ABSTRACT
Purpose@#In the present study, we determined the prevalence of obstructive meibomian gland dysfunction (MGD), hyposecretory MGD, grossly normal MG, and hypersecretory MGD in patients with dry eye syndrome using lipid layer thickness (LLT) and MG dropout. @*Methods@#Eighty-eight patients with dry eye syndrome were included in the study. Patients were categorized into four groups according to the LLT and weighted total meiboscore. The proportion of patients in each group was calculated. The age, sex, Ocular Surface Disease Index, LLT, Schirmer, tear film breakup time, cornea stain, weighted total meiboscore, expressibility, and quality of meibum were compared between the four groups. @*Results@#Fifteen eyes (17.0%) had obstructive MGD, two eyes (2.3%) had hyposecretory MGD, 40 eyes (45.5%) had grossly normal MG, and 17 eyes (19.3%) had hypersecretory MGD. The obstructive MGD group was younger than the grossly normal MG group. In obstructive MGD, the ratio of men to women was higher than that of the other groups. However, Ocular Surface Disease Index, Schirmer, tear film breakup time, and corneal stain did not show statistically significant differences between the four groups. The meibum expressibility of the hyposecretoy MGD group was worse than those of the other groups. The meibum expressibility of the hyposecretoy MGD group was poor than those of the obstructive and hypersecretory MGD group. @*Conclusions@#This categorization was expected to help determine the best treatment method for dry eye syndrome, according to the MG status.
ABSTRACT
Purpose@#In the present study, we introduce human lacrimal gland imaging using an ultrasound biomicroscopy (UBM) with a soft cover and show their findings @*Methods@#The representative UBM findings of palpebral lobes in seven subjects (four with non-Sjögren dry eye syndrome, one with Sjögren syndrome, and two healthy subjects) were described in this study. To prolapse the palpebral lobe, the examiner pulled the temporal part of the upper eyelid in the superotemporal direction and directed the subject to look in the inferonasal direction. We scanned the palpebral lobes longitudinally and transversely using UBM. We used an Aviso UBM with a 50 MHz linear probe and ClearScan. @*Results@#In UBM of two healthy subjects, the echogenicity of the lacrimal gland was lower than that of the sclera and homogeneous. But the parenchyma of a patient with Sjögren dry eye syndrome was quite inhomogeneous compared to the healthy subjects. In two patients with dry eye syndrome, we were able to observe some lobules in the parenchyma. We could find excretory ducts running parallel at the surface of the longitudinal section in some subjects. In the longitudinal UBM scan of a subject, we observed a tubular structure at a depth of 1,500 μm that was considered a blood vessel. It ran from the superonasal to the inferotemporal direction. In a subject, we observed a large cyst beneath the conjunctiva. @*Conclusions@#Lacrimal gland imaging using UBM has both advantages of optical coherence tomography and sonography, and could be useful for evaluating dry eye syndrome.
ABSTRACT
Purpose@#To compare the clinical outcomes of penetrating keratoplasty (PKP) and Descemet stripping automated endothelial keratoplasty (DSAEK) in eyes with Glaucoma Ahmed Valve implants. @*Methods@#The charts of 11 patients who underwent PKP and 11 who underwent DSAEK between February 2016 and June 2018 were retrospectively reviewed; all patients previously underwent Ahmed valve implant surgery. The best corrected visual acuity, intraocular pressure, and endothelial cell count were compared 1, 3, and 6 months after surgery. Graft rejection and graft failure were also evaluated during follow-up. The survival rates were compared using Kaplan–Meier survival analysis. @*Results@#The difference in graft survival rates of the PKP and DSAEK groups was not significant (p = 0.295); however, graft failure occurred earlier in the PKP group (12.9 ± 10.1 vs. 18.8 ± 5.3 months). The postoperative best corrected visual acuity of the PKP group had improved at 1 (p = 0.027) and 3 (p = 0.017) months, while the DSAEK group showed significant improvement at 1, 3, and 6 months (all p = 0.005). Intergroup analysis showed better visual prognosis of the DSAEK group at 1, 3, and 6 months after surgery (p = 0.023, p = 0.007, and p = 0.004, respectively). @*Conclusions@#In our study, the two corneal transplantation methods did not have significantly different graft survival rates; however, graft failure occured later in the DSAEK group and the postoperative visual acuity was better than in the PKP group. Although further study is needed, performing DSAEK in patients with an Ahmed valve implant seems to be a good alternative to PKP.
ABSTRACT
PURPOSE: To compare the anterior capsule contraction and intraocular lens (IOL) decentration among three types of IOL to determine the influence of haptic design on anterior capsule stability. METHODS: One hundred fifty patients were enrolled in this prospective, randomized study and 260 eyes underwent implantation of one of the following IOLs: modified L-haptic IOL (n = 74), modified C-haptic IOL (n = 97), or a plate-haptic IOL (n = 89). The area of the anterior capsule opening, IOL decentration, and capsule overlap were measured using retroillumination photospot 1 day and 2 months after cataract surgery. RESULTS: The area of capsule opening at postoperative day 1 was significantly different between the three IOLs (p < 0.01). All IOLs showed reduction of the anterior capsule opening from 1 day to 2 months after surgery, and greater reduction was shown in the modified C-haptic IOL (p < 0.001). At postoperative month 2, IOL decentration was significantly different between the IOLs and showed a positive correlation with the mean area reduction during month 2. CONCLUSIONS: The degree of anterior capsule contraction and IOL decentration in modified L-haptic IOLs were less than those in modified C-haptic IOLs and comparable to those in plate-haptic IOLs.
Subject(s)
Humans , Cataract , Lenses, Intraocular , Prospective StudiesABSTRACT
PURPOSE: To evaluate and compare the efficacy and safety of cyclosporine 0.05% (Cyporin N eye drops 0.05%) to an active comparator (Restasis®) in moderate to severe dry eye patients. METHODS: This is a multicenter, randomized, double-blind, parallel, active control, non-inferiority, phase III study. Patients had a 2-week run-in period (during the run-in period, patients used artificial tears, if applicable), and afterward 158 patients were randomly assigned treatment for 12 weeks with cyclosporine 0.05% (with artificial tears, if applicable), in which the efficacy and safety were evaluated every four weeks. RESULTS: Corneal staining tests showed that in the per protocol set group, the study group was not inferior to the control group; the results for the full analysis set analytic group were the same. The number of adverse events reported from the 158 patients was not significantly different between groups (p = 0.1107). Additionally, other evaluations, including tolerability evaluations, clinical pathology examinations, and vital signs, show that there is no difference in terms of safety between the groups. CONCLUSIONS: Cyclosporine A 0.05% (Cyporin N eye drops 0.05%) is considered to have the same efficacy and safety compared to the active comparator.
Subject(s)
Humans , Cyclosporine , Dry Eye Syndromes , Lubricant Eye Drops , Ophthalmic Solutions , Pathology, Clinical , Vital SignsABSTRACT
PURPOSE: To evaluate the prevalence of dry eye in patients before allogeneic hematopoietic stem cell transplantation (aHSCT) and changes in ocular surface in the acute stage after aHSCT. METHODS: We evaluated 56 eyes of 28 patients after aHSCT at a tertiary hospital. All patients underwent a full ophthalmic examination at 1 month before aHSCT (baseline) and 1, 2 and 3 months after aHSCT and answered the ocular surface disease index (OSDI) questionnaire to assess ocular involvement in the form of dry eye syndrome or any other ocular manifestation at each visit. Subjects were divided into 2 groups depending on the presence of dry eye at baseline. The main outcome measures were best-corrected visual acuity, tear break-up time, corneal fluorescein staining, Schirmer test, tear osmolarity and OSDI questionnaire. RESULTS: Dry eye was already present in 40 eyes of 20 patients (71.4%) suffering from hematological disease before aHSCT. Tear osmolarity was significantly increased at 1, 2 and 3 months after aHSCT compared with baseline in the dry eye group (each p < 0.01). Tear osmolarity also increased at 2 months after aHSCT and tear break-up time decreased at 3 months after aHSCT, which were statistically significant (p = 0.01 and p = 0.02, respectively). Other changes in ocular surface indices were not statistically significant. CONCLUSIONS: In the acute stage, changes in ocular surface indices such as Schirmer test and OSDI were not statistically significant. However, significant changes in tear osmolarity in both groups indicate that ophthalmic examination 1 or 2 months after aHSCT is recommended. Additionally, aggressive treatment is warranted when patients have dry eyes at baseline.