Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Article in English | WPRIM | ID: wpr-1042098

ABSTRACT

Purpose@#This study aimed to determine the optimal cutoff points for age and tumor size of patients with intrahepatic cholangiocarcinoma (ICC) and to establish and verify a predictive nomogram of overall survival at 1, 3, and 5 years. @*Methods@#From the SEER (Surveillance, Epidemiology, and End Results) database, 1,325 ICC patients were selected and randomly divided into training and testing cohorts at a 7:3 ratio. Using the X-tile software, age and tumor size were classified into 3 subgroups: ≤61, 62–74, and ≥75 years and ≤35, 36–55, and ≥56 mm. Subsequently, univariate and multivariate Cox regression analyses were performed using the R software in the training cohort to determine independent risk factors, compile the prediction nomogram, and verify it with the testing cohort findings. @*Results@#The C-indexes of the new prediction nomograms in the training and testing cohorts were 0.738 (95% confidence interval [CI], 0.718–0.758) and 0.750 (95% CI, 0.72–0.78), respectively. Furthermore, the areas under the 1-, 3-, and 5-year receiver operating characteristic (ROC) curves based on the nomogram were 0.792, 0.853, and 0.838, respectively, higher than the ROC based on the 7th and 8th editions of the American Joint Cancer Commission (AJCC) staging system. @*Conclusion@#This study established and verified a prognostic nomogram that improved the accuracy of the 1-, 3-, and 5-year survival predictions for ICC patients, compared with that based on the 7th and 8th editions of the AJCC staging system, and can help clinicians make personalized survival predictions.

2.
Article in Chinese | WPRIM | ID: wpr-995800

ABSTRACT

Objective:To develop a national secondary reference material of Urea and Creatinine in frozen human serum as a standard for metrological traceability.Methods:According to JJF1343-2012 "General and Statistical Principles for Characterization of Reference Materials" and JJF 1006-1994 " Technical Norm of Primary Reference Material ", the homogeneity, stability, and commutability were evaluated;Using the JCTLM recommended methods, the value of the reference materials was assigned through collaboration with 6 accredited reference laboratories from Guangdong Provincial Hospital of Chinese Medicine, Beijing Aerospace General Hospital, Shenzhen Mindray Bio-Medical Electronics, Maccura Biotechnology, Beijing Leadman Biochemistry, and Zhejiang MedicalSystem Biotechnology. Uncertainty components including inhomogeneity, stability and value assignment were evaluated.Results:The results of one-way analysis of variance of homogeneity for the reference materials showed P>0.05, and the stability evaluation was less than the critical value of the t-test. The measured values were in the 95% confidence interval in the four conventional detection systems for commutability, and the certified values and expanded uncertainties were urea:(14.7±0.3) mmol/L ( k=2),Cr:(313.9±14.5) μmol/L ( k=2). Conclusion:The prepared secondary reference materials of urea and creatinine had promising homogeneity, stability, and commutable, the values of urea and creatinine concentration in reference materials were accurate and reliable.

3.
China Pharmacy ; (12): 3051-3053, 2016.
Article in Chinese | WPRIM | ID: wpr-504862

ABSTRACT

OBJECTIVE:To study the percutaneous absorption of 0.03% Tacrolimus ointment,and to compare the difference of domestic test preparation and imported reference preparation. METHODS:Modified Franz diffusion cells were adopted in trans-dermal test in vitro;HPLC-MS method was used to determine permeation amount and rate in vitro,delay time of domestic test preparation and imported reference preparation 0.03%Tacrolimus ointment. RESULTS:24 h in vitro permeation amount of test and reference preparations were(3 907±1 191)and(3 896±1 064)ng/cm2;permeation rates were 186.7 and 182.9 ng/(cm2·h);de-lay time were 1.95 and 2.00 h,respectively(P>0.05). CONCLUSIONS:Test preparation shows good percutaneous property,and is similar to reference preparation in penetration absorbency through nude mice skin.

4.
Herald of Medicine ; (12): 640-643, 2015.
Article in Chinese | WPRIM | ID: wpr-464298

ABSTRACT

Objective To optimize purification technology of total flavonoids in Callicarpa nudiflora Hook. et Arm. by macroporous adsorption resin. Methods Macroporous resin models including AB-8, D-101, HP-20, HP2MG, were optimized by static adsorption and desorption experiments regarding to adsorption rate and desorption rate of total flavonoids. Purification technology parameters of total flavonoids were optimized by single factor test. Results HP-20 macroporous resin presented the best purification efficiency,the optimum purification conditions were that taking 4. 46 mg·mL-1 of total flavonoidsat pH 3. 0, loading at 3 BV·h-1, washed with 3BV of water at 3 BV·h-1,then eluted with 4 BV 75% ethanol at 2 BV·h-1, finally obtaining the total flavonoids from the dry extract of Callicarpa nudiflora Hook. et Arn. with the purity of 47. 4%. Conclusion HP-20 macroporous resin is suitable for preliminary purification of total flavonoids in Callicarpa nudiflora Hook. et Arn.

SELECTION OF CITATIONS
SEARCH DETAIL