ABSTRACT
Objective To study the relationship among rs505802 in SLC22A12,rs6855911,rs737267,rs12498742, rs7442295, rs734553, rs16890979 in SLC2A9 genetic polymorphisms and hypouricemia in Ningxia.Methods 6 056 subjects were collected by multistage,stratified random cluster sampling method in October and November in 2011 in Ningxia Hui autonomous region, 98 subjects with hypouricemia were selected.According to gender and age,84 controls were selected.Physical examination and laboratory biochemical index test were conducted for the study population.T test was used to compare general clinical data and biochemical indexs between two groups. SNPs were detected by Sequenom Mass ARRAY technology.By x2test,we compared the frequencies of the geno-type and allele in each group.Samples representativeness was confirmed through the Hardy-Weinberg inspection. Results The levels of TC, LDLC, and Cr in the patients were lower than those in the control group(P<0.05). There were significant differences in the distribution of A,G allele frequencies of SLC2A9 gene rs7442295 between two groups.The risk of hypouricemia in patients with A/A genotype was lower than that of A/G genotype(Pc<0.05),indicating that A>G mutation was associated with hypouricemia.Conclusions Polymorphisms of SLC2A9 gene rs7442295 are significantly correlated with hyporuricemia in Ningxia.
ABSTRACT
Objective To evaluate the analytical performance of four lipoprotein associated phospholipase A2(Lp-PLA2)activity reagents on Beckman AU5800 automatic biochemical analyzer. Methods The remaining serum samples of 214 patients and 140 apparently healthy individuals were collected from March to July 2017 in Peking Union Medical College Hospital.These samples were used for method comparison and reference interval evaluation.According to the guidelines of EP15-A,EP6-A,EP-17 and EP7-P from Clinical and Laboratory Standards Institute(CLSI)standards,the precision, linearity, sensitivity and common interferences(e.g free bilirubin, conjunct bilirubin, hemoglobin and chyle)were assessed.According to EP9-A2,method comparisons of differents regents(Evermed,DiaSys,Hengxiao and Zhongyuan were labeled as A,B,C and D,respectively)were conducted and the differences were estimated at medical decision levels(328U/L,391U/L and 485U/L).Results The precision of four reagents were acceptable.The repeatability(CV%)of A to D were 0.5%-1.7%, 0.7%-3.0%, 0.9%-2.0% and 0.5%-3.3%,respectively.The reproducibility(CV%)were 0.7%-2.9%, 1.4%-3.2%, 1.3%-1.9%and 0.8%-4.1%,respectively.Both of those achievedlaboratory defined quality objective(<5%).The linearity of A to D were 44 -1 992 U/L,39 -1 798 U/L,13 -540 U/L and 75-1 717U/L,respectively.The regression coefficient R2 was between 0.997 and 1.000, and the correlation coefficient(r)was between 0.998 and 1.000.The interference of chyle were acceptable among these four reagents andmet the manufacturer′s requirementsor clinical needs.In a low level of Lp-PLA2,bilirubin had an obvious interferenceonreagent C;B and C were negatively affected when the hemoglobin was 4.5 g/L; and D was positively affected when the hemoglobin was 2.45 g/L.The regression coefficients R2 of A,C,D compared with B were between 0.978 and 0.995,and the correlation coefficients(r)were between 0.989 and 0.998. The expected differences at medical decision levels ranged from -240 U/L to 113 U/L.For A to D,the Lp-PLA2 activity results of 131(93.6%), 140(100%), 82(58.6%), and 128(91.4%)cases were analysed within the manufacturer′s claimed reference intervals.Conclusion The precision and linearity of the four Lp-PLA2 activity detection reagents used in automatic biochemical analyzer are good, but the anti-interference ability needs to be improved.