Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 130
Filter
1.
Article in Chinese | WPRIM | ID: wpr-1026862

ABSTRACT

This article mainly elaborated the acupuncture and moxibustion treatment scheme of"eighteen needles for reproduction"based on Professor You Zhaoling's reproductive axis theory of"heart-kidney-Chong Ren-uterus".The"eighteen needles for reproduction"aims to regulate the disordered reproductive axis in gynecological reproductive diseases.It selects the acupoints on the main viscera and meridians of the reproductive axis as the main acupoints,and the acupoints regulating the qi and blood of the related viscera as the matching acupoints.Through specific manipulation,it can regulate the qi and blood,dredge the meridians,and treat the viscera,so as to nourish the essence and help pregnancy,and provide ideas and reference for the treatment of gynecological reproductive diseases with acupuncture and moxibustion.

2.
Article in Chinese | WPRIM | ID: wpr-1029895

ABSTRACT

Objective:To assess the applicability of fully automatic pipeline automated testing for internal quality control (automated quality control).Methods:Stability, assay efficiency and implementation costs of 18 biochemical tests, 5 immunoturbidimetric tests and 11 chemical illuminescent tests in the Department of Laboratory Medicine of Peking Union Hospital from January 2019 to July 2022 were evaluated using automated quality control implementation methods. The detailed method is as follows: quality control materials for biochemical, immunoturbidimetric and chemiluminescent tests were stored in the refrigerator in the pipeline which was controlled by the intermediate software, and were automatically retrieved and tested as pre-set followed by documenting and storing. The quality control setup for the biochemical tests included refreshing quality control materials daily and weekly,both of which were paralleled for 3 months. The on-line storage stability of quality control materials in the pipeline was evaluated by comparing the coefficients of variation ( CV) of the quality control results between the two patterns. Effect of automated quality control application was evaluated using 6 indicators, including the results′ variation of automatically performed and manually performed quality controls, the out-of-controlled rate, the consumption of quality control materials, the change of staff workload, the impact on the testing time of the first sample, and the failure rate of automated quality control. Results:(1) Storage stability of quality control materials in the pipeline: under the pattern of weekly refresh of the biochemical quality control materials, except for total carbon dioxide (TCO 2) (the CVs of low and high level quality control were respectively 20.24% and 21.82%) and sodium (the CV of low level quality control was 1.51%) that were greater than the allowable variation set by the laboratory, the CVs of the rest tests meet the lab requirements on the allowable variations. (2) The results′ variation of quality control in automatically performed and manually performed control patterns: in the patterns of daily refresh of biochemical quality control materials and weekly refresh of immunoturbidimetric and chemiluminescent quality control materials, the CVs of both low and high levels of quality control were lower in the automatically performed control pattern than that in manually performed pattern for 8 chemiluminescent items of dehydroepiandrosterone sulfate, estradiol, follicle stimulating hormone, luteinizing hormone, serum ferritin, serum folic acid, vitamin B12 and testosterone, 3 immunologic items of complement 3, C reactive protein and immunoglobulin G, and 10 biochemical items of alkaline phosphatase, glucose, calcium, chloride, potassium, lactate dehydrogenase, sodium, urea, low density lipoprotein cholesterol, and adenosine deaminase. The out-of-control rates of biochemistry, immunoturbidimetric and chemiluminescence tests in both quality control patterns conformed with the clinical routine work requirements. (3) Comparison of quality control materials′ consumption: compared with manually performed quality control, weekly consumption of automatically performed chemiluminescent quality control materials decreased 37.5% (from 8 ml to 5 ml); weekly consumption of automatically performed immunoturbidimetric quality control materials decreased 33.3% (from 3 ml to 2 ml). (4)Comparison of staff workload and first sample testing time: compared with manually performed quality control, automatical quality control reduced manual work by about 156 steps per week, and the daily initial testing time was earlier by 15 min on average. The failure rate was 54.5% (37/64) during the early-stage application of the automated quality control which dropped to 10.2% (13/128) in the late-stage. Conclusion:The results of automated quality control detected in the pipeline system meet the quality indicators′ requirements of the laboratory, and the application of automated quality control can improve the quality control, save costs, reduce workload, and improve work efficiency.

3.
Article in Chinese | WPRIM | ID: wpr-1029915

ABSTRACT

Clinical application of mass spectrometry technology has attracted the attention of clinical laboratory experts due to its high sensitivity, high specificity, and capacities of simultaneous detection of multiple compounds. In recent years, mass spectrometry technology has made significant achievements in the fields of identification of pathogenic microorganism, detection of trace elements and heavy metals, small molecule hormones, vitamins, amino acids, peptides and proteins, as well as therapeutic drug monitoring (TDM) and poisoning drugs screening. In order to further clarify the opportunities and challenges brought by this complex mass spectrometry technology in the field of clinical laboratory, the Chinese Journal of Laboratory Medicine invited experts and scholars of laboratory medicine to share their experience and opinions on related items focusing on the positioning of mass spectrometry technology in the clinical laboratory, the development and improvement of the clinical laboratory by mass spectrometry technology, the challenges of interpreting mass spectrometry test results, the challenges of operating and managing clinical mass spectrometry laboratories, and ways of improving the application of clinical mass spectrometry laboratories with this technology. Agreement was achieved in that the introduction of mass spectrometry technology into the clinical laboratory could bring new directions and opportunities for clinical testing and research, and also is associated with a series of challenges such as the difficulty of sample pretreatment, the high cost and complexity of mass spectrometry technology, the complexity of data processing and interpretation, the lack of standards and norms, and the issue of determining the price of mass spectrometry examinations.

4.
Article in Chinese | WPRIM | ID: wpr-1029930

ABSTRACT

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology has the characteristics of high specificity and high throughput, making it rapidly applied and developed in the field of clinical testing. Its application in the monitoring of therapeutic drugs can effectively improve the quantitative accuracy and sensitivity, and formulate a personalized and optimal dosing plan for patients. However, this technology still faces some challenges, and automation, quality control, and quantitative traceability will be the future development direction.

5.
Yao Xue Xue Bao ; (12): 253-264, 2024.
Article in Chinese | WPRIM | ID: wpr-1005443

ABSTRACT

Cellulose synthase (CesA), one of the key enzymes in the biosynthesis of cellulose in plants, plays an important role in plant growth and plant resistance. In this study, a total of 21 AsCesA genes from Aquilaria sinensis were systematically identified and the physico-chemical characteristics were analyzed based on genome database and bioinformatical methods. The phylogenetic tree was constructed and the gene location on chromosome, cis-acting elements in the 2 000 basepairs upstream regulatory regions and conservative motifs were analyzed. The AsCesA proteins were mainly located on the plasma membrane. The number of amino acids of the proteins ranged from 390 to 1 261. The isoelectric point distributed from 5.67 to 8.86. All of the 21 AsCesA proteins possessed the transmembrane domains, the number of which was from 6 to 8. The genes were classified into 3 groups according to the phylogenetic relationship. Obvious differences were observed in motif composition in genes from different groups. However, motif2, motif6, motif7 and motif10 were observed in all of AsCesA proteins. Analysis of cis-acting elements indicated that AsCesA genes family has cis-acting elements related to plant hormones, abiotic stresses, and biological processes. Seven AsCesA genes with differential expression were selected according to the calli transcriptome data induced by NaCl at different times and their expression levels under different abiotic stresses were analyzed by quantitative real-time PCR. The results indicated that salt, low temperature, drought, and heavy metal stresses could affect the expression level of AsCesA genes, and the abundance of AsCesA1, AsCesA3 and AsCesA20 showed a significant change, implying their potential important roles to the abiotic stresses. The accumulation pattern of cellulose content under different abiotic stresses was similar to the expression trend of AsCesA genes. Our results provide valuable insights into the role of cellulose synthase in A.sinensis in plant defense.

6.
Article in English | WPRIM | ID: wpr-1042003

ABSTRACT

Background@#Twenty-four-hour urinary free cortisol (UFC) measurement is the initial diagnostic test for Cushing’s syndrome (CS). We compared UFC determination by both direct and extraction immunoassays using Abbott Architect, Siemens Atellica Solution, and Beckman DxI800 with liquid chromatography-tandem mass spectrometry (LC-MS/MS). In addition, we evaluated the value of 24-hr UFC measured by six methods for diagnosing CS. @*Methods@#Residual 24-hr urine samples of 94 CS and 246 non-CS patients were collected.A laboratory-developed LC-MS/MS method was used as reference. UFC was measured by direct assays (D) using Abbott, Siemens, and Beckman platforms and by extraction assays (E) using Siemens and Beckman platforms. Method was compared using Passing–Bablok regression and Bland–Altman plot analyses. Cut-off values for the six assays and corresponding sensitivities and specificities were calculated by ROC analysis. @*Results@#Abbott-D, Beckman-E, Siemens-E, and Siemens-D showed strong correlations with LC-MS/MS (Spearman coefficient r = 0.965, 0.922, 0.922, and 0.897, respectively), while Beckman-D showed weaker correlation (r = 0.755). All immunoassays showed proportionally positive bias. The areas under the curve were 0.975 for Abbott-D, 0.972 for LCMS/MS, 0.966 for Siemens-E, 0.948 for Siemens-D, 0.955 for Beckman-E, and 0.877 for Beckman-D. The cut-off values varied significantly (154.8–1,321.5 nmol/24 hrs). Assay sensitivity and specificity ranged from 76.1% to 93.2% and from 93.0% to 97.1%, respectively. @*Conclusions@#Commercially available immunoassays for measuring UFC show different levels of analytical consistency compared to LC-MS/MS. Abbott-D, Siemens-E, and Beckman-E have high diagnostic accuracy for CS.

7.
Basic & Clinical Medicine ; (12): 1841-1846, 2023.
Article in Chinese | WPRIM | ID: wpr-1018550

ABSTRACT

Objective To investigate and analyze the level of homocysteine(Hcy)in Tibet and to analyze the differences of Hcy level in different altitude regions,genders and ages,and thus to provide the prevalence profile of hyperhomocysteine and the differences in relevant tests between HHcy(hyperhomocysteinemia)and non-HHcy pop-ulations.Methods Totally 1 615(male n=585)subjects were selected from Ngari,Lhasa,Shigatse and Nyingchi plat-eau areas of Tibet by stratified cluster sampling.Serum Hcy level was analyzed and the difference of Hcy level in pop-ulations located at different altitude plateau areas,gender groups were found.The prevalence of hyperhomocysteine and related test were analyzed.Kruskal Wallis test was used to compare Hcy levels in different altitudes,genders and age groups,and Pearson Chi-square test was used to compare HHcy prevalence.Variance analysis was used for the differences of different test indicators between non-HHcy and HHcy populations.Results The level of Hcy in differ-ent regions and different genders were statistically significant,which was higher in males than that in females,and higher in Lhasa and Shigatse than in Nyingchi and Ngari.There was difference in serum HHcy prevalence among dif-ferent genders,regions and age groups.Males showed a higher level than females,people from Lhasa and Shigatse showed a higher level than those from Nyingchi and Ngari.Conclusions The incidence of hyperhomocysteinemia in Tibet is statistically significant in different areas,different genders and different age groups.So this study provides a scientific basis for the rational use of Hcy as an indicator in clinical practice of prevention and treatment of related diseases in plateau areas.

8.
Article in Chinese | WPRIM | ID: wpr-1029853

ABSTRACT

Objective:To compare the differences of reference intervals (RI) established by two types of indirect methods for 34 biochemical analytes, and to explore the possible factors that affect the consistency of the two methods.Methods:This was a retrospective study. Based on data of albumin (Alb), alkaline phosphatase (ALP), alanine aminotransferase (ALT), apolipoprotein A1(ApoA1), ApolipoproteinB (ApoB), aspartate aminotransferase (AST), calcium (Ca), cholinesterase (ChE), chloride (Cl), creatinine (Cr), high-sensitivity C-reactive protein (hsCRP), Cystatin (CysC), direct bilirubin (DBil), free fatty acid (FFA), glycated albumin(GA), gamma-glutamyltransferase (GGT), glucose (Glu), high density lipoprotein cholesterol (HDL-C), potassium (K), lactate dehydrogenase (LD), low density lipoprotein cholesterol (LDL-C), lipoprotein a [Lp (a)], sodium (Na), phosphorus (P), prealbumin (PA), superoxide dismutase (SOD), total bile acid (TBA), total bilirubin (TBil), total cholesterol (TC), total carbon dioxide (TCO 2), triglyceride (TG), total protein (TP), uric acid (UA) and urea (UR) of individuals who underwent physical examination at Peking Union Medical College Hospital from January 1, 2018 to December 31, 2019, Box-Cox algorithm was used to improve the data distribution and Tukey method was used to identify outliers. Variance component model was established, and standard deviation ratio (SDR) was calculated to determine whether the RIs of 34 biochemical analytes should be established according to age or sex The non-parametric method and kosmic algorithm were used to establish the RIs and 90% confidence intervals (CIs) of 34 biochemical analytes, and the coincidence of the 90% CIs of the reference limits for two methods was compared. Results:The skewness coefficients of ALP(male, female18-59), ALT, AST, hsCRP, DBil, GGT, Lp (a), TBA, TBil, TG, Glu, HDL-C(male) and CysC, GA, UR in the elderly group deviated from 0, and their kurtosis coefficients also deviated from 3. For these biochemical analytes, the point estimates of the RIs established by the two methods differed greatly and the 90% CIs did not overlap. The analytes with good normality were Alb, ApoA1, ApoB, Ca, ChE, Cl, Cr(E), CysC(18-59), FFA, GA(18-59), HDL-C(female), K, LDL-C, Na, P, PA, SOD, TC, TCO 2, TP and UR. The consistency is good. Except for Ca, 90% CIs of reference limits for some analyte between the two methods coincide with each other. Conclusions:The consistency of different indirect methods is affected by the normality of data.

9.
Article in Chinese | WPRIM | ID: wpr-1029867

ABSTRACT

Objective:To explore the application of PDCA (plan, do, check, act) cycle theory in the teaching of eight-year clinical medical students for the course of Laboratory Diagnostics.Methods:From September 2021 to November 2022, the students majoring in clinical medicine of eight-year system who were studying the course of Laboratory Diagnostics at Peking Union Medical College were selected as the research objects. The teaching reform of the course of Laboratory Diagnostics was carried out according to the four stages of PDCA cycle theory, and the teaching effect was evaluated by the final examination results and questionnaire survey scores of the students.Results:The score of theoretical examination of eight-year students in 2018 was (86.7±4.68) points, which was higher than that of students in 2017 [(83.3±3.89) points], and the difference was statistically significant ( P<0.05). The questionnaire survey results of the two groups of students showed that the rating of experimental course was higher than that of theoretical course ( P<0.05). After the teaching reform based on PDCA cycle theory, the questionnaire survey scores of theoretical course [(3.83±0.25) points vs (2.94±0.28) points] and experimental course [(4.13±0.09) points vs (3.32±0.12) points] in students of 2018 were higher than those of 2017 (all P<0.001). Conclusion:PDCA cycle theory provides new methods and ideas for teaching management, which helps to improve the performance of clinical medical students of eight-year system and their recognition of the course.

10.
Yao Xue Xue Bao ; (12): 1079-1089, 2023.
Article in Chinese | WPRIM | ID: wpr-978748

ABSTRACT

Dihydroflavonol 4-reductase (DFR) plays an essential role in the biosynthesis of anthocyanin and regulation of plant flower color. Based on the transcriptome data of Cistanche tubulosa (Schenk) Wight, a full-length cDNA sequence of CtDFR gene was cloned by reverse transcription-polymerase chain reaction (RT-PCR). CtDFR contains an open reading frame (ORF) of 1 263 bp which encodes 420 amino acids with a predicted molecular weight of 47.5 kDa. The sequence analysis showed that CtDFR contains a nicotinamide adenine dinucleotide phosphate (NADPH) binding domain and a specific substrate binding domain. The expression analysis indicated that CtDFR was highly expressed in red and purple flowers, and the relative expression levels were 4.04 and 19.37 times higher than those of white flowers, respectively. The recombinant CtDFR protein was expressed in E.coli BL21 (DE3) using vector pET-28a-CtDFR and was purified. In vitro enzyme activity analysis, CtDFR could reduce three types of dihydroflavonols including dihydrokaempferol, dihydroquercetin, and dihydromyricetin to leucopelargonidin, leucocyanidin and leucodelphinidin. Subcellular localization analysis showed that CtDFR was mainly localized in the cytoplasm. These results demonstrate that CtDFR plays an important role in regulation of flower color in C. tubulosa and make a valuable contribution for the further investigation on the regulation mechanism of C. tubulosa (Schenk) Wight flower color.

11.
Article in Chinese | WPRIM | ID: wpr-993594

ABSTRACT

Objective:To explore the application potential of 18F-Asp-Glu-val-Asp (DEVD)-Cys(StBu)-PPG(CBT)-AmBF 3 ( 18F-1; PPG: propargyl-glycine; CBT: 2-cyanobenzothiazole; AmBF 3: ammoniomethyl-trifluoroborate) PET imaging in early monitoring of triple-negative breast cancer (TNBC) radiotherapy response. Methods:Ten MDA-MB-231 tumor bearing nude mice models were constructed and divided into radiotherapy group ( n=5) and non-radiotherapy group ( n=5) by random sampling method. The radiotherapy group was treated with single irradiation at a dose of 8 Gy. 18F-1 microPET imaging was performed in the radiotherapy and non-radiotherapy groups, and the tumor uptake and muscle uptake in 2 groups at different time points (2.5, 7.5, 12.5, 17.5, 22.5, 27.5, 32.5, 37.5, 42.5, 47.5, 52.5, 57.5 min after injection) were analyzed. The specific uptake of the probe in apoptotic cells was verified by radioautography, HE staining and immunofluorescent staining. Repeated measures analysis of variance and one-way analysis of variance were used to analyze data. Results:18F-1 microPET imaging showed that there was significant difference between tumor uptake and muscle uptake in radiotherapy group ( F=20.27, P=0.011). The uptake of radiotherapy group was the highest at 7.5 min after injection ((4.64±0.35) percentage activity of injection dose per gram of tissue(%ID/g)). There was no significant difference between tumor uptake and muscle uptake in the non-radiotherapy group ( F=1.81, P=0.215). The tumor/muscle (T/M) ratio of radiotherapy group was higher than that of non-radiotherapy group ( F=31.95, P=0.005), with the highest at 47.5 min after injection (2.49±0.46). Radioautography showed that the tumor radioactivity in radiotherapy group was higher than that of muscle in radiotherapy group, and was also higher than tumor and muscle radioactivies in non-radiotherapy group ( F=116.79, P<0.001). HE staining and immunofluorescent staining verified that 18F-1 could specifically detect the activity of caspase-3 activated in tumor cells after radiotherapy. Conclusion:18F-1 can specifically recognize the activated caspase-3 after TNBC radiotherapy, and monitor radiotherapy response at the molecular level by apoptosis PET imaging.

12.
Article in Chinese | WPRIM | ID: wpr-995796

ABSTRACT

Objective:To establish and validate an LC-MS/MS method for simultaneous determination of Aβ 1-42, Aβ 1-40, and Aβ 1-38 in cerebrospinal fluid. Additionally, the consistency between this method and three mainstream detection methods was evaluated.Methods:This study involved method establishment, validation, and consistency evaluation. The N15 labeled β-amyloid protein was used as the internal standard. Extraction was performed using Waters MCX 96-wells solid phase extraction plate, and the eluent was collected to QuanRecovery MaxPeak 700 μl plate. At the positive ion mode, the multi-reaction ion monitoring mode based on electric spray ionization is chosen for the determination of CSF Aβ 1-42, Aβ 1-40, and Aβ 1-38. Referring to the CLSI C62-A and EP-15A3 guidelines, the method is evaluated and verified, including quantitation of limit (LOQ), linearity, recovery, precision, and accuracy. In addition, a total of 57 clinical residual CSF samples were collected and the concentrations of Aβ 1-42 and Aβ 1-40 were determined based on manual INNOTEST ELISA assay and Lumipulse G and Roche Elecsys fully automated biochemical analyzers. The comparison analysis and deviation evaluation were conducted by passing-bablok and Bland Altman methods.Results:The analysis time of this method is 8 min, and the LOQ of Aβ 1-42, Aβ1-40 and Aβ1-38 is 0.1 ng/ml, 0.5 ng/ml, and 0.1 ng/ml, respectively, and the linear range can meet the needs of clinical detection. Respectively, the recovery is 86.2%-93.8%, 100.9%-103.9% and 103.3%-107.1%; the total imprecision is 4.7%-7.4%, 3.5%-4.6% and 5.2%-10.9%. The measured values of Aβ 1-42 certified reference materials are all within the allowable uncertainty requirements. Moreover, the carryover rate of three analytes was all≤0.11%. In addition, the correlations of Aβ 1-42 and Aβ1-40 in CSF between this LC-MS/MS method and the INNOTEST ELISA method, Lumipulse G and Roche Elecsys fully automated biochemical analyzers were all deemed good, with correlation coefficient (r) ranging from 0.920 to 0.970. However, the measured values between the four methods were remarkably different.Conclusion:We established and validated a robust method based on LC-MS/MS technology for simultaneous determination of Aβ 1-42, Aβ 1-40, and Aβ 1-38 in CSF. The method is accurate, simple, and suitable for clinical measurements. However, despite good correlations, there were substantial differences in the measurement results of Aβ 1-42 and Aβ 1-40 among different analytical platforms, indicating the need for further promotion of harmonization and standardization processes for AD classic biomarkers.

13.
Chinese Journal of Hematology ; (12): 321-327, 2023.
Article in Chinese | WPRIM | ID: wpr-984622

ABSTRACT

Objective: To analyze the clinicopathologic characteristics and prognosis of testicular diffuse large B-cell lymphoma (DLBCL) . Methods: A retrospective analysis was performed on 68 patients with testicular DLBCL admitted to Ruijin Hospital affiliated to Shanghai Jiao Tong University School of Medicine from October 2001 to April 2020. The gene mutation profile was evaluated by targeted sequencing (55 lymphoma-related genes) , and prognostic factors were analyzed. Results: A total of 68 patients were included, of whom 45 (66.2% ) had primary testicular DLBCL and 23 (33.8% ) had secondary testicular DLBCL. The proportion of secondary testicular DLBCL patients with Ann Arbor stage Ⅲ-Ⅳ (P<0.001) , elevated LDH (P<0.001) , ECOG score ≥ 2 points (P=0.005) , and IPI score 3-5 points (P<0.001) is higher than that of primary testicular DLBCL patients. Sixty-two (91% ) patients received rituximab in combination with cyclophosphamide, adriamycin, vincristine, and prednisone (R-CHOP) -based first-line regimen, whereas 54 cases (79% ) underwent orchiectomy prior to chemotherapy. Patients with secondary testicular DLBCL had a lower estimated 5-year progression-free survival (PFS) rate (16.5% vs 68.1% , P<0.001) and 5-year overall survival (OS) rate (63.4% vs 74.9% , P=0.008) than those with primary testicular DLBCL, and their complete remission rate (57% vs 91% , P=0.003) was also lower than that of primary testicular DLBCL. The ECOG scores of ≥2 (PFS: P=0.018; OS: P<0.001) , Ann Arbor stages Ⅲ-Ⅳ (PFS: P<0.001; OS: P=0.018) , increased LDH levels (PFS: P=0.015; OS: P=0.006) , and multiple extra-nodal involvements (PFS: P<0.001; OS: P=0.013) were poor prognostic factors in testicular DLBCL. Targeted sequencing data in 20 patients with testicular DLBCL showed that the mutation frequencies of ≥20% were PIM1 (12 cases, 60% ) , MYD88 (11 cases, 55% ) , CD79B (9 cases, 45% ) , CREBBP (5 cases, 25% ) , KMT2D (5 cases, 25% ) , ATM (4 cases, 20% ) , and BTG2 (4 cases, 20% ) . The frequency of mutations in KMT2D in patients with secondary testicular DLBCL was higher than that in patients with primary testicular DLBCL (66.7% vs 7.1% , P=0.014) and was associated with a lower 5-year PFS rate in patients with testicular DLBCL (P=0.019) . Conclusion: Patients with secondary testicular DLBCL had worse PFS and OS than those with primary testicular DLBCL. The ECOG scores of ≥2, Ann Arbor stages Ⅲ-Ⅳ, increased LDH levels, and multiple extra-nodal involvements were poor prognostic factors in testicular DLBCL. PIM1, MYD88, CD79B, CREBBP, KMT2D, ATM, and BTG2 were commonly mutated genes in testicular DLBCL, and the prognosis of patients with KMT2D mutations was poor.


Subject(s)
Male , Adult , Humans , Prognosis , Retrospective Studies , Myeloid Differentiation Factor 88 , China/epidemiology , Testicular Neoplasms/drug therapy , Cyclophosphamide , Rituximab/therapeutic use , Lymphoma, Large B-Cell, Diffuse/drug therapy , Prednisone/therapeutic use , Doxorubicin/therapeutic use , Vincristine/therapeutic use , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Immediate-Early Proteins/therapeutic use , Tumor Suppressor Proteins
14.
Article in Chinese | WPRIM | ID: wpr-934365

ABSTRACT

Objective:To evaluate the performance of magnetic beads extraction method (MGE) for the measurement of catecholamine metabolites by liquid chromatography tandem mass spectrometry.Methods:This is a methodological evaluation study. The linearity, limit of quantitation, recovery, precision, and matrix effect of catecholamine metabolites 3-methoxyepinephrine (MN), 3-methoxynorepinephrine (NMN) and 3-methoxytyramine (3-MT) extracted by MGE method were evaluated according to CLSI C62-A. Consensus of method development and validation of liquid chromatography-tandem mass spectrometry in clinical laboratories and other guidelines, 132 clinical residual plasma samples were collected and extracted by automated MGE and traditional solid phase extraction (SPE) method to compare the harmonization of the two extraction methods.Results:The linearity of MN, NMN and 3-MT extracted by automated MGE was>0.99, and the LOQ for MN, NMN and 3-MT were 0.033 5 nmol/L, 0.054 7 nmol/L and 0.011 0 nmol/L, respectively. The repeatability of MN, NMN and 3-MT were 1.3%-5.1%, 2.2%-5.6% and 1.7%-7.1%, respectively. The total imprecision in the laboratory were 1.5%-8.2%, 2.2%-7.7%, 2.1%-11.2%. Although the absolute recovery is low, the average relative recoveries of MN, NMN and 3-MT were 91.5%-108.5%, 92.0%-108.6%, and 89.3%-104.1%, respectively, and the percentage deviation from the expected concentration was within 15%. After isotope internal standard correction, the relative matrix effect is close to 100%, which can compensate for the potential matrix effect. The results of MGE and SPE of MN, NMN and 3-MT showeda good correlation (correlation coefficient r>0.99). The average relative deviations of MN, NMN and 3-MT were 0.2%, -1.4% and 1.0%, respectively. Conclusion:The automatic MGE method hasa good performance in extracting catecholamine metabolites, and is expected to be used in high-throughput analysis of samples in clinical in the future.

15.
Zhongguo zhenjiu ; (12): 741-746, 2022.
Article in Chinese | WPRIM | ID: wpr-939526

ABSTRACT

OBJECTIVE@#To observe the clinical effect of moxibustion combined with plucking technique at Jiquan (HT 1) for preventing peripherally inserted central catheter (PICC)-related venous thrombosis in the upper limbs of malignant tumor patients.@*METHODS@#A total of 80 malignant tumor patients undergoing PICC were randomized into an observation group and a control group, 40 cases in each one. In the control group, the routine care for PICC was exerted. In the observation group, besides the routine care, moxibustion combined with plucking technique at Jiquan (HT 1) was added. Mild moxibustion was exerted along the venous distribution of PICC (avoiding the entry site) for 10 to 15 min, and then, the circling moxibustion was applied to Quchi (LI 11), Xuehai (SP 10) and Tianfu (LU 3), 3 to 5 min at each acupoint. Finally, plucking technique was given at Jiquan (HT 1) for 5 to 10 min. This combined therapy was intervened since the 2nd day of PICC placement, once daily, 5 times a week, for 3 weeks totally. The incidence of the PICC-related venous thrombosis in the upper limbs was compared between the two groups on day 42 of placement. On day 2, 7, 14, 21, 28, 35 and 42 of PICC placement, the peak systolic velocity (PSV) and the end-diastolic velocity (EDV) of the subclavicular vein on the placement side were observed separately in the two groups.@*RESULTS@#The incidence of the PICC-related venous thrombosis in the upper limbs in the observation group was lower than that in the control group (2.5% [1/40] vs 17.5% [7/40], P<0.05). From day 7 to 35 of PICC placement, PSV of the subclavicular vein on the placement side was higher than that on the day 2 of PICC placement in the observation group (P<0.05). On day 28 and 42 of PICC placement, PSV of the subclavicular vein on the placement side was lower than that on the day 2 of PICC placement in the control group (P<0.05). In the observation group, EDV of the subclavicular vein on the placement side was higher than that on the day 2 of PICC placement from day 7 to 28 of PICC placement (P<0.05). In the control group, EDV of the subclavicular vein on the placement side from day 28 to 42 of PICC placement was lower than that on the day 2 of PICC placement (P<0.05). From day 7 to 42 of PICC placement, PSV and EDV of the subclavicular vein on the placement side in the observation group were all higher than those in the control group (P<0.01, P<0.05).@*CONCLUSION@#The combined treatment of moxibustion with plucking technique at Jiquan (HT 1) can effectively prevent PICC-related venous thrombosis in the upper limbs and improve venous blood flow velocity in malignant tumor patients.


Subject(s)
Humans , Catheterization, Central Venous/methods , Catheterization, Peripheral/adverse effects , Moxibustion/adverse effects , Neoplasms/complications , Upper Extremity , Venous Thrombosis/etiology
16.
Article in Chinese | WPRIM | ID: wpr-958631

ABSTRACT

Objective:By exploring a construction and improvement system for total lab automation in emergency lab, this work aims to improve the success rates of project implementation and the effective utilization of medical resources.Methods:Firstly, clarify the short board of current solution and determine the configuration of the TLA solution which include the number of pre-analytic, post-analytic modules and analyzers by workflow and data analysis which based on the data from 16th to 22nd September 2019. Secondly, define the basic principles and design the optional solutions. Thirdly, determine the final solution based on the simulation results. Fourthly, evaluate the effectiveness of the solution by comparing the turnaroud time (TAT) before and after implementation.Result:We upgrade the system to improve the automation level of the track by add 1 online centrifuge module and upgrade the capacity of online storage module from 9 000 samples to 15 000 samples, and increase the throughput of the clinical chemistry analyzers form 2 500 tests/h to 5 400 tests/h and immunoassay analyzers from 668 tests/h to 1 320 tests/h with no more space. The 95th percentile TAT (from sample check in to validation) have 33% reduction on the premise of 9% increase on the workload of clinical chemistry and immunoassay, and it is highly consistent with the results obtained by data simulation whose 95th percentile TAT is 67 min.Conclusion:Good uasge of workflow and data analysis in the stage of solution design can help to ensure that the result can meet the expectations of the clinicians and effective utilization of medical resources.

17.
Article in Chinese | WPRIM | ID: wpr-958655

ABSTRACT

Objective:The characteristics of women with false elevated testosterone were analyze and the literature was reviewed to provide reference for clinical laboratory identification of false elevated testosterone.Methods:The characteristics of three patients with false elevated testosterone in Peking Union Medical College Hospital were analyzed retrospectively, and the results of different detection platforms and methods for the determination of testosterone levels were compared. International and domestic literatures related to false elevation of testosterone and detection methods of testosterone were searched for a comprehensive analysis from PUBMED and CNKI.Results:The levels of testosterone in 3 female patients were elevated by immunoassay and normal by mass spectrometry. They were excluded from the diagnosis of hyperandrogenemia. A total of 38 literatures related to testosterone detection were retrieved, of which 9 case reports of pseudohyperandrogenemia, among which 12 cases of pseudohyperandrogenemia were reported in 2 domestic literatures in 2021. All cases were confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Previous studies have clearly indicated that the result of routine immunoassay in clinical laboratory for the determination of female testosterone have poor correlation with the results of LC-MS/MS, with varying degrees of deviation.Conclusions:Immunoassay tests for female testosterone is susceptible to interference and lead to elevated false results. It is suggested that clinical laboratories evaluate the detection methods used and establish a identification program, and confirm samples with suspected pseudoelevated testosterone elevation using other immune platforms or LC-MS/MS.

18.
Article in Chinese | WPRIM | ID: wpr-957205

ABSTRACT

Objective:To synthesize a novel site-specifically labelled probe 68Ga-1, 4, 7, 10-tetraazacyclododecane-1, 4, 7, 10-tetraacetic acid (DOTA)-Cys-Asp-Val (CDV)-Nb109 and explore its potential for detection of the programmed cell death ligand 1 (PD-L1) expression level in different tumors. Methods:Firstly, CDV was inserted into the tail of the sequence of Nb109 by genetic engineering. Then the precursor DOTA-CDV-Nb109 was prepared by mixing the maleimide-DOTA and the single-domain antibody CDV-Nb109 (amount of substance ratio 1∶1) via the maleimide-cysteine site-specific coupling strategy. Subsequently, the DOTA-CDV-Nb109 was labeled with 68Ga and purified by PD-10 column. Human melanoma A375, human PD-L1 transfected melanoma A375-hPD-L1 and human glioma U87 tumor-bearing mice models were established, and the diagnostic value of 68Ga-DOTA-CDV-Nb109 was evaluated by stability assay, cellular uptake, and microPET imaging. One-way analysis of variance and the least significant difference t test were used to analyze the data. Results:The probe 68Ga-DOTA-CDV-Nb109 was obtained with the radiochemical yield of (69.79±4.69)%, radiochemical purity more than 97%, and molar activity of (12.85±1.51) GBq/μmol. 68Ga-DOTA-CDV-Nb109 had strong binding affinity for A375-hPD-L1 with the dissociation constant ( Kd) of (66.43±17.89) nmol/L. The uptake of 68Ga-DOTA-CDV-Nb109 in A375-hPD-L1 and U87 cells were (3.17±0.15) percentage of the added radioactivity dose (%AD) and (2.08±0.03) %AD respectively, which were significantly higher than that in A375 cells ((1.21±0.14) %AD; F=82.87, t values: 15.23, 9.98, P values: <0.001, 0.003). The tumor uptake of the probe in A375-hPD-L1 ((5.21±0.35) percentage of injected dose per ml (%ID/ml)) and U87 tumor-bearing mice ((3.44±0.69) %ID/ml) were significantly higher than that in A375 tumor-bearing mice ((2.17±0.36) %ID/ml; F=249.72, t values: 35.70, 3.43, both P<0.001). Conclusion:The site-specifically labelled probe 68Ga-DOTA-CDV-Nb109, which can non-invasively and dynamically monitor the change of PD-L1 expression level in different tumors and help screen patients who can benefit from PD-L1 immune checkpoint blocking therapy, is successfully synthesized with high radiochemical purity.

19.
Article in Chinese | WPRIM | ID: wpr-991113

ABSTRACT

Despite advances in immunotherapy for the treatment of cancers,not all patients can benefit from programmed cell death ligand 1(PD-L1)immune checkpoint blockade therapy.Anti-PD-L1 therapeutic effects reportedly correlate with the PD-L1 expression level;hence,accurate detection of PD-L1 expression can guide immunotherapy to achieve better therapeutic effects.Therefore,based on the high affinity antibody Nb109,a new site-specifically radiolabeled tracer,68Ga-NODA-cysteine,aspartic acid,and valine(CDV)-Nb109,was designed and synthesized to accurately monitor PD-L1 expression.The tracer 68Ga-NODA-CDV-Nb109 was obtained using a site-specific conjugation strategy with a radiochemical yield of about 95%and radiochemical purity of 97%.It showed high affinity for PD-L1 with a dissociation constant of 12.34±1.65 nM.Both the cell uptake assay and positron emission tomography(PET)imaging revealed higher tracer uptake in PD-L1-positive A375-hPD-L1 and U87 tumor cells than in PD-L1-negative A375 tumor cells.Meanwhile,dynamic PET imaging of a NC1-H1299 xenograft indicated that doxorubicin could upregulate PD-L1 expression,allowing timely interventional immunotherapy.In conclusion,this tracer could sensitively and dynamically monitor changes in PD-L1 expression levels in different cancers and help screen patients who can benefit from anti-PD-L1 immunotherapy.

20.
Article in Chinese | WPRIM | ID: wpr-885906

ABSTRACT

Reflex tests are ordered when a particular test result indicates that additional testing should be performed according to the guidelines or the feedback process formulated by clinical consultation. The application scope of the reflex tests involves various subspecialties of laboratory medicine. The clinical application needs the support of qualified laboratory doctors, comprehensive information and financial system, clinical guidelines, and so on. Active application of reflex tests can promote the standardization of evidence-based medicine in clinical practice, save medical resources, and shorten the diagnosis and treatment time of patients.

SELECTION OF CITATIONS
SEARCH DETAIL