1.
China Occupational Medicine ; (6): 54-59, 2024.
Article in Chinese | WPRIM | ID: wpr-1038726

ABSTRACT

ObjectiveTo understand the monitoring result of occupational hazard in the workplace of key industries in Guangdong Province from 2020 to 2023. Methods The data of occupational hazards in the workplace of 20 key industries in Guangdong Province from 2020 to 2023 were collected from the “Workplace Occupational Hazard Monitoring System” of the Chinese Disease Prevention and Control System subsystem. The monitoring result of occupational hazard factors, occupational health training, occupational health examination, occupational protection, detection of occupational hazardous agents such as dust, chemical substances and noise were analyzed. Results A total of 13 058 enterprises from key industries were recruited as the monitoring subjects in Guangdong Province. There were 290 large-, 1 342 medium-, 7 635 small-, and 3 791 micro-enterprises, with small and micro-enterprises accounting for 58.5% and 29.0% of the total, respectively. A total of 7 542 enterprises exceeded the national standard in the detection of occupational hazards, with a rate of 57.8%. A total of 1 942 517 workers from 13 058 enterprises were recruited, with 835 567 workers were exposed to occupational hazards, with a rate of 43.0%. The rate of occupational health training for enterprise leaders, occupational health management personnel, and workers was 71.9%, 73.8%, and 86.5%, respectively. The abnormal rate of occupational health examinations for workers exposed to noise, dust, and chemical agents was 2.0%, 0.6%, and 1.0%, respectively. The distribution rate of dust masks, anti-poisoning masks or face masks, and noise prevention earplugs or earmuffs was 83.3%, 71.3%, and 77.8%, respectively. The rate of installation of dust prevention facilities, anti-poisoning facilities, and noise prevention facilities was 85.6%, 81.2%, and 50.1%, respectively. The rate of exceeded the national standard of dust, noise in the worksites/types and workplaces showed a decreasing trend year by year (all P<0.01), while the rate of exceeded the national standard of chemical agents in worksites/types and workplaces showed an increasing trend year by year in various occupational hazards (all P<0.01). Conclusion Occupational hazards in the workplace of key industries in Guangdong Province are relatively common. The proportion of workers exposed to occupational hazards is relatively high. It is necessary to further improve the use of noise prevention facilities and protective equipment, strengthen occupational health training for enterprises throughout the province and regularly monitor occupational hazards to reduce the risk of occupational diseases.

2.
China Occupational Medicine ; (6): 85-89, 2024.
Article in Chinese | WPRIM | ID: wpr-1038732

ABSTRACT

ObjectiveTo establish a method for the determination of 1,1,1,2-tetrachloroethane (TeCA) and 1,1,2,2-TeCA in human urine using liquid-liquid extraction-gas chromatography. Methods The 5.0 mL urine sample was mixed with 2.0 g anhydrous sodium sulfate and 5.0 mL ethyl acetate, then vortexed mixing. The 1.0 mL extraction was separated by 100% dimethylpolysiloxane capillary gas chromatography column, detected by flame ionization detector, and quantified by an external standard method. Results The linear ranges of 1,1,1,2-TeCA and 1,1,2,2-TeCA were 0.250-50.750 mg/L, with both correlation coefficients of >0.999 9. The detection limit of 1,1,1,2-TeCA in urine was 0.020 mg/L, and the lower limit of quantification was 0.060 mg/L. The average recovery was 88.02%-101.32%, and the within-run and between-run relative standard deviations (RSDs) were 0.11%-0.47% and 0.39%-1.09%, respectively. The detection limit of 1,1,2,2-TeCA in urine was 0.050 mg/L, and the lower limit of quantification was 0.150 mg/L. The average recovery was 93.42%-101.32%, and the within-run and between-run RSDs were 0.28%-1.04% and 0.50%-1.03%, respectively. Both the 1,1,1,2-TeCA and 1,1,2,2-TeCA cannot be stored at room temperature. The 1,1,2,2-TeCA can be stored at 4 ℃ for at least three days. At -20 ℃, the 1,1,1,2-TeCA can only be stored for one day, while 1,1,2,2-TeCA can be stored for at least five days. Conclusion This method has high sensitivity, good specificity, simple sample pretreatment, and more intuitive and reliable results. It can be used to determine the level of 1,1,1,2-TeCA and 1,1,2,2-TeCA in urine of occupational population.

3.
China Occupational Medicine ; (6): 325-329, 2023.
Article in Chinese | WPRIM | ID: wpr-1003862

ABSTRACT

Objective To establish a rapid qualitative analysis method for volatile organic components in chemicals. Methods Headspace gas chromatography-mass spectrometry was used to qualitatively determine 19 volatile organic components, including benzene, 1,2-dichloroethane, and n-hexane, in chemicals. Different sample amounts, heating temperatures, heating times, and sample volumes were analyzed to assess their effects on detection results and optimize sampling conditions. Results Based on the set chromatography, the optimal sampling process of this method was as follows: 5.0 g sample in a 20.0 mL headspace bottle, incubated at 40 ℃ for 30 minutes in a constant-temperature drying incubator, and a 1.00 mL headspace gas injection. The within-run and between-run relative standard deviations of all components ranged from 0.00% to 21.05% and 0.00% to 33.33%, respectively. The samples stored in sealed glass containers were stable at room temperature for at least 60 days. Conclusion This method offers simplicity, good reproducibility, and stability, making it suitable for rapid qualitative analysis of volatile organic components in chemicals.

4.
China Occupational Medicine ; (6): 441-446, 2023.
Article in Chinese | WPRIM | ID: wpr-1003882

ABSTRACT

Objective To establish a high performance liquid chromatography (HPLC) method for simultaneous determination of six aniline compounds (ADs) in workplace air. Methods GDH-1 air sampling tube was used to collect six co-existing ADs such as aniline, o-toluidine, N-methylaniline, m-methylaniline, p-methylaniline and N,N-dimethylaniline in the vapor and aerosol of workplace air. The samples were desorbed and eluted using a methanol solution containing 1.00% ammonia water, followed by separation on a C18 chromatographic column and detection using a diode array detector. Results The quantification range of the method was 0.19 -253.50 mg/L, with the correlation coefficient of 0.999 9 for all six ADs. The minimum detection range was 0.02-0.06 mg/m3, and the minimum quantitation range was 0.04-0.19 mg/m3 [both calculated for a 15.0 L sample with a desorption (elution) solution volume of 3.00 mL]. The average desorption and elution efficiencies were 92.15%-104.41% (silica gel) and 94.29%-104.29% (filter membrane). The intra-assay relative standard deviation (RSD) ranged from 0.90%-9.72% (silica gel) and 0.57%-6.96% (filter membrane). The inter-assay RSD ranged from 2.03%-9.78% (silica gel) and 2.50%-8.62% (filter membrane). The samples were stable at room temperature for seven days. Conclusion This method can be used for the simultaneous determination of six ADs in workplace air.

5.
China Occupational Medicine ; (6): 466-471, 2023.
Article in Chinese | WPRIM | ID: wpr-1003887

ABSTRACT

Objective To analyze the overall situation of regular monitoring of occupational hazards in enterprises in Guangdong Province in 2022. Methods Analysis and quality sampling from enterprises were conducted on the occupational hazard regular monitoring reports submitted by various occupational health institutions through the Guangdong Province Occupational Health Quality Control Platform for the year 2022. Results In 2022, a total of 40 129 enterprises in Guangdong Province conducted regular monitoring of occupational hazards, accounting for 5.9%. More than 4.85 million workers were enrolled, of which more than 1.99 million workers were exposed to occupational hazards, with an incidence of 41.1%. The incidence of exposure to chemicals, dust, and noise were 18.2%, 11.9%, and 23.5%, respectively. The incidence of exceeding national standard for chemical substances, dust and noise in enterprises were 2.7%, 3.3%, and 42.7%, respectively. The incidence of exceeding national standard for all occupational hazards increased with the scale of enterprises from micro, small, medium to large enterprises (29.1% vs 46.7% vs 61.3% vs 65.4%, all P<0.05). The top three key industries, with more enterprises exceeding national standard, were metal furniture manufacturing, wooden furniture manufacturing, and other metal daily necessities manufacturing. The concentration of 97 chemical hazardous agents such as silica dust and benzene in work site exceeded the national standard, but less than 1.0% chemical hazardous agents exceeded national standard in most of the chemical-exposed work site. The incidence of noise exceeding national standard was 45.4%, while the incidence of silica dust exceeding national standard was 17.3%. Conclusion The percentage of regular monitoring of occupational hazards in enterprises in Guangdong Province is relatively low. The main occupational hazard that exceeds the national standard was noise, indicating the need for special attention on noise protection in workplace.

6.
China Occupational Medicine ; (6): 181-184, 2023.
Article in Chinese | WPRIM | ID: wpr-996545

ABSTRACT

Objective: To establish a solvent desorption-gas chromatography method for determination of dimethyl carbonate (DMC) in workplace air. Methods: The air samples were collected using activated carbon tubes, desorbed by carbon disulfide, separated by dimethylpolysiloxane capillary columns, and detected by a flame ionization detector. Results: The linear range of DMC was 2.14 to 1.07×104 mg/L, and the correlation coefficient was greater than 0.999. The detection limit was 0.14 mg/L, the lower limit of quantification was 0.47 mg/L, the minimum detection concentration was 0.10 mg/m3, and the minimum quantification concentration was 0.32 mg/m3 (based on 1.5 L workplace air). The average desorption efficiency of the method was 96.2% to 102.0%. Both the within-run and between-run relative standard deviations were 0.9% to 2.3%. The samples could be stored for at least seven days at four celsius degree. Conclusion: This method shows high desorption efficiency, high sensitivity, good precision and is simple in using. It can be used for the determination of DMC in workplace air.

7.
China Occupational Medicine ; (6): 185-188, 2023.
Article in Chinese | WPRIM | ID: wpr-996546

ABSTRACT

Objective: To establish a solvent desorption-gas chromatography method for the determination of 1,1,2,2-tetrachloroethane and 1,1,1,2-tetrachloroethane in workplace air. Methods: The 1,1,2,2-tetrachloroethane and 1,1,1,2-tetrachloroethane in workplace air were collected using activated carbon tubes, desorbed with carbon disulfide, and separated and detected by gas chromatography. The quantifications were based on standard curves. Results: The linear ranges of 1,1,2,2-tetrachloroethane and 1,1,1,2-tetrachloroethane were 0.98-395.50 and 0.87-395.50 mg/L, respectively, with the correlation coefficient of 0.999 95. The detection limits were 0.29 and 0.26 mg/L, respectively. The average of desorption efficiency was 92.04%-104.67%. The within- and between-run relative standard deviations were 1.42%-2.09% and 1.63%-6.09%, respectively. The sampling efficiency was more than 98.00%. The samples could be stored at room temperature for at least 14 days. Conclusion: This method can be used in detection of 1,1,2,2-tetrachloroethane and 1,1,1,2-tetrachloroethane in workplace air.

8.
China Occupational Medicine ; (6): 712-716, 2023.
Article in Chinese | WPRIM | ID: wpr-1013312

ABSTRACT

{L-End}Objective To establish a method for the simultaneous determination of dimethyltin (DMT), trimethyltin (TMT), diethyltin (DET), and triethyltin (TET) in human whole blood using high performance liquid chromatography-inductively coupled plasma-mass spectrometry (ICP-MS). {L-End}Methods The 1.0 mL of blood was added with 4.0 mL 65% aqueous solution (containing 6% acetic acid), extracted and separated by C4 column (150 mm×3 mm×3 μm) using a mobile phase of methanol and 4% acetic acid aqueous solution (containing 0.25 mmol/L tropolone) at a volume ratio of 35∶65, and detected by ICP-MS. {L-End}Results The linear range of DMT, TMT, DET, and TET was 30.60-550.80, 29.00-522.00, 46.10-829.80, and 34.05-612.90 μg/L, respectively. All correlation coefficients were 0.999. The detection limit of DMT, TMT, DET and TET was 21.40, 20.30, 32.27 and 23.80 μg/L, respectively. The recovery rate was 81.9%-104.9%. The within-run and between-run relative standard deviation was 1.6%-6.9% and 0.1%-10.0%, respectively. The samples can be stored at -20 ℃ and 4 ℃ for at least three days. {L-End}Conclusion This method can be used for trace analysis of DMT, TMT, DET, and TET in whole blood.

9.
China Occupational Medicine ; (6): 339-342, 2020.
Article in Chinese | WPRIM | ID: wpr-881907

ABSTRACT

OBJECTIVE: To establish a method for simultaneous determination of chlorobenzene, p-dichlorobenzene and o-dichlorobenzene in workplace air by portable gas chromatography-mass spectrometry(GC-MS). METHODS: The portable GC-MS heat tracing sampling probe was used for sampling. Samples were separated with LTM DB-5 MS rapid chromatographic column. The qualitative analysis was based on retention times and characteristic ions, and the quantification was based on standard curves. RESULTS: The linear correlation coefficient of this method was higher than 0.999 6. The minimum detectable concentrations were 0.03, 0.03 and 0.06 mg/m~3, and the minimum quantification concentrations were 0.10, 0.10 and 0.20 mg/m~3. The recovery rates were 84.68%-92.61%, 86.27%-93.92% and 82.31%-92.36% respectively for three chlorobenzenes compounds. The within-run relative standard deviations(RSD) were 8.51%-9.34%, 7.93%-9.19%, 5.47%-7.48% respectively for three chlorobenzenes compounds, the between-run RSD were 7.29%-9.73%, 8.08%-10.04% and 5.19%-5.98% respectively for three chlorobenzenes compounds. CONCLUSION: The portable GC-MS could be used for qualitative and quantitative detection of three chlorobenzenes compounds in workplace air.

10.
China Occupational Medicine ; (6): 475-477, 2020.
Article in Chinese | WPRIM | ID: wpr-881928

ABSTRACT

OBJECTIVE: To establish a method of determination of difluorochloromethane in workplace air by direct sampling gas chromatography. METHODS: Difluorochloromethane in workplace air was collected with aluminum plastic composite film airbag and then directly injected. Difluorochloromethane was separated by DB-1 capillary column and detected with hydrogen flame ionization detector. RESULTS: Good linearity was obtained in the range of 1.50-15 042.90 mg/m~3 with the correlation coefficient of 0.999 96. The limit of detection was 1.26 mg/m~3 and the limit of quantitation was 3.78 mg/m~3. The minimum detection concentration was 1.26 mg/m~3 and the minimum quantification concentration was 3.78 mg/m~3. The standard recovery was 98.34%-99.19%. The within-run relative standard deviation(RSD) and the between-run RSD were 1.82%-3.72% and 2.17%-4.17%, respectively. The samples can be stored at room temperature for at least 7 days. CONCLUSION: This method is suitable for difluorochloromethane detection in workplace air.

11.
China Occupational Medicine ; (6): 572-577, 2020.
Article in Chinese | WPRIM | ID: wpr-881940

ABSTRACT

OBJECTIVE: To establish a method for simultaneous detection of 6 isomers of dimethylaniline(DMA) in workplace air by gas chromatography(GC). METHODS: The vapor and aerosol DMA in workplace air were collected by GDH-1 air sampling tube, and desorbed and eluted with absolute ethanol, then separated by a special capillary column for amines analysis, and finally detected by GC-flame ionization detector. RESULTS: The quantitative detection range of 6 isomers of DMA was 0.26-226.66 mg/L, with all the correlation coefficients greater than 0.999 00. The minimum detectable concentration was 0.01-0.02 mg/m~3, and the minimum quantification concentration was 0.04-0.05 mg/m~(3 )(15.00 L sample, 2.00 mL sample solution). The average desorption and elution efficiency was 92.48%-104.60%. The within-run relative standard deviations(RSD) was 0.31%-4.51%, and the between-run RSD was 1.23%-6.03%. The samples can be sealed and stored for more than 19 days at room temperature. CONCLUSION: The method is suitable for simultaneous detection of 6 isomers of DMA in workplace air.

12.
China Occupational Medicine ; (6): 578-581, 2020.
Article in Chinese | WPRIM | ID: wpr-881941

ABSTRACT

OBJECTIVE: To improve the standard detection method for acetaldehyde, butyraldehyde and isobutyraldehyde in the air of workplace. METHODS: Acetaldehyde, butyraldehyde and isobutyraldehyde in the air of workplace were collected using silica gel tube, desorbed with 45.0% ethanol, separated by a capillary column and detected by a flame ionization detector. RESULTS: The linear range of this method for detecting acetaldehyde, butyraldehyde and isobutyraldehyde were 1.57-1 568.00, 1.60-1 600.00 and 1.59-1 588.00 mg/L, respectively. All the correlation coefficients were greater than 0.999. The detection limits were 0.52, 0.46 and 0.54 mg/L, respectively. The desorption efficiency was 91.0%-103.0%. The within-run relative standard deviation(RSD) was 0.7%-1.7%.The between-run RSD was 2.0%-3.7%. The samples could be stored for at least 10 days at room temperature. CONCLUSION: This method can be used for simultaneous detection of acetaldehyde, butyraldehyde and isobutyraldehyde in the air of workplace.

13.
China Occupational Medicine ; (6): 225-232, 2019.
Article in Chinese | WPRIM | ID: wpr-881784

ABSTRACT

OBJECTIVE: To establish a method for simultaneous determination of 1,1,1-trichloroethane(TCA) and 1,1,2-TCA in the workplace air by solvent desorption-gas chromatography. METHODS: The 1,1,1-TCA and 1,1,2-TCA in the workplace air were collected by activated carbon tube and desorbed with carbon disulfide. They were separated with DB-1(100.0% dimethyl polysiloxane) capillary column and detected by flame ionization detector. RESULTS: The good linear ranges of 1,1,1-TCA and 1,1,2-TCA were 1.340-1.338×10~4 and 1.440-1.442×10~4 mg/L, respectively. The correlation coefficients were greater than 0.999, with the detection limits of 0.100 and 0.140 mg/L, respectively. The average desorption efficiencies of 1,1,1-TCA and 1,1,2-TCA were 98.6%-99.6% and 94.9%-96.2%. The within-run and between-run relative standard deviations were 0.4%-0.9% and 0.5%-1.1%, respectively. The samples could be stored at room temperature for at least 14 days. CONCLUSION: This method has high desorption efficiency and sensitivity, good precision and simple operation, which is suitable for simultaneous detection of 1,1,1-TCA and 1,1,2-TCA in the workplace air.

14.
China Occupational Medicine ; (6): 229-232, 2019.
Article in Chinese | WPRIM | ID: wpr-881785

ABSTRACT

OBJECTIVE: To establish a method for determination of N-methyl-2-pyrrolidone(NMP) in workplace air by solvent desorption-gas chromatography. METHODS: NMP in the workplace air was collected with activated carbon tube and desorbed with methanol ∶dichloromethane(5 ∶95, V/V). After desorption, it was separated by capillary column separation, and detected by flame ionization detector. RESULTS: The good linear concentration of NMP was 0.51-4 108.00 mg/L. The correlation coefficient was 0.999 9. The detection limit was 0.08 mg/L(calculated by 3 times of standard deviation). The average desorption efficiency was 101.68%-103.44%. The within-run and between-run relative standard deviations were 1.94%-3.97% and 0.97%-2.26%, respectively. The sample could be stored at room temperature for at least 14 days. CONCLUSION: The developed method is suitable for the determination of NMP in workplace air.

15.
China Occupational Medicine ; (6): 465-468, 2019.
Article in Chinese | WPRIM | ID: wpr-881822

ABSTRACT

OBJECTIVE: To establish a method for simultaneously detecting methyl methacrylate, ethyl methacrylate, n-propyl methacrylate and butyl methacrylate in workplace air by a portable gas chromatography-mass spectrometer(GC-MS) technique. METHODS: The portable GC-MS hand-held probe was used for sampling and detection. Samples were separated with DB-5 rapid chromatographic column in order to maintain retention time and characteristics of the ions, and quantified by standard curve method. RESULTS: The linear correlation of this method was higher than 0.999 0. The minimum detection concentration was 0.03-0.06 mg/m~3, and the minimum quantitation concentration was 0.10-0.20 mg/m~3. The standard recovery rate was 82.22%-91.24%. The within-run and the between-run relative standard deviation were 7.67%-14.63% and 10.40%-13.79% respectively. CONCLUSION: The portable GC-MS technique could be used for qualitative and quantitative detection of above-mentioned four methylacrylate compounds in workplace air.

16.
Zhonghua laodong weisheng zhiyebing zazhi ; Zhonghua laodong weisheng zhiyebing zazhi;(12): 384-389, 2019.
Article in Chinese | WPRIM | ID: wpr-805124

ABSTRACT

Objective@#To develop a solvent desorption-gas chromatography method for simultaneous determination of methyl methacrylate (MMA) , ethyl methacrylate (EMA) , n-propyl methacrylate (PMA) and butyl methacrylate (BMA) in workplace air.@*Methods@#MMA, EMA, PMA and BMA in workplace air were captured by charcoal tubes and desorbed with carbon disulfide, separated through capillary chromatographic column, and then analyzed by gas chromatography-flame ionization detector.@*Results@#The linear ranges of MMA, EMA, PMA and BMA were 0-8 305.00 mg/L, 0-9 080.50 mg/L, 0-8 899.00 mg/L and 0-8 371.00 mg/L respectively, and the related coefficients were between 0.999 96-0.999 98. The relative standard deviations (RSD) within the group were 0.56%-1.71%, 0.45%-1.65%, 0.51%-1.49% and 0.45%-1.50% respectively, and the RSD between the group were 1.14%-2.79%, 0.79%-2.13%, 0.93%-2.30% and 1.09%-2.84% respectively. The average desorption efficiencies were 95.76%-99.58%, 97.82%-102.28%, 98.55%-102.28%and 98.70%-102.40% respectively. The minimum quantification concentrations were 0.12 mg/m3, 0.10 mg/m3, 0.07 mg/m3 and 0.07 mg/m3 respectively (3.00 L sample) . The samples could be stored at room temperature for at least 7 days.@*Conclusion@#This method could be used for monitoring of MMA, EMA, PMA and BMA in workplace air.

17.
China Occupational Medicine ; (6): 91-94, 2018.
Article in Chinese | WPRIM | ID: wpr-881671

ABSTRACT

OBJECTIVE: To develop a solvent desorption-gas chromatography method for detecting ethylene glycol monopropyl ether( EGME) in workplace air. METHODS: EGME in workplace air was captured by charcoal tubes and desorbed by methanol-methylene chloride(5∶ 95,V/V),separated by capillary chromatographic column,and detected by flame ionization detector. RESULTS: The good linear range of EGME was 1. 37-1 913. 80 mg/L,and the correlation coefficient was 0. 999 90. The detection limit was 0. 06 mg/L. The minimum detectable concentration was 0. 02 mg/m3.The average desorption efficiency was 97. 81%-104. 70%. The within-run relative standard deviation( RSD) was 1. 94%-2. 99%,and the between-run RSD was 3. 24%-4. 53%. The samples could be stored at room temperature for at least 14 days. CONCLUSION: This method could be used for detection of EGME in workplace air.

18.
China Occupational Medicine ; (6): 214-218, 2018.
Article in Chinese | WPRIM | ID: wpr-881689

ABSTRACT

OBJECTIVE: To establish a method for simultaneous detection of 2-methoxyethoxy ethanol( 2-MEE) and2-ethoxyethoxy ethanol( 2-ETE) in workplace air by solvent desorption-gas chromatography. METHODS: The 2-MEE and 2-ETE in workplace air were collected by activated carbon tubes and desorbed with methanol-methylene chloride( 5 ∶ 95,V/V),then separated on DB-FFAP capillary chromatographic column,and finally detected using flame ionization detector.RESULTS: The 2-MEE and 2-ETE showed a good linear range in 2. 12-8 464. 00 and 2. 11-8 428. 00 mg/L respectively and the correlation coefficients was 0. 999 8. The minimum quantification limits were 0. 16 and 0. 20 mg/m~3 respectively( 3 L air sample). The average desorption efficiencies were 99. 33%-103. 72% and 99. 61%-104. 07% respectively. The withinrun relative standard deviations( RSDs) were 3. 68%-4. 73% and 3. 47%-4. 39% respectively,and the between-run RSDs were 4. 72%-6. 99% and 4. 77%-6. 28% respectively. The samples could be stored at room temperature for at least14 days. CONCLUSION: This method is simple,sensitive,precise and suitable for simultaneous detection of 2-MEE and 2-ETE in workplace air.

19.
China Occupational Medicine ; (6): 363-368, 2018.
Article in Chinese | WPRIM | ID: wpr-881710

ABSTRACT

OBJECTIVE: To explore the feasibility of simultaneous detection of 45 kinds of common organic compounds in workplace air by solvent desorption-gas chromatography method.METHODS: A total of 45 kinds of common organic compounds such as benzene,1,2-dichloroeyhane,n-hexane and trichloroethylene in workplace air were collected with activated carbon tube and desorbed with carbon disulfide,separated by capillary chromatographic column,and detected with flame ionization detector.RESULTS: There was good linear relationship in the selected range.The correlation coefficients was 0.999 92-0.999 99.The detection limit was 0.03-0.30 mg/L and the minimum detectable concentration range was 0.01-0.20 mg/m~3( sample volume was 3.00 L).The average desorption efficiencies was 75.4%-105.7%.The within-run and between-run relative standard deviations were 0.4%-6.7% and 1.8%-7.9%,respectively.The sampling efficiency was 91.9%-100.0%.CONCLUSION: The method is simple,high sensitivity and good precision,which can be used for simultaneous detection of 45 kinds of common coexisting organic compounds in workplace air.

20.
China Occupational Medicine ; (6): 369-372, 2018.
Article in Chinese | WPRIM | ID: wpr-881711

ABSTRACT

OBJECTIVE: To establish a method for simultaneous determination of 1,2-dichloropropane and 1,3-dichloropropane in workplace air by solvent desorption-gas chromatography.METHODS: The air samples were collected by activated carbon tube and desorbed with carbon disulfide,then separated by DB-1 capillary columns,and detected by gas chromatographic.RESULTS: The linear ranges of 1,2-dichloropropane and 1,3-dichloropropane were 1.16-17 400.00 mg/L and 1.19-17 850.00 mg/L of mass concentration,respectively.The correlation coefficient was 0.999 9,and the limit of detection was 0.07 mg/L.The average desorption efficiencies of 1,2-dichloropropane and 1,3-dichloropropane were 96.9%-98.2%and 95.8%-96.8%,respectively.The within-run relative standard deviation( RSD) was 0.4%-0.6%.The between-run RSD were 1.6%-3.2% and 1.2%-2.8% respectively.The samples could be stored at room temperature for at least 14 days.CONCLUSION: This method has high desorption efficiency and sensitivity with good precision and simple operation,which is suitable for simultaneous detection of 1,2-dichloropropane and 1,3-dichloropropane in the workplace air.