ABSTRACT
Objective:To observe the physiological effect of bi-level positive airway pressure (BiPAP) ventilation among stable chronic obstructive pulmonary disease (COPD) patients.Methods:This was a small sample size, exploratory, interventional study. A total of 10 outpatients with stable COPD were included from Department of Pulmonary and Critical Care Medicine of Zhujiang Hospital, Southern Medical University between January 2018 and December 2018. The BiPAP mode of noninvasive mechanical ventilation was adopted. The inspiratory positive airway pressure was gradually increased from 10 cmH 2O (1 cmH 2O=0.098 kPa) to 24 cmH 2O, and each time by 2 cmH 2O. The expiratory positive airway pressure remained unchanged at 4 cmH 2O. Baseline and test data were collected before and during the ventilation for comparison, including total respiratory cycle time (T tot), inspiratory time (T i), inspiratory time (T e), inspiratory tidal volume (V Ti); mouth pressure (P mo), esophageal pressure (P eso), transdiaphragmatic pressure (P di), esophageal pressure time product (PTP es), diaphragm pressure time product (PTP di), root mean square of electromyography of diaphragm (RMS), V e/RMS, inspiratory capacity (IC), the change in end-expiratory lung volume (ΔEELV) and dynamic PEEPi (PEEPi dyn). Results:All the 10 patients completed the trial. Compared to calm breathing, V Ti, V e, P mo, IC, ΔEELV score and V e/RMS increased significantly with increasing pressure levels (all P<0.05); T e only increased significantly at 20-22 cmH 2O pressure levels compared to calm breathing ( P<0.05). P di, PTP es, PTP di, RMS and RMS/RMS max decreased significantly with increasing levels (all P<0.05). PTP es and PTP di converged to 0 and no longer showed significant changes after the 18 cmH 2O pressure level. RMS and RMS/RMS max flattened out at pressure level greater than 16 cmH 2O. T i/T tot only significantly decreased at the 20 cmH 2O pressure level compared to calm breathing. PEEPi dyn showed a tendency to decrease and then increase with increasing pressure levels. Conclusion:BiPAP ventilation, at appropriate pressure levels, significantly relieves pulmonary ventilation disorders and reduces the load of respiratory muscle in patients with stable COPD.
ABSTRACT
【Objective】 To compare the clinical efficacy and sagittal parameters of oblique lateral interbody fusion (OLIF) combined with posterior percutaneous internal fixation and percutaneous transforaminal endoscope-assisted posterior lumbar interbody fusion (PT-Endo-TLIF) in treating degenerative lumbar spondylolisthesis. 【Methods】 A retrospective analysis was made on 43 patients with Meyerding Ⅰ and Ⅱ° degenerative lumbar spondylolisthesis treated in our hospital from September 2017 to January 2020. Among them 23 cases were treated by OLIF, and the other 20 cases were treated by PT-Endo-TLIF. We observed and recorded the operation time, average length of hospital stay, and intraoperative blood loss, and postoperative complications of the patients. The patients were followed up 3 day, 6 and 12 months after the operation. The lumbar sagittal parameters of the two groups were compared by X-ray, CT and MRI examinations. The patients’ lower back pain was recorded for visual analogue scale (VAS), and Oswestry disability index (ODI) was used to evaluate the clinical efficacy. 【Results】 Both groups of patients successfully completed the operation and follow-up, with the average follow-up time of 12 months. The average amount of intraoperative blood loss and operation time were significantly lower in OLIF group than in PT-Endo-TLIF group (P<0.05). Intervertebral height increased significantly in the two groups after operation compared with pre-operation (P<0.05). Compared with pre-operation, lumbar lordosis angle, lower lumbar lordosis angle and lumbar lordosis distribution index increased in both groups (P<0.05), with no significant difference between them (P>0.05). The inclination angle of L4 vertebral body and the distance between L1 vertical line and S1 in both groups were decreased compared with those before surgery (P<0.05), but there was no significant difference between the two groups (P>0.05). The inclination angle of L5 vertebral body in the two groups was increased compared with that before surgery (P<0.05), but there was no statistical significance between both groups (P>0.05). 【Conclusion】 OLIF surgical technique has the comparative advantages of definite curative effect, less trauma, fewer surgical complications, shorter operation time, less bleeding, and good recovery of the height of intervertebral space, which is suitable for its application among clinicians.
ABSTRACT
BACKGROUND:Spine minimaly invasive technique through foraminal mirror is the method to treat lumbar disc herniation with minimal wound. This technique can be conducted under local anesthesia, and does not need to resect the smal joint or destroy the vertebral plate, and has smal damage to the spine. OBJECTIVE: To explore the short-period effects of transforaminal endoscopic spine system for adjacent-segment degenerative changes-caused low back pain after lumbar fixation and fusion. METHODS:A total of 31 patients with degenerative changes after posterior lumbar bone graft fusion fixation, who required secondary surgery, were enroled in this study, including 23 males and 8 females, at the age of 45-81 years old. The postoperative time was 1.1-5.7 years. There were 3 cases of L3-4 single segment, 15 cases of L4-5 single segment, 8 cases of L5S1 single segment, and 5 cases of multi-segment. These patients were treated with transforaminal endoscopic spine system, and folowed up for 6 months. Visual Analogue Scale score and lumbar function Japanese Orthopedic Association score were observed. RESULTS AND CONCLUSION: Lumbar and leg pain symptoms were relieved noticeably during the operation. The patient could walk immediately after the surgery, and the postoperative recovery was quite satisfactory. Visual Analogue Scale score was lower immediately, 1, 3 and 6 months after treatment compared with pre-treatment. Lumbar function Japanese Orthopedic Association score was higher immediately, 1, 3 and 6 months after treatment compared with pre-treatment. Results verify that transforaminal endoscopic spine system for degenerative changes after posterior lumbar bone graft fusion fixation has some advantages such as high safety, short operation time, less hemorrhage, less complications, rapid restoration and easily accepted by patients.
ABSTRACT
Objective To analyze the clinical results and early complications of corpectomy and reconstruction with titanium mesh cage implantation and pedicle screw fixation via a single posterior approach for severe thoracic and lumbar fractures.Methods Forty-four patients treated by reconstruction with titanium mesh cage implantation and pedicle screw fixation via a single posterior were studied retrospectively.There were 35 males and 9 females,with an average age of 37.3 years(range,19-66 years).The injury segments include 1 case at T11,5 cases at T12,20 cases at L1,11 cases at L2,5 cases at L3 and 2 cases at L4.According to AO classification,there were 24 cases of A3,17 cases of B1 and B2,and 3 cases of C1.According to ASIA,there were 10 cases of grade A,17 cases of grade B,10 cases of grade C and 7 cases of grade D.The neurologic function and effectiveness of correction of preoperative,immediate postoperative and 2years follow-up were compared,and the clinical outcome and early complications were analyzed.Results The follow-up time was 24 to 58 months,mean 38.9 months.At the time of 2 years postoperation,43 cases of incomplete neurologic deficit had improved 1 or 2 ASIA grades except 1 case of grade A.The results of decompression and reduction were satisfactory from the postoperative radiographic examinations.The correction maintained well and the implant loosening was not seen in 43 cases(97.7%)at the last follow-up.The com plications include:excessive blood loss(>1500 ml)in 9 cases,transient nerve root injury in 4,cerebrospinal fluid leakage in 3,instrumentation failure in 1,mesh cage malposition in 3,iatrogenic leaving of free bone granula into the canal in 2,and superficial infection in 1.Conclusion This technique is effective for decompression and fusion,less invasive than combined anteroposterior procedure,and may be another good alternative for the treatment of severe thoracic and lumbar fractures.The early complications are not rare,but most of them are not serious and are relative to techniques.
ABSTRACT
Objective: To explore and evaluate the biomechanic relationships between different depth of pedicle screw penetration with the sagittal plane reconstruction in thoracolumbar fracture. Methods:Six fresh cadaveric specimens of lumbar spine from L_1 to L_3 were used to make the model of thoracolumbar fracture. The system of universal spine system( USS )pedicle screw was adopted with the 6 mm diameter of screw. Each of two Schanz screws was implanted into the pedicles of L_1 and L_3 A canulated screw was fixed into the former of vertebral body in L_1 and L_3, and the distance of the two canulated screws was taken as the normal height. The axial loads were given while the pedicle screws were implanted at the depth of D1, D2 and D3, and the distance of the two canulated screw was measured as well as the distance was reduced to the normal height by axial load. The index measured included of the depth of pedicle screw penetration, the height of fractured vertebral body and afterload. Results: Along with the increasing of afterload, the height of injured vertebral body was increased accordingly, but the extent was different at three depth of pedicle screw penetration (D1, D2, and D3). While the injured vertebral body was reduced totally (reduced distance 0.00 mm), there was (2 630±13) g of afterload needed in Dl depth, and (2 339±61) g and(2 221± 164) g of afterload in D2 and D3 depth respectively. There was significant difference in distance between D1, D2 and D3 (P 0.05). Conclusion: There is a relationship in the depth of pedicle screw penetration, the capacity of reduction and sagittal plane reconstruction. The depth of pedicle screw had a significant effect on the capacity of reduction for the injured vertebral body, which would be the best option in biomechanics when the pedicle screw was implanted more than 1/2 pedicle or all of it.