ABSTRACT
Objective To compare the accuracy of bedside lung ultrasound in emergency(BLUE)and combined cardiac-lung and additional ultrasound(CLAUS)for diagnosing the causes of acute dyspnea.Methods Totally 1 016 patients with acute dyspnea were retrospectively enrolled and divided into cardiogenic pulmonary edema group(n=268),pneumonia group(n=574),pneumothorax group(n=33),pulmonary embolism group(n=67)and CAD(chronic obstructive pulmonary disease/asthma/diaphragmatic dysfunction)group(n=74)according to the causes of acute dyspnea.The findings of CLAUS protocol were compared among groups,and the accuracy of BLUE and CLAUS protocol for diagnosing the causes of acute dyspnea were also compared.Results CLAUS showed that B-B and B-C were the most common modes in cardiogenic pulmonary edema group,while A-B/A-C/B-A/B-B/B-C/C-C modes were common in pneumonia group,and A-A mode was the most common in pneumothorax group,pulmonary embolism group and CAD group.Significant differences of the manifestations of pulmonary ultrasound,pleural feature of anterior chest wall,left/right cardiac insufficiency and abnormal inferior vena cava diameter were found among groups(all P<0.05).The accuracy of BLUE and CLAUS protocol for diagnosing the causes of acute dyspnea was 86.91%(883/1 016)and 94.49%(960/1 016),respectively,the latter was higher than the former(χ2=34.587,P<0.05).Conclusion CLAUS protocol could be used to effectively diagnose the causes of acute dyspnea,with higher accuracy than BLUE protocol.
ABSTRACT
Objective:To analyze the cardio-pulmonary ultrasound features of cardiogenic pulmonary edema (CPE) and pneumonia in adults with acute dyspnea, and to construct a differential diagnosis model.Methods:Seven hundred and forty-three patients with sudden acute dyspnea admitted to Hebei General Hospital from November 2018 to May 2022 were retropectively included. Ultrasonographer A performed lung ultrasound with 12 zone method, and interpreted and recorded the ultrasonic signs (including A-lines area, B-lines area, consolidation area and pleural effusion area) together with ultrasonographer B. According to the ultrasonic characteristics of the whole lung, it was divided into A-profile and B-profile. According to the continuity and symmetry of the distribution of B-lines in bilateral lung fields, it could be divided into bilateral lung continuous and discontinuous B-profile, bilateral lung symmetric and asymmetric B-profile. Left ventricular ejection fraction (LVEF), left ventricular filling pressure (E/e′), right ventricular dilatation, tricuspid annular systolic displacement (TAPSE) and inferior vena cava diameter (IVCD) were evaluated by echocardiography, and all the indexes were transformed into binary variables. According to the final clinical diagnosis and treatment results, the disease was divided into CPE group and pneumonia group. Binary Logistic regression model was used to screen independent influencing factors, and partial regression coefficient β value was used as a weight to assign a score, and a differential diagnosis model was established based on the total score. The predictive value of the model was evaluated by the receiver operating characteristic curve (ROC) and area under curve (AUC). After the model was built, 30 patients with CPE or pneumonia were independently collected by ultrasonographer C as external validation data, which were included in the model to draw ROC curve and evaluate the differential diagnosis efficiency of the model. The consistencies between ultrasonographer A and B, A and C in observing lung ultrasound were explored.Results:A total of 743 patients from 43 clinical departments were included, including 246 cases in CPE group and 497 cases in pneumonia group. Multivariate logistic regression analysis showed that bilateral lung continuous B-profile, bilateral lung symmetric B-profile, ≥1 pleural effusion area, LVEF<50%, E/e′>14 were the risk factors for CPE (all OR>1, P<0.05), and ≥1 consolidation area and ≥1 pleural sliding disappearance area were the protective factors for CPE (all OR>1, P<0.05). The sensitivity, specificity and AUC of combined cardio-pulmonary ultrasound index β value weight score in the differential diagnosis of CPE and pneumonia were 0.939, 0.956 and 0.986, respectively. The AUC of external validation data was 0.904. Ultrasonographer A and B, A and C had good consistency in the interpretation of lung ultrasound signs ( P<0.05). Conclusions:The differential diagnosis model based on combined cardio-pulmonary ultrasound indexes has high differential diagnosis efficiency for CPE and pneumonia, and can be used in bedside cardio-pulmonary ultrasound practice.
ABSTRACT
Objective:To analyze the factors influencing the difference in location of cricothyroid membrane between traditional surface palpation and ultrasonic biplane.Methods:One hundred and seven subjects of both sexes, aged 18 yr, underwent neck ultrasound examination in our hospital from August 2021 to December 2021, were selected.The structure of cervical airway was observed by ultrasound.The subjects in whom the structure of cricothyroid membrane was clearly shown were selected.The middle point of cricothyroid membrane was located by otorhinolaryngologist using surface palpation method and by ultrasonic doctor using ultrasonic biplane method.The distance between two positioning points was measured by a ruler.The subjects were divided into accurate group (distance between two points≤3 mm) and difference group (distance between two points>3 mm). The distance between cricoid cartilage and thyroid cartilage (spacing of cricoid cartilage and thyroid cartilage) and distance between the midpoint of cricothyroid membrane and skin (spacing of cricothyroid membrane and skin) were measured by ultrasound.The neck length and the maximum submaxillary distance in head up were measured by a ruler.The factors influencing the difference in location between the two methods were analyzed by multivariate logistic regression.Results:One hundred and four subjects with clear cricoid cartilage and cricothyroid membrane under ultrasound were selected.There were significant differences in the ratio of gender, body mass index (BMI), cricothyroid membrane-skin distance, neck length, and maximum submandibular distance between the two groups ( P<0.05). Multivariate logistic analysis showed that female ( OR=9.091, P<0.001), BMI ( OR=11.214, P=0.001) and increased cricothyroid membrane-skin distance ( OR=5.649, P=0.015) were the factors influencing the difference in location between the two cricothyroid membrane localization methods. Conclusions:Female, obesity (BMI>28.0 kg/m 2) and increased distance between cricothyroid membrane and skin are the factors affecting the difference in location of cricothyroid membrane between ultrasonic biplane method and surface palpation method, and bedside ultrasound is recommended for location in those with the factors mentioned above.
ABSTRACT
Objective:To investigate the clinical safety and efficacy of tirofiban in the treatment of hemiplegic stroke warning syndrome.Methods:Patients with hemiplegic stroke warning syndrome admitted to Jining First People's Hospital without receiving intravenous thrombolysis from January 2018 to May 2020 were enrolled retrospectively. Some patients were given tirofiban intravenous infusion for at least 24 h in acute phase, then received oral antiplatelet therapy (tirofiban group); some only received aspirin+ clopidogrel dual antiplatelet therapy (control group). The primary endpoint was muscle strength at the paralytic side and National Institutes of Health Stroke Scale (NIHSS) score at day 7 after onset. The secondary endpoint was the modified Rankin Scale (mRS) score at 3 months after onset, and ≤2 was defined as good clinical outcome. The safety endpoint was the bleeding events during treatment. Multivariate logistic regression analysis was used to determine the independent influencing factors of clinical outcome. Results:A total of 30 patients with hemiplegic stroke warning syndrome were enrolled, including 19 (63.3%) in the tirofiban group and 11 (36.7%) in the control group. There was no significant difference in baseline clinical data between the two groups, and no drug-related bleeding complications occurred during treatment. The muscle strength at paralytic side and NIHSS score at day 7 after onset, NIHSS score at discharge and good clinical outcome rate at 3 months in the tirofiban group were significantly better than those in the control group, and the differences were statistically significant (all P<0.05). Multivariate logistic regression analysis showed that tirofiban was an independent protective factor for good outcome after adjusting the NIHSS score at the beginning of treatment (odds ratio 0.040, 95% confidence interval 0.040-0.449; P=0.009). Conclusions:Tirofiban is safe and effective in the treatment of patients with hemiplegic stroke warning syndrome in acute phase. It can effectively block the progress of the disease, improve the outcome of patients, and will not increase the risk of bleeding.
ABSTRACT
Objective To compare the accuracy of inferior vena cava (IVC) ultrasound,central venous pressure (CVP) and pulse indicator continuous cardiac output (PiCCO) in predicting fluid responsiveness in septic shock patients with myocardial depression.Methods Fifty patients with septic shock complicated with myocardial depression,aged > 18 yr,were enrolled in the study.The method for fluid replacement test was as follows:0.9% sodium chloride injectionor lactated Ringer's solution 500 ml was intravenously infused over 20 min,and positive fluid responsiveness was defined as an increase in PiCCO-monitored CO> 10% after fluid replacement.Patients were divided into positive fluid responsiveness group and negative fluid responsiveness group according to the fluid replacement test.PiCCO was used to monitor stroke volume (SV),stroke volume variation (SVV) and pulse pressure variability (PPV) before fluid replacement,CVP was measured,and the diameter of IVC (d-IVC) and variability of IVC (v-IVC) were measured by bedside ultrasound.The receiver operating characteristic curve was drawn to evaluate the accuracy of each index in predicting fluid responsiveness.Results Compared with negative fluid responsiveness group,d-IVC was significantly decreased and v-IVC,SVV and PPV were increased before fluid replacement in positive fluid responsiveness group (P<0.01).Three point five mmHg,14.5 mm,16.5%,17.0% and 11.5% were selected as the cutoff value for CVP,d-IVC,v-IVC,SVV and PPV,respectively.The sensitivity of CVP,d-IVC,v-IVC,SVV and PPV in predicting fluid responsiveness was 100%,92%,80%,44% and 68%,respectively,and the specificity was 28%,80%,72%,100% and 72%,respectively,and the area under the receiver operating characteristic curve (95% confidence interval) was 0.609 (0.450-0.768),0.862 (0.750-0.974),0.777 (0.642-0.911),0.734 (0.596-0.873) and 0.733 (0.594-0.872),respectively.Conclusion PiCCO and IVC ultrasound provide higher accuracy in predicting fluid responsiveness in septic shock patients with myocardial depression,and IVC ultrasound is more superior because of non-invasive examination.
ABSTRACT
Objective To compare the accuracy of the lung ultrasound and pulse indicator continuous cardiac output (PiCCO) in predicting volume responsiveness in septic shock patients with myocardial suppression.Methods Fifty patients of both sexes with septic shock complicated with myocardial depression,aged ≥ 18 yr,were enrolled in the study.The method for fluid replacement test was as follows:0.9% sodium chloride injection or lactated Ringer's solution 500 ml was rapidly infused intravenously.PiCCO was used to monitor cardiac output,stroke volume,extravascular lung water index (EVLWI),pulmonary vascular penetration index (PVPI),intra-thoracic blood volume index and global end-diastolic volume index.The chest wall was scanned by ultrasound and the lung ultrasound score (LUS) was assessed.Positive fluid responsiveness was defined as an increase in PiCCO-monitored cardiac output> 10% after fluid replacement.Patients were divided into positive fluid responsiveness group and negative fluid responsiveness group according to the results of fluid resuscitation test.The receiver operating characteristic (ROC) curve was drawn to evaluate the accuracy of each index in predicting fluid responsiveness.Results Compared with negative fluid responsiveness group,EVLWI,PVPI and LUS were significantly decreased,the number of patients in whom the bilateral anterior chest wall presented as B-line was increased in positive fluid responsiveness group (P<0.01).The area under the ROC curve and 95% confidence interval of LUS in predicting volume responsiveness was 0.836 (0.720-0.952),the cutoff value was 14.5 points,sensitivity 88%,and specificity 72%.The area under the ROC curve and 95% confidence interval of EVLWI in predicting volume responsiveness was 0.818 (0.701-0.936),the cutoff value was 9.6 ml/kg,sensitivity 84%,and specificity 72%.The area under the ROC curve and 95% confidence interval of PVPI in predicting volume responsiveness was 0.720 (0.575-0.865),the cutoff value was 1.55,sensitivity 92%,and specificity 52%.Conclusion The lung ultrasound and PiCCO produce higher accuracy in predicting volume responsiveness in septic shock patients with myocardial suppression;LUS has more advantages due to non-invasive examination.
ABSTRACT
Objective@#To evaluate the accuracy of trans-xiphoid inferior vena cava diameter variation (v-IVCTX), trans-liver inferior vena cava diameter variation (v-IVCTL), internal jugular vein diameter variation (v-IJV) and femoral vein diameter variation (v-FV) in predicting the fluid responsiveness in the patients with septic shock complicated with myocardial injury.@*Methods@#Fifty patients with septic shock complicated with myocardial depression admitted to intensive care unit of our hospital, aged ≥18 yr, were selected.The hemodynamics was monitored by PiCCO.Cardiac output (CO) and stroke volume were measured, and v-IVCTX, v-IVCTL, v-IJV and v-FV were measured by ultrasound and then calculated.Fluid replacement test was performed after meeting the standard of fluid resuscitation, and positive fluid responsiveness was defined as increase in CO after volume expansion>10%.Patients were divided into positive fluid responsiveness group and negative fluid responsiveness group.The receiver operating characteristic curve was drawn to evaluate the accuracy of the respiratory variation of each vein diameter in predicting fluid responsiveness.@*Results@#Compared with negative fluid responsiveness group, v-IVCTX, v-IVCTL and v-IJV were significantly increased (P<0.05), and no significant change was found in v-FV, CO or stroke volume in positive fluid responsiveness group (P>0.05). The cutoff value of v-IVCTX, v-IVCTL and v-IJV in predicting fluid responsiveness was 16.5%, 14.5% and 12%, respectively, the sensitivity was 80%, 76% and 84%, respectively, and the specificity was 72%, 64% and 44%, respectively.The area under the curve (95% confidence interval) of v-IVCTX, v-IVCTL and v-IJV was 0.777 (0.642-0.911), 0.741 (0.605-0.876), and 0.694 (0.549-0.838), respectively.@*Conclusion@#v-IVCTX and v-IVCTL both can predict the fluid responsiveness in the patients with septic shock complicated with myocardial injury.
ABSTRACT
Objective To evaluate the accuracy of trans-xiphoid inferior vena cava diameter variation (v-IVCTX),trans-liver inferior vena cava diameter variation (v-IVCTL),internal jugular vein diameter variation (v-IJV) and femoral vein diameter variation (v-FV) in predicting the fluid responsiveness in the patients with septic shock complicated with myocardial injury.Methods Fifty patients with septic shock complicated with myocardial depression admitted to intensive care unit of our hospital,aged ≥ 18 yr,were selected.The hemodynamics was monitored by PiCCO.Cardiac output (CO) and stroke volume were measured,and v-IVCTx,v-IVCTL,v-IJV and v-FV were measured by ultrasound and then calculated.Fluid replacement test was performed after meeting the standard of fluid resuscitation,and positive fluid responsiveness was defined as increase in CO after volume expansion> 10%.Patients were divided into positive fluid responsiveness group and negative fluid responsiveness group.The receiver operating characteristic curve was drawn to evaluate the accuracy of the respiratory variation of each vein diameter in predicting fluid responsiveness.Results Compared with negative fluid responsiveness group,v-IVCTx,v-IVCTL and v-IJV were significantly increased (P<0.05),and no significant change was found in v-FV,CO or stroke volume in positive fluid responsiveness group (P>0.05).The cutoff value of v-IVCTx,v-IVCTLand v-IJV in predicting fluid responsiveness was 16.5%,14.5% and 12%,respectively,the sensitivity was 80%,76% and 84%,respectively,and the specificity was 72%,64% and 44%,respectively.The area under the curve (95% confidence interval) of v-IVCTx,v-IVCTL and v-IJV was 0.777 (0.642-0.911),0.741 (0.605-0.876),and 0.694 (0.549-0.838),respectively.Conclusion v-IVCTx and v-IVCTL both can predict the fluid responsiveness in the patients with septic shock complicated with myocardial injury.