ABSTRACT
The analysis of ammonia nitrogen in real water samples is challenging due to matrix interferences and difficulties for rapid on-site analysis.On the basis of the standard method,i.e.water quality-determination of ammonia nitrogen-salicylic acid spectrophotometry(HJ 536-2009),a simple device for online detecting ammonia nitrogen was developed using a sequential injection analysis(SIA)system in this work.The ammonia nitrogen transformation system,color reaction system,and detection system were built in compatible with the SIA system,respectively.In particular,the detection system was assembled by employing light-emitting diode as the light source,photodiode as the detector,and polyvinylchloride tube as the cuvette,thus significantly reducing the volume,energy consumption and fabricating cost of the detection system.As a result,the accurate analysis of ammonia nitrogen in complex water samples was achieved.A quantitative detection of ammonia nitrogen in water sample was obtained in 12 min,along with linear range extending to 1000 μmol/L,precisions(Relative standard deviation,RSD)of 4.3%(C=10 μmol/L,n=7)and 4.2%(C=500 μmol/L,n=7),and limit of detection(LOD)of 0.65 μmol/L(S/N=3,n=7).The results of interfering experiments showed that the detection of ammonia nitrogen by the developed device was not interfered by the common coexisting ions and components,therefore the environmental water could be directly analyzed,such as reservoir water,domestic sewage,sea water and leachate of waste landfill.The analytical results were consistent with those obtained by the environmental protection standard method(Water quality determination of ammonia nitrogen-salicylic acid spectrophotometry,HJ 536-2009).In addition,the spiking recoveries were in the range of 92.3%-98.1%,further confirming the accuracy and practicality of the developed device.
ABSTRACT
OBJECTIVE@#To compare the biomechanical stability of different fixation methods for anterior ring injury of unstable pelvic fractures, and to provide reference for clinical treatment.@*METHODS@#An unstable pelvic fracture model (Tile C) with one side of the sacroiliac joint dislocation and the pubic rami fracture was constructed via three-dimensional finite element analysis. Five different fixation methods were used in the front, and the rear was fixed with sacroiliac screws. The von Mises stress and strain distributions of different combinations of fixation methods were analyzed under mimicking standing conditions.@*RESULTS@#After being loaded with 500 N vertically, the maximum stress in the anterior fracture was 3.56 MPa in anterior pelvic external fixation (AEF) group, the total displacement and the vertical displacement of the Y axis at the sacroiliac joint and the fracture were not more than 1.5 mm. The maximum stress at fixation, the front of the fracture and sacroiliac joints in the anterior pelvic subcutaneous approach(APA) group and AEF, was significantly higher than anterior modified Stoppa approach(ASA) group, anterior pelvic Ilioinguinal approach (AIA) group, and canulated screw fixation(CSF) group. The total displacement and the vertical displacement of the Y axis at the sacroiliac joint and the fracture in APA group and AEF group were also greater than the other three groups.@*CONCLUSIONS@#Anterior ring injury of unstable pelvic fractures can be significantly improved after the fixation of the implants in the five combined methods. However, overall biomechanical properties of ASA, AIA and CSF group are superior to APA and AEF group.
Subject(s)
Humans , Bone Screws , Finite Element Analysis , Fracture Fixation, Internal , Fractures, Bone , Pelvic BonesABSTRACT
OBJECTIVE@#To investigate the effect of perioperative dexamethasone on nausea, vomiting and pain after unilateral total knee arthroplasty and to evaluate its safety.@*METHODS@#From February 2014 to June 2016, 100 patients with unilateral advanced osteoarthritis treated by total knee arthroplasty were divided into two groups: 50 patients in dexamethasone group including 27 males and 23 females, aged (72.30±7.02) years, were given intravenous drip of dexamethasone 10 mg before operation; 50 patients in saline group, including 26 males and 24 females, aged (71.30±6.08) years, were given the same amount of saline at the corresponding time. The VAS scores of pain at rest and at 45 degrees of knee flexion were recorded at 2, 4, 6, 8, 12, 24, 36 and 48 h after operation. Vomiting, antiemetic drugs and opioids were recorded at 0 to 24 h and 24 to 48 h after operation. The side effects and complications were recorded.@*RESULTS@#All the 100 patients were followed up for an average of 14.5 months. VAS score of pain at rest in dexamethasone group was lower than that in saline group at 8, 24 and 48 h after operation (<0.05); VAS score of dexamethasone group at 45 degrees after knee flexion was lower than that of saline group at 8 and 48 h after operation(<0.05); VAS score of dexamethasone group at rest and 45 degrees after knee flexion was lower than that of saline group(<0.05). The dosage of opioids and total opioids in dexamethasone group was lower than that in saline group at 0 to 24 h, 24 to 48 h after operation (<0.05). The proportion of nausea and vomiting occurred at 0 to 24 h and 24 to 48 h after operation, and the proportion of antiemetic required at 0 to 24 h after operation had statistical significance between two groups(<0.05). The total antiemetic dosage of dexamethasone group was less than that of saline group(<0.05). As of the last follow-up, no complications such as infection, gastrointestinal ulcer and bleeding occurred in the two groups.@*CONCLUSIONS@#Preoperative systemic application of dexamethasone can effectively reduce pain and nausea and vomiting after TKA without increasing postoperative complications.
Subject(s)
Aged , Female , Humans , Male , Arthroplasty, Replacement, Knee , Dexamethasone , Nausea , Pain, Postoperative , VomitingABSTRACT
@#:【Objective】To provide basic experimental basis for quantitative detection and analysis of antibiotic susceptibilityandheteroresistancein Mycobacterium tuberculosis byflowcytometry,weinvestigatedtheperformanceof propidiumiodide(PI)and6-carboxyfluoresceindiacetae(6-cFDA)inidentifyingdeadorlivingMycobacterium tubercu⁃ losis.【Methods】PIand6-cFDAwereusedtostain10strainsofpureculturedliving Mycobacterium tuberculosis suspen⁃ sion with turbidity of 1 McClell and the corresponding suspension with turbidity of 1 McClell heated at 85℃ for 30 minutes,respectively.Themeanfluorescenceintensity(MFI)wasmeasuredbyflowcytometry.TheMFIboundaryvalue fordistinguishingdeadandlivingMycobacterium tuberculosisweredeterminedaccordingtoreceiveroperatingcharacteristic (ROC)curves.Thesameexperimentswerecarriedoutwithother10strainsofliving Mycobacterium tuberculosis suspen⁃sionand10dead Mycobacterium tuberculosis suspension,andtheMFIthresholdwasusedtodeterminetheviabilityof bacteria.【Results】(1)IntheexperimentofdeterminingMFIboundaryvalue,theMFIof10strainsofdeadbacteria suspensionstainedwithPIwasnon-normaldistribution,themedianvaluewas2459,andtheMFIof10strainsofliving bacteriasuspensionstainedwithPIwasnormaldistribution,themeanvaluewas426±180.TheMFIboundaryvalueof deadbacteriastainedwithPIwas1329.TheMFIof10strainsofdeadbacteriaand10strainsoflivingbacteriasuspen⁃ sionstainedwith6-cFDAwasnormaldistribution,andthemeanvaluewas49±4and7144±4511,respectively.The MFIthresholdof6-cFDAstainingforlivingbacteriawas1021.(2)TheMFIthresholdsforidentifyingdeadbacteriaby PIstainingandtheMFIthresholdsforidentifyinglivingbacteriaby6-cFDAstainingwereusedtodetect10otherliving bacterialsuspensionsand10deadbacterialsuspensions.Theaccuracy,sensitivity,specificity,Yondeindex,positive predictivevalueandnegativepredictivevaluewere95%and100%,1.00and1.00,0.90and1.00,0.90and1.00,0.91 and1.00,1.00and1.00,respectively.【Conclusions】PIstainingcandetectdeadMycobacterium tuberculosisand6-cFDA stainingcandetectliving Mycobacterium tuberculosis.Identificationof Mycobacterium tuberculosis activitybasedonPIand 6-cFDAstainingwillhavebroadapplicationprospects.
ABSTRACT
Along with the increase of clinical application, the safety of traditional Chinese medicine gained more and more attentions. In particular, the safety evaluation of Chinese medical injections has become a mandatory task should be completed by pharmaceutical companies under the supervision of China Food and Drug Administration(CFDA). Due to the weak foundation of previous studies, the safety issues of Chinese medical injections have not been fully understood, and lack of scientific and rational risk management programs. Clinical safety centralized monitoring(CSCM) is an important method for post-market safety evaluation of Chinese medicine. Due to the lack of appropriate norms and procedures, the quality of similar research is uneven, and the results vary. Combined with practical experience with experts' suggestions, we developed this expert consensus on the design and implementation of CSCM from three stages (design, implementation and report) with 20 technical points, which will provide technical support for future CSCM studies.
ABSTRACT
<p><b>OBJECTIVE</b>To investigate feasibility and curative effect of superselective arterial embolization for the treatment of massive haemorrhage from pelvic fracture.</p><p><b>METHODS</b>From March 2008 to February 2016, clinical data of 65 patients with massive haemorrhage from pelvic fracture were collected and analyzed, and patients were divided into non-embolic and embolic group according to whether perform vascular thrombosis. Thirty-three patients were in non-embolic group including 26 males and 7 females aged from 21 to 64 years old with an average of(39.2±5.7) years old, the time from injury to operation ranged from 1.1 to 4.8 h with an average of (2.2±0.4) h; 12 cases were type B and 21 cases were type C according to AO/Tile classification; injury severity score (ISS) ranged from 25 to 42 with an average of (37.7±7.5); shock index score ranged from 1.7 to 2.4 with an average of 2.1±0.3; treated with blood transfusion and fluid infusion. Thirty-two patients in embolic group, including 25 males and 7 females aged from 22 to 65 years old with an average of(38.1±4.5) years old; the time from injury to operation ranged from 1.2 to 4.8 h with an average of (2.1± 0.5) h; 14 cases were type B and 18 cases were type C according to AO/Tile classification; ISS ranged from 26 to 43 with an average of 38.9±4.5; shock index score ranged from 1.6 to 2.4 with an average of 2.2±0.2; treated by blood transfusion and fluid infusion with superselective arterial embolization. Blood transfusion volume, fluid infusion volume, shock correction time and survival rate were observed and compared, effective rate of hemostasis and postoperative complications were compared.</p><p><b>RESULTS</b>Thirty-seven artery were injured in embolic group, hemostasis were controlled at 3 h after operation, and hemodynamics turned to stable. There were significant difference in blood transfusion volume, fluid infusion volume, shock correction time between non-embolic and embolic group, and embolic group performed better. Survival rate in embolic group was also better than that of non-embolic group, and had significant difference. While there was obvious differences in complications(χ²=4.03,=0.045).</p><p><b>CONCLUSIONS</b>Superselective arterial embolization for massive haemorrhage from pelvic fracture could effective hemostasis, reduce blood transfusion and fluid infusion volume and occurrence rate of shock, moreover improve survival rate and deserves promotion.</p>
ABSTRACT
<p><b>OBJECTIVE</b>To study clinical effects of a new internal fixation by using a cable through the bone and Kirschner with a hole in the tail, for the treatment of patellar fractures.</p><p><b>METHODS</b>From May 2012 to July 2013, thirty-four patients with patellar fractures were treated with cable through the bone and Kirschner with a hole in the tail. All the patients had close fracture,including 12 transverse fractures and 22 comminuted fractures. There were 18 males and 16 females, ranging in age from 26 to 81 years old, with an average of (46.0 ± 3.0) years old. After open reduction, two appropriate length of Kirschner with a hole in the tail were driven into the patella as perpendicular to the fracture line or the major fragments as possible. A transverse bone tunnel was then drilled with a Kirschner at one side of the patella. Then the cable, which was successively pulled through the bone tunnel and the hole of Kirschner, was crossed in a figure-eight over the anterior of the patella, tightened and fixated by special instruments. The Kirschner was clipped off on the edge of the hole. If it was a comminuted fracture, another cable was used to fasten the patella with cerclage. Postoperative evaluation was based on Bostman.</p><p><b>RESULTS</b>All the patients were followed up, and the duration ranged from 12 to 26 months, with a mean of (16.0 ± 2.0) months. Fractures healed in all the cases without such complications as infection, loosening of Kirschner and cable loop, and skin irritation. According to the Böstman score system, 33 cases got an excellent result, and 1 good.</p><p><b>CONCLUSION</b>The cable through the bone and Kirschner with a hole in the tail is a simple, stable and effective method for the treatment of patellar fractures, especially the transverse fractures, with earlier knee exercise and fewer complications.</p>
Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Bone Wires , Follow-Up Studies , Fracture Fixation, Internal , Methods , Fractures, Bone , General Surgery , Patella , Wounds and Injuries , General Surgery , Treatment OutcomeABSTRACT
As a new type of carbon nanomaterials, fluorescent carbon dots (fluorescent CDs) have many advantages when compared with the traditional fluorescent probes. They are photoluminescence stable and resistance to photo bleaching. Moreover, they are excellent in biocompatibility, low-toxic and easy to modify. All these above make them a promising optical image material as a probe in optical image. This article reviews structure, the common carbon sources, the preparation methods, and the light-emitting principles of the carbon dots. We also introduce the research progress of fluorescent carbon dots in biomedicine, and the problems need to be resolved in the study of fluorescent CDs.
Subject(s)
Carbon , Chemistry , Fluorescent Dyes , Chemistry , Nanostructures , Chemistry , Quantum Dots , ChemistryABSTRACT
<p><b>OBJECTIVE</b>To explore the clinical effects of Stoppa approach and posterior percutaneous plate in treating type C pelvic fracture.</p><p><b>METHODS</b>From June 2009 to July 2011,16 patients with type C pelvic fracture were treated with reconstruction plate fixation in Stoppa approach for anterior lesions combined with posterior percutaneous plate fixation for posterior lesions.There were 11 males and 5 females,with an average age of 38.8 years (ranged, 22 to 59 years). According to the Tile classification,10 cases belonged to C1,4 belonged to C2,2 belonged to C3. Tometta and Majeed score standards were used to evaluate clinical results.</p><p><b>RESULTS</b>Sixteen patients were followed up from 4 to 13 months with an average of 7.3 months. Operative time was from 80 to 140 min with an average of 100 min;blood loss volume was from 200 to 500 ml with an average of 280 ml; and the healing time of fracture was from 12 to 16 months with an average of 14 months. According to the Tometta score classification, 9 cases got excellent results, 6 good, 1 fair. According to the Majeed score classification, 9 cases obtained excellent results, 5 good, 2 fair.</p><p><b>CONCLUSION</b>Reconstruction plate fixation in Stoppa approach for anterior lesions combined with posterior percutaneous plate fixation for posterior lesions is an ideal minimally invasive operation in treaing type C pelvic fracture. It can early exercise and has the advandages of small trauma, safe operaton,less complication, stable fixation.</p>
Subject(s)
Adult , Female , Humans , Male , Middle Aged , Bone Plates , Fracture Fixation, Internal , Methods , Fractures, Bone , General Surgery , Pelvic Bones , Wounds and Injuries , General SurgeryABSTRACT
<p><b>OBJECTIVE</b>To compare the curative effects of newly suture anchors and traditional steel wire for the reconstruction of near distal tendo achillis rupture.</p><p><b>METHODS</b>The clinical data of 56 patients with near distal tendo achillis rupture from June 2007 to February 2011 were retrospectively analyzed. Among 31 patients receiving reconstruction by suture anchors, 22 patients were male and 9 patients were female, with a mean age of 35.5 years (ranging from 16 to 52 years ). Among 25 patients treated with traditional steel wire, 19 patients were male and 6 patients were female, with a mean age of 37.6 years (ranging from 22 to 53 years). The different rehabilitation was conducted for every patient at different times after operation. The position of suture anchor and steel wire were recorded. The clinical data such as operative time, complications of the surgery and the function of stendo achillis were analyzed. The healing of stendo achillis and functional recovery were assessed by Arner-Lindholm standard.</p><p><b>RESULTS</b>All the patients were followed up with an average during of 24.2 months. There were no intraoperative injuries on blood vessels, nerve and tendon. The average operative time and postoperative complications of suture anchors were lower than there of the traditional steel wire (t = 8.75, P = 0.00; Chi2 = 5.42, P = 0.02). The functional recovery of tendo achillis repaired by suture anchors was better than that in the group of traditional steel wire (Chi2 = 7.65, P = 0.02).</p><p><b>CONCLUSION</b>Compared to the traditional steel wire, suture anchor demonstrate the superior performance on repairing rupture of the near distal tendo achillis, which is a reliable and effective treatment methods.</p>
Subject(s)
Adolescent , Adult , Female , Humans , Male , Middle Aged , Achilles Tendon , Diagnostic Imaging , Wounds and Injuries , General Surgery , Bone Wires , Case-Control Studies , Radiography , Plastic Surgery Procedures , Methods , Retrospective Studies , Rupture , General Surgery , Suture AnchorsABSTRACT
Objective To explore the influence of positioning of the femoral tunnel for medial patellofemoral ligamentre (MPFL)construction on the isometric characteristics of grafts.Method Knee specimens from ten fresh frozen cadavers were used. The attachment of medial patellofemoral ligament was observed. The distance between points from the adductor tubercle, the medial femoral epicondyle, and proximal, distal and central point of the MPFL’s femoral attachment site respectively to the middle point of its patellar attachment site were measured. Changes in length were recorded while the knee was measured by angles of knee flexion (0°, 30°, 60°, 90°, and 120°). Results The length changes in every point were compared. All of the maximal length changes of its adductor tubercle: proximal points were not greater than 3 mm. There was no significant difference between the length changes of adductor tubercle and proximal points(P>0.05). Conclusions The position of the femoral turnel for MPFL reconstruction should be located as follows: MPFL should be at the middle point of upper edge of femoral attachment site (proximal point), and the point can appropriately be shifted to adductor tubercle.
ABSTRACT
<p><b>OBJECTIVE</b>To investigate the techniques and curative effects of transcatheter artery embolization (TAE) for massive bleeding due to pelvic fractures.</p><p><b>METHODS</b>The clinical data of 92 patients with haemorrhage due to pelvic fractures from March 1998 to February 2008 were retrospectively analyzed. Among 53 patients treated conservatively such as massive transfusion and fluid infusion in the control group, 43 patients were male and 10 patients were female, ranging in age from 27 to 61 years, averaged (37.2 +/- 5.7) years. Among 39 patients who were hemodynamically unstable or had evidences of ongoing hemorrhage required TAE, 26 patients were male and 13 patients were female, ranging in age from 26 to 62 years, with a mean age of (35.3 +/- 9.5) years. The clinical date such as blood or fluid transfusion volume, shock redress time and survival rate were compared between the two groups. The hemostatic efficiency and complications of the surgery were also analyzed.</p><p><b>RESULTS</b>The average hemostasis time of TAE group was 2 hours. There were no intraoperative injuries of blood vessels, nerve or vital organs. Three patients had lower limbs numbness and 5 patients had gluteal skin redness after the operation. The blood transfusion or fluid infusion volume, shock redress time and survival rate were all significantly better than those in the conservative group.</p><p><b>CONCLUSIONS</b>TAE is an early,rapid and effective method in controlling haemorrhage due to pelvic fractures.</p>
Subject(s)
Adult , Female , Humans , Male , Middle Aged , Case-Control Studies , Embolization, Therapeutic , Methods , Fractures, Bone , Therapeutics , Hemorrhage , Therapeutics , Pelvic Bones , Wounds and InjuriesABSTRACT
<p><b>OBJECTIVE</b>To investigate the techniques and therapeutic effects of suture anchors for the reconstruction of distal tendo achillis rupture.</p><p><b>METHODS</b>The clinical data of 16 patients of distal tendo achillis rupture repaired with suture anchors from June 2005 to August 2008 were retrospectively analyzed. Among them, there were 13 males and 3 females with a mean age of 33.5 years (ranged from 17 to 46 years). The postoperative rehabilitation was conducted for every patient. The operation time, position of suture anchor and complications of the surgery were analyzed. The healing of stendo achillis and functional recovery were assessed by Arner-Lindholm standard.</p><p><b>RESULTS</b>All the patients were followed up for an average of 13.2 months. There were no complications of foreign-body reaction or re-rupture. The average operation time was 35.5 minute. There was no intraoperative injuries of blood vessels, nerves or tendons. A total of 19 suture anchors were used, and only 1 anchor was displaced. The functional recovery of tendo achillis was rated as excellent in 13 cases,good in 2 cases, bad in 1 case. All patients were satisfied with the effects on their current work and life. And no displacement of anchors was found in radiographic films.</p><p><b>CONCLUSION</b>Repairing of the distal tendo achillis rupture with suture anchors can make operation simple and quick, rigid fixation, less complications, and provide good therapeutic effects.</p>
Subject(s)
Adolescent , Adult , Female , Humans , Male , Middle Aged , Young Adult , Foreign-Body Reaction , Plastic Surgery Procedures , Methods , Retrospective Studies , Suture Anchors , Tendon Injuries , Allergy and Immunology , General Surgery , Tenodesis , Methods , Treatment OutcomeABSTRACT
<p><b>OBJECTIVE</b>To explore the effect of improved EPSTR on prevention of dislocation after total hip arthroplasty.</p><p><b>METHODS</b>From January 2006 to May 2007, the posterior structures were repaired using improved EPSTR in 85 cases (87 hips) of total hip arthroplasty, which involved 39 males and 46 females, with an average age of 69.5 years (range, from 62 to 85 years). Fifty-eight cases were of fresh femoral neck fracture, 25 cases were of aseptic necrosis of femoral head, 3 cases were of osteoarthritis, 1 case was of a internal fixation failure of femoral intertrochanteric fracture.</p><p><b>RESULTS</b>All 85 cases were followed up for 8-24 months (average 15 months). None of these 85 patients had posterior dislocation, external rotation contracture and greater trochanter fracture. The Harris score at the 6th month postoperatively was 89.2 +/- 4.5.</p><p><b>CONCLUSION</b>Improved EPSTR is an effective, simple and timesaving method in prevention of dislocation after total hip arthroplasty, it has clinical application value.</p>
Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Arthroplasty, Replacement, Hip , Femoral Neck Fractures , General Surgery , Femur Head Necrosis , General Surgery , Hip Dislocation , Hip Prosthesis , Osteoarthritis , General Surgery , Prosthesis Failure , Treatment OutcomeABSTRACT
Objective To explore the isometry of grafts in PCL(posterior cruciate ligament)double-bundle re-construction under femoral tunnel shifting condition.Method Knee specimens from ten fresh frozen cadavers were used.PCL were divided into anterolateral bundles(ALB)and posteromedial bundles(PMB)to the inser-tion footorint.The anterior,postedor,proximal,distal and central points of the two bundles'femoral attachment site were respectivelyanchored to the middle of the PCL's tibial attachment site by the trial wires.Changes in length of the intra-articular part of the wires were recorded while the knee was flexed from 0°to 120°.Result The length changes in every point were compared.All of the maximal length changes of ALB's proximal,pos-todor points and PMB's proximal points were not greater than 2mm.No significant difference between the length changes of ALB's proximal point and posterior(P=0.864>0.05)was found.Conclusions The femo-ral tunnel for the PCL double-bundle reconstruction should be located as follows:ALB should be at the middle point of upper edge of femoral attachment site(proximal point),while PIVIB at the middle point of femoral attachment site(proximal point).
ABSTRACT
Objective To explore the isometry of grafts in PCL(posterior cruciate ligament)double-bundle re-construction under femoral tunnel shifting condition.Method Knee specimens from ten fresh frozen cadavers were used.PCL were divided into anterolateral bundles(ALB)and posteromedial bundles(PMB)to the inser-tion footorint.The anterior,postedor,proximal,distal and central points of the two bundles'femoral attachment site were respectivelyanchored to the middle of the PCL's tibial attachment site by the trial wires.Changes in length of the intra-articular part of the wires were recorded while the knee was flexed from 0°to 120°.Result The length changes in every point were compared.All of the maximal length changes of ALB's proximal,pos-todor points and PMB's proximal points were not greater than 2mm.No significant difference between the length changes of ALB's proximal point and posterior(P=0.864>0.05)was found.Conclusions The femo-ral tunnel for the PCL double-bundle reconstruction should be located as follows:ALB should be at the middle point of upper edge of femoral attachment site(proximal point),while PIVIB at the middle point of femoral attachment site(proximal point).
ABSTRACT
<p><b>OBJECTIVE</b>To explore the role of reconstruction of the posterior capsule and external rotators in prevention of postoperative dislocation in total hip arthroplasty revision following the posterolateral approach.</p><p><b>METHODS</b>Forty-five patients (47 hips) with the mean age of 65 years (55 to 78 years)of failed total hip arthroplasty were revised following the posterolateral approach. Posterior capsule was sutured to the anterosuperior portion of the capsule from where it had been detached, and the external rotators were then reattached to the soft tissue at the tip of the greater trochanter using 1.0 silk suture in surgery. The dislocation rate and risk factors were reviewed retrospectively to determine if closing the posterior capsule resulted in fewer dislocations. The femoral prosthesis and acetabular prosthesis were revised in 29 patients (31 hips), the liner was exchanged in 5 patients (5 hips), and the acetabular prosthesis or femoral components were revised in 10 patients (10 hips) and one patient (one hip) respectively. The procedure was the patient's first revision in 29 patients (30 hips), the second revision in 15 patients (16 hips), and the third revision in one patient(one hip). Radiographic evaluation included lower limb discrepancy, acetabular phase, femoral offset, anteversion angle, prosthetic loosening before and after revision. Function evaluation based on Harris score system.</p><p><b>RESULTS</b>All patients were followed up with an average of 2.7 years. None of the patients sustained dislocation or infection, except one patient felt the anterior instability but without dislocation, X-ray revealed the acetabular component was in excessively anteversion. Lower leg discrepancy, acetabular abduction, anteversion femoral offest and collodiaphyseal angle were restored to normal level after operation on the basis of X-ray. One of the acetabular components and one of the femoral components were loose without dislocation. The Harris hip score improved from (49.13 +/- 15.53) points preoperatively to (83.59 +/- 6.93) points at the final follow-up (P < 0.05). According to Harris functional evaluation, 36 hip got an excellent result, 5 good, 5 fair and 1 bad.</p><p><b>CONCLUSION</b>The historically high dislocation rate with the posterolateral approach for total hip arthroplasty revision can be reduced by careful soft tissue balancing,correction of implant alignment, meticulously closure of the posterior capsule, and reattaching the external rotators.</p>
Subject(s)
Aged , Female , Humans , Male , Middle Aged , Arthroplasty, Replacement, Hip , Follow-Up Studies , Hip , Diagnostic Imaging , General Surgery , Hip Dislocation , Hip Prosthesis , Postoperative Complications , Prosthesis Failure , Radiography , Retrospective StudiesABSTRACT
This study was aimed to explore the expression of MIP-1alpha, MCP-1 and their receptors CCR-1, CCR-2 in bcr/abl fusion gene positive CML cells, and to study the effects of P210(bcr/abl) fusion protein tyrosine kinase on expression of MIP-1alpha, MCP-1 and their receptors CCR-1, CCR-2 mRNAs in chronic myeloid leukemia cells. The expression levels of MIP-1alpha, MCP-1 and their receptors CCR-1, CCR-2 mRNA were detected by semi-quantitative RT-PCR in bcr/abl negative cells, bcr/abl positive cells, and P210(bcr/abl)-Rb-C-Box positive cells. The results showed that MIP-1alpha and CCR-1 mRNAs were expressed in bcr/abl negative cells, but not in positive cells. Both MCP-1 and CCR-2 mRNA cannot be detected in both bcr/abl positive and negative cells. After inhibiting P210(bcr/abl) tyrosine kinase activity by Rb-C-Box, expressions of MIP-1alpha and CCR-1 mRNAs were restored to normal (similar to P210(bcr/abl) negative cells). It is concluded that P210(bcr/abl) fusion protein inhibits the expression of MIP-1alpha and CCR-1 in chronic myeloid leukemia cells, but does not inhibit MCP-1 and CCR-2 mRNA expressions in these leukemia cells.
Subject(s)
Humans , Chemokine CCL2 , Genetics , Chemokine CCL3 , Chemokine CCL4 , Leukemia, Myelogenous, Chronic, BCR-ABL Positive , Metabolism , Macrophage Inflammatory Proteins , Genetics , Receptors, CCR1 , Receptors, CCR2 , Receptors, Chemokine , Genetics , Tumor Cells, CulturedABSTRACT
<p><b>OBJECTIVES</b>To explore the effects of p210 bcr/abl fusion gene on expression of beta1 integrin and L-selectin mRNAs in mouse chronic myeloid leukemia (CML) cells.</p><p><b>METHODS</b>Comparisons of beta1 integrin and L-selectin mRNA levels among p210 bcr/abl negative, p210 bcr/abl positive, and p210 bcr/abl-Rb-C-Box positive cells were undertaken by quantity RT-PCR.</p><p><b>RESULTS</b>In p210 bcr/abl positive cells, L-selectin mRNA level was decreased, but beta1 integrin mRNA expression had no change as compared to those in p210 bcr/abl negative cells. When inhibition of bcr-abl tyrosine kinase activity by Rb-C-Box, the L-selectin mRNA expression restored to normal (similar to p210 bcr/abl negative cells).</p><p><b>CONCLUSION</b>p210 bcr/abl oncoprotein inhibits expression of L-selectin mRNA, but not of beta1 integrin mRNA.</p>