Journal of Chinese Physician ; (12): 1528-1532,1537, 2021.
Article in Chinese | WPRIM | ID: wpr-909739

ABSTRACT

Objective:To investigate the relationship between thyroid iodine uptake rate, 99Tc m imaging and treatment of Graves' hyperthyroidism with 131I. Methods:132 patients with Graves' hyperthyroidism were analyzed retrospectively. According to the difference of thyroid 24-hour iodine uptake rate, they were divided into group A (≤50%), group B (50%-80%) and group C (≥80%). According to the trend of iodine uptake rate curve, they were divided into peak advance group (6 h/24 h iodine uptake rate ratio >1) and non-peak advance group (6 h/24 h iodine uptake rate ratio≤1). Thyroid 99Tc m imaging was divided into three groups according to quality, including group 1 (≤30 g), group 2 (30-60 g) and group 3 (≥60 g). The therapeutic effects of 131I in different types of patients were compared. Results:132 patients were followed up for 6 months after the first 131I treatment. The total effective rate, total cure rate and uncured rate were 88.6%(117/132), 78.0%(103/132), 22.0%(29/132), respectively. The serum thyroxine levels of patients with different 24-h iodine uptake rates in the three groups after treatment were significantly lower than those before treatment ( P<0.05). The lower the 24-h iodine uptake rate of thyroid, the more significantly the serum total triiodothyronine (TT3), total triiodothyronine (TT4), free triiodothyronine (FT3) and free thyroxine (FT4) levels decreased after treatment, the more obvious the increase of thyroid stimulating hormone (TSH), and the more obvious the treatment effect ( P<0.05). The cure rate (13/29, 44.8%) in the peak advance group was significantly lower than that in the non peak advance group (90/103, 87.4%), with statistically significant difference (χ 2=23.899, P<0.001). There was significant difference in the cure rate among the three groups with different thyroid 99Tc m imaging quality (χ 2=15.502, P<0.001). Conclusions:With the increase of thyroid mass, the higher the 24-h iodine intake rate, the more obvious the peak shift, the lower the cure rate, the higher the non-healing rate, and the lower the incidence of hypothyroidism.

2.
Chinese Journal of Endocrine Surgery ; (6): 353-357, 2021.
Article in Chinese | WPRIM | ID: wpr-907805

ABSTRACT

Objective:To investigate the diagnostic efficacy of 99Tc m-MIBI SPECT dual-phase imaging combined with rapid parathyroid hormone detection in thyroid cancer with suspected parathyroid mass. Methods:Data of 76 cases of thyroid cancer with suspected cervical parathyroid gland tumors receiving colorectal ultrasonography or CT examination in Thyroid Surgery Department of the Affiliated Cancer Hospital of Zhengzhou University were retrospectively analyzed. Blood samples were taken before surgery to detect parathyroid hormone. Parathyroid hormone was quickly detected after clamping the tumor blood vessels during surgery. Based on the postoperative pathological results, the sensitivity, specificity, accuracy and consistency of various diagnostic methods were evaluated. The ROC curve was drawn by measuring the value of the parathyroid gland concentration after reduction of the tumor blood vessels by clamping the tumor.Results:The sensitivity and accuracy of the 99Tc m-MIBI SPECT dual-phase imaging combined with the rapid detection of parathyroid hormone in diagnosis of suspected parathyroid tumors were (96.5%, 93.4%) better than the 99Tc m-MIBI SPECT dual-phase imaging methods (77.6%, 78.9%) and intraoperative rapid detection methods (86.2%, 82.8%) , and had a high consistency with the results of pathological examination, Kappa value of 0.81. The combined detection rate of suspected parathyroid tumors was significantly higher than that of 99Tc m-MIBI SPECT dual-phase imaging and rapid intraoperative detection, but there was no significant difference between 99Tc m-MIBI SPECT dual-phase imaging and intraoperative rapid detection. The area under the ROC curve of the reduction ratio a value after clamping the blood vessels of the tumor was 0.774, and the standard error was 0.073. The difference was statistically significant ( P<0.001,95% CI:0.631-0.918) . According to the results obtained by the ROC, the index (sensitivity + specificity-1) was plotted on the ordinate and a was the abscissa. The maximum value of the Jordan index was 0.584. The a value corresponding to this point was 0.52. 0.52 is the DCP value. The corresponding sensitivity, specificity, accuracy was 86.2%,72.2%,and 82.9%. Conclusion:99Tc m-MIBI SPECT dual-phase imaging combined with rapid parathyroid hormone detection during surgery has good diagnostic value for thyroid cancer with suspected parathyroid mass, and is completely consistent with pathological diagnosis.

3.
Radiol. bras ; 42(4): 255-259, jul.-ago. 2009. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-524405

ABSTRACT

OBJETIVO: Avaliar o desempenho dos calibradores de radionuclídeos de 55 serviços de medicina nuclear brasileiros em medição de atividade de radiofármaco contendo 99Tc m. Testes de proficiência foram aplicados em 63 resultados originados do programa de comparação promovido pelo Laboratório Nacional de Metrologia das Radiações Ionizantes do Instituto de Radioproteção e Dosimetria. MATERIAIS E MÉTODOS: O desempenho foi avaliado em relação ao critério de aceitação de ±10 por cento de exatidão exigido pela norma brasileira e também aos critérios estabelecidos pela ISO/IEC Guide 43-1, e classificado como "aceitável" ou "não aceitável". Amostras de 99Tc m usadas nas comparações foram fornecidas por alguns dos participantes e calibradas no Laboratório Nacional de Metrologia das Radiações Ionizantes para determinar o valor de referência da atividade. RESULTADOS: Esta comparação com o 99Tc m mostrou que o desempenho aceitável atendendo à exigência da norma regulatória foi de 82,5 por cento, enquanto pelos critérios estabelecidos pela norma ISO/IEC 43-1 foi de 81,0 por cento. Por outro lado, calibradores de radionuclídeos com detector Geiger-Müller apresentaram desempenho inferior quando comparados com os dotados com câmara de ionização. CONCLU-SÃO: Nesta comparação, a avaliação do desempenho baseada nos critérios da ISO/IEC 43-1, os quais são aplicados a laboratórios analíticos, apesar de serem mais restritivas, foi bastante consistente com o critério de exatidão exigido pela norma nacional.


OBJECTIVE: To assess the performance of radionuclide calibrators in 55 Brazilian nuclear medicine services in the measurement of 99Tc m radiopharmaceutical activity. Proficiency tests were applied to data sets with 63 results originated from the comparison program developed by Laboratório Nacional de Metrologia das Radiações Ionizantes of Instituto de Radioproteção e Dosimetria. MATERIALS AND METHODS: The calibrators' performance was evaluated in compliance with the acceptance criterion of ±10 percent accuracy required by the Brazilian standards and also the criteria established by the ISO/IEC Guide 43-1, and classified as either "acceptable" or "non-acceptable". The samples of 99Tc m utilized in the comparison were supplied by some of the participants and calibrated at Laboratório Nacional de Metrologia das Radiações Ionizantes for determining the activity reference value. RESULTS: The present study utilizing 99Tc m has shown that 82.5 percent of the calibrators were considered as acceptable according to the Brazilian standards, while by the criteria established by ISO/IEC 43-1, 81.0 percent were considered as acceptable. On the other hand, radionuclide calibrators with Geiger-Müller detectors presented unsatisfactory performance when compared with calibrators with ionization chambers. CONCLUSION: The performance evaluation based on the ISO/IEC 43-1 criteria, which are applied to analytical laboratories, in spite of being more restrictive, has demonstrated to be quite consistent with the accuracy criterion established by the Brazilian standard.


Subject(s)
Dosimetry/methods , Nuclear Medicine/standards , Radioisotopes , Radioisotopes , Calibration , Maximum Acceptable Dose
4.
Cancer Research and Clinic ; (6)2006.
Article in Chinese | WPRIM | ID: wpr-544214

ABSTRACT

Objective To investigate the diagnostic value of 18F-FDG PET and 99Tcm-MDP imaging in detection bone metastases. Methods 93 patients were undergone 18F-FDG PET and 99Tcm-MDP imaging within 2 weeks. The results of the 2 different modalities were analyzed. Results Of the 93 patients, 64 patients were found to have bone metastases by PET and MDP imaging. Among the 64 patients, 43 patients were found both positive PET and MDP. 16 patients had positive PET whereas negative MDP. 5 patients had negative PET whereas positive MDP. The sensitivity, specificity and accuracy of 18F-FDG PET and 99Tcm-MDP imaging were 92.2 %, 75.0 %(P 0.05), 92.5 %,76.3 %(P

5.
Journal of Third Military Medical University ; (24)2003.
Article in Chinese | WPRIM | ID: wpr-560572

ABSTRACT

Objective To prepare and explore the pharmacokinetic parameters for ~ 99 Tc~ m -ASON-EGF in healthy rabbits. Methods ~ 99 Tc~ m -ASON-EGF was prepared according to previous methods and its changes of concentration in blood were measured by radioactivity counts per minute. The experimental data were dealt with by 3p97 software and its true compartment model was estimated by AIC value, R~ 2 value, the 1/c and F test. Subsequently, its half-life of distribution (T_ 1/2 ?), half-life of elimination (T_ 1/2 ?), central compartment volume of distribution (Vc), total apparent volume of distribution (Vd) and total rate of clearance (CL) were calculated by the software. Finally, the binding rate of plasma protein was determined by trichloroacetic acid precipitation. Results The best model of ~ 99 Tc~ m -ASON-EGF in vivo was two-compartment model and its T_ 1/2 ?, T_ 1/2 ?, Vc, Vd and CL were 5.28 min, 89.23 min, 67.8 ml, 915.6 ml and 7.1 ml/min respectively. After being incubated with fresh plasma for 1.5 h, its binding rate was 10.69%. Conclusion Its process of transportation in healthy rabbits is fitted to two-compartment model and the pharmacokinetic properties are desirable.

6.
Journal of Medical Postgraduates ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-586207

ABSTRACT

Objective: To develop ~(99)Tc~m labeled dopamine transporter(DAT) imaging agent ~(99)Tc~m-(2?-[N,N~(,)-bis(2-mercaptoethyl)ethylenediamino]methyl,3?-(4-chlorophenyl)tropane(TRODAT-1) for evaluating changes of DAT in patients with Parkinson disease(PD). Methods: The SD rats were divided into control group(n=5),PD models group(n=22)and generalized cerebral infarction models group(n=5).~() Unilateral smashing and injecting autothrombo into carotid artery of SD rats were used.~(99)Tc~m-TRODAT-1 distributing in normal rat striatum was observed.The uptakes in sound side and smashed side of PD rats striatum and in two sides of multiple infarction rats striatum were compared. Results:~(99)Tc~m-TRODAT-1 distribution in normal rats striatum exhibited a obvious uptake in striatum.And PD rats results exhibited that the uptake was less in normal striatum than in smashed striatum obviously.The result of multiple infarction rats is same as normals rats. Conclusion: ~(99)Tc~m-TRODAT-1 might betaked specificly.Its imaging can provide a beneficial evidence for PD disease early diagnose.