ABSTRACT
Objective:To make an individual phantom that was printed by using three dimension(3D)technique,which could reflect the real situation of patient,and to analyze the computed tomography(CT)value and dose distribution of radiotherapy on each organ of the inside of the 3D-printed individual phantom.Methods:According to the localization of CT image of the patient,the empty shell of 3D structure of each organ were reconstructed and printed by using 3D technique.The CT value was used as basis to select the equivalent material of each organ to perform fill,which could obtain the individual phantom of chest that could appear the structural characteristics of patient.The treatment plan of patients were included in treatment plan group,and the plans which were transplanted to 3D-printed individual phantom from treatment plan of patients were included in phantom plan group.The dosimetric parameters of the plans of two groups were compared.Results:The average CT values of left and right lung,soft tissue,cancellous bone,compact bone and heart of the phantom plan group were respectively-709,-737,14,144,760 and 28 HU.The errors of the all CT values between phantom images and located images of patients were less than 16.7%.The exposure doses of normal tissues of radiotherapy plans on the images of two groups could meet the clinical requirements.The minimum dose(Dmin),mean dose(Dmean),the corresponding doses of 98%,50% and 2% target volumes(D98%,D50% and D2%),conformity index(CI),homogeneity index(HI),monitor unit(MU)of dosimetric parameters of the target region could meet the clinical requirements without statistically significant differences.There was significant differences in the maximum dose(Dmax)of the target region(t=2.678,P<0.05).Among of these Dmax values,the Dmax value of phantom plan group was larger,which was(56.97±0.32)Gy.Conclusion:The CT value,tissue structure and spatial distribution of the phantom,which is finally designed,can emulate the chest of human body in radiotherapy.It has verified the feasibility that 3D-printed phantom is applied in measuring dose in the quality assurance of radiotherapy.
ABSTRACT
@#<b>Objective</b> To conduct experimental analysis of clinical applicability of a homemade phantom which is equivalent to multiple tissue densities of human body. <b>Methods</b> Materials with densities close to bone, lung, cavity, and soft tissue were manufactured and combined to obtain a homemade in homogeneous phantom. The electron density of equivalent materials was compared with the organs. Ten lung cancer patients in our department were recruited for dose verification of intensity modulated radiation therapy in the homemade phantom and solid-water phantom. The two phantoms were compared for characteristics in dose verification, and the dosimetric differences of the homemade phantom between the calculated values on treatment planning systemand measured values were statistically analyzed by SPSS 21.0 software. <b>Results</b> In the dose verification, the gamma pass rates (3 mm/3%) were more than 90% using both the homemade phantom and solid-water phantom. The measured values in homemade phantom were larger than those in solid-water phantom, and the maximum deviation was 11.5%. The AD and RD values of gamma pass rate in dose verification showed no significant differences between the two phantoms (<i>P</i> > 0.05). <b>Conclusion</b> The homemade phantom meets the accuracy requirement of clinical application and can be used in dose verification of intensity modulated radiation therapy plan.
ABSTRACT
Objective To investigate the inhibitory effect and mechanism of temozolomide on migration and invasion of U251 human glioma cells enhanced by plumbagin. Methods CCK-8 method was used to study the effects of plumbagin, temozolomide and plumbagin+temozolomide on the proliferation of glioma U251 cells. Cell scratch test was used to detect the migration of U251 cells in the control (DMSO), plumbagin, temozolomide and plumbagin+temozolomide groups for 48h. Transwell assay was used to detect the effect of the combination therapy on the invasion of U251 cells. Western blot was used to detect the relative expression levels of E-cadherin in three groups. Results CCK-8 showed that the proliferation inhibition rate of U251 cells treated with plumbagin (1.25 μmol/L) combined with temozolomide (200 μmol/L) for 48h was 75.69%, significantly higher than that treated with plumbagin alone (P=0.012) or temozolomide alone (P=0.034). Cell scratch assay showed that the combination of plumbagin and temozolomide could significantly enhance the inhibition effect of temozolomide on the migration of U251 cells (P=0.023). Transwell assay showed that the invasion ability of U251 cells was significantly decreased after the combination therapy (P < 0.05). The protein expression of E-cadherin in the combination group was significantly higher than those in plumbagin or temozolomide groups (P < 0.05). Conclusion Plumbagin combined with temozolomide can inhibit the migration and invasion of glioma cells and enhance the sensitivity of glioma cells to temozolomide. And the effect is achieved by the protein expression of E-cadherin.
ABSTRACT
Traditional Chinese Medicine (TCM) has become an important part of the health system in the Sultanate of Oman. Although there is no independent law, the local health department has implemented the administrative measures such as the admittance assessment system of TCM doctors and the standardized examination and approval of TCM clinics. The development of TCM in the Sultanate of Oman is supported by the policies of the two governments, with the characteristics likemedical cooperation starting with high-level personnel, the cooperation in economy, trade and medical treatment, TCM and local traditional medicine showing inclusive with good base, and the advantages of TCM theory and treatment meeting the needs of the local medical market. The prospect of cooperation in TCM market is broad. It is suggested that the local government should promote the legislation of traditional medicine and improve the admittance system of practitioners. China needs to promote the formulation of international standards of TCM and optimize the cooperation platform of TCM by using Internet and other technologies. The practitioners in China need to carry out medical activities on the premise of understanding and respecting the local cultural background.In order to promote the development of TCM in Arab countries, the Sultanate of Oman will radiate the whole Middle East through the above strategies.
ABSTRACT
Objective To investigate the repeatability of precise radiotherapy placement of self-made adjustable angle wedge plate,negative pressure vacuum pad and conmon soft pillow,corresponding to 3 groups.The study is demonstrated with a thermoplastic membrane immobilization technology in kyphotic deformity patients with head and neck cancer (including primary and secondary),respectively.Methods From Jun 2014 to Apr 2016,48 cases of severe head and neck cancer patients received radiotherapy humpback who were randomly divided into 3 groups.Combined with thermoplastic head and neck shoulder film position fixation,the right foot direction at the end of the skull styloid process layer center was set as a reference point.On the left foot at the end of the direction of styloid process layer center,localization of the origin of the coordinate system in patients around the head and foot,dorsoventrally (x,y,z) analysis of the direction change of position measurement was performed.Results There was no significant difference between the adjustable angle wedge plate and negative pressure vacuum pad groups of the coordinate system (P > 0.05).Compared with common soft pillow group,three dimensional positioning errors and three dimensional coordinate system transfer errors of the adjustable angle wedge plate and negative pressure vacuum pad groups were statistically significantly different (t =-6.99 to-2.69,-5.13 to-2.71,P<0.05).Conclusions The self-made adjustable angle wedge plate has good repeatability,saves time and money,is simple and durable on precise radiotherapy positioning of kyphotic deformity patients with head and neck cancer.
ABSTRACT
Objective To compare the repeatability of radiotherapy placement between negative pressure vacuum pad (A group) and common soft pillow (B group) combined with a thermoplastic membrane immobilization technology in severe kyphosis patients with head and neck cancer.Methods From September 2013 to December 2014,22 cases of severe kyphosis patients with primary or secondary head and neck cancer who received radiotherapy were randomly divided into group A and group B.Padding waist hips with negative pressure vacuum pad and ordinary soft pillow were used so that the patients could lay in CT-Sim bed,and the head cushion was set on the headrest.After the fixing of thermoplastic head and neck shoulder membrane,CT-Sim was located.Every five times of radiotherapy were accompanied by CT-Sim school position once.In the direction of the last layer of right styloid process center point as the reference point,CT-sim software was used to measure the location change with left and right sides,head,and under direction (x,y,z,respectively) in patients,and the data were analyzed.Results Group A significantly reduced the osseous placement error between tags compared with group B (P < 0.05).The average placement errors were as follows,x:(0.68±0.14) mm vs (1.15±0.77) mm,y:(0.48±0.23) mm vs (1.49±1.24) mm,z:(0.76±0.54) mm vs (2.11±1.02) mm,while the average transfer errors were as follows,x:(0.70±0.21) mm vs (1.15±0.93) mm,y:(0.50±0.31) mm vs (1.50±1.28) mm,z:(0.85±0.26) mm vs (1.77±0.88) mm.Conclusion Vacuum suction pad combined with thermoplastic membrane has good repeatability on radiotherapy positioning for severe kyphosis patients with head and neck cancer.
ABSTRACT
Objective Objective Structured Clinical Examination (OSCE) is one of the most important methods for evalua-ting the medical students′clinical ability .The aim of this study was to analyze the value of OSCE on practice examination in the depart -ment of cardiothoracic surgery . Methods Through the use of standardized patients and the six-station clinical examination , we as-sessed the clinical skills of interns in the department of cardiothoracic surgery . Results OSCE could appraise interns′clinical ability objectively and accurately , which obtained the recognition from students . Conclusion OSCE is applicable to the clinical skills tes-ting in the department of cardiothoracic surgery .
ABSTRACT
Objective A comparative study of clinical factors and dose-volume histogram (DVH)parameters on the impact of radiation pneumonitis occurred in the three-dimensional conformal radiotherapy of lung cancer (lung target)and mediastinal tumors and esophageal (mediastinal target).Methods Review 83cases lung cancer,mediastinal tumors and esophageal patients,and analyzed with chi-square tests on the correlation of the clinical factors (gender,age,tumor location,stage,chemotherapy) with radiation pneumonitis;have relevance analysis between the DVH parameters of two targets and radiation pneumonitis; lung target and mediastinal target volume DVH parameters compared to the t-test.Results ≥2 radiation pneumonitis was 36.5 %.≥2 radiation pneumonitis occurred in various clinical factors had no significant effect.DVH parameters of the two targets,V5,V10,V20,V30,whole lung dose (MLD) were significantly related to RP.Two targets of RP patients V5 [(50.9±17.8) %,(69.9±20.4) %],V10 [(38.6±15.2) %,(53.5±18.8) %] were statistically significant by t-test (t =2.434,P < 0.05),while V20 (t =0.388,P > 0.05),V30 (t =0.005,P > 0.05) and MLD (t =0.138,P >0.05) were no significant difference (P > 0.05),so the same results with the two targets of patients without RP obtained.Conclusion In the lung target and mediastinal target of radiotherapy radiation pneumonitis is related with DVH parameters,especially V20,V30 and MLD impact on the occurrence of RP.
ABSTRACT
Objective To observe the two different wetting fluid in airway humidification of patients with mechanical ventilation.Methods 40 patients with mechanical ventilation after cardiac surgery in our hospital from January to April,2009,were divided randomly into group A and group B,group A was given 0.45% sodium chloride solution 100ml plus ambroxol 15mg as airway humidification fluid,group B was given sterile water for injection100 ml plus ambroxol 15mg as airway humidification liquid.The amount of sputum aspiration,color,viscosity,the body temperature of patients,the lungs auscultation and chest X-ray were observed.Results No statistical difference was seen in sputum volume,color,viscosity,the body temperature of patients,lungs auscultation as well as chest X ray after mechanical ventilation for 4 hours,8 hours,16 hours,24 hours,1~2 d,3~5 d,6~7 d.No statistical difference was also seen in auscultation of the lung after mechanical ventilation for 4 hours,16 hours,24 hours,1~2 d,3~5 d,6~7 d.But auscultation of the lung in group B was better than that of group A after mechanical ventilation for 8 hours.Conclusions No sufficient fact can prove that different effect exists between 100 ml 0.45% sodium chloride solution plus ambroxol 15mg and 100 ml sterile water for injection plus ambroxol 15mg as airway humidification fluid during mechanical ventilation.
ABSTRACT
SAαt2,6 and SAα2,3 linked sialic acid molecules on epithelial cell membrane served as receptors for influenza virus, which axe specifically recognized by human and avian influenza viruses, respectively. The distribution of these two species of sialic acids in human respiratory tract from different anatomical sites and different age groups was investigated. The results showed that SAα2,3Gal species was prevalent in respiratory bronchiole and lung alveolar epithelium, but was infiequent in trachea, bronchus and bronchiole. On the contrary, the SAα2,6Gal species was more common in the trachea and bronchus and to a lesser degree in the alveolar epithelium. When compared the expression levels of SAα2,6Gal and α2,3Gal in the respiratory tract among different age groups, no significant difference was found. In the ex vivo H5N1 virus infection study, alveolus epithelium were found to be more susceptible to avian influenza than trachea and bronchus epithelial cells. These results suggest that the human respiratory tract, to some extent, is permissive for avian influenza viruses. The currently-observed limited human to human transmission of H5N1 virus may be associated with the different abundance of SAα2,3Gal linkages in human upper respiratory tract among individuals.