Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Article in Chinese | WPRIM | ID: wpr-438044

ABSTRACT

Objective To investigate the clinical diagnosis value of parathyroid hormone and bone transport indexes detection in renal osteodystrophy in maintenance hemodialysis (MHD) patients.Methods Seventy-six cases of MHD patients were selected as observation group,and 60 cases of healthy people were selected as control group.Serum intact parathyroid hormone (iPTH),parathyroid hormone 7-84 (PTH7-84),bone alkaline phosphatase (BALP) and osteocalcin (OC) were detected by enzyme-linked immunosorbent assay,and iPTH/PTH7-84 was calculated.Results Urea nitrogen,creatinine,phosphorus,alkaline phosphatase,BALP,iPTH,PTH7-84 and OC in observation group were significantly higher than those in control group (P < 0.01 or < 0.05).But calcium and albumin levels in observation group were significantly lower than those in control group (P < 0.01).There was positive correlation between iPTH and BALP,OC,PTH7-84 (r =0.419,0.457,0.662;P < 0.01);and there was positive correlation between PTH7-84 and BALP,OC (r =0.358,0.312;P < 0.01).In observation group,the patients were divided into < 300 ng/L group (36 cases) and ≥ 300 ng/L group (40 cases) according to the levels of iPTH.The age in < 300 ng/L group was significantly higher than that in ≥300 ng/L group [(69.6 ± 11.2) years vs.(59.4 ± 10.1) years,P< 0.05].OC and BALP levels in < 300 ng/L group were (9.32 ± 2.03) ng/L and (14.55 ± 9.01) U/L,and those in ≥300 ng/L group were (10.49 ± 2.76) ng/L and (23.81 ± 15.92) U/L,and there were significant differences between the 2 groups (P<0.01 or <0.05).iPTH/PTH7-84 in <300 ng/L group was 0.57 ± 0.39,and that in ≥300 ng/L group was 1.12 ±0.58,and there was significant difference between the 2 groups (P < 0.01).Conclusion Detection of serum BALP,OC,iPTH and PTH7-84 can reflect the actual situation of bone transport in MHD patients,and differentiate the type of renal osteodystrophy,which is a non-invasive diagnosis indicator of renal osteodystrophy and could be used to guide clinical treatment.

2.
Article in Chinese | WPRIM | ID: wpr-439606

ABSTRACT

Objective To compare the sensitivity and specificity of different fluorescent quantitation polymerase chain reaction(PCR) for genes detection of Streptococcus pneumonia.Methods By designing five sets of fluorescent quantitation PCR primers targeting different genes of Streptococcus pneumonia (lytA,ply,spn9802,psaA,cspA),the sensitivity and specificity of fluorescent quantitation PCR was determined through detecting 37 strains of Streptococcus pneumonia and 28 strains of non-Streptococcus pneumonia,as well as 80 sputum specimens from suspected pneumonia cases.Results These five primers had excellent sensitivity with 90% amplification efficiency through analysis of the standard curve.The change of Ct value was less than 0.5,indicating that these five primers have good stability.By detecting 37 strains of Streptococcus pneumonia and 28 strains of non-Streptococcus pneumonia,it showed that the specificity of lytA,ply and spn9802 was better than the other two primers (positive rate and negative rate was all 100%).But the detection limit of lytA,ply was one order of magnitude than spn9802 (101 CFU/ml vs.102 CFU/ml).The specificity of psaA and cspA was worse [negative rate of psaA was 89% (25/28),positive rate of cspA was 97% (36/37)].By detecting 80 sputum specimens from suspected pneumonia cases,it showed that the specificity of fluorescent quantitation PCR were better than the bacterial culture.The specificity of lytA and ply was the best two [positive rate:92.50%(74/80),90.00%(72/80)],and next was spn9802 [86.25%(69/80)],the specificity ofpsaA and cspA was the worst two for detection [76.25%(61/80) and 78.75%(63/80)].Conclusions The sensitivity and specificity of fluorescent quantitation PCR genes used in clinic for detecting Streptococcus pneumonia is different.LytA and ply are the best primers in specificity,next is spn9802,and psaA and cspA are the worst primers for in specificity detection.

SELECTION OF CITATIONS
SEARCH DETAIL