Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
Article in English | LILACS-Express | LILACS | ID: biblio-1405321

ABSTRACT

ABSTRACT: Bioactive materials have shown positive results in reducing the deleterious effects of tooth whitening. However, their effects on whitening efficacy is still uncertain. Therefore, the aim of this study was to evaluate the effects of F- 18 bioactive glass incorporation into a bleaching gel on color and microhardness of enamel after tooth whitening. Thirty bovine enamel-stained specimens were randomly divided into three groups (n=10) according to the whitening protocol: control group (unbleached), HP35 % (35 % hydrogen peroxide) and F-18 (F-18 bioactive glass incorporated into HP35 %). pH, color change and microhardness analyzes were performed at baseline, 24 hours and 7 days after tooth whitening. Color evaluation showed that experimental groups were different than control group for all coordinates (p 0.05). No differences in enamel microhardness were found among the groups within the same evaluation time (p > 0.118). Regarding the intragroup comparisons, no differences were observed for control and F-18 groups (p > 0.129). It was concluded that F-18 bioactive glass incorporation did not affect the whitening efficacy and the enamel microhardness.


RESUMEN: Los materiales bioactivos han mostrado resultados positivos en la reducción de efectos nocivos del aclaramiento dental. Sin embargo, sus efectos sobre la eficacia del aclaramiento aún son inciertos. Por lo tanto, el objetivo de este estudio fue evaluar los efectos de la incorporación de vidrio bioactivo F-18 en un gel aclarador sobre el color y la microdureza del esmalte después del aclariamiento dental. Treinta especímenes bovinos teñidos con esmalte se dividieron aleatoriamente en tres grupos (n=10) de acuerdo con el protocolo de aclaramiento: grupo control (sin aclaramiento), HP35 % (peróxido de hidrógeno al 35 %) y F-18 (vidrio bioactivo F-18 incorporado en HP35 %). Se realizaron análisis de pH, cambio de color y microdureza al inicio del estudio, 24 horas y 7 días después del aclaramiento dental. La evaluación del color mostró que los grupos experimentales eran diferentes al grupo de control en todas las coordenadas (p 0,05). No se encontraron diferencias en la microdureza del esmalte entre los grupos dentro del mismo periodo de evaluación (p > 0,118). En cuanto a las comparaciones intragrupos, no se observaron diferencias para los grupos control y F-18 (p > 0,129). Se concluyó que la incorporación de vidrio bioactivo F-18 no afectó la eficacia de aclaramiento ni la microdureza del esmalte.

2.
Med. crít. (Col. Mex. Med. Crít.) ; 36(8): 507-513, Aug. 2022. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1506681

ABSTRACT

Resumen: Introducción: la asociación del nivel de lactato con la mortalidad en pacientes con sospecha de infección y sepsis está bien establecida. La sensibilidad es entre 66 y 83%, con especificidad de 80 y 85%. Sin embargo, el lactato no es sensible ni lo suficientemente específico para detectar o descartar el diagnóstico por sí solo, ya que el lactato sérico es un biomarcador importante de la hipoxia y disfunción tisular, pero no es una medida directa de la perfusión tisular. El lactato y la base estándar medidos al ingreso a la Unidad de Cuidados Intensivos (UCI) son de utilidad pronóstica en los pacientes críticamente enfermos, pues sus niveles séricos predicen mortalidad a través de la puntuación en sí misma. Pero la importancia real va más allá de un valor absoluto, pues es mejor medir su aclaramiento a través de un tiempo determinado. Objetivo: demostrar que el aclaramiento de lactato y déficit de base estándar registrados al ingreso y a las 24 h se relacionan con mejor pronóstico y disminución de mortalidad en choque séptico. Material y métodos: se utilizó estadística descriptiva (medidas de tendencia central y dispersión; así como frecuencias y porcentajes). Asimismo, se ocupó estadística inferencial con la prueba t de Student, χ2, curva ROC, área bajo la curva e índice de Youden, con un intervalo de confianza de 95%. Resultados: la asociación estadística con la mortalidad se presentó en el aclaramiento de déficit de base estándar y en aclaramiento de lactato. Conclusión: se demostró que el aclaramiento de lactato y déficit de base estándar registrados al ingreso y a las 24 h se relacionaron con mejor pronóstico y disminución de mortalidad en pacientes con choque séptico.


Abstract: Introduction: the association of lactate level with mortality in patients with suspected infection and sepsis is well established. Sensitivity is between 66 and 83%, with specificity between 80 and 85%. However, lactate is neither sensitive nor specific enough to detect or rule out the diagnosis on its own as serum lactate is an important biomarker of tissue hypoxia and dysfunction but is not a direct measure of tissue perfusion. Lactate and standard base measured on admission to the Intensive Care Unit (ICU) are useful for prognosis in critically ill patients since their serum levels predict mortality through the score itself. But the real importance goes beyond an absolute value, since it is better to measure its clearance over a given time. Objective: to demonstrate that lactate clearance and standard base deficit recorded at admission and at 24 hours are related to a better prognosis and decreased mortality in septic shock. Material and methods: descriptive statistics were used (measures of central tendency and dispersion, as well as frequencies and percentages). Likewise, inferential statistics were used with the Student's t test, χ2, ROC curve, area under the curve and Youden index, with a confidence interval of 95%. Results: the statistical association with mortality was presented in the clearance of standard base deficit and in lactate clearance. Conclusion: it was shown that lactate clearance and standard base deficit recorded at admission and at 24 hours were related to a better prognosis and decreased mortality in patients with septic shock.


Resumo: Introdução: a associação do nível de lactato com mortalidade em pacientes com suspeita de infecção e sepse está bem estabelecida. A sensibilidade está entre 66 e 83%, com especificidade de 80 e 85%. No entanto, o lactato não é sensível nem específico o suficiente para detectar ou descartar o diagnóstico por si só, uma vez que o lactato sérico é um importante biomarcador de hipóxia e disfunção tecidual, mas não é uma medida direta da perfusão tecidual. O lactato e a base padrão medidos na admissão na UTI são de utilidade prognóstica em pacientes críticos, uma vez que seus níveis séricos predizem a mortalidade pelo próprio escore. Mas a real importância vai além de um valor absoluto, pois é melhor medir sua depuração em um determinado tempo. Objetivo: demonstrar que a depuração de lactato e o déficit de base padrão registrados na admissão e em 24 horas estão relacionados a um melhor prognóstico e diminuição da mortalidade no choque séptico. Material e métodos: foi utilizada estatística descritiva (medidas de tendência central e dispersão, bem como frequências e percentagens). Da mesma forma, foi utilizada estatística inferencial com teste t de Student, χ2, curva ROC, área sob a curva e índice de Youden, com intervalo de confiança de 95%. Resultados: a associação estatística com a mortalidade foi apresentada na depuração do déficit de base padrão e na eliminação do lactato. Conclusão: foi demonstrado que a depuração de lactato e o déficit de base padrão registrados na admissão e em 24 horas foram relacionados a um melhor prognóstico e diminuição da mortalidade em pacientes com choque séptico.

3.
Rev. cient. odontol ; 9(2): e058, abr.-jun. 2021. ilus, tab
Article in Spanish | LILACS, LIPECS | ID: biblio-1254597

ABSTRACT

Objetivo: Comparar el pH de cuatro marcas de geles aclaradores a base de peróxido de hidrógeno de altas concentraciones (30%-35%) Whiteness HP Maxx (HPM), Lase Peroxide (LP), Whiteness HP Automixx (HPA)y Dash (DA), a través del tiempo de aplicación clínica (inicio, 15', 30' y 45'). Materiales y métodos: El estudio fue experimental in vitro. Se evaluaron 40 muestras (dientes bovinos) divididos en 4 grupos, uno para cada marca comercial de gel. Se preparó cada gel de acuerdo con las instrucciones del fabricante y se colocó una cantidad necesaria en la superficie vestibular; posteriormente, se registró el pH del gel con un pHmetro digital al inicio, 15, 30 y 45 minutos. Los datos se analizaron con las pruebas Anova, Friedman y Wilcoxon. Resultados: Hubo una tendencia a la disminución del pH desde el tiempo inicial de aplicación hasta el tiempo final, con excepción del grupo de la marca DA, el cual mostró que los valores del pH fueron aumentando a través del tiempo. En la marca HPM, existe una diferencia significativa entre el tiempo inicial de aplicación del gel y el resto de tiempos. En la marca LP, a partir de los 15' de aplicación, sí hay diferencia significativa entre los tiempos. En cuanto a la marca HPA, existieron diferencias significativas entre el tiempo inicial de aplicación y los demás tiempos. Finalmente, con la marca DA se encontró únicamente una diferencia significativa entre el tiempo inicial de aplicación y el tiempo final. Conclusiones: El pH de los geles aclaradores disminuyó a través del tiempo de aplicación clínica en todas las marcas estudiadas, con excepción de la marca Dash 30%, la cual mostró un aumento. (AU)


Objective: The aim of this in vitro study was to evaluate the pH of four bleaching agents based on high concentration hydrogen peroxide (30-35%) Whiteness HP Maxx (HPM), Lase Peroxide (LP), Whiteness HP Automixx (HPA) and Dash (DA) in different clinical periods (baseline, 15', 30' and 45'). Materials and methods: 40 specimens (bovine teeth) were divided into 4 groups; one group for each bleaching agent. Each bleaching agent was prepared according to the manufacturer's instructions and was applied on the vestibular surface. The pH of the bleaching agent was measured with a digital pH meter at baseline, 15, 30 and 45 minutes. ANOVA, Friedman and Wilcoxon tests were applied. Results: The pH values showed a trend to decreasing from the initial time of application to the final time, except for the DA group, which showed increasing pH values over time. The HPM group showed significant differences between baseline and the remaining periods. The LP group LP showed significant difference between 15' and the other periods. The HPA group showed significant differences between baseline and the remaining periods. Finally, the DA group, showed a significant difference between baseline and 45'. Conclusions: The pH values of 3 of the bleaching agents decreased over time, with the exception of Dash which increased in the different time periods. (AU)


Subject(s)
Tooth Bleaching , Hydrogen-Ion Concentration , Hydrogen Peroxide , In Vitro Techniques
4.
Odontol. sanmarquina (Impr.) ; 24(1): 69-74, Ene-Mar. 2021.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1150872

ABSTRACT

El intervalo de tiempo trascurrido pos aclaramiento dentario es una variable significativa para la adhesión a la estructura dentaria. Los agentes aclaradores utilizados sobre la superficie del esmalte, debido a la degradación de los peróxidos empleados generan radicales libres de oxígeno que alteran la fuerza de adhesión. La literatura ha demostrado que el tiempo trascurrido desde un aclaramiento hasta el momento de la restauración es determinante para la adhesión al esmalte. El objetivo de este trabajo fue hacer una revisión de literatura sobre la influencia del tiempo pos aclaramiento dental y su efecto en la fuerza de adhesión al esmalte dental de las resinas compuestas. Para la recopilación de datos se utilizaron las siguientes bases de datos: SciELO, EBSCO y repositorios académicos, obteniéndose 36 artículos y tesis. Después del análisis, se puede considerar que el tiempo es determinante en la resistencia adhesiva y que las alteraciones posteriores al aclaramiento dentario se extienden hasta la semana posterior prolongándose inclusive hasta cuatro semanas, tiempo que la literatura estima necesario para la eliminación del oxígeno residual.


The time interval after tooth bleaching is a significant variable for the adhesion to the tooth structure. The bleaching agents used on the enamel surface, due to the degradation of the peroxides used, generate oxygen free radicals that alter the bonding strength. The literature has shown conclusively that the time that has elapsed since a bleaching to the moment of restoration is decisive for the adhesion to the enamel. The objective of this work was to review the literature about the influence of time after dental bleaching and its effect on the strength of adhesion to enamel of composite resins. Data collection was carried out through electronic databases such as: Scielo, EBSCO, academic repositories, obtaining 36 articles and thesis. After the analysis, it can be considered that time is decisive in the adhesive resistance and that the alterations after tooth bleaching extend until the subsequent week, lasting up to four weeks, a time that the literature considers necessary for the elimination of residual oxygen.

5.
Ginecol. obstet. Méx ; 89(12): 919-926, ene. 2021. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1375556

ABSTRACT

Resumen OBJETIVO: Determinar y comparar el aclaramiento de creatinina de largo plazo con el inicial en pacientes con hemorragia obstétrica. MATERIALES Y MÉTODOS: Estudio observacional, longitudinal, retrospectivo, comparativo y analítico llevado a cabo en una serie de pacientes con hemorragia obstétrica (pérdida ≥ 1000 mL) hospitalizadas en la unidad de cuidados intensivos. El aclaramiento de la creatinina se calculó con la fórmula CKD-EPI en dos momentos: al ingreso a cuidados intensivos durante el puerperio inmediato, complicado por hemorragia (medición inicial) y de su última consulta médica registrada (medición de largo plazo). Se utilizó estadística descriptiva y la prueba t de Student con el programa SPSS versión 20. Se consideró significativo el valor de p < 0.05. RESULTADOS: Se estudiaron 49 pacientes con media de edad de 30.48 ± 6.06 años y 32.20 ± 8.24 semanas de embarazo. En 39 de 49 se practicó cesárea, 5 de 49 tuvieron parto, 4 de 49 requirieron histerotomía y solo 1 legrado instrumental. La media de sangrado estimado fue de 2744.89 ± 1474.65 mL. Para su control se requirió cirugía en 13 de 49, dos intervenciones en 21 de 49 y tres operaciones en 15 de 49. Aclaramiento de la creatinina: medición inicial 159.09 ± 46.62 y de largo plazo (22.27 ± 1.55 meses después) 112.23 ± 30.91 mL de min de 1.73 m2 de superficie corporal. La diferencia fue significativa (p = 0.002). En la medición de largo plazo se encontró enfermedad renal crónica en 1 de las 49 pacientes. CONCLUSIONES: El aclaramiento de la creatinina de largo plazo resultó menor, quizá por la regresión de los cambios gestacionales al paso del tiempo, pero sin deterioro funcional importante, salvo un caso con enfermedad renal crónica encontrado como un hallazgo no necesariamente relacionado con la hemorragia obstétrica.


Abstract OBJECTIVE: To determine and compare long-term creatinine clearance with baseline creatinine clearance in patients with obstetric hemorrhage. MATERIALS AND METHODS: Observational, longitudinal, retrospective, comparative and analytical study carried out in a series of patients with obstetric hemorrhage (loss ≥ 1000 mL) hospitalized in the intensive care unit. Creatinine clearance was calculated with the CKD-EPI formula at two time points: on admission to intensive care after the end of pregnancy complicated by hemorrhage (baseline measurement) and from their last recorded medical consultation (long-term measurement). Descriptive statistics and Student's t-test were used with SPSS version 20, p < 0.05 was considered significant. RESULTS: Forty-nine patients with mean age of 30.48 ± 6.06 years and 32.20 ± 8.24 weeks of pregnancy were studied. Cesarean section was performed in 39 of 49, 5 of 49 delivered, 4 of 49 required hysterotomy and only one required instrumental curettage. The mean estimated bleeding was 2744.89 ± 1474.65 mL. Creatinine clearance: initial measurement 159.09 ± 46.62 and long-term (22.27 ± 1.55 months later) 112.23 ± 30.91 mL of min of 1.73 m2 body surface area. The difference was significant (p = 0.002). On long-term measurement, chronic kidney disease was found in 1 of the 49 patients. CONCLUSIONS: Long-term creatinine clearance resulted lower, perhaps due to regression of gestational changes over time, but without significant functional impairment, except for one case with chronic kidney disease found as a finding not necessarily related to obstetric hemorrhage.

6.
An. Fac. Cienc. Méd. (Asunción) ; 53(3): 147-152, 20201201.
Article in Spanish | LILACS | ID: biblio-1177998

ABSTRACT

La función renal (FR) es medida por varios métodos. La más utilizada es el aclaramiento de creatinina (ClCr), que reflejaría, el filtrado glomerular (FG). Para su medición se recurre a la recolección de orina durante 24 horas o a la utilización de fórmulas, siendo la más utilizada, la ecuación CKD-EPI (Chronic kidney disease Epidemiology Collaboration). La disfunción renal se clasifica en 5 estadios. El estadio 5 (cuando el ClCr es igual o inferior a 15 ml/min), es cuando los pacientes están prontos a recibir tratamiento sustitutivo renal (TSR). La hemodiálisis (HD), es una técnica muy utilizada como TSR y normalmente es llevada a cabo 3 veces a la semana, por 4 horas cada una. Un paciente de 59 años, quién debido a la distancia entre su domicilio y el Centro de diálisis decide (consentimiento firmado), someterse a solo 2 sesiones de HD por semana. Al inicio del tratamiento, el paciente presentaba todos los datos clínicos y bioquímicos de la Enfermedad renal Crónica Avanzada, estadio 5 y un volumen diurético (VD) ≥ 1 litro/día. En caso de empeoramiento clínico y/o bioquímico, las sesiones de HD serían 3 veces por semana. Al año, los parámetros clínicos, bioquímicos y la función renal residual (FRR), permanecen óptimos. Si FRR (medido por el aclaramiento de urea (Kru) y el VD), declina serán necesarias 3 sesiones de HD, semanales. El mantenimiento de la FRR, está relacionado con la mortalidad y la HD incremental, al preservar mejor la FRR, mejora la sobrevida del paciente.


Several methods are useful to measure renal function (RF). In clinical practice, the creatinina cleareance (CrCl), is widely used, which approximately reflects the glomerular filtration rate (GFR). The 24 hs urine volume collection is required to measure CrCl, however, thanks different formulas we can have a precise CrCl value. The CKD-EPI (chronic kidney disease epidemiology collaboration), is the equation frequently used. According to glomerular filtration rate (GFR), the renal function has been classified in 5 stages. At advances stages (stage 5), (CrCl: 15 ml/min), the patient is faced to receive renal replacement therapy (RRT). Hemodialysis (HD) method is often used. It is carry out 3 times per week (4 hours each). A 59 years old male, due to the distance between the Capital City and his home, decided to receive HD only two times per week (signed consent). At the beginning of the treatment the patient presents all the clinical and biochemical data corresponding to Chronic Renal Failure stage 5. His diuretic volume (DV), ≥ 1 lt/day. In the case of RF deterioration reflected clinical and/or biochemically, the HD session would be 3 times a week. At year, presents adequate residual renal function (RRF) and clinics, biochemical parameters as well. If the RRF (measured by urea clareance (Kru) and the DV) decline, 3 sessions per week will be necessary. The RRF maintenance is related to mortality, therefore, its preservation thanks incremental HD, improve the patient survival.


Subject(s)
Renal Dialysis , Creatinine , Dialysis , Renal Insufficiency, Chronic , Kidney Failure, Chronic , Residence Characteristics , Epidemiology , Mortality
7.
Med. crít. (Col. Mex. Med. Crít.) ; 33(6): 298-304, Nov.-Dec. 2019. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1287147

ABSTRACT

Resumen: Introducción: A finales de la década de los cincuenta, el concepto de exceso de base (EB) fue introducido por Siggaard-Andersen como marcador sérico de los problemas estrictamente metabólicos. Hoy en día, la base (B) ha sido estandarizada con resultados más efectivos cuando utilizamos la base estándar (Becf) en la evaluación clínica. El lactato y la base estándar medidos al ingresar a la Unidad de Cuidados Intensivos (UCI) son de utilidad pronóstica en los pacientes críticamente enfermos. Decidimos medir el aclaramiento del déficit de base estándar en los pacientes con choque séptico en las 24 horas subsecuentes a partir del ingreso y evaluar su utilidad pronóstica para la mortalidad. Material y métodos: Estudio de cohorte, retrospectivo, descriptivo y analítico, que incluyó pacientes con diagnóstico de choque séptico según el tercer Consenso Internacional de Sepsis y Choque Séptico (sepsis-3) ingresados a la Unidad de Cuidados Intensivos (UCI) durante el periodo comprendido de mayo de 2015 a mayo de 2019. Los pacientes se asignaron al grupo < 11% o al grupo ≥ 11% según su porcentaje (%) de aclaramiento de déficit de base estándar a las 24 horas. Resultados: Se incluyeron 118 pacientes que cumplieron con los criterios de inclusión. Del total, 43 pacientes se asignaron al grupo de aclaramiento de déficit de base estándar < 11% y 75 pacientes al grupo de aclaramiento de déficit de base estándar ≥ 11%. En el grupo con aclaramiento < 11%, la mortalidad fue de 65.1% y de 36% para el grupo con aclaramiento ≥ 11% con p = < 0.05. Conclusión: El aclaramiento del déficit de base estándar < 11% a las 24 horas de ingreso a la Unidad de Cuidados Intensivos incrementa el riesgo de muerte en el choque séptico. El porcentaje de aclaramiento del déficit de base estándar es una excelente alternativa, pues su desempeño para predecir la mortalidad tiene una capacidad pronóstica similar a la del lactato.


Abstract: Introduction: The concept of base excess (BE) was introduced by Siggaard-Andersen in the late 1950s as a serum marker of strictly metabolic problems. Today the base (B) has been standardized with more effective results when we use the standard base (ecfB) in the clinical evaluation. Lactate and the standard base measured upon admission to the Intensive Care Unit (ICU) are of prognostic utility in critically ill patients. We decided to measure the standard base deficit clearance at 24 hours after admission in patients with septic shock and evaluate its prognostic utility for mortality. Material and methods: Cohort, retrospective, descriptive, analytical study that included patients with diagnosis of septic shock according to the third international consensus of sepsis and septic shock (sepsis-3) admitted to the ICU in the period from May 2015 to May 2019. Patients were assigned to belong to group < 11% or group ≥ 11% according to their percentage (%) of standard base deficit clearance at 24 hours. Results: 118 patients who met the inclusion criteria were included. Of the total, 43 patients were assigned to the standard base deficit clearance group < 11% and 75 patients to the standard base deficit clearance group ≥ 11%. In the group with clearance < 11% the mortality was 65.1 and 36% for the group with clearance ≥ 11% with p = < 0.05. Conclusion: Clearance the standard base deficit < 11% after 24 hours of admission to the ICU increases the risk of death in septic shock. The percentage of standard base deficit clearance is an excellent alternative, since its performance to predict mortality has a prognostic capacity similar to that of lactate.


Resumo: Introdução: O conceito de excesso de base (EB) foi introduzido por Siggaard-Andersen no final da década de 1950 como um marcador sérico de problemas estritamente metabólicos. Hoje a base (B) foi padronizada com resultados mais eficazes quando usamos a base padrão (Becf) na avaliação clínica. O lactato e a base padrão medidas na admissão na unidade de terapia intensiva (UTI) são de utilidade prognóstica em pacientes críticos. Decidimos medir a depuração do déficit de base padrão 24 horas após a internação em pacientes com choque séptico e avaliar sua utilidade prognóstica para a mortalidade. Material e métodos: Estudo de coorte, retrospectivo, descritivo, analítico que incluiu pacientes com diagnóstico de choque séptico de acordo com o terceiro consenso internacional de sepse e choque séptico (sepse-3) admitidos na UTI no período de maio de 2015 a maio de 2019. Os pacientes foram designados para pertencer ao grupo < 11% ou grupo ≥ 11%, de acordo com a porcentagem (%) de depuração do déficit de base às 24 horas. Resultados: Foram incluídos 118 pacientes que atenderam aos critérios de inclusão. Do total, 43 pacientes foram designados para o grupo de depuração do déficit de base padrão < 11% e 75 pacientes para o grupo de depuração do déficit de base padrão ≥ 11%. No grupo com depuração < 11% a mortalidade foi de 65.1% e 36% no grupo com depuração ≥ 11% com p = < 0.05. Conclusão: A depuração do déficit de base padrão < 11% após 24 horas de internação na UTI aumenta o risco de morte em choque séptico. A porcentagem de depuração do déficit de base padrão é uma excelente alternativa, uma vez que seu desempenho na predição da mortalidade possui capacidade prognóstica semelhante à do lactato.

8.
Medicina (B.Aires) ; 79(4): 303-314, ago. 2019. ilus, tab
Article in Spanish | LILACS | ID: biblio-1040528

ABSTRACT

Los canales de cloruros, de sodio, de bicarbonato y los de agua (aquaporinas) se coordinan para mantener la cubierta líquido superficial de las vías respiratorias, que es necesaria para el aclaramiento mucociliar. El mecanismo general para el transporte de electrolitos y agua depende principalmente de la expresión diferencial y distribución de los transportadores y bombas de iones. Los iones y el agua se mueven a través de las vía paracelular o transcelular. La ruta transcelular del transporte de electrolitos requiere un transporte activo (dependiente de ATP) o pasivo (siguiendo gradientes electroquímicos) de iones. La ruta paracelular es un proceso pasivo que está controlado, en última instancia, por los gradientes electroquímicos transepiteliales predominantes. La fibrosis quística es una enfermedad hereditaria que se produce por mutaciones en el gen que codifica la proteína reguladora de la conductibilidad transmembrana de la fibrosis quística (CFTR) que actúa como un canal de cloro y cumple funciones de hidratación del líquido periciliar y mantenimiento del pH luminal. La disfunción del canal de cloro en el epitelio respiratorio determina una alteración en las secreciones bronquiales, con aumento de su viscosidad y alteración de la depuración mucociliar y que asociado a procesos infecciosos puede conducir a daño pulmonar irreversible. La disfunción del CFTR, también se ha visto implicado en la patogénesis de la pancreatitis aguda, en la enfermedad pulmonar obstructiva crónica y la hiperreactividad en el asma. Existen fármacos que aprovechan los mecanismos fisiológicos en el transporte de iones, con un objetivo terapéutico.


The chloride channels, sodium and bicarbonate channels, and aquaporin water channels are coordinated to maintain the airway surface liquid that is necessary for mucociliary clearance. The general mechanism for the transport of electrolytes and fluids depends mainly on the differential expression and distribution of ion transporters and pumps. Ions and water move through the paracellular or transcellular pathways. The transcellular route of electrolyte transport requires an active transport (dependent on ATP) or passive (following electrochemical gradients) of ions. The paracellular pathway is a passive process that is ultimately controlled by the predominant transepithelial electrochemical gradients. Cystic fibrosis is a hereditary disease that is produced by mutations in the gene that encode cystic fibrosis transmembrane conductance regulatory protein (CFTR) that acts as a chloride channel and performs functions of hydration of periciliary fluid and maintenance of luminal pH. The dysfunction of the chlorine channel in the respiratory epithelium determines an alteration in the bronchial secretions, with an increase in its viscosity and alteration of the mucociliary clearance and that associated with infectious processes can lead to irreversible lung damage. CFTR dysfunction has also been implicated in the pathogenesis of acute pancreatitis, chronic obstructive pulmonary disease, and bronchial hyperreactivity in asthma. There are drugs that exploit physiological mechanisms in the transport of ions with a therapeutic objective.


Subject(s)
Humans , Biological Transport, Active/physiology , Mucociliary Clearance/physiology , Ion Transport/physiology , Chloride Channels/metabolism , Cystic Fibrosis Transmembrane Conductance Regulator/metabolism , Cystic Fibrosis/metabolism , Chloride Channels/physiology , Cystic Fibrosis Transmembrane Conductance Regulator/physiology , Cystic Fibrosis/physiopathology
9.
Metro cienc ; 26(1): 39-42, jun. 2018.
Article in Spanish | LILACS | ID: biblio-981567

ABSTRACT

Cuando hablamos del aclaramiento de lactato debemos conocer con claridad la complejidad del proceso, pues abarca todo el metabolismo del lactato desde su producción hasta su remoción: a este proceso se ha denominado equilibrio reversible de lactato. Este concepto que permitirá entender mejor los procesos dinámicos de su metabolismo no como producto final o de desecho (según, tradicionalmente, se nos ha hecho creer) sino, más bien, como un producto intermedio que ejerce funciones específicas y bien definidas que lo convierten no sólo en indicador de perfusión tisular sino en un indicador global del metabolismo celular.


When we talk about lactate clearance we have to be clear about the complexity of the process, since it involves the metabolism of lactate from its production to its removal what has been called reversible lactate equilibrium, this concept that will allow us to better understand the dynamic processes of its metabolism not as a final product or waste, as we have traditionally been led to believe, but rather as an intermediate product with specific and welldefined functions that make it not only an indicator of tissue perfusion, but a global indicator of metabolism cell


Subject(s)
Humans , Acid-Base Equilibrium , Metabolic Clearance Rate , Lactic Acid , Anaerobiosis , Energy Metabolism
10.
Rev. ADM ; 75(1): 9-25, ene.-feb. 2018. ilus, graf
Article in Spanish | LILACS | ID: biblio-906218

ABSTRACT

Este artículo de revisión ayudará a los odontólogos a mejorar su comprensión de los procedimientos de aclaramiento dental, tipos de aclaramientos, componentes activos, mecanismos de acción y sus efectos sobre las estructuras dentales, materiales de obturación y la adhesión. También se mostrará un nuevo sistema, el cual consiste en tres pasos denominados ABC que signifi ca Activate, Bleach and Condition (activación, blanqueamiento y acondicionamiento). Al realizar estas tres etapas se garantiza un tratamiento de aclaramiento muy efi caz, seguro y sobre todo sin dolor (AU)


This review article will help dentists to improve their understanding of dental clearance procedures, types of clearings, active components, mechanisms of action and their eff ects on dental structures, sealing materials and adhesion. It will also show a new system which consists of three steps called ABC that means Activate, Bleach, and Condition. Performing these three stages ensures a very effective, safe and especially painless clearance treatment (AU)


Subject(s)
Humans , Female , Adult , Esthetics, Dental , Hydrogen Peroxide , Tooth Bleaching , Composite Resins , Dental Bonding , Dental Enamel , Dental Leakage , Surface Properties , Tooth Discoloration
11.
Neumol. pediátr. (En línea) ; 11(1): 49-52, ene. 2016. ilus, graf
Article in Spanish | LILACS | ID: lil-789398

ABSTRACT

The rate of lung clearance is a measure of the ventilation inhomogeneity determined during multiple breath washout (MBW). Higher values of lung clearance index (LCI) indicate greater ventilation inhomogeneity. The test is performed during tidal breathing, needs little cooperation and coordination, and can be done in all age groups. Different tracer gases can be used; the most common are gas nitrogen as resident gas and sulfohexafluoride (SF6) as an exogenous gas.LCI has been used in various pediatric diseases, such as asthma, bronchopulmonary dysplasia and especially in patients with cystic fibrosis (CF), where high LCI values had been a more sensitive tool that spirometry to detect the early disease and bronchiectasis. It has also been used to monitor the progression of early lung disease, since the value of LCI in preschoolers predicted FEV1 in children of school age. Finally, in patients older than 6 years LCI has proven to be a useful tool to assess response to interventions in patients with normal lung function test. In conclusion the use of LCI is very promising in CF patients with early stages of the disease, and in the clinical monitoring of patients with CF. Its role in other respiratory diseases such as asthma, is still to be determined.


El índice de aclaramiento de pulmón (LCI) es una medida de la falta de homogeneidad de ventilación determinado durante el lavado pulmonar de múltiples respiraciones (MBW). Los valores más altos de LCI indican mayor inhomogeneidad de ventilación. La prueba se realiza durante respiración corriente y necesita poca cooperación y coordinación, por lo que se puede realizar en todos los grupos de edad. Pueden utilizarse diferentes gases trazadores; los más comunes son el nitrógeno como gas residente y sulfohexafluoride (SF6) como gas exógeno.LCI ha sido utilizado en diferentes enfermedades en pediatría, tales como asma, displasia broncopulmonar y especialmente fibrosis quística (FQ). En esta última los valores elevados de LCI son una herramienta más sensible quela espirometría para la detección de la enfermedad pulmonar precoz y bronquiectasias. También ha sido utilizado para monitorizar la progresión de la enfermedad pulmonar, ya que el valor de LCI en los niños en edad preescolar predice el VEF1 en edad escolar. Finalmente en pacientes mayores de 6 años LCI ha demostrado ser una herramienta útil para evaluarla respuesta a intervenciones en pacientes con función pulmonar normal. En conclusión el uso de LCI es muy prometedor en pacientes con FQ en etapa precoz de la enfermedad, su rolen el monitoreo clínico de los pacientes con FQ. En otras enfermedades de las vías respiratorias, como el asma, esto aún está por definirse.


Subject(s)
Humans , Child , Lung Diseases/physiopathology , Respiratory Function Tests/methods , Asthma/physiopathology , Bronchiolitis Obliterans/physiopathology , Cystic Fibrosis/physiopathology
12.
Rev. peru. biol. (Impr.) ; 22(3)dic. 2015.
Article in Spanish | LILACS-Express | LILACS, LIPECS | ID: biblio-1522418

ABSTRACT

Se determinó el efecto de la temperatura sobre la tasa de aclaramiento (TA), ingestión (TI) y consumo especifico de oxígeno (CEO) en individuos de Argopecten purpuratus (Lamarck, 1891) de distintos grupos de tallas. Las pruebas de TA y TI se realizaron a una concentración de Chaetoceros calcitrans de aproximadamente 1x10(6) cel.mL-1, se evaluaron dos temperaturas 17 y 22°C y se conformaron diferentes grupos de tallas promedio de 7.6 ± 0.265, 4.9 ± 0.058 y 3.7 ± 0.173 cm. En las pruebas de CEO los grupos de tallas promedio fueron 8.1 ± 0.351, 5.6 ± 0.058 y 4.3 ± 0.100 cm. Los resultados muestran un efecto significativo de la temperatura en la TA (L.h-1) y TI (cel.h-1 x 10(5)) sobre los individuos de mayor tamaño (7.6 ± 0.265 cm), observándose a 22°C un incremento promedio, respecto a 17°C, de hasta 250% para TA y 48% para TI. Además, se observó una relación directa del tamaño corporal con las TA y TI en ambas temperaturas. Se registró el efecto de la temperatura de 22°C sobre CEO en todos los grupos evaluados, con un incremento de 239.8, 165.3 y 183.4% para individuos de tallas de 8.1 ± 0.351, 5.6 ± 0.058 y 4.3 ± 0.100 respectivamente. Asimismo, los resultados muestran una relación indirecta del tamaño corporal con la CEO, en ambas temperaturas evaluadas.


The effect of temperature on the clearance rate (CR), ingestion rate (IR) and specific oxygen consumption (SOC) in individuals of Argopecten purpuratus at different size groups were determined. The CR and IR tests were performed at a concentration of approximately 1x10(6) cel.mlL-1 of Chaetoceros calcitrans, two temperatures 17 and 22 °C were evaluated and different groups of average size were formed of 7.6 ± 0.265, and 0.058 ± 4.9 3.7 ± 0.173 cm. In SOC test the average size groups were 8.1 ± 0.351, 0.058 ± 5.6 and 4.3 ± 0.100 cm. The results show a significant effect of temperature in CR (Lh-1) and IR (cel.h-1 x 10(5)) on the larger individuals (7.6 ± 0.265 cm), it was observed at 22 °C an average increase, about 17 °C, up to 250% to CR and 48% to IR. In addition, a direct relationship of body size with CR and IR in both temperatures was observed. The effect of temperature at 22 ° C on SOC in all groups was evaluated, with an increase of 239.8, 165.3 and 183.4% for size individuals of 8.1 ± 0.351, 0.058 ± 5.6 and 4.3 ± 0.100 respectively. Furthermore, in both evaluated temperatures, the results show an indirect relationship of body size with the SOC.

13.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1390066

ABSTRACT

Introducción: la identificación temprana de los pacientes con enfermedad renal permite realizar tratamientos que limitan la progresión del daño de este órgano y modificar los factores de riesgo asociados que contribuyen al aumento de su morbilidad. Objetivos: determinar la prevalencia de la Enfermedad renal crónica oculta (ERCO) en la población del Bañado Sur y sus factores de riesgo. Metodología: estudio descriptivo transversal realizado en hombres y mujeres mayores de 18 años de edad del Barrio Bañado Sur, Asunción, Paraguay. La toma de muestras se realizó en forma aleatoria, recorriendo casa por casa para determinar variables demográficas, clínicas y laboratoriales. Se determinó el filtrado glomerular aplicando la fórmula de MDRD-4 y se clasificaron los pacientes según el filtrado glomerular (FG), en estadios 1 a 5. Resultados: se estudiaron 75 personas con edad media 39 años±17 años, predominio del sexo femenino (66%). La creatinina sérica media fue 0,97 0,4 mg/dL, la glicemia media fue 109± 54 mg/dL, la FG media por MDRD-4 fue 90,32 ± 37,55 mL/min. Los pacientes se encontraban con distintos grados de función renal de acuerdo a los valores de FG. Se encontraron 34 personas en el estadio 1 (45%), 28 personas en el estadio 2 (37%), 10 personas en el estadio 3 (13%), 3 personas en el estadio 4 (4%) y ninguna persona en estadio 5. De ahí que 13 sujetos (17%) ya se hallaban con ERCO. Conclusión: la prevalencia de ERCO fue 17%. Es recomendable utilizar el filtrado glomerular por la fórmula MDRD-4 para evaluar la función renal en pacientes con factores de riesgo como obesidad, hipertensión arterial y diabetes mellitus.


Introduction: The early identification of renal disease patients allow treatments that limit the evolution of kidney damage and modify associated risk factors that contribute to the increase of morbidity. Objectives: To determine the prevalence of the occult chronic kidney disease (OCKD) in the population of the South Wetland (Bañado Sur) and their risk factors. Methodology: Cross-sectional descriptive study performed in men and women older than 18 years old in the South Wetland neighborhood of Asunción, Paraguay. Sample collection was made randomly, visiting house per house to determine demographic, clinical and laboratory variables. Glomerular filtration was determined using the MDRD-4 formula and patients were classified in 1 to 5 stages using the glomerular filtration rate (GFR). Results: Seventy people were studied, the mean age was 39±17 years old and there was a predominance of women (66%). The mean serum creatinine was 0.97±0.4 mg/dL, the mean glycemia was 109±54 mg/dL, and the mean GF by MDRD-4 was 90.32±37.55 mL/min. The patients were in different stages of renal function according to the GF. Thirty four people were in stage 1 (45%), 28 people in stage 2 (37%), 10 people in stage 3 (13%), 3 people in stage 4 (4%) and none was in stage 5. Thirteen (17%) subjects had already OCKD. Conclusion: The prevalence of OCKD was 17%. It is recommended to use glomerular filtration by MDRD-4 formula to evaluate the renal function in patients with risk factors such as obesity, arterial hypertension and diabetes mellitus.

14.
Rev. cuba. med ; 53(3): 254-265, jul.-set. 2014.
Article in Spanish | LILACS | ID: lil-726190

ABSTRACT

Introducción: la función renal puede ser estimada mediante la creatinina sérica o por fórmulas predictivas, de ahí que resulte importante evidenciar el valor de estos métodos. Objetivo: determinar la validez de la creatinina sérica y la fiabilidad de las fórmulas de estimación de la función renal en población litiásica cubana. Métodos: se realizó un estudio transversal. Se estudiaron 6 290 pacientes con litiasis urinarias que se realizaron estudio metabólico en el Instituto de Nefrología entre 2006 y 2011, 4 133 (65,7 por ciento) del sexo masculino y 2 157 (34,3 por ciento), del femenino. La información fue procesada utilizando el paquete estadístico SPSS 15.0. Para evaluar la capacidad diagnóstica de la creatinina sérica se emplearon curvas ROC y en el análisis de la fiabilidad de las fórmulas, diagramas de Bland y Altman. Resultados: las fórmulas con menor diferencia promedio con respecto al aclaramiento de creatinina fueron en la ERC (TFG ≤ 90 mL/min/1,73 m²): Cockcroft-Gault (3,81 mL/min/1,73 m²; DE 19,20 mL/min/1,73 m²), Salazar-Corcoran (-4,47 mL/min/1,73 m²; DE 18,40 mL/min/1,73 m²) y Levey (MDRD) (4,69 mL/min/1,73 m²; DE 13,75 mL/min/1,73 m²) y en IRC (TFG < 60 mL/min/1,73 m ²): Levey (MDRD) (1,39 mL/min/1,73 m²; DE 10,22 mL/min/1,73 m²), Jelliffe 1 973 (2,15 mL/min/1,73 m²; DE 10,87 mL/min/1,73 m²) y Salazar-Corcoran (-4,47 mL/min/1,73 m²; DE 18,40 mL/min/1,73 m²). La ecuación de Baracskay tuvo la mayor diferencia promedio (-9,67 mL/min/1,73m²; DE 17,04 mL/min/1,73 m²). El valor óptimo de corte para la creatinina sérica en ERC fue 1,07 mg/dLy 0,89 mg/dL, en hombres y mujeres, respectivamente. Conclusiones: los resultados de este estudio sugieren que la fiabilidad de las fórmulas predictivas es alta, con excepción de la de Baracskay, utilizada en ancianos...


Introduction: renal function may be estimated from serum creatinine or with prediction formulas. Hence the importance of being aware of the usefulness of these methods. Objective: determine the validity of serum creatinine and the reliability of renal function estimation formulas. Methods: a cross-sectional study was conducted of 6 290 patients with urolithiasis (4 133 male and 2 157 female -65.7% and 34.3 percent, respectively-) undergoing metabolic studies at the Institute of Nephrology from 2006 to 2011. Data were processed with the statistical software SPSS version 15.0. ROC curves were used to evaluate the diagnostic capacity of serum creatinine. Reliability of the formulas was assessed with Bland-Altman plots. Results: the formulas with the smallest mean difference with respect to creatinine clearance were the following: for ERC (GFR ≤ 90 mL/min/1.73 m²): Cockcroft-Gault (3.81 mL/min/1.73 m²; DE 19.20 mL/min/1.73 m²), Salazar-Corcoran (-4.47 mL/min/1.73 m²; DE 18.40 mL/min/1.73 m²) and Levey (MDRD) (4.69 mL/min/1.73 m²; DE 13.75 mL/min/1.73 m²) and for IRC (GFR < 60 mL/min/1.73 m ²): Levey (MDRD) (1.39 mL/min/1.73 m²; DE 10.22 mL/min/1.73 m²), Jelliffe 1 973 (2.15 mL/min/1.73 m²; DE 10.87 mL/min/1.73 m²) and Salazar-Corcoran (-4.47 mL/min/1.73 m²; DE 18.40 mL/min/1.73 m²). The Baracskay formula showed the greatest mean difference (-9.67 mL/min/1.73m²; DE 17.04 mL/min/1.73 m²). Optimal cutoff value for serum creatinine in ERC was 1.07 mg/dL and 0.89 mg/dL for men and women, respectively. Conclusions: results suggest that the reliability of prediction formulas is high, except for Baracskay's, which is used in elderly patients...


Subject(s)
Humans , Creatine/urine , Kidney , Urinary Bladder Calculi
15.
Rev. salud bosque ; 4(2): 7-18, 2014. tab
Article in Spanish | LILACS | ID: lil-772938

ABSTRACT

Introducción. El blanqueamiento dental es de los procedimientos más solicitados a los odontólogos. Desde los años 90 han aumentado las técnicas y presentaciones de los productos usados para este procedimiento. Por el aumento en la demanda del blanqueamiento dental, se puede encontrar gran número de estudios en la literatura, por lo cual es difícil sacar conclusiones válidas sobre la efectividad a largo plazo de las técnicas disponibles. Objetivo. El objetivo de esta revisión sistemática es determinar si el blanqueamiento dental es efectivo a largo plazo, cuál sistema de blanqueamiento es el más efectivo, cuánto perdura en el tiempo y cuáles son las variables que intervienen en el éxito. Materiales y métodos. Los artículos utilizados en esta revisión son ensayos clínicos aleatorizados, buscados electrónica y manualmente entre 1980 y el 2013, en diferentes bases de datos. Resultados. De 4.581 artículos encontrados, se seleccionaron 8 artículos para incluir en la revisión, ya que cumplían con los criterios establecidos. Después de seleccionar los artículos definitivos para la revisión, se hizo una evaluación metodológica de estos, por medio de la cual se encontró que el nivel de evidencia fue alto en tres artículos, medio en cuatro y bajo en uno. Conclusión. Teniendo en cuenta la buena ‘evidencia’ que se encontró, se concluye que: la efectividad del blanqueamiento a largo plazo no depende de la técnica del blanqueamiento empleada. El cambio de color registrado durante el blanqueamiento dental fue similar en todos los grupos evaluados. El blanqueamiento en casa, es un tratamiento efectivo. A pesar de que se mantienen los cambios de color logrados con el blanqueamiento, se presenta una recidiva de leve a moderada.


Introduction: Tooth whitening is one of the most requested treatments in dentistry; since the 90’s the techniques and product presentations used for this procedure have increased. Due to the rise in the demand for tooth whitening, a great number of studies can be found in the literature, for this reason it is hard to draw valid conclusions about long term effectiveness of the different techniques for tooth whitening available in the market. Aim: The objective of this systematic review was to determine the long term effectiveness of tooth whitening, which tooth whitening system is the most effective, how long it endures throughout time, and which variables are involved in its success. Methods: The studies used in this systematic review were randomized clinical trials searched electronically and manually in a period between 1980, and 2013, in different data bases. Results: out of 4.581 articles found, 8 were selected to be included, since they met the inclusion criteria. After choosing the articles to be included, a methodological assessment of them was done, 3 presented high evidence, 4, medium and 1 low. Conclusion: Taking into account the good evidence found it could be concluded that: long-term effectiveness of tooth whitening does not depend on the whitening technique used. The change in color registered during tooth whitening, was similar for all groups. At home tooth whitening is an effective treatment. Even though the changes in color obtained are maintained, a relapse in color from mild to moderate is observed.


Subject(s)
Tooth Bleaching Agents , Tooth Bleaching , Effectiveness
16.
Odontol. clín.-cient ; 12(1): 77-80, Jan.-Mar. 2013. ilus
Article in Spanish | LILACS | ID: lil-720304

ABSTRACT

El manejo de los pacientes con tinciones por tetraciclinas es un manejo complejo, según el grado de tinción que presenta cada paciente. En la atención clínica, se pueden presentar este tipo de situación y está en el profesional preparado para manejar adecuadamente estos casos. Se han descrito en la literatura varios tipos de alternativas de tratamiento, según la complejidad del caso. En el presente artículo se presenta una alternativa de tratamiento en la resolución de un caso clínico. El objetivo fue mejorar la estética de las piezas dentarias, realizando un procedimiento de blanqueamiento dental con cubetas. Los resultados fueron satisfactorios para el paciente, ya que en general se puede atenuar bastante las tinciones, volviendo al paciente la estética en su sonrisa. Se puede concluir que el manejo adecuado de los geles de blanqueamiento ofrece una alternativa eficaz en la resolución de este tipo de casos.


The management of patients with stains by tetracycline is complicated depending on the degree of stain that each patient presents when attending These situations may occur and the professional should be properly prepared to handle these cases. Several kinds of alternatives of treatment depending on the complexity of the case have been described in the literature. This article presents an option to treatment in a clinical case. The objective was to improve the teeth esthetic performing about a procedure of dental bleaching with buckets. The results were satisfactory for the patient because the stains were quite mitigated and this gave the patient an esthetic smile. It can be concluded that the proper handling of whitening or bleaching gels offer an effective alternative in the resolution of such cases.

17.
CES odontol ; 25(2): 54-62, jul.-dic. 2012.
Article in Spanish | LILACS | ID: lil-671093

ABSTRACT

Currently there is a significant increase the in demand for procedures associated with dental esthetics. Asa result, in recent years many systems have been developed for tooth bleaching through different forms ofapplication. Despite its widespread use, it has been argued that this process can alter not only the structure ofthe enamel surface, but can interfere with bonding procedures required to carry out orthodontic treatment.Different studies have showed that in patients receiving dental treatment clearance, adhesion processes arenot as efficient as those who did not.This article presents a literature review on the current state of tooth bleaching, and the relationship and / oreffect on orthodontic treatment when it is done before, during or after bleaching.


Actualmente se presenta un aumento importante de la demanda por procedimientos asociados a la estéticadental. A consecuencia de ello, en los últimos años se han desarrollado múltiples sistemas para realizar elaclaramiento dental por medio de diferentes formas de aplicación. A pesar de su amplio uso, se ha discutidoque dicho proceso puede alterar no solo la estructura de la superficie del esmalte, sino que puede interferiren los procedimientos de adhesión que se requieren para llevar a cabo un tratamiento de ortodoncia.Diferentes investigadores han realizado estudios que demuestran que, en los pacientes que han recibidotratamientos de aclaramiento dental, los procesos de adhesión no son tan eficientes como en aquellos queno lo recibieron.En este artículo, se presenta una revisión de literatura sobre el estado actual del aclaramiento dental, y la relacióny/o efecto que tiene en el tratamiento de ortodoncia, cuando éste se hace antes, durante o después del mismo.


Subject(s)
Humans , Dental Enamel , Resins, Synthetic , Tooth Bleaching , Dental Bonding
18.
Rev. Fac. Odontol. Univ. Antioq ; 23(2): 256-267, jun. 2012. graf, tab
Article in Spanish | LILACS | ID: lil-641191

ABSTRACT

Introducción: el objetivo de este estudio es identificar los efectos clínicos y microscópicos del uso del láser en el aclaramiento dental sobre dientes humanos vitales. Métodos: en este estudio experimental, la muestra correspondió a 11 pacientes entre 21 y 35 años, de los cuales se recolectaron 22 dientes premolares sanos, sin restauraciones, fracturas o defectos coronales, con exodoncia indicada pormotivos ortodóncicos. Se compararon los efectos de la aplicación del aclaramiento con GC TiON® (GC dental, Washington, USA), con LED/Láser Ultrablue IV y sin él (DMC Equipamentos São Paulo, Brasil). Los dientes se dividieron en tres grupos: grupo control (n = 2), grupo 1 (n = 10) se aplicó el GC TiON® y láser y grupo 2 (n = 10) se aplicó el GC TiON ® sin láser. Posterior al aclaramiento, los dientes seextrajeron y se conservaron en agua destilada. Se hizo toma de color antes y después de cada sesión de aclaramiento. Las alteraciones en la superficie vestibular de las muestras fueron analizadas con microscopia electrónica de barrido. Resultados: el 85% (17 casos) no mostraron ninguna alteración en el esmalte, el 10% (2 casos) presentó alteraciones leves y solo el 5% (1 caso) tuvo alteración moderada en esmalte. No existió gran diferencia en el cambio de color entre los grupos; de las 20 muestras, 6 llegaron al tono B1 en la primera sesión, 7 en la segunda sesión y 7 en la tercera sesión. Conclusiones: con la microscopia electrónica no se evidenciaron daños severos en la estructura dental. No se presentó diferencia significativa en el grado de aclaramiento dental.


Introduction: the objective of this study was to identify the clinical and morphological laser effects on human vital teeth during dental bleaching procedures. Methods: this experimental study included 11 patients ages 21 to 35, from whom 22 healthy premolarteeth, with no restorations, fractures or crown defects were collected. These premolar teeth were extracted because of orthodontic reasons. The effects of performing dental bleaching with GC TiON® (GC dental, Washington, USA), and with and without LED/Laser Ultrablue IV (DMC Equipments Sao Paulo, Brasil) were compared. The teeth were divided into three groups: control group (n = 2), group 1 (n = 10),using GC TiON® with laser, and group 2 (n = 10), using GC TiON® without laser. After extraction, the teeth were conserved in distilled water. Color monitoring was performed before and after each whitening session. Alterations on the buccal surface of the samples were analyzed by means of Scanning Electron Microscopy (SEM). Results: 85% of the teeth (17) did not show enamel alterations, 10% (2 teeth)presented mild alterations, and only 5% (1 tooth) suffered moderate enamel alterations. No significant color change difference occurred among the groups; out of the 20 samples, 6 of them reached tone B1 in the first session, 7 in the second session, and 7 more in the third one. Conclusions: Scanning Electron Microscopy did not reveal severe damage in dental structure. No significant difference in teeth whiteninglevel occurred.


Subject(s)
Humans , Hydrogen Peroxide , Tooth Bleaching
20.
Mem. Inst. Invest. Cienc. Salud (Impr.) ; 9(2): 35-42, dic. 2011. tab, graf
Article in Spanish | LILACS, BDNPAR | ID: lil-618665

ABSTRACT

La creatinina sérica y el aclaramiento de creatinina (ClCr) son los métodos mayoritariamente empleados como medida del Filtrado Glomerular (FG), procedimientos no exentos de problemas tanto preanalíticos como analíticos. En los últimos años se viene proponiendo la utilización de fórmulas predictivas del FG. Buscamos comprobar la correlación entre el método analítico y el estimado por la ecuación de MDRD-4. Se estudiaron retrospectivamente 89 pacientes, con un promedio de 51 ± 14 años; 31 varones y 58 mujeres. Aunque la media del FG estimada por la fórmula MDRD-4 fue de 66 ± 28.83 ml/min y la obtenida con la depuración de creatinina fue de 62±30.22ml/min. (p<0.05); se encontró una correlación positiva entre ambos métodos (r=0,796; p=0,001). En nuestra población la ecuación MDRD-4 presenta una buena equivalencia con el ClCr y podría utilizarse para evaluar la función renal en pacientes con riesgo de desarrollar enfermedad renal crónica (ERC).


Serum creatinine and creatinine clearance (CrCl) methods are mostly used as measures of glomerular filtration (GF) and are procedures that are not exempt from both pre-analytical and analytical problems. In recent years, it has been proposed the use of predictive formulas of GF. In this study, we sought to verify the correlation between the analytical method and the estimated by the MDRD-4 formula. Eighty nine patients were studied retrospectively, they had a mean age of 51±14 years and there were 31 males and 58 females. Though the mean GF estimated by the MRDR-4 formula was 66 ± 28.83 ml/min and the obtained by creatinine depuration was 62 ± 30.22ml/min. (p<0.05), a positive correlation between both methods was found (r=0.796; p=0.001). In our population, the MRDR-4 formula has a good equivalence with the CrCl and could be used to assess the renal function of patients at risk of developing chronic kidney disease (CKD).


Subject(s)
Creatinine , Glomerular Filtration Rate
SELECTION OF CITATIONS
SEARCH DETAIL