Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Article in English | WPRIM | ID: wpr-928604

ABSTRACT

OBJECTIVES@#To study the association between paroxysmal nocturnal hemoglobinuria (PNH) clone and immunosuppressive therapy (IST) in children with severe aplastic anemia (SAA).@*METHODS@#A retrospective analysis was performed on the medical data of 151 children with SAA who were admitted and received IST from January 2012 to May 2020. According to the status of PNH clone, these children were divided into a negative PNH clone group (n=135) and a positive PNH clone group (n=16). Propensity score matching was used to balance the confounding factors, and the impact of PNH clone on the therapeutic effect of IST was analyzed.@*RESULTS@#The children with positive PNH clone accounted for 10.6% (16/151), and the median granulocyte clone size was 1.8%. The children with positive PNH clone had an older age and a higher reticulocyte count at diagnosis (P<0.05). After propensity score matching, there were no significant differences in baseline features between the negative PNH clone and positive PNH clone groups (P>0.05). The positive PNH clone group had a significantly lower overall response rate than the negative PNH clone group at 6, 12, and 24 months after IST (P<0.05). The evolution of PNH clone was heterogeneous after IST, and the children with PNH clone showed an increase in the 3-year cumulative incidence rate of aplastic anemia-PNH syndrome (P<0.05).@*CONCLUSIONS@#SAA children with positive PNH clone at diagnosis tend to have poor response to IST and are more likely to develop aplastic anemia-PNH syndrome.


Subject(s)
Anemia, Aplastic/drug therapy , Child , Clone Cells , Hemoglobinuria, Paroxysmal/etiology , Humans , Immunosuppression Therapy , Retrospective Studies
2.
Article in Chinese | WPRIM | ID: wpr-828721

ABSTRACT

OBJECTIVE@#To compare the efficacy of the CAMS-2005 and CAMS-2009 regimens in treating children with non-core binding factor acute myeloid leukemia (non-CBF AML) and to study the prognosis factors.@*METHODS@#A total of 161 children who were initially diagnosed with non-CBF AML from April 2005 to December 2015 were enrolled as study subjects, and were divided into a CAMS-2005 regimen group (n=52) and a CAMS-2009 regimen group (n=109) according to the chemotherapy regimen provided. The efficacy was retrospectively compared between the two groups.@*RESULTS@#The complete remission (CR) rate at the first course of treatment was higher in the CAMS-2009 regimen group than that in the CMAS-2005 regimen group (63.3% vs 46.2%; P0.05). Children who achieved CR at the first course of treatment had significantly higher OS and event-free survival rates than those who did not achieved CR (P<0.01).@*CONCLUSIONS@#The CAMS-2009 regimen is superior to the CAMS-2005 regimen in improving the CR rate in children with non-CBF AML after induction treatment. Whether CR is achieved at the first course of treatment can affect the OS rate of children with non-CBF AML.


Subject(s)
Antineoplastic Combined Chemotherapy Protocols , Child , Humans , Leukemia, Myeloid, Acute , Prognosis , Remission Induction , Retrospective Studies
3.
Article in English | WPRIM | ID: wpr-690598

ABSTRACT

<p><b>OBJECTIVE</b>In previous studies, we immunized mice with Ebola recombinant protein vaccine and gene vector vaccine. Both stimulated high levels of humoral immunity. In this work, we constructed a pseudovirus containing Ebola membrane proteins to verify whether the two immunization strategies can induce neutralizing antibodies in mice.</p><p><b>METHODS</b>A pseudovirus containing an Ebola virus membrane protein based on the HIV-1 viral gene sequence was constructed and evaluated using a known neutralizing antibody. The titer of the neutralizing antibody in the sera of mice immunized with the recombinant protein and the gene vector vaccine was examined using a neutralization test.</p><p><b>RESULTS</b>Ebola pseudovirus was successfully prepared and applied for neutralizing antibody detection. Immunological experiments showed that recombinant protein GP-Fc and gene vaccine pVR-modGP-Fc had good immunogenicity. The titer of the bound antibody in the serum after 8 weeks of immunization in mice was more than 1:105, and the recombinant protein induced greater humoral immunity. The results of the neutralization test based on the Ebola pseudovirus system demonstrated that both vaccines induced production of protective antibodies, while the gene vaccine induced a higher titer of neutralizing antibodies.</p><p><b>CONCLUSION</b>An Ebola pseudovirus detection system was successfully established and used to evaluate two Ebola vaccines. Both produced good immunogenicity. The findings lay the foundation for the development of new Ebola vaccines and screening for neutralizing monoclonal antibodies.</p>

4.
Article in English | WPRIM | ID: wpr-311395

ABSTRACT

<p><b>OBJECTIVE</b>To develop a rapid, highly sensitive, and quantitative method for the detection of NT-proBNP levels based on a near-infrared point-of-care diagnostic (POCT) device with wide scope.</p><p><b>METHODS</b>The lateral flow assay (LFA) strip of NT-proBNP was first prepared to achieve rapid detection. Then, the antibody pairs for NT-proBNP were screened and labeled with the near-infrared fluorescent dye Dylight-800. The capture antibody was fixed on a nitrocellulose membrane by a scribing device. Serial dilutions of serum samples were prepared using NT-proBNP-free serum series. The prepared test strips, combined with a near-infrared POCT device, were validated by known concentrations of clinical samples. The POCT device gave the output of the ratio of the intensity of the fluorescence signal of the detection line to that of the quality control line. The relationship between the ratio value and the concentration of the specimen was plotted as a work curve. The results of 62 clinical specimens obtained from our method were compared in parallel with those obtained from the Roche E411 kit.</p><p><b>RESULTS</b>Based on the log-log plot, the new method demonstrated that there was a good linear relationship between the ratio value and NT-proBNP concentrations ranging from 20 pg/mL to 10 ng/mL. The results of the 62 clinical specimens measured by our method showed a good linear correlation with those measured by the Roche E411 kit.</p><p><b>CONCLUSION</b>The new LFA detection method of NT-proBNP levels based on the near-infrared POCT device was rapid and highly sensitive with wide scope and was thus suitable for rapid and early clinical diagnosis of cardiac impairment.</p>


Subject(s)
Antibodies , Biomarkers , Heart Diseases , Diagnosis , Humans , Immunoassay , Methods , Infrared Rays , Natriuretic Peptide, Brain , Blood , Peptide Fragments , Blood , Point-of-Care Testing , Reagent Strips , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL