conclusions@#This study reaffirmed the consistent safety profile of rivaroxaban. We found consistent results with overall XANAP population for rivaroxaban in terms of safety in non-valvular AF patients for the prevention of stroke and non-CNS SE.

11.
Article in 0 | WPRIM | ID: wpr-835470

ABSTRACT

Background@#The incidence of inappropriate shocks remains high at 30% in patients with implantable cardioverter-defibrillators (ICDs). This retrospective study sought to examine the efficacy of strategic programming (ICD programming with a long detection interval and high-rate cutoff) in reducing electrical storm, inappropriate shocks, and unexpected hospital visits in patients with ICDs with/without cardiac resynchronization therapy with defibrillator (CRT-Ds). @*Methods@#This was a single tertiary center retrospective study, evaluating the clinical outcomes, especially regarding inappropriate therapies in patients with ICDs or CRT-Ds. Enrolled patients underwent ICD or CRT-D implantations from January 2008 to May 2016. Clinical information was attained by a thorough chart review. @*Results@#We analyzed 155 defibrillator patients from January 2008 to May 2016 (124 patients had ICDs and 31 had CRT-Ds). Since we adopted this strategic programming as a default programming from 2015 implanted ICDs and CRT-Ds, we divided the patients into two groups: devices implanted before 2015 (group A, n = 94) versus implanted after 2015 (group B, n = 61). During a median of 1289 days of follow-up, electrical storms occurred in three patients (eight events) in group B versus 11 (28 events) in group A (P = 0.18); appropriate therapies were delivered in 27 patients (56 events) in group A versus 7 (15 events) in group B (P = 0.72); inappropriate therapies were delivered in 15 patients (21 events) in group A versus 1 with 1 episode in group B (P = 0.03); and 5 unexpected hospitalizations occurred in four patients in group B versus 36 in 24 patients in group A (P = 0.02). @*Conclusion@#The clinical application of strategic programming reduced inappropriate shocks and unexpected hospitalizations in ICD and CRT-D patients.

12.
Article in 0 | WPRIM | ID: wpr-835475

ABSTRACT

Background@#An automated tagging module (VISITAG™; Biosense Webster, Irvine, CA) allows objective demonstration of energy delivery. However, the effect of VISITAG™ on clinical outcomes remains unclear. This study evaluated (1) clinical outcome after AF ablation using VISITAG™ and (2) the prevalence of gaps in the ablation line. @*Methods@#This retrospective analysis included 157 consecutive patients (mean age, 56.7 years; 73.2% men) with paroxysmal atrial fibrillation who underwent successful PVI between 2013 and 2016. Outcomes after the index procedure were compared between those using the VISITAG™ module (VISITAG group, n = 62) and those not using it (control group, n = 95). The primary outcome was recurrence of AF or atrial tachycardia after a blanking period of 3 months. @*Results@#The VISITAG group showed significantly shorter overall procedure time (172.2 ± 37.6 min vs. 286.9 ± 66.7 min, P  15 s,  60% force over time, > 6 g contact force) showed higher recurrence-free survival rate compared with those with gaps (borderline statistical significance, 91.7% vs. 66.0%, P = 0.094). @*Conclusion@#Use of the VISITAG™ module significantly reduced procedure, ablation, and fluoroscopic times with a similar AF/AT recurrence rate compared with the conventional ablation. Clinical implications of minimizing gaps along the ablation line should be evaluated further in the future prospective studies.

13.
Korean Circulation Journal ; : 148-159, 2020.
Article in English | WPRIM | ID: wpr-832983

ABSTRACT

BACKGROUND AND OBJECTIVES@#Atrial fibrillation (AF) is associated with a higher long-term risk of major cardiovascular events. However, its clinical implications with respect to peri-operative cardiovascular outcomes in patients undergoing non-cardiac surgery is unclear. We tried to examine the association between pre-operative AF and peri-operative cardiovascular outcomes.@*METHODS@#We retrospectively analyzed data from 26,501 consecutive patients who underwent comprehensive preoperative cardiac evaluations for risk stratification prior to receiving non-cardiac surgery at our center. Preoperative AF was diagnosed in 1,098 patients (4.1%), and their cardiovascular outcomes were compared with those of patients without AF. The primary outcome was the rate of major adverse cardiac and cerebrovascular events (MACCE) during immediate post-surgery period (<30 days).@*RESULTS@#Patients with AF were older and had higher proportion of male sex, higher rate of extra-cardiac comorbidities, higher CHA₂DS₂-VASc score, and higher revised cardiac risk index (RCRI) compared with those without AF. The rate of MACCE was significantly higher in AF patients compared to non-AF patients (4.6% vs. 1.2%, p<0.001). Preoperative AF was associated with higher risk of MACCE, even after multivariable adjustment (odds ratio, 2.97; 95% confidence interval, 2.13–4.07, p<0.001). The relative contribution of AF to MACCE was larger in patients with lower RCRI (p for interaction=0.010). The discriminating performance of RCRI was significantly enhanced by addition of AF.@*CONCLUSIONS@#In patients undergoing non-cardiac surgery, preoperative AF was associated with a higher risk of peri-operative cardiovascular outcomes.

14.
Korean Circulation Journal ; : 998-1009, 2020.
Article | WPRIM | ID: wpr-833063

ABSTRACT

Background and Objectives@#Pacemaker (PM) implantation is a well-accepted treatment option for patients with paroxysmal atrial fibrillation (AF) and related tachycardiabradycardia syndrome (TBS). Data on the long-term clinical outcomes after radiofrequency catheter ablation (RFCA) or PM implantation are sparse. @*Methods@#The medical records of 217 patients with TBS were retrospectively assessed.Outcomes in patients who underwent RFCA (n=108, 49.8%) were compared to those with PM implantation (n=109, 50.2%). The clinical outcomes were sinus rhythm maintenance, conversion to persistent AF, additional procedure or crossover, and the composite of cardiovascular hospitalization and death. @*Results@#During the follow-up period (mean 3.5±2.0 years), the RFCA group, compared to the PM group, showed better sinus rhythm maintenance (adjusted hazard ratio [aHR], 0.27;95% confidence interval [CI], 0.15–0.46; p=0.002) and less progression to persistent AF (aHR, 0.20; 95% CI, 0.06–0.63; p=0.006). Additional procedure or crossover did not differ significantly between the groups (aHR, 2.07; 95% CI, 0.71–6.06; p=0.185 and aHR, 0.69; 95% CI, 10.8–2.67; p=0.590, respectively). Most RFCA patients (92.6%) did not require pacemaker implantation during long term follow-up period (>3.5 years). The composite endpoint of cardiovascular rehospitalization and death was not significantly different between the groups (aHR, 0.92; 95% CI, 0.50–1.66; p=0.769).Background and Objectives: Pacemaker (PM) implantation is a well-accepted treatment option for patients with paroxysmal atrial fibrillation (AF) and related tachycardiabradycardia syndrome (TBS). Data on the long-term clinical outcomes after radiofrequency catheter ablation (RFCA) or PM implantation are sparse. @*Methods@#The medical records of 217 patients with TBS were retrospectively assessed.Outcomes in patients who underwent RFCA (n=108, 49.8%) were compared to those with PM implantation (n=109, 50.2%). The clinical outcomes were sinus rhythm maintenance, conversion to persistent AF, additional procedure or crossover, and the composite of cardiovascular hospitalization and death. @*Results@#During the follow-up period (mean 3.5±2.0 years), the RFCA group, compared to the PM group, showed better sinus rhythm maintenance (adjusted hazard ratio [aHR], 0.27;95% confidence interval [CI], 0.15–0.46; p=0.002) and less progression to persistent AF (aHR, 0.20; 95% CI, 0.06–0.63; p=0.006). Additional procedure or crossover did not differ significantly between the groups (aHR, 2.07; 95% CI, 0.71–6.06; p=0.185 and aHR, 0.69; 95% CI, 10.8–2.67; p=0.590, respectively). Most RFCA patients (92.6%) did not require pacemaker implantation during long term follow-up period (>3.5 years). The composite endpoint of cardiovascular rehospitalization and death was not significantly different between the groups (aHR, 0.92; 95% CI, 0.50–1.66; p=0.769). @*Conclusions@#RFCA is an effective alternative to PM implantation in patients with TBS.In these patients, successful RF ablation of AF is related to a higher rate of sinus rhythm maintenance compared to PM implantation, and the composite outcome of cardiovascular rehospitalization and death is similar.

15.
Korean Circulation Journal ; : 148-159, 2020.
Article in English | WPRIM | ID: wpr-786223

ABSTRACT

BACKGROUND AND OBJECTIVES: Atrial fibrillation (AF) is associated with a higher long-term risk of major cardiovascular events. However, its clinical implications with respect to peri-operative cardiovascular outcomes in patients undergoing non-cardiac surgery is unclear. We tried to examine the association between pre-operative AF and peri-operative cardiovascular outcomes.METHODS: We retrospectively analyzed data from 26,501 consecutive patients who underwent comprehensive preoperative cardiac evaluations for risk stratification prior to receiving non-cardiac surgery at our center. Preoperative AF was diagnosed in 1,098 patients (4.1%), and their cardiovascular outcomes were compared with those of patients without AF. The primary outcome was the rate of major adverse cardiac and cerebrovascular events (MACCE) during immediate post-surgery period (<30 days).RESULTS: Patients with AF were older and had higher proportion of male sex, higher rate of extra-cardiac comorbidities, higher CHA₂DS₂-VASc score, and higher revised cardiac risk index (RCRI) compared with those without AF. The rate of MACCE was significantly higher in AF patients compared to non-AF patients (4.6% vs. 1.2%, p<0.001). Preoperative AF was associated with higher risk of MACCE, even after multivariable adjustment (odds ratio, 2.97; 95% confidence interval, 2.13–4.07, p<0.001). The relative contribution of AF to MACCE was larger in patients with lower RCRI (p for interaction=0.010). The discriminating performance of RCRI was significantly enhanced by addition of AF.CONCLUSIONS: In patients undergoing non-cardiac surgery, preoperative AF was associated with a higher risk of peri-operative cardiovascular outcomes.


Subject(s)
Humans , Male , Atrial Fibrillation , Comorbidity , Retrospective Studies , Risk Assessment , Stroke
16.
Korean Circulation Journal ; : 437-445, 2019.
Article in English | WPRIM | ID: wpr-917320

ABSTRACT

BACKGROUND AND OBJECTIVES@#Wrist-worn wearable devices provide heart rate (HR) monitoring function via photoplethysmography technology. Recently, these devices have been used by patients to measure the HR when palpitation occurs, but few validation studies of these instruments have been conducted. We assessed the accuracy of these devices for measuring a HR.@*METHODS@#This study enrolled 51 consecutive patients with a history of paroxysmal supraventricular tachyarrhythmia (SVT) or paroxysmal palpitations who were scheduled to undergo an electrophysiological study (EPS). Three devices were assessed: Apple Watch Series 2 (Apple), Samsung Galaxy Gear S3 (Galaxy), and Fitbit Charge 2 (Fitbit). Patients were randomly assigned to wear 2 different devices. The HR at baseline and induced SVT were measured during the EPS. After successful ablation of SVT, HR measurements was also done during atrial and ventricular pacing study.@*RESULTS@#The mean patient age was 44.4±16.6 years and 27 patients were male (53%). The accuracy (within ±5 beats per minute [bpm] of an electrocardiogram [ECG] measurement) of the baseline HR measurements was 100%, 100%, and 94%, for Apple, Galaxy, and Fitbit, respectively. The HR during induced SVT ranged from 108 bpm to 228 bpm and the accuracy (within ±10 bpm of an ECG) was 100%, 90%, and 87% for the Apple, Galaxy, and Fitbit, respectively. During pacing study, accuracy of these devices was also acceptable but tended to decrease as the HR increased, and showed differences between the devices.@*CONCLUSIONS@#Wrist-worn wearable devices accurately measure baseline and induced SVT HR.TRIAL REGISTRATION: Clinical Research Information Service Identifier: KCT0002282

17.
Yonsei Medical Journal ; : 360-367, 2019.
Article in English | WPRIM | ID: wpr-742547

ABSTRACT

PURPOSE: Catheter ablation for atrial fibrillation (AF) requires heavy anticoagulation and uncomfortable post-procedural hemostasis. We compared patient satisfaction with and the safety of unilateral groin (UG) puncture-single trans-septal (ST) ablation with conventional bilateral groin (BG) puncture-double trans-septal (DT) ablation in paroxysmal AF patients. MATERIALS AND METHODS: We enrolled 222 patients with paroxysmal AF (59.4±10.7 years old) who were randomized in a 2:1 manner into UG-ST ablation (n=148) and BG-DT ablation (n=74) groups. If circumferential pulmonary vein isolation could not be achieved after three attempts of touch-up ablation in the UG-ST group, the patient was crossed over to BG-DT by performing a left groin puncture. RESULTS: Ten patients in the UG-ST group (6.8%) required crossover to the BG-DT approach. There were no significant differences in procedure time (p=0.144) and major complications rate (p>0.999) between the UG-ST and BG-DT groups. Access site pain (p=0.014), back pain (p=0.023), and total pain (p=0.015) scores were significantly lower for the UG-ST than BG-DT group as assessed by the Visual Analog Scale. Over 20.2±8.7 months of follow up, there was no difference in AF recurrence free-survival rates between the two groups (Log rank, p=0.984). CONCLUSION: UG-ST AF ablation is feasible and safe, and was found to significantly reduce post-procedural hemostasis-related discomfort, compared to the conventional DT approach, in patients with paroxysmal AF.


Subject(s)
Humans , Atrial Fibrillation , Back Pain , Catheter Ablation , Follow-Up Studies , Groin , Hemostasis , Patient Satisfaction , Prospective Studies , Pulmonary Veins , Punctures , Recurrence , Visual Analog Scale
18.
Korean Circulation Journal ; : 437-445, 2019.
Article in English | WPRIM | ID: wpr-738798

ABSTRACT

BACKGROUND AND OBJECTIVES: Wrist-worn wearable devices provide heart rate (HR) monitoring function via photoplethysmography technology. Recently, these devices have been used by patients to measure the HR when palpitation occurs, but few validation studies of these instruments have been conducted. We assessed the accuracy of these devices for measuring a HR. METHODS: This study enrolled 51 consecutive patients with a history of paroxysmal supraventricular tachyarrhythmia (SVT) or paroxysmal palpitations who were scheduled to undergo an electrophysiological study (EPS). Three devices were assessed: Apple Watch Series 2 (Apple), Samsung Galaxy Gear S3 (Galaxy), and Fitbit Charge 2 (Fitbit). Patients were randomly assigned to wear 2 different devices. The HR at baseline and induced SVT were measured during the EPS. After successful ablation of SVT, HR measurements was also done during atrial and ventricular pacing study. RESULTS: The mean patient age was 44.4±16.6 years and 27 patients were male (53%). The accuracy (within ±5 beats per minute [bpm] of an electrocardiogram [ECG] measurement) of the baseline HR measurements was 100%, 100%, and 94%, for Apple, Galaxy, and Fitbit, respectively. The HR during induced SVT ranged from 108 bpm to 228 bpm and the accuracy (within ±10 bpm of an ECG) was 100%, 90%, and 87% for the Apple, Galaxy, and Fitbit, respectively. During pacing study, accuracy of these devices was also acceptable but tended to decrease as the HR increased, and showed differences between the devices. CONCLUSIONS: Wrist-worn wearable devices accurately measure baseline and induced SVT HR. TRIAL REGISTRATION: Clinical Research Information Service Identifier: KCT0002282


Subject(s)
Humans , Male , Electrocardiography , Galaxies , Heart Rate , Heart , Information Services , Photoplethysmography , Tachycardia , Tachycardia, Supraventricular
19.
Article in English | WPRIM | ID: wpr-739961

ABSTRACT

A 57-year-old woman scheduled for cochlear implant removal exhibited preoperative electrocardiographic findings of early repolarization (ER). Four episodes of transient ST segment elevations during surgery raised suspicion for vasospastic angina (VA). In the post-anesthetic care unit, the patient complained of chest discomfort and received sublingual nitroglycerin with uncertain effect. The patient refused to proceed with postoperative invasive coronary angiography, resulting in inconclusive diagnosis. Intraoperative circumstances limit the diagnosis of VA, which emphasizes the need for further testing to confirm the diagnosis. When VA is suspected in patients with underlying ER, it is reasonable to consider invasive examination to establish the diagnosis and prevent recurrence of VA. If ST changes are observed during surgery in patients with preoperative ER, careful monitoring is recommended. Due to general anesthesia, the absence of patient symptoms limits the definitive diagnosis of those with suspected VA. Therefore, additional postoperative surveillance is recommended.


Subject(s)
Female , Humans , Middle Aged , Anesthesia, General , Cochlear Implants , Coronary Angiography , Diagnosis , Electrocardiography , Head , Neck , Nitroglycerin , Recurrence , Thorax
20.
Article in Korean | WPRIM | ID: wpr-740052

ABSTRACT

Treatment of ventricular arrhythmias (VA) usually involves managing the underlying cardiac conditions that cause the arrhythmia. However, managing the underlying disease is often challenging, and catheter ablation, or treatment targeting the VA itself might be required in a few patients. In this article, we explored evidence and recommendations regarding the treatment of VA in patients with structural heart disease focusing on the utilization of catheter ablation in these patients. The administration of optimal medical therapy, insertion of an implantable cardioverter-defibrillator, or resynchronization therapy improves survival in patients with left ventricular dysfunction. The role of catheter ablation in preventing sudden cardiac death remains uncertain in this population. In patients with coronary artery disease, reversing myocardial ischemia via revascularization is important in managing VA. Catheter ablation is recommended in patients with recurrent ventricular tachycardia in a setting of ischemic heart disease. In patients with non-ischemic cardiomyopathies such as dilated cardiomyopathy or hypertrophic cardiomyopathy, catheter ablation may be considered for those presenting with drug-refractory ventricular tachycardia.


Subject(s)
Humans , Arrhythmias, Cardiac , Cardiomyopathies , Cardiomyopathy, Dilated , Cardiomyopathy, Hypertrophic , Catheter Ablation , Catheters , Coronary Artery Disease , Death, Sudden, Cardiac , Defibrillators, Implantable , Heart Diseases , Myocardial Ischemia , Tachycardia, Ventricular , Ventricular Dysfunction, Left
SELECTION OF CITATIONS
SEARCH DETAIL