Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
The Journal of Practical Medicine ; (24): 2070-2073, 2018.
Article in Chinese | WPRIM | ID: wpr-697891

ABSTRACT

Objective To evaluate the feasibility of quantitative evaluation of fallopian tubes patency by the rising slope of pressure curve produced by bolus injection using a liquid diagnostic apparatus in the four-dimen-sional hysterosalpingo-contrast sonography. Methods A total of 205 patients with infertility were collected for four-dimensional hysterosalpingo-contrast sonography. In the examination,the contrast medium concentration,the liquid volume of the liquid diagnostic apparatus and the speed of the liquid were stationary calculated. The rising slope of the curve was calculated according to the real-time pressure curve produced by the contrast agent injection process. According to the hysterosalpingo-contrast sonography examination's results ,patients were divided into one side patency group,one side partial obstruction group and one side obstruction group. The correlation between the slope and the patency of the fallopian tube was analyzed by binary logistic regression. Results Binary logistic regression showed that the slope and fallopian tube patency had good correlation(all P < 0.05)between one side patency group and one side obstruction group,and also between one side partial obstruction group and one side obstruction group;but had no correlation between one side patency group and one side partial obstruction group(regression coefficient P>0.05,regression constant P=0.000). Conclusion The slope of pressure curve produced by four-dimensional hysterosalpingo-contrast sonography can be used to assess the patency of fallopian tubes quantitatively. It is a new auxiliary index for evaluating the patency of fallopian tubes.

2.
Chinese Journal of Medical Imaging ; (12): 474-477,480, 2017.
Article in Chinese | WPRIM | ID: wpr-614916

ABSTRACT

Purpose To investigate the adverse reactions and management in the process of transvaginal real-time three-dimensional hysterosalpingo-contrast sonography (3D-HyCoSy).Materials and Methods A total of 976 patients with infertility accepting 3D-HyCoSy in Jiangsu Provincial Hospital of Traditional Chinese Medicine,Affiliated Hospital of Nanjing University of Traditional Chinese Medicine,from December 2014 to August 2016 were retrospectively analyzed.The pain degree was evaluated using visual analog scale (VAS).Adverse reactions,including contrast countercurrent,vomiting,syncope and allergies,were recorded.The relationship between adverse reactions and ultrasound imaging signs was explored.Results There were 66 cases (6.76%) of VAS grade 0,346 cases of mild pain (35.45%),374 cases of moderate pain (38.32%) and 190 cases (19.47%) of severe pain.With the increase in the degree of tubal obstruction,the degree of pain gradually increased.Pain was the most common adverse reaction among patients,followed by vomiting (15 cases,1.54%),syncope (1 case,0.10%),and allergies (1 case,0.10%).The incidence of contrast countercurrent was 12.30% (120 cases).The adverse reaction incidence of patients with abnormal ultrasound imaging signs was significantly higher than that of patients with normal signs (x2=29.02,P<0.01).Conclusion With the extensive use of 3D-HyCoSy examination,its clinical application value has attracted a lot of attention,meanwhile,the understanding of its safety and related adverse reactions should also be improved.The state of patients should be closely observed before,during and after 3D-HyCoSy.Medical personnel should watch out for syncope and allergic reactions,and prepare for emergency management.

SELECTION OF CITATIONS
SEARCH DETAIL