Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Article in Chinese | WPRIM | ID: wpr-932590

ABSTRACT

Objective:To compare the dose and image quality of selected photon shield (SPS) technique, organ-based tube current modulation (OBTCM) technique and the combination of these two techniques for reducing the organ dose in head CT examination for infants.Methods:Two anthropomorphic head phantoms (CIRS 1-yr-old and 5-yr-old) were scanned by using Reference mode, Reference + OBTCM mode, SPS mode and SPS + OBTCM mode, respectively. Radiation doses to the lens of the eye, the anterior of the brain, the posterior of the brain, noise level and CNR of orbit and brain in different phantoms were measured and compared by using different scanning modes.Results:Compared with Reference mode, the doses to the lens of the eye in 1-yr-old and 5-yr-old phantom decreased by (21.89 ± 0.01)% and (28.33 ± 0.34)%, respectively. In SPS mode, the reduction in doses to the lens of the eye in 1-yr-old and 5-yr-old phantom were (71.38 ± 1.30)% and (53.72 ± 2.42)%, respectively. In SPS + OBTCM mode, the reduction was (71.12 ± 2.54)% and (55.73 ± 1.90)%, respectively. There was significant difference in the noise level of orbit and brain in different phantoms under various scanning modes ( F=5.67-85.47, P< 0.05). The noise level in OBTCM mode compared with reference mode increased slightly (<1.45 HU) in various phantoms. SPS and SPS + OBTCM mode resulted in a small noise increase (<2.58 HU). There was no significant difference in CNR of different phantoms under various scanning modes ( P>0.05). Conclusions:SPS and SPS + OBTCM mode can significantly reduce the radiation dose of lens and the whole image plane in the head CT scan for infants, with maintaining the image quality.

2.
Article in Chinese | WPRIM | ID: wpr-910351

ABSTRACT

Objective:To investigate the value of the size-specific dose estimate (SSDE) on dose estimations of children's head CT scans.Methods:A retrospective study was conducted on plain head CT scans of 252 patients with the 64-row detector CT device of Discovery 750HD in the Union Hospital, Tongji Medical College, Huazhong University of Science and Technology from January to September in 2019. The volume CT dose index (CTDI vol)values were recorded. The head circumference (HC), area, and CT value were measured using a self-developed computer program, and the water equivalent diameter (WED), size-specific conversion factors ( f293 and f220), and absorbed dose (SSDE 293 and SSDE 220) were calculated according to the AAPM reports 293 and 220.The patients were divided into three groups by the quartering meth odaccording to their HC(<47.8 cm, 47.8-52.7 cm, >52.7 cm)and four groups based on their ages(0-2, 3-6, 7-10 and 11-14 years old). The difference between parameters ( f220 and f293, SSDE 220 and SSDE 293、SSDE 293 and CTDI vol) were compared for different groups, and the correlation of HC with f293 and SSDE 293 was analyzed. Results:There was an overestimation of f220 by 11.11% ( t=252.61, P<0.05) compared with f293. SSDE 220 was overestimated by 10.31% ( t=228.21, P<0.05) compared with SSDE 293, and SSDE 293 was underestimated by 9.60% ( t=-31.34, P<0.05)compared with CTDI vol. For the three HC groups, SSDE 220 was overestimated by 8.54%, 10.37%, and 11.57% ( t=73.73, 438.58, 275.52, P<0.05)compared with SSDE 293, and SSDE 293 was underestimated by 1.30%, 9.79%, and 14.61% ( t=-1.91, -60.95, -47.64, P<0.05)compared with CTDI vol. For the four age groups SSDE 220 was overestimated by 8.45%, 10.00%, 10.57%, and 11.36% ( t=63.58, 232.29, 247.84, 302.95, P< 0.05)compared with SSDE 293, and SSDE 293 was underestimated by 1.49%, 8.27%, 10.63%, and 13.78% ( t=-1.83, -28.27, -37.30, -49.80, P< 0.05)compared with CTDI vol. Furthermore, HC was highly correlated with f293 and SSDE 293 ( r2=0.88 and 0.76, respectively, P< 0.05). Conclusions:The radiation dose in children′s head CT scanning can be more accurately estimated according to the AAPM Report 293, while it can be overestimated by CTDI vol. Meanwhile, the CT radiation dose can be patently overestimated with the AAPM Report 220 compared with Report 293.HC is closely correlated with f293 and SSDE 293 and it can be used to estimatee more accurately for SSDE and the radiation dose received by children during head CT scanning.

3.
Article in Chinese | WPRIM | ID: wpr-755005

ABSTRACT

Objective To investigate the effect of scan table on size-specific dose estimate ( size-specific dose estimate, SSDE) in children's CT scan. Methods CT imaging data and CTDIvol of 44 children ( 15 heads, 13 chests, 16 abdomen-pelvis) who underwent Siemens SOMATOM Definition AS+ 64 row 128-slice CT scan were retrospectively collected. CTDIvol of each patient was recored, WED ( water equivalent diameter) was calculated by two different methods ( with or without table) , donated as WED-T and WED-NT, then the corresponding SSDEWED ( SSDEWED-T and SSDEWED-NT ) was calculated. And the SSDEWED-NT was used as reference to evaluate the difference between WED and SSDEWED obtained by two different methods. Results Including part of table will lead to the overestimate for WED, with mean differences of 0. 10%, 2. 82% and 2. 54% for head, chest and abdomen-pelvis, respectively, while SSDEWED will be underestimated by 0. 06% ( head ) , 2. 70% ( chest ) and 1. 59% ( abdomen-pelvis ) . Conclusions Including par of the patient table has a certain effect on SSDEWED for children, more attention should be paid for the application of SSDEWED.

4.
Article in Chinese | WPRIM | ID: wpr-621004

ABSTRACT

Objective To establish a method based on 3D printing radiology equivalent phantom for individual radiotherapy dose verification,and to offer an assurance for the safety of 3D conformal radiotherapy.Methods Two patients' CT data was collected,reconstructing the first patient's skull and brain tissue to generate a skull-brain phantom for the purpose of testing the equivalent material.The second patient's data was used for whole head tissue reconstruction to produce a head phantom with equivalent material.By inserting ionization chamber dosimeters to target region for radiotherapy program,equivalent phantom dose distribution of lesions location was obtained in order to verify and calibrate the actual radiation treatment planning for patients.Results DR,CT images of the phantoms revealed that the difference of X-ray gray value between brain skull phantom and patient's skull was 13 721,CT value difference between equivalent tissue of brain skull phantom and that part of the patient was 35-40 HU,and CT difference between head phantom temporalis and that of the patient tissue was 18-28 HU.The imaging data indicated that the radiation equivalence of 3D printing phantom was similar to that of human body tissue,and the equivalent dose distribution accorded well with the normal range of treatment.The dose verification of phantom model can effectively improve the accuracy of the radiotherapy system.Conclusions The personalized radiotherapy phantom which based on the 3D printing and tissue equivalent technology is suitable for personalized radiation therapy validation.With advantages of easy accessibility,highly-personalized degree and high precision,this technology provides a reliable and safe way for radiation therapy.

5.
Journal of Practical Radiology ; (12): 1848-1850, 2014.
Article in Chinese | WPRIM | ID: wpr-458102

ABSTRACT

Objective To investigate the diffusion-weighted imaging (DWI)characteristics and the correlation of diffusion coeffi-cient (ADC)and differentiation grade of rectal tubular adenocarcinoma.Methods The DWI characteristics of thirty-eight patients pathologically comfirmed rectal tubular adenocarcinomas were evaluated respectively.There were 9 highly differentiated tubular ade-nocarcinomas,1 5 moderately differentiated tubular adenocarcinomas and 14 poorly differentiated tubular adenocarcinomas.The ADC value was calculated from two different factors (0 and 1 000 s/mm2 ).The correlation between ADC value and the differentiated de-gree of tumour was statistically analysed.Results The mean ADC for highly differentiated group was (0.92±0.05)×10 -3 mm2/s, and the mean ADC for moderately differentiated group was (0.79 ± 0.10)× 10 -3 mm2/s whereas that for poorly differentiated group was (0.71±0.06)×10 -3 mm2/s.The difference among three groups was statistically significant(P <0.05).The ADC value and the differentiated degree of tumour were negatively correlated(Spearman r =-0.704)P<0.01.Conclusion DWI and ADC value can be a useful estimating for the differentiation of rectal tubular adenocarcinoma.