Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Biotechnology ; (12): 2839-2860, 2023.
Article in Chinese | WPRIM | ID: wpr-981236

ABSTRACT

The present study aims to explore the genetic diversity of germplasm resources of Chrysanthemum×morifolium (hereinafter, C.×morifolium) at the molecular level and to establish a fingerprint database of C.×morifolium varieties. We employed 12 pairs of primers with high levels of polymorphism, clear bands, and high degrees of reproducibility to analyze the SSR molecular markers and genetic diversity of 91 C.×morifolium materials and 14 chrysanthemum- related materials. With regard to constructing the fingerprints of the tested materials, we chose 9 pairs of core primers. The findings revealed that 12 primer pairs detected 104 alleles in 105 samples, ranging from 2 to 26. The average number of observed alleles (Na) per site was 9.25. The average number of effective alleles (Ne) per site was 2.745 6, with its range being 1.276 0 to 4.742 5. Shannon genetic diversity index (I) values ranged between 0.513 3 and 2.239 9 (M=1.209 0). Nei's gene diversity index (H) ranged between 0.216 3 and 0.789 1 (M=0.578 0). The observed heterozygosity (Ho) ranged between 0.223 3 and 0.895 2 (M=0.557 5). The expected heterozygosity (He) ranged between 0.217 4 and 0.793 3 (M=0.580 8). The polymorphism information content (PIC) ranged between 0.211 5 and 0.774 0 (M=0.532 9). The genetic similarity (GS) ranged between 0.228 5 and 1.000 0 (M=0.608 3). Cluster analysis revealed that when the genetic distance (GD) equals to 0.30, the tested materials can be classified into 2 groups. When the GD equals to 0.27, the first group can be divided into 6 subgroups; accordingly, 105 tested materials can be divided into 7 subgroups. The cophenetic correlation test was carried out based on the cluster analysis, and the corresponding results showed that the cluster map correlated with the genetic similarity coefficient (r=0.952 73). According to the results of Structure population analysis, we obtained the optimal population number, with the true number of populations (K) being 3 and the population being divided concerning Q≥0.5. Three subgroups, i.e., Q1, Q2 and Q3, included 34, 33 and 28 germplasms, respectively, and the remaining 10 germplasms were identified as the mixed population. During the experiment, 9 pairs of core primers were screened among the total of 12 for a complete differentiation regarding 105 tested materials, and the fingerprints of 91 C.×morifolium materials and 14 chrysanthemum-related materials were further constructed. Overall, there were significant genetic differences and rich genetic diversity among C.×morifolium materials, which would shed light on the garden application and variety selection fields of C.×morifolium. The fingerprint database of 105 C.×morifolium varieties and chrysanthemum-related species may provide technical support for future research regarding the identification and screening system of C.×morifolium varieties.


Subject(s)
Genetic Variation , Chrysanthemum/genetics , Reproducibility of Results , Microsatellite Repeats/genetics , Polymorphism, Genetic , Biomarkers , Phylogeny
2.
Journal of Chinese Physician ; (12): 1482-1484, 2015.
Article in Chinese | WPRIM | ID: wpr-482783

ABSTRACT

Objective To evaluate the clinical application of a novel hepatitis B virus YMDD mutation DNA diagnostic kit (magnetic beads method kit).Methods A total of 324 HBV clinical serum samples was tested with the magnetic beads method kit and another kind of fluorescence diagnostic kit (boiling method).Accuracy, specificity, and sensitivity were compared.Results The consistency of positive detection rate of two kits was 100% (95% CI : 98.0% ~ 100%), negative consistency was 97.12% (95% CI : 92.8% ~99.2%) and the total consistency was 98.76% (95% CI : 96.9% ~99.7%).Four cases of discrepant samples were confirmed by sequencing, and statistical analysis performed by Kappa test (Kappa =0.975) shows good consistency between the two methods.Conclusions The magnetic beads method kit has good consistency compared to the regular boiling method kit, and the polymerase chain reaction (PCR) detection system contains an internal positive control (internal control) to avoid a false negative resuit, which is more suitable for clinical diagnosis.

SELECTION OF CITATIONS
SEARCH DETAIL