Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 86
Filter
2.
Arq. bras. cardiol ; 117(3): 561-598, Sept. 2021. tab, graf
Article in English, Portuguese | SES-SP, LILACS, SES-SP, CONASS, SESSP-IDPCPROD, SES-SP | ID: biblio-1339180
3.
ABC., imagem cardiovasc ; 34(4): eabc256, 2021. tab
Article in Portuguese | LILACS | ID: biblio-1359750

ABSTRACT

Fundamento: A ecocardiografia transtorácica (ETT) pode desempenhar um papel crucial na avaliação das manifestações cardíacas da COVID-19. Objetivo: Nosso objetivo foi relatar a prevalência das principais anormalidades ecocardiográficas em pacientes hospitalizados com COVID-19. Métodos: Realizou-se estudo observacional multicêntrico prospectivo com pacientes com COVID-19 submetidos a ETT durante a internação. Pacientes com insuficiência cardíaca prévia, doença arterial coronariana ou fibrilação atrial foram classificados como portadores de doença cardiovascular (DCV) prévia. Foram coletados dados clínicos e ecocardiográficos da estrutura e da função cardíaca. Resultados: Avaliamos 310 pacientes com COVID-19, com 62±16 anos de idade, 61% homens, 53% com hipertensão arterial, 33% com diabetes e 23% com DCV prévia. No total, 65% dos pacientes necessitaram de suporte em unidade de terapia intensiva. As alterações ecocardiográficas mais prevalentes foram hipertrofia do ventrículo esquerdo (VE) (29%), hipertensão pulmonar (25%), disfunção sistólida do VE (16,5%), disfunção sistólica do ventrículo direito (VD) (15,9%), disfunção diastólica do VE grau II/III (11%) e alteração da contratilidade regional do VE (11%). Derrame pericárdico foi incomum (7%). Hipertrofia do VE (25 vs. 45%, p=0,001), disfunção sistólica do VE (11 vs. 36%, p<0,001), alterações da contratilidade regional (6 vs. 29%, p<0,001), disfunção diastólica do VE grau II/III (9 vs. 19%, p=0,03) e hipertensão pulmonar (22 vs. 36%, p=0,019) foram menos comuns nos pacientes sem do que com DCV prévia. A disfunção sistólica do VD mostrou-se semelhante em pacientes sem e com DCV prévia (13 vs. 25%, p=0,07). Conclusões: Entre os pacientes hospitalizados com COVID-19, os achados ecocardiográficos anormais foram comuns, porém menos encontrados naqueles sem DCV. A disfunção sistólica do VD pareceu afetar de forma semelhante pacientes com e sem DCV prévia. (AU)


Background: Transthoracic echocardiography (TTE) may play a crucial role in the evaluation of cardiac manifestations of coronavirus disease 2019 (COVID-19). Objective: We aimed to report the prevalence of the main echocardiographic abnormalities of hospitalized COVID-19 patients. Methods: We performed a prospective multicenter observational study in patients with COVID-19 who underwent TTE during hospitalization. Patients with pre-existing heart failure, coronary artery disease, or atrial fibrillation were categorized as having previous cardiovascular disease (CVD). Clinical and echocardiographic data about cardiac structure and function were collected. Results: We evaluated 310 patients with COVID-19 (mean age, 62±16 years; 61% men; 53% with arterial hypertension; 33% with diabetes; and 23% with previous CVD). Overall, 65% of the patients required intensive care unit support. The most prevalent echocardiographic abnormalities were LV hypertrophy (29%), pulmonary hypertension (25%), left ventricular (LV) systolic dysfunction (16.5%), right ventricular (RV) systolic dysfunction (15.9%), grade II/III LV diastolic dysfunction (11%), and LV regional wall motion abnormality (11%). Pericardial effusion was uncommon (7% of cases). LV hypertrophy (25% vs. 45%, p=0.001), LV systolic dysfunction (11% vs. 36%, p<0.001), regional wall motion abnormalities (6% vs. 29%, p<0.001), grade II/III LV diastolic dysfunction (9% vs. 19%, p=0.03), and pulmonary hypertension (22% vs. 36%, p=0.019) were less common in patients without previous CVD. RV systolic dysfunction occurred at similar frequencies in patients with versus without previous CVD (13% vs. 25%, p=0.07). Conclusions: Among patients hospitalized with COVID-19, abnormal echocardiographic findings were common, but less so among those without previous CVD. RV systolic dysfunction appeared to affect similar proportions of patients with versus without previous CVD. (AU)


Subject(s)
Humans , Male , Adolescent , Adult , Middle Aged , Echocardiography/statistics & numerical data , COVID-19/complications , COVID-19/physiopathology , COVID-19/diagnostic imaging , Heart Failure/classification , Cardiovascular Diseases/history , Epidemiologic Factors , Demographic Data , Hypertrophy, Left Ventricular/diagnostic imaging , Ventricular Dysfunction, Right/diagnostic imaging , Diabetes Mellitus/history , Hypertension/history , Hypertension, Pulmonary/diagnostic imaging
5.
Int. j. cardiovasc. sci. (Impr.) ; 33(6): 637-647, Nov.-Dec. 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1143106

ABSTRACT

Abstract Background There has been an increase in the number of cases of Takotsubo syndrome (TTS) and of scientific publications on the theme over the last years. However, little is known about the status of this disease in Brazilian hospitals. Objective To assess mortality and major adverse cardiovascular events (MACE) during hospitalization and follow-up of TTS patients seen in a tertiary hospital in Brazil. Methods This was a retrospective, observational study on 48 patients. Clinical data, signs and symptoms, complementary tests, MACE and all-cause mortality were assessed on admission and during follow-up. Kaplan-Meier curves were used for analysis of all-cause mortality and risk for MACE at median follow-up. The 95% confidence interval was also calculated for a significance level of 5%. Results Mean age of patients was 71 years (SD±13 years), and most patients were women (n=41; 85.4%). During hospitalization, four patients (8.3%) died and five (10.4%) developed MACE. At median follow-up of 354.5 days (IQR of 81.5-896.5 days), the risk of all-cause mortality and MACE was 11.1% (95% CI= 1.8-20.3%) and 12.7% (95% CI= 3.3-22.3%), respectively. Conclusion TTS was associated with high morbidity and mortality rates in a tertiary hospital in Brazil, which were comparable to those observed in acute coronary syndrome. Therefore, the severity of TTS should not be underestimated, and new therapeutic strategies are required. Int J Cardiovasc Sci. 2020; [online].ahead print, PP.0-0

7.
Arq. bras. cardiol ; 115(4): 720-775, out. 2020. tab, graf
Article in Portuguese | SES-SP, LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1131346
9.
ABC., imagem cardiovasc ; 32(3): 198-208, jul.-set. 2019. ilus, tab
Article in Spanish | LILACS | ID: biblio-1006582

ABSTRACT

La ecocardiografía permite detectar y cuantificar la disfunción diastólica utilizando numerosos parámetros que parecen volver muy compleja esa tarea, particularmente en disfunciones más severas. En este artículo son revisados y actualizados los parámetros utilizados y los recursos tecnológicos disponibles. Es propuesto un algoritmo para orientar la incorporación progresiva de las variables necesarias de acuerdo con los hallazgos. La evaluación realizada, de manera metódica siguiendo un algoritmo adecuado, permite llegar al diagnóstico con elevada sensibilidad y especificidad en la casi totalidad de los casos, haciendo de la ecocardiografía el mejor método no invasivo para el diagnóstico y evaluación de esta frecuente disfunción


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Echocardiography/methods , Diagnosis , Aortic Valve , Pulmonary Veins , Stroke Volume , Echocardiography, Doppler/methods , Heart Ventricles , Mitral Valve , Cardiomyopathies
12.
Arq. bras. cardiol ; 112(4): 410-421, Apr. 2019. tab, graf
Article in English | LILACS | ID: biblio-1001291

ABSTRACT

Abstract Background: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias and normal ventricular function requiring heart rate correction alone. Objective: To assess the safety, efficacy, and effects of LV pacing using an active-fixation coronary sinus lead in comparison with RV pacing, in patients eligible for conventional pacemaker (PM) implantation. Methods: Randomized, controlled, and single-blinded clinical trial in adult patients submitted to PM implantation due to bradyarrhythmias and systolic ventricular function ≥ 0.40. Randomization (RV vs. LV) occurred before PM implantation. The main results of the study were procedural success, safety, and efficacy. Secondary results were clinical and echocardiographic changes. Chi-squared test, Fisher's exact test and Student's t-test were used, considering a significance level of 5%. Results: From June 2012 to January 2014, 91 patients were included, 36 in the RV Group and 55 in the LV Group. Baseline characteristics of patients in both groups were similar. PM implantation was performed successfully and without any complications in all patients in the RV group. Of the 55 patients initially allocated into the LV group, active-fixation coronary sinus lead implantation was not possible in 20 (36.4%) patients. The most frequent complication was phrenic nerve stimulation, detected in 9 (25.7%) patients in the LV group. During the follow-up period, there were no hospitalizations due to heart failure. Reductions of more than 10% in left ventricular ejection fraction were observed in 23.5% of patients in the RV group and 20.6% of those in the LV group (p = 0.767). Tissue Doppler analysis showed that 91.2% of subjects in the RV group and 68.8% of those in the LV group had interventricular dyssynchrony (p = 0.022). Conclusion: The procedural success rate of LV implant was low, and the safety of the procedure was influenced mainly by the high rate of phrenic nerve stimulation in the postoperative period.


Resumo Fundamento: Considerando-se os potenciais efeitos deletérios da estimulação do ventrículo direito (VD), a hipótese desse estudo é que a estimulação unifocal ventricular esquerda pelo seio coronário é segura e pode proporcionar melhores benefícios clínicos e ecocardiográficos aos pacientes com bradiarritmias que apresentam função ventricular normal, necessitando apenas da correção da frequência cardíaca. Objetivos: Avaliar a segurança, a eficácia e os efeitos da estimulação do ventrículo esquerdo (VE), utilizando um cabo-eletrodo com fixação ativa, em comparação à estimulação do VD. Métodos: Estudo clínico, randomizado, simples-cego em pacientes adultos com indicação de marca-passo (MP) devido a bradiarritmias e função ventricular sistólica ≥ 0,40. A randomização aleatória (VD vs VE) ocorreu antes do procedimento. Os desfechos primários do estudo foram: o sucesso, a segurança e a eficácia do procedimento proposto. Os desfechos secundários foram: a evolução clínica e alterações ecocardiográficas. Empregou-se os testes Qui-quadrado, Exato de Fisher e t de Student, com nível de significância de 5%. Resultados: De junho de 2012 a janeiro de 2014 foram incluídos 91 pacientes, sendo 36 no grupo VD e 55 no grupo VE. As características basais dos pacientes dos dois grupos foram similares. O implante de MP foi realizado com sucesso e sem nenhuma intercorrência em todos os pacientes do grupo VD. Dos 55 pacientes inicialmente alocados para o grupo VE, o implante do cabo-eletrodo em veias coronárias não foi possível em 20 (36,4%) pacientes. Dentre os 35 pacientes que permaneceram com o cabo-eletrodo no VE, a estimulação frênica foi a complicação mais frequente e foi detectada em 9 (25,7%) pacientes. Na fase de seguimento clínico, não houve hospitalizações por insuficiência cardíaca. Reduções superiores a 10% na fração de ejeção do VE foram observadas em 23,5% dos pacientes do grupo VD e em 20,6% dos pacientes do grupo VE (p = 0,767). A análise feita pelo Doppler tecidual mostrou que 91,2% dos indivíduos do grupo VD e 68,8% dos do grupo VE apresentaram dissincronia interventricular (p = 0,022). Conclusões: A taxa de sucesso do implante no VE foi baixa e a segurança do procedimento foi influenciada, principalmente, pela alta taxa de estimulação frênica no pós-operatório.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Pacemaker, Artificial/adverse effects , Bradycardia/therapy , Cardiac Pacing, Artificial/methods , Heart Ventricles/physiopathology , Stroke Volume , Bradycardia/physiopathology , Cardiac Pacing, Artificial/adverse effects , Single-Blind Method , Reproducibility of Results , Treatment Outcome , Prosthesis Implantation/methods , Heart Failure/etiology , Heart Failure/physiopathology
13.
In. Consolim-Colombo, Fernanda M; Saraiva, José Francisco Kerr; Izar, Maria Cristina de Oliveira. Tratado de Cardiologia: SOCESP / Cardiology Treaty: SOCESP. São Paulo, Manole, 4ª; 2019. p.350-355.
Monography in Portuguese | LILACS | ID: biblio-1009348
14.
ABC., imagem cardiovasc ; 31(4)Out.- Dez. 2018. ilus
Article in Portuguese | LILACS | ID: biblio-963978
15.
ABC., imagem cardiovasc ; 31(3)jul.-set. 2018. ilus, graf
Article in Portuguese | LILACS | ID: biblio-909374

ABSTRACT

A Sociedade Brasileira de Anestesiologia, pelo Núcleo Vida de Ecocardiografia Transesofágica Intraoperatória (ETTI/SBA) juntamente com o Departamento de Imagem Cardiovascular da Sociedade Brasileira de Cardiologia (DIC/SBC), fez uma força-tarefa para normatizar a feitura da ecocardiografia transesofágica intraoperatória para os anestesiologistas e ecocardiografistas brasileiros com base nas evidências científicas da Sociedade dos Anestesiologistas Cardiovasculares/Sociedade Americana de Ecocardiografia (SCA/ASE) e da Sociedade Brasileira de Cardiologia


Subject(s)
Humans , Anesthesiology/methods , Anesthesiology/standards , Echocardiography, Transesophageal/methods , Echocardiography, Transesophageal/standards , Aortic Valve , Brazil , Esophagus , Evidence-Informed Policy , Guidelines as Topic/standards , Heart , Heart Atria , Heart Ventricles , Hemodynamic Monitoring/methods , Mitral Valve , Probe , Pulmonary Artery , Thoracic Surgery/methods , Tricuspid Valve
17.
Rev. bras. anestesiol ; 68(1): 1-32, Jan.-Feb. 2018. tab, graf, ilus
Article in Portuguese | SES-SP, LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-897812

ABSTRACT

RESUMO A Sociedade Brasileira de Anestesiologia, pelo Núcleo Vida de Ecocardiografia Transe-sofágica Intraoperatória (ETTI/SBA) juntamente com o Departamento de Imagem Cardiovascularda Sociedade Brasileira de Cardiologia (DIC/SBC), fez uma forc ̧a-tarefa para normatizar afeitura da ecocardiografia transesofágica intraoperatória para os anestesiologistas e ecocar-diografistas brasileiros com base nas evidências científicas da Sociedade dos AnestesiologistasCardiovasculares/Sociedade Americana de Ecocardiografia (SCA/ASE) e da Sociedade Brasileirade Cardiologia.


ABSTRACT Through the Life Cycle of Intraoperative Transesophageal Echocardiography(ETTI/SBA) the Brazilian Society of Anesthesiology, together with the Department of Cardi-ovascular Image of the Brazilian Society of Cardiology (DIC/SBC), createded a task force tostandardize the use of intraoperative transesophageal echocardiography by Brazilian anesthesi-ologists and echocardiographers based on scientific evidence from the Society of CardiovascularAnesthesiologists/American Society of Echocardiography (SCA/ASE) and the Brazilian Society ofCardiology.


Subject(s)
Humans , Echocardiography, Transesophageal/standards , Heart/diagnostic imaging , Cardiac Surgical Procedures , Intraoperative Care , Echocardiography, Transesophageal/adverse effects , Echocardiography, Transesophageal/methods
18.
ABC., imagem cardiovasc ; 31(1): f:4-l:56, jan.-mar. 2018. ilus, tab, graf
Article in Portuguese | LILACS | ID: biblio-878730

ABSTRACT

Disfunção de prótese valvar cardíaca (PVC) é rara, porém é uma potencial ameaça à vida. Estabelecer o exato mecanismo da disfunção da PVC é desafiador, no entanto é essencial para determinar a estratégia terapêutica apropriada. Na prática clinica, uma abordagem abrangente que integra vários parâmetros de morfologia e função avaliados pelo eco transtorácico 2D/3D e transesofágico são fundamentais para detectar e quantificar a disfunção da PVC. A cinefluoroscopia, a tomografia computadorizada com multidectetores, a ressonância magnética cardíaca, e em menor escala, a imagem nuclear, são ferramentas complementares para o diagnóstico e abordagem das complicações das PVC. Este documento apresenta recomendações para o uso de imagem em multimodalidade para avaliação das PVCs


Subject(s)
Humans , Male , Female , Diagnostic Imaging , Echocardiography, Transesophageal/methods , Echocardiography/methods , Heart Valve Prosthesis/standards , Magnetic Resonance Spectroscopy/methods , Multidetector Computed Tomography/methods , Aortic Valve , Bioprosthesis , Diagnosis, Differential , Echocardiography, Doppler/methods , Echocardiography, Stress/methods , Hemodynamics , Mitral Valve , Nuclear Medicine/methods , Positron Emission Tomography Computed Tomography/methods , Prostheses and Implants , Evaluation Studies as Topic , Evaluation Studies as Topic , Stents , Stroke Volume , Thrombosis , Tomography, X-Ray Computed/methods , Tricuspid Valve
20.
Arq. bras. cardiol ; 109(3,supl.1): 1-104, Sept. 2017. tab, graf
Article in English | LILACS | ID: biblio-887936
SELECTION OF CITATIONS
SEARCH DETAIL