1.
Cancer Research on Prevention and Treatment ; (12): 110-114, 2024.
Article in Chinese | WPRIM | ID: wpr-1011507

ABSTRACT

Objective To explore a precise method with a microwave antenna for puncture of pulmonary nodules and analyze phenomena that affect the puncture results. Methods Clinical data of 107 cases with solitary malignant pulmonary nodules were collected, and the mean length of pulmonary nodules was 13.6±0.6 mm in CT axial position. A thread-hanging method was used to assist the puncture of pulmonary nodules. The procedure was successful when the needle was not withdrawn and inserted into the central region of the nodule. The success rate and complications of the pulmonary procedure were recorded. The incidence of the following phenomena were also documented: needle coercing, needle slipping, needle tip pushing, pulmonary nodule prolapsing, radial nodule deformation, nodular masking, and radial movement distance of needle tip. Results In all of 107 cases evaluated, the antenna puncture was successful in 101 cases (94.4%) but failed in 6 cases (5.6%). Pneumothorax and pulmonary hemorrhage occurred in 23 (21.5%) and 19 cases (17.8%), respectively. The following phenomena occurred: needle coercing in 9 cases (8.4%), needle slipping in 6 cases (5.6%), needle tip pushing in 19 cases (17.8%), pulmonary nodule prolapsing in 15 cases (14%), radial nodule deformation in 14 cases (13.1%), and nodular masking in 5 cases (4.7%). The mean radial adjusting distance of needle tip was 0.7±0.4 cm. Conclusion The thread-hanging method can assist in the accurate puncture of microwave antenna for pulmonary nodules. We should focus and deal with phenomena that may occur and affect the result of puncture.

2.
Chinese Journal of Urology ; (12): 698-702, 2018.
Article in Chinese | WPRIM | ID: wpr-709585

ABSTRACT

Objective To explore the clinical significance of fused renal pyramid (FRP) structure in the establishment of percutaneous renal access.Methods From May 2017 to April 2018,10 fresh porcine kidneys were selected to cast in blood vessels for grading the kidney artery.Then another 80 isolated porcine kidueys were used to simulate percutaneous renal pu ncture and dilatation to establish F24 operative access by the same surgeon.Under the endoscope and microscope,we compared the effects of four different puncture paths on the occurrence of renal vascular injury when respectively punctured through the normal renal pyramid (group A),the side of the FRP (group B),the centre of the FRP (group C) and the renal column (group D).Results The kidney arteries can be divided into six grades,there is grade Ⅳ branchinterlobar artery walking inside the FRP.The diameter of interlobar artery in the FRP was significantly smaller than that in the renal column (0.442 ±0.012) mm vs.(0.778 ±0.037) mm,(P <0.001).Endoscopic observation and pathological tissue section showed the following results.In group A,there was no injured blood vessel distributed along the access.There were six specimens with grade Ⅴ or Ⅵ arteries injury in the cortex.Owing to the small size of the renal pyramid and the inaccurate location of the puncture,there was also injury associated with a normal grade Ⅳ artery in the renal column.In group B,there was a certain distance between the tract and the grade Ⅳ artery that distributed in the FRP,injury was still noticed in four specimens.And six specimens have grade Ⅴ/Ⅵ arterial injury.As the distance between the tract and the renal column decreased,there was a case in which a simultaneously injury occurred to the extremity of a grade Ⅲ artery and a grade Ⅳ artery.In group C,there was a white thin strip of connective tissue exposed along the puncture tract.Ectopic grade Ⅳ artery injury occurred in fourteen specimens,and grade Ⅴ/Ⅵ artery injury occurred in seven specimens.In group D,there were grade Ⅲ to Ⅵ arteries distributed along the operational access,which was cowered with white fat and connective tissue.The number of arteryinjury in grades Ⅲ,Ⅳ,and Ⅴ/Ⅵ were4,19,and 5,respectively.The mean ranks of artery injury degree in groups A (17.0),B (30.1),C (33.5) and D (41.5) gradually increased,and the difference was significant (P =0.006).There was a significant difference between group A and C (P =0.018),while no significant difference between group A and B (P =0.122),groups C and D (P =0.072).The proportion of grade Ⅳ artery injury in group A,B,and C was 5% (1/20),25% (5/20),and 70% (14/20),respectively.There was a significant difference between group A and C (P =0.029),while no significant difference between group A and B (P =0.316).There was no significant difference in the injury of grade Ⅴ and Ⅵ artery in four groups (P =0.827).Conclusions When establishing a percutaneous renal access,vascular injury caused bv puncturing through the FRP cannot be ignored.It is necessary to carefu lly identify and bypass the FRP when selecting the puncture path.If unavoidable,the puncture path shoull be on the centreline of one side pyramid of the FRP.

SELECTION OF CITATIONS
SEARCH DETAIL