Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Rev. méd. Maule ; 34(2): 58-67, dic. 2019. ilus, tab
Article in Spanish | LILACS | ID: biblio-1371322

ABSTRACT

Flexor tendon tenosynovitis is an entrapment of the flexor tendons at its entrance to the pulley system. Because there is a high incidence of this pathology, it should be well known by physicians, rheumathologists and orthopaedic surgeons. On this paper we present a literature review, analyzing the anatomic facts, biomechanics, diagnosis, classification, therapeutic options and we propose some general recommendations for physicians.


Subject(s)
Humans , Tenosynovitis/etiology , Tenosynovitis/epidemiology , Trigger Finger Disorder/diagnosis , Trigger Finger Disorder/therapy , Tenosynovitis/classification , Biomechanical Phenomena , Incidence , Neutrophil Infiltration , Trigger Finger Disorder/surgery , Anatomy
2.
Article in Korean | WPRIM | ID: wpr-109358

ABSTRACT

PURPOSE: Trigger thumb is a common condition with a prevalence rate up to 3% among the adults. The main pathophysiology is locking of the flexor tendon at the A1 pulley. Treatments include nonsteroidal anti-inflammatory drug, steroid injection, and surgical A1 pulley release. The purpose of this study was to evaluate the safety and effectiveness of ultrasound-guided percutaneous release of trigger thumb. METHODS: The author prospectively reviewed 37 patients who had undergone ultrasound-guided percutaneous release by the same surgeon from January 2012 to June 2014. The effect of ultrasound-guided A1 pulley release was evaluated by using visual analogue scale (VAS) score, disabilities of arm, shoulder, and hand (DASH) score, and grip and pinch strengths preoperatively and at 12weeks after the surgery. In addition, complications related with the procedure were evaluated. RESULTS: Triggering and locking were resolved in all patients after surgery. VAS and DASH improved from 5.0±1.8 and 45.8±16.9 preoperatively to 0.3±0.6 and 16.2±6.3 at 12 weeks, respectively (p=0.019 and p=0.021). Grip and pinch strengths statistically improved from33.5±8.6 kg and 36.7±8.1 kg, preoperatively 46.2±6.1 kg and 47.1±7.4 kg, respectively (p=0.026 and p=0.041). Complications such as incomplete resection, neurologic symptoms or wound infection were not found throughout the period of the study. CONCLUSION: Ultrasound-guided percutaneous A1 pulley release provides complete relief of symptoms with no major complication in trigger thumb.


Subject(s)
Adult , Humans , Arm , Hand , Hand Strength , Neurologic Manifestations , Pinch Strength , Prevalence , Prospective Studies , Shoulder , Tendons , Trigger Finger Disorder , Ultrasonography , Wound Infection
3.
Article in Korean | WPRIM | ID: wpr-653709

ABSTRACT

Trigger finger is one of the most common causes of hand pain and disability. Persistent trigger finger after conservative treatment has been managed with surgical release of the A1 pulley. Percutaneous A1 pulley release is being increasingly performed and many authors have reported comparable outcomes with open surgical release. However, complications have been reported, including incomplete release, flexor tendon injury, and neurovascular injury due to the blind nature of the procedure. We report on a case of a 49-year-old female who presented with features of a type I complex regional pain syndrome (CRPS) following percutaneous A1 pulley release. CRPS is a relatively common complication occurring after trauma and surgical procedures of the upper extremities. We experienced a case of CRPS following percutaneous A1 pulley release which was treated effectively following early diagnosis and through a multidisciplinary approach including physical therapy and medication.


Subject(s)
Female , Humans , Middle Aged , Complex Regional Pain Syndromes , Early Diagnosis , Fingers , Hand , Reflex Sympathetic Dystrophy , Tendon Injuries , Trigger Finger Disorder , Upper Extremity
4.
Article in Korean | WPRIM | ID: wpr-45589

ABSTRACT

PURPOSE: To describe the surgical treatment of the complex dorsal metacarpophalangeal dislocations and its results, emphasizing on the modified volar approach with A1 pulley release. MATERIALS AND METHODS: We experienced 6 cases of dorsal dislocation of the metacarpophalangeal joint. We performed open reduction with the modified volar approach described by Eaton and Dray. Postoperatively posteroanterior and lateral radiographs of the index finger metacarpophalangeal joint and metacarpophalangeal joint range of motion was followed. RESULTS: One case with a large osteochondral fracture was operated with volar and doral approach both. Overall end results were good without any significant restriction of motion and stability of the fingers. CONCLUSION: Modified volar approach with A1 pulley release is an excellent method for complex dorsal metacarpophalangeal dislocations without osteochondral fracture.


Subject(s)
Benzodiazepines , Joint Dislocations , Fingers , Metacarpophalangeal Joint , Range of Motion, Articular
SELECTION OF CITATIONS
SEARCH DETAIL