ABSTRACT
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Subject(s)
Pregnancy , Child , Humans , Female , Glycated Hemoglobin , Cohort Studies , Diabetes Mellitus/diagnosis , Sensitivity and Specificity , ROC CurveABSTRACT
Objective To understand the distribution and antimicrobial resistance changes of bacteria isolated from pleural and peritoneal effusion in Hunan Province,and provide reference for correct clinical diagnosis and rational antimicrobial use.Methods Data reported by member units of Hunan Provincial Antimicrobial Resistance Survei-llance System from 2012 to 2021 were collected.Bacteria antimicrobial resistance surveillance method was imple-mented according to technical scheme of China Antimicrobial Resistance Surveillance System(CARSS),and WHO-NET 5.6 software was used to analyze the data of bacteria isolated from pleural and peritoneal effusion as well as antimicrobial susceptibility testing results.Results From 2012 to 2021,a total of 28 934 bacterial strains were iso-lated from specimens of pleural and peritoneal effusions from member units of Hunan Provincial Antimicrobial Re-sistance Surveillance System,with 5 752 strains from pleural effusion and 23 182 from peritoneal effusion.The top five bacteria isolated from pleural effusion were Escherichia coli(n=907,15.8%),Staphylococcus aureus(n=535,9.3%),Klebsiella pneumoniae(n=369,6.4%),Staphylococcus epidermidis(n=452,7.9%),and Staphy-lococcus haemolyticus(n=285,5.0%).The detection rate of methicillin-resistant Staphylococcus aureus(MR-SA)from pleural effusion was 24.3%-39.2%,and that of methicillin-resistant coagulase negative Staphylococcus(MRCNS)was 58.8%-77.1%.The top five bacteria isolated from peritoneal effusion were Escherichia coli(n=8 264,35.6%),Klebsiella pneumoniae(n=2 074,9.0%),Enterococcus faecium(n=1 458,6.3%),Staphylo-coccus epidermidis(n=1 383,6.0%),and Pseudomonas aeruginosa(n=1 152,5.0%).The detection rate of MRSA from peritoneal effusion was 22.1%-52.4%,which presented a decreasing trend(P=0.004).The detec-tion rate of MRCNS was 60.4%-79.4%.The resistance rates of Enterobacterales from peritoneal effusion to ce-fazolin,cefuroxime,ceftriaxone and cefepime all showed decreasing trends(all P<0.05).Vancomycin-,linezo-lid-,and teicoplanin-resistant Staphylococcus strains were not found in pleural and peritoneal effusions.The resis-tance rates of Enterococcus faecium to most tested antimicrobial agents were higher than those of Enterococcus fae-calis.The resistance rates of Enterobacterales to imipenem and meropenem were ≤8.5%.The resistance rates of non-fermentative Gram-negative bacilli to imipenem and meropenem were ≤43.3%.Conclusion The data structure of Hunan Antimicrobial Resistance Surveillance System for pleural and peritoneal effusions from 2012 to 2021 is relatively complete.The constituent and antimicrobial susceptibility of isolated pathogenic bacteria vary in different years.
ABSTRACT
<p><b>OBJECTIVE</b>To compare the serum levels of low density lipoprotein cholesterol in Kazaks and Mongolians from Xinjiang pastoral area.</p><p><b>METHODS</b>A randomized cluster sampling was performed to obtain a representative sample of population in Xinjiang Hefeng pastoral area. Blood was taken from 632 individuals aged 30 and older for measurements of total cholesterol (TC), triglyceride (TG), high density lipoprotein cholesterol (HDL-C) by automatic biochemical analyzer. The serum levels of low density lipoprotein cholesterol (LDL-C) was calculated according to the formula.</p><p><b>RESULTS</b>The mean serum level of LDL-C was significantly higher in Kazaks [(3.68 +/- 1.16) mmol/L] than that in Mongolians [(3.29 +/- 1.23) mmol/L, P < 0.001]. The serum levels of LDL-C in Kazaks were significantly associated with mean artery pressure. The serum levels of LDL-C in Mongolians were significantly associated with body mass index.</p><p><b>CONCLUSION</b>The serum levels of LDL-C were higher in Kazaks compared that in Mongolians in Xinjiang pastoral area.</p>