Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
The Journal of Advanced Prosthodontics ; : 62-69, 2016.
Article in English | WPRIM | ID: wpr-211465

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the effects of abutment screw length and cyclic loading on the removal torque (RTV) in external hex (EH) and internal hex (IH) implants. MATERIALS AND METHODS: Forty screw-retained single crowns were connected to external and internal hex implants. The prepared titanium abutment screws were classified into 8 groups based on the number of threads (n = 5 per group): EH 12.5, 6.5, 3.5, 2.5 and IH 6.5, 5, 3.5, 2.5 threads. The abutment screws were tightened with 20 Ncm torque twice with 10-minute intervals. After 5 minutes, the initial RTVs of the abutment screws were measured with a digital torque gauge (MGT12). A customized jig was constructed to apply a load along the implant long axis at the central fossa of the maxillary first molar. The post-loading RTVs were measured after 16,000 cycles of mechanical loading with 50 N at a 1-Hz frequency. Statistical analysis included one-way analysis of variance and paired t-tests. RESULTS: The post-loading RTVs were significantly lower than the initial RTVs in the EH 2.5 thread and IH 2.5 thread groups (P<.05). The initial RTVs exhibited no significant differences among the 8 groups, whereas the post-loading RTVs of the EH 6.5 and EH 3.5 thread groups were higher than those of the IH 3.5 thread group (P<.05). CONCLUSION: Within the limitations of this study, the external hex implants with short screw lengths were more advantageous than internal hex implants with short screw lengths in torque maintenance after cyclic loading.


Subject(s)
Axis, Cervical Vertebra , Crowns , Dental Implant-Abutment Design , Molar , Titanium , Torque
2.
The Journal of Korean Academy of Prosthodontics ; : 432-442, 2006.
Article in Korean | WPRIM | ID: wpr-84194

ABSTRACT

Statement of problem: One of common problems associated with dental implant is the loosening of abutment screws that retain the implants. Purpose: This study was performed to investigate the influence of abutment screw length and repeated tightening on screw loosening in dental implant. Material and method: Forty nine Hexplants (13mm length, 4.3mm diameter, Ti grade IV, Warantec. Co. Ltd. Seongnam, Korea) and cementation type abutments(straight abutment) and abutment screws (0.4mm/pitch) were divided into 7 groups, depending on abutment screw length. Each implant and abutment was tightened to 30Ncm by torque controller(MGT50, MARK-10 Inc., USA) and the removal torque values were measured during 10 consecutive closure/opening trials Results and Conclusion: The results of comparing the removal torque value are as follows: 1. There is no significant difference in the removal torque value between groups in 10 consecutive closure/opening trials(p=0.97). 2. If the fractured abutment screw is engaged in longer than 2.425 thread length, there is no significant difference in the preload between the fractured abutment screw and the new abutment screw when both are equally tightened to 30 Ncm 3. The removal torque value in the 1st trial(24.510 Ncm) was lower than that in the 2nd,3rd,4th,5th,6th,7th trials and the removal torque value in the 2nd trials(25.551 Ncm) was maximum and was decreased in following trials. The removal torque value in the 1st trial was significantly lower than that in the 2nd,3rd,4th trials and was significantly higher than that in the 8th,9th,10th trials(p<0.05). 4. In the 2nd,3rd,4th,5th,6th,7th trials, the abutment screw was mainly influenced by settling effect and the higher preload was obtained. In the 8th,9th,10th trials, the abutment screw was mainly influenced by adhesive wear and the progressively lower preload was obtained.


Subject(s)
Adhesives , Cementation , Dental Implants , Torque