Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Journal of Korean Neurosurgical Society ; : 1699-1706, 1999.
Article in Korean | WPRIM | ID: wpr-84569

ABSTRACT

Aneurysms of the posterior inferior cerebellar artery are uncommon, comprising between 0.5 and 0.7% of all intracranial aneurysms and are usually tightly confined to the medulla oblongata, the anterolateral base of the skull, and the lower cranial nerves. During the period from January 1983 to December 1997, about 1,600 aneurysms were operated on the department of neurosurgery, Pusan Paik hospital, Inje University. Of these, there were 8 cases of aneurysms in the posterior inferior cerebellar artery(PICA). The average age was 43.2 years, with a range from 11 months to 56 years, and male to female ratio was equal. Presenting signs and symptoms on admission were mental deterioration and/or headache after subarachnoid hemorrhage in 7 cases and suboccipital headache due to mass effect in 1 case. The locations of these aneurysms were in the anterior-medullary segment in 4 cases, in the lateral medullary segment in one case, and telovelotonsillar segment in 3 cases. Surgical methods were as followed; unilateral suboccipital craniectomy or craniotomy(right side in 3 cases and left side in 2 cases) in lateral or park bench position was performed in 5 cases and suboccipital craniectomy in prone position was in 3 cases. Direct neck clipping were done in 5 cases, proximal ligation in 1 case, coating and trapping in 1 case each. Surgical results were good in 5 cases, fair in 2 cases, dead in a case. Although clipping of the aneurysm neck was preferable in the aneurysm of PICA, trapping was useful when neck clipping was impossible in segments distal to the choroidal arch.


Subject(s)
Female , Humans , Male , Aneurysm , Arteries , Choroid , Cranial Nerves , Headache , Intracranial Aneurysm , Ligation , Medulla Oblongata , Neck , Neurosurgery , Pica , Prone Position , Skull , Subarachnoid Hemorrhage
2.
Experimental & Molecular Medicine ; : 210-216, 1999.
Article in English | WPRIM | ID: wpr-158703

ABSTRACT

The biosynthesis of hypusine [Nepsilon-(4-amino-2-hydroxybutyl)-lysine] occurs in the eIF-5A precursor protein through two step posttranslational modification involving deoxyhypusine synthase which catalyzes transfer of the butylamine moiety of spermidine to the epsilon-amino group of a designated lysine residue and subsequent hydroxylation of this intermediate. This enzyme is exclusively required for cell viability and growth of yeast (Park, M.H. et al., J. Biol. Chem. 273: 1677-1683, 1998). In an effort to understand structure-function relationship of deoxyhypusine synthase, posttranslational modification(s) of the enzyme by protein kinases were carried out for a possible cellular modulation of this enzyme. And also twelve deletion mutants were constructed, expressed in E. coli system, and enzyme activities were examined. The results showed that deoxyhypusine synthase was phosphorylated by PKC in vitro but not by p56lck and p60c-src. Treatment with PMA specifically increased the relative phosphorylation of the enzyme supporting PKC was involved. Phosphoamino acid analysis of this enzyme revealed that deoxyhypusine synthase is mostly phosphorylated on serine residue and weakly on threonine. Removal of Met1-Glu10 (deltaMet1-Glu10) residues from amino terminal showed no effect on the catalytic activity but further deletion (deltaMet1-Ser20) caused loss of enzyme activity. The enzyme with internal deletion, deltaGln197-Asn212 (residues not present in the human enzyme) was found to be inactive. Removal of 5 residues from carboxyl terminal, deltaLys383-Asn387, retained only slight activity. These results suggested that deoxyhypusine synthase is substrate for PKC dependent phosphorylation and requires most of the polypeptide chains for enzyme activity except the first 15 residues of N-terminal despite of N- and C-terminal residues of the enzyme consist of variable regions. Copyright 2000 Academic Press.


Subject(s)
Humans , Oxidoreductases Acting on CH-NH Group Donors/metabolism , Oxidoreductases Acting on CH-NH Group Donors/genetics , Amino Acid Motifs , Amino Acid Sequence , Escherichia coli/genetics , Fungal Proteins/metabolism , Fungal Proteins/genetics , Molecular Sequence Data , NAD/metabolism , Phosphorylation , Promoter Regions, Genetic , Protein Kinase C/metabolism , Recombinant Proteins/metabolism , Recombinant Proteins/genetics , Sequence Deletion , Sequence Homology, Amino Acid , Threonine/metabolism , Yeasts/enzymology
3.
Korean Journal of Preventive Medicine ; : 41-64, 1971.
Article in Korean | WPRIM | ID: wpr-217153

ABSTRACT

During the period from July 1st to the end of November 1970, a survey on air pollution and noise level was made in Seoul, Pusan and Taegu, the three largest cities in Korea. Each city was divided into 4-6 areas : the industrial area, the semi-industrial area, the commercial area, the residential area, the park area and the downtown area. Thirty eight sites were selected from each area. A. Method of Measurement : Dustfall was measured by the Deposit Gauge Method, sulfur oxides by PbO2 cylinder method, suspended particles by the Digital Dust Indicator, Sulfur dioxide (SO2) and Carbon Monoxide (CO) by the MSA & Kitakawa Detector and the noise levels by Rion Sound Survey meter. B. Results: 1. The mean value of dustfall in 3 cities was 30.42 ton/km2/month, ranging from 8.69 to 95.44. 2. The mean values of dustfall by city were 33.17 ton/km2/month in Seoul, 32.11 in Pusan and 25.97 in Taegu. 3. The mean values of dustfall showed a trend of decreasing order of semi-industrial area, downtown area, industrial area, commercial area, residential area, and park area. 4. The mean value of dustfall in Seoul by area were 52.32 ton/km2/month in downtown, 50.54 in semi-industrial area, 40.37 in industrial area, 24,19 in commercial area, 16.25 in park area and 15.39 in residential area in order of concentration. 5. The mean values of dustfall in Pusan by area were 48.27 ton/km2/month in semi-industrial area, 36.68 in industrial area 25.31 in commercial area, and 18.19 in residential area. 6. The mean values of dustfall in Taegu by area were 36.46 ton/km2/month in downtown area, 33.52 in industrial area, 20.37 in commercial area and 13.55 in residential area. 7. The mean values of sulfur oxides in 3 cities were 1.52mg SO3/day/100cm2 PbO2, ranging from 0.32 to 4.72. 8. The mean values of sulfur oxides by city were 1.89mg SO3/day/100cm2 PbO2, in Pusan, 1.64 in Seoul and 1.21 in Taegu. 9. The mean values of sulfur oxides by area in 3 cities were 2.16mg SO3/day/100cm2 PbO2 in industrial area, 1.69 in semi-industrial area, 1.50 in commercial area, 1.48 in downtown area, 1.32 in residential area and 0.94 in the park area, respectively. 10. The monthly mean values of sulfur oxides contents showed a steady increase from July reaching a park in November. 11. The mean values of suspended particles was 2.89mg/m3, ranging from 1.15 to 5.27. 12. The mean values of suspended particles by sity were 3.14mg/m3 in Seoul, 2.79 in Taegu and 2.25 in Pusan. 13. The mean values of noise level in 3 cities was 71.3 phon, ranging from 49 to 99 phon. 14. The mean values of noise level by city were 73 phon in Seoul, 72 in Pusan and 69 in Taegu in that order. 15. The mean values of noise level by area in 3 cities showed a decrease in the order of the downtown area, commercial area, industrial area and semi-industrial area, park area and residental area. 16. The mean values of noise level by area in 3 cities indicated that the highest level was detected in the downtown area in Seoul and Taegu and in the industrial area in Pusan. 17. The daily average concentration o sulfur dioxides (SO2) in 3 cities was 0.081 ppm, ranging from 0.004 to 0.196. 18. The daily average concentration of sulfur dioxides by city were 0.092 ppm in Seoul, 0.089 in Pusan and 0.062 in Taegu in that order. 19. the weekly average concentration of carbon monoxides (CO) was 27.59 ppm. 20. The daily average concentration of carbon monoxides by city were 33.37 ppm. in Seoul, 25.76 in Pusan and 23.65 in Taegu in that order. 21. The concentration of SO2 and CO reaches a peak from 6 p.m. to 8 p.m. 22. About 3 times probably the daily average concentration of CO could be detected in the downtown area probably due to heavy traffic emission in comparison with that in the industrial area. 23. As for daily variation of the concentration of SO2 and CO it was found that the concentration maintains relatively higher value during weekdays in the industrial area and on the first part of the week in the downtown area.


Subject(s)
Air Pollution , Carbon , Carbon Monoxide , Dust , Korea , Noise , Seoul , Sulfur , Sulfur Dioxide , Sulfur Oxides
SELECTION OF CITATIONS
SEARCH DETAIL