ABSTRACT
Objective:To investigate the consistency of myocardial extracellular volume between systole and diastole using dual-layer detector spectral CT.Methods:This was a cross-sectional study. Thirty-five patients who underwent cardiac spectral CT examination in West China Hospital of Sichuan University from April 2022 to December 2022 were retrospectively collected. Hematocrit was collected within 3 days before the CT scan. The delayed phases holographic spectral images in systole (45%) and diastole (75%) were obtained using dual-layer spectral CT. CT data were processed using a spectral post-processing workstation, and the extracellular volume (ECV) based on iodine density images, referred as CT-ECV, in systolic and diastolic phases were calculated, respectively. According to the American Heart Association′s 16-segment model of left ventricular, the standard short-axis images were constructed, and the myocardium was standardized into 16 segments at the basal, mid-cavity, and apical levels of the left ventricle. Two radiologists performed a subjective evaluation in the image quality of the CT-ECV images of the whole heart and the three sections in systole and diastole using a "five-point" scale. The ECV of the 16 segments and the whole heart in systole and diastole was calculated. The consistency of subjective evaluations between systole and diastole was assessed using Kappa statistics. Wilcoxon signed-rank tests were used to compare the differences in scores between systole and diastole. Paired sample t-test was used to compare the differences in CT-ECV scores between systole and diastole. The intraclass correlation coefficient was used to test the intra-and inter-observer consistency of CT-ECV measurements between two radiologists. P<0.05 was statistically significant. Results:There was good agreement between the two radiologists on subjective scores of CT-ECV image quality between systole and diastole ( Kappa>0.80), and there was no statistical difference in image quality among the basal, mid-cavity, and apical levels of the left ventricle and whole heart between systole and diastole ( P>0.05). The systolic and diastolic CT-ECV for the entire heart obtained through the delay phase were (33.29±3.46)% and (33.50±3.39)%, respectively, with no statistically significant difference ( t=-0.78, P=0.442). CT-ECV in systole and diastole were (34.15±3.94)% and (35.30±3.99)% for segment 8, (34.03±3.76)% and (35.46±3.74)% for segment 9, and (33.98±3.32)% and (35.05±3.98)% for segment 14, respectively. The mean values of the systolic CT-ECV of segments 8, 9 and 14 were significantly lower than those of diastolic CT-ECV ( t=-2.65, -3.26, -2.42, P=0.012, 0.003, 0.022, respectively). The ICCs for CT-ECV measurements of 16 segments by the two radiologists were greater than 0.90 in both systolic and diastolic, indicating good agreement. Conclusions:There is no significant difference in whole heart CT-ECV values between systolic and diastolic myocardial ECV based on dual-layer spectral CT. However, minor differences (less than 2%) are found between systolic and diastolic myocardial CT-ECV for some segments. Myocardial CT-ECV measurement should be performed on the same segment during the same phase to obtain stable and accurate ECV values.
ABSTRACT
Objective To investigate the value of "one-stop" scanning of coronary and head and neck CTA in patients with normal body mass index (18 kg/m2 ≤ BMI ≤ 25 kg/m2) using low tube voltage (80 kVp).Methods In a retrospective analysis 80 patients with normal body mass index who had completed "one-stop" scanning of coronary and head and neck CTA were divided into A and B groups according to different scanning method,and 40 consecutive cases were selected in each group.Scanning parameters of group A and group B were tube voltage 80 kV,coronary CTA tube current 550 mA,head and neck CTA tube current 500 mA,and tube voltage 100 kV,coronary CTA tube current 450 mA,head and neck CTA tube current 400 mA separately.Subjective evaluation and objective evaluation were performed on the image quality of the two groups.CT values of coronary artery and head and neck CTA trunk branch vessel,contrast-to-noise ratio (CNR),image noise (SD) and effective dose between the two groups were compared.Results The image quality of both groups met the diagnostic requirements,and there was no statistically significant difference in subjective scores between two groups (P>0.05).The CT values of coronary arteries,the main branches of the head and neck (the common carotid artery,the internal carotid artery) and SD of head and neck CTA were significantly different between two groups (t=4.737,6.552,3.359,2.165,2.685,4.617,P<0.05).There was no statistically significant difference in SD of coronary CTA,CT values and CNR between head and neck vessels (middle cerebral artery) in group A and group B (P>0.05).The effective dose of coronary CTA in group A (1.16±0.20) mSy was reduced by 51.1% than that in group B (2.37±0.77) mSv.The effective dose of head and neck CTA in group A (0.37±0.03) mSv was reduced by 47.9% than that in group B (0.71 ± 0.17) mSv.Conclusions The image quality with subjective evaluation met the diagnostic requirements when using a low-tube voltage for "one-stop"scanning of coronary and head and neck CTA.The CNR values were basically consistent with the conventional scanning method,and the patient effective dose was reduced by about 50%.
ABSTRACT
<p><b>BACKGROUND</b>Debate on treatment for young patients with coronary artery disease still exists. This study aimed to investigate the intermediate- and long-term outcomes between coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI) in patients aged 18-45 years with diabetes mellitus (DM).</p><p><b>METHODS</b>Between January 2006 and March 2016, a total of 2018 DM patients aged 18-45 years including 517 cases of CABG and 1501 cases of PCI were enrolled in the study. Using propensity score matching (PSM), 406 patients were matched from each group. The intermediate- and long-term data were collected. The primary end point of this study was long-term death. The secondary end points included long-term major adverse cardiovascular and cerebrovascular events (MACCEs), stroke, angina, myocardial infarction (MI), and repeat revascularization.</p><p><b>RESULTS</b>Before PSM, the in-hospital mortality was 1.2% in the CABG group and 0.1% in the PCI group, with statistically significant difference (P < 0.0001). The 10-year follow-up outcomes including long-term survival rate and freedom from MACCEs were better in the CABG group than those in the PCI group (97.3% vs. 94.5%, P = 0.0072; 93.2% vs. 86.3%, P < 0.0001), but CABG group was associated with lower freedom from stoke compared to PCI group (94.2% vs. 97.5%, P = 0.0059). After propensity score-matched analysis, these findings at 10-year follow-up were also confirmed. Freedom from MACCEs was higher in CABG group compared to PCI group, but no significant difference was observed (93.1% vs. 89.2%, P = 0.0720). The freedom from recurrent MI was significantly higher in CABG patients compared with PCI patients (95.6% vs. 92.5%, P = 0.0260). Furthermore, CABG was associated with a higher rate of long-term survival rate than PCI (97.5% vs. 94.6%, P = 0.0403). There was no significant difference in the freedom from stroke between CABG and PCI groups (95.3% vs. 97.3%, P = 0.9385). The hospital cost was greater for CABG (13,936 ± 4480 US dollars vs. 10,926 ± 7376 US dollars, P < 0.0001).</p><p><b>CONCLUSIONS</b>In DM patients aged 18-45 years, the cumulative survival rate, and freedom from MI and repeat revascularization for CABG were superior to those of PCI. However, a better trend to avoid stroke was observed with PCI.</p>
ABSTRACT
Adolescent idiopathic scoliosis(AIS)is a complex three-dimensional spinal deformity,characterized by lateral curvature and vertebral rotation.The medical imaging techniques are essential for determination of severity of scoliotic spine, prediction of progression and assistance in the decision-making process of treatment for scoliosis, including radiograph, stereoradiography, computed tomography, magnetic resonance imaging and ultrasound.This paper reviewed their application from the view of measure parameters,reliability and va-lidity,as well as merits and demerits.It is possible to assess the three-dimensional nature of scoliosis in the future.
ABSTRACT
<p><b>OBJECTIVE</b>To determine the clinical characteristics and outcomes of redo CABG.</p><p><b>METHODS</b>The outcomes of 42 consecutive patients who underwent redo CABG from January 2002 to December 2010 was analyzed. There were 29 males and 13 females, aging from 46 to 78 years old with a mean of (61.2 ± 2.1) years. Off-pump CABG was applied for 31 patients and on-pump CABG for 11 patients. There were 1 patient underwent concomitant aortic valve replacement and 1 patient underwent aortic root and right aortic arch replacement respectively.</p><p><b>RESULTS</b>Three patients died of right ventricle rupture, heart failure and multiple system organ failure respectively and the perioperative mortality rate was 4.8%. The post-operatively mechanical ventilation time varied from 9 to 27 h with a mean of (17 ± 7) h. There was no residual angina and perioperative myocardial infarction in the remaining patients who were all discharged uneventfully. Intraoperative 6 patients had accepted intraaortic balloon counterpulsation. During the follow-up from 6 months to 4.5 years for 38 patients, which showed no evidence of recurrent angina and postoperative coronary CT angiography in 12 patients showed the patency of grafts is good.</p><p><b>CONCLUSION</b>Satisfactory outcome of redo coronary artery bypass grafting can be achieved if proper indication were choose and reasonable management were performed.</p>
Subject(s)
Aged , Female , Humans , Male , Middle Aged , Cardiopulmonary Bypass , Coronary Artery Bypass , Coronary Restenosis , General Surgery , Reoperation , Treatment OutcomeABSTRACT
Objective To explore the effect of polyethylene glycol-polyethyleneimine (PEG-PEI) serving as a non-viral vector in delivering small interfering RNA (siRNA) into C17.2 neural stem cells (NSCs) in vitro. Methods Complexes of PEG-PEI and siRNA targeting Nogo receptor were prepared, and their characterizations were estimated by measurements of particle size and zeta potential,and the complex abilities of PEG-PEI/siRNA complexes were observed by gel retardation assay. In addition, with liposome complex system (Lipofectamine 2000/siRNA) as positive control, the transfection efficiency of PEI-PEG/siRNA complexes at different N/P ratios (cationic nitrogen/siRNA phosphate molar ratio) was detected by flow cytometry. Results The siRNA molecules were condensed by PEG-PEI to form nanoseale complexes. As the proportion of N/P ratio enhancing, the surface potential of nanoparticles gradually increased and the particle sizes of PEI-PEG/siRNA complexes showed a decreasing trend. Gel retardation electrophoresis suggested that siRNA could be fully composited with PEG-PEI as a result of the coulombic foree between them. Meanwhile, flow cytometry experiments revealed that the transfection efficiency of PEG-PEI mainly depended on N/P ratios of the nanoparticles,and the highest one was obtained at N/P=15 ([78.72±8.18)]%). Conclusion PEG-PEI might be a prospective candidate for siRNA delivery system, which enjoys its value in NSC gene therapy.
ABSTRACT
<p><b>OBJECTIVE</b>To study the feasibility of MRI of human colon adenocarcinoma cell line (Lovo) labeled with superparamagnetic iron oxide(SPIO) nanoparticles in vitro.</p><p><b>METHODS</b>Lovo cells (5 × 10(5) and 1 × 10(6)) were cultured in medium containing different SPIO nanoparticles (50 microl and 500 microl). Transmission electron microscopy was used to observe cellular ultrastructure and to determine the uptake and distribution of particles in Lovo cells at 1-, 3-, 6-hours. MRI of Lovo cells was performed with T1WI, T2WI sequences. Unlabeled cells were used as controls.</p><p><b>RESULTS</b>Uptake of SPIO nanoparticles occurred within 6 hours. On T1 weighted imaging, there was no significant difference in signal intensity between the experimental groups and the control group. On T2 weighted imaging, there was no significant difference in signal intensity between the experimental groups and the control group after culture of 1 h. Signal intensity began to decrease in 1 × 10(6) Lovo cells labeled with 500 microl SPIO nanoparticle after 3 hours culture. Signal intensity decreased in all the experimental groups after 6 hours culture.</p><p><b>CONCLUSION</b>Human colon adenocarcinoma cell line (Lovo) can be labeled with SPIO nanoparticles, and the labeled cells can be imaged with MRI equipment.</p>
Subject(s)
Humans , Adenocarcinoma , Pathology , Cell Line, Tumor , Colonic Neoplasms , Pathology , Iron , Magnetic Resonance Imaging , Methods , Magnetics , Nanoparticles , Oxides , Pilot Projects , Staining and Labeling , MethodsABSTRACT
<p><b>OBJECTIVE</b>To summarize the clinic characteristics and effect of surgical repair of ruptured aortic sinus aneurysm.</p><p><b>METHODS</b>From September 1997 to September 2007, 43 patients with ruptured aortic sinus aneurysm underwent surgical procedures. There were 32 male and 11 female patients. The age ranged from 11 to 50 years old with a mean of (29.0 +/- 11.5) years old. The origins of rupture were the right coronary sinus in 34 patients and the noncoronary sinus in 9 patients. The aneurysms ruptured into the right ventricle in 30 patients, the right atrium in 8 patients, the right ventricle and right atrium in 3 patients, and the ventricular septum and then the right ventricle in 2 patients. Associated cardiac anomalies included ventricular septal defect in 26 patients, aortic regurgitation in 15 patients, infectious endocarditis in 8 patients, tricuspid regurgitation in 6 patients, atrial septum defect in 4 patients, mitral valve regurgitation in 2 patients, patent ductus arteriosus in 2 patients, and pulmonary valve vegetation in 1 patient. All the patients underwent the repair of ruptured aortic sinus aneurysm and correction of associated anomalies with cardiopulmonary bypass.</p><p><b>RESULTS</b>There were no deaths after the operation and during the follow-up. The complications, including acute heart failure and III atrioventricular block, occurred in 5 patients. Follow-up was 6 to 120 months with a mean of (68.0 +/- 17.7) months. Two patients underwent reoperation for aortic valve replacement at the 6(th) and 8(th) year after the first operation. There were 2 patients which the aortic regurgitation deteriorated from grade I to II.</p><p><b>CONCLUSIONS</b>Repair of ruptured aortic sinus aneurysm presents a satisfactory result. Aggressive treatment in early time, prevention of post-operative complications and long-term follow-up are recommended in the treatment for patients of ruptured aortic sinus aneurysm with infectious endocarditis and aortic regurgitation.</p>