ABSTRACT
[This corrects the article DOI: 10.1016/j.apsb.2021.04.013.].
ABSTRACT
[This corrects the article DOI: 10.1016/j.apsb.2021.04.013.].
ABSTRACT
Advanced radiotherapy technology enables the dose to more accurately conform to the tumor target area of the patient, providing accurate treatment for the patient, but the gradient of the patient's radiation dose at the tumor edge is getting larger, which putting forward higher requirements for radiotherapy dose verification. The dose verification system software KylinRay-Dose4D can verify the patient's pre-treatment plan and the in vivo/on-line dose during the patient's treatment, providing important reference for the physicist to modify the radiotherapy plan and ensuring that the patient receives accurate treatment. This study introduces the overall design and key technologies of KylinRay-Dose4D, and tests the pre-treatment plan dose checking calculation and 2D/3D dose verification through clinical cases. The test results showed that the 2D/3D gamma pass rate (3 mm/3%) of KylinRay-Dose4D reconstructed dose compared with TPS plan dose and measured dose is larger than 95%, which indicating that the reconstructed dose of KylinRay-Dose4D meets the requirement of clinical application.
Subject(s)
Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Software , Neoplasms , Phantoms, Imaging , Radiometry/methodsABSTRACT
Vascular smooth muscle cell (VSMC) migration plays a critical role in the pathogenesis of many cardiovascular diseases. We recently showed that TMEM16A is involved in hypertension-induced cerebrovascular remodeling. However, it is unclear whether this effect is related to the regulation of VSMC migration. Here, we investigated whether and how TMEM16A contributes to migration in basilar artery smooth muscle cells (BASMCs). We observed that AngII increased the migration of cultured BASMCs, which was markedly inhibited by overexpression of TMEM16A. TMEM16A overexpression inhibited AngII-induced RhoA/ROCK2 activation, and myosin light chain phosphatase (MLCP) and myosin light chain (MLC20) phosphorylation. But AngII-induced myosin light chain kinase (MLCK) activation was not affected by TMEM16A. Furthermore, a suppressed activation of integrin
ABSTRACT
KylinRay-IMRT is the advanced radiotherapy treatment planning module of accurate radiotherapy system (KylinRay) aiming to provide accurate and efficient plan design platform. In this paper the system design, main functions and key technologies of KylinRay-IMRT were introduced. KylinRay-IMRT supports three dimensional conformal radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT) and many other types of treatment plan design with function modules including patient data management, image registration and fusion, image contouring, image three dimensional reconstruction and visualization, three dimensional conformal radiotherapy planning, intensity modulated radiotherapy planning, plan evaluation and comparison, and report print. KylinRay-IMRT has been tested by the national standard YY/T 0889-2013, the results showed that the performance of KylinRay-IMRT can fully meet the standard requirements.