Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Rev. cient. odontol ; 3(1): 287-295, ene.-jun. 2015. ilus, tab, graf
Article in Spanish | LILACS, LIPECS | ID: biblio-1047612

ABSTRACT

OBJETIVO: Evaluar el efecto del ácido poliacrílico al 15% (APA) aplicado por 10 y 20 segundos (s) en la dentina humana sobre la resistencia de unión de los cementos resinosos autoadhesivos. METODOLOGÍA: Se dividieron aleatoriamente veintisiete terceras molares en nueve grupos Maxcem Elite control (ME1), Maxcem Elite más APA aplicado por 10s (ME2), Maxcem Elite más APA por 20s (ME3), BisCem control (BC1), BisCem más APA por 10s (BC2), BisCem más APA por 20s (BC3), RelyX U200 control (RU1), RelyX U200 más APA por 10s (RU2), RelyX U200 más APA por 20s (RU3). Se cementaron discos de resina sobre la dentina y las muestras fueron almacenadas en agua destilada por 24h, luego se seccionaron para obtener microbarras de un área transversal de 1mm2 (n=30 por grupo). RESULTADOS: Los especímenes fueron evaluados con la prueba de microtensión. Los valores de la media y de la desviación estándar para cada grupo fueron: ME1=10.17MPa (±1.73), ME2=18.62 (±1.60), ME3=22.92 (±2.13), BC1=8.17 (±1.31), BC2=14.56 (±1.94), BC3=17.52 (±1.92), RU1=13.71 (±1.70), RU2=22.91 (±2.26) y RU3=30.42 (±1.50). Estos valores fueron analizados con las pruebas ANOVA de un factor y HDS de Tukey mostrando diferencias estadísticamente significativas (p<0.001) entre todos los grupos. CONCLUSIÓN: El acondicionamiento de la dentina con ácido poliacrílico al 15% incrementa significativamente la resistencia de unión de los cementos resinosos autoadhesivos, obteniéndose mejor resistencia en la aplicación por 20 segundos. (AU)


PURPOSE: To evaluate the effect of 15% polyacrylic acid (PAA) for 10 and 20 seconds applied to human dentin on the bond strength of three self-adhesive resin cements. MATERIALS AND METHODS: Twenty seven third molars were randomly divided into nine groups: Maxcem Elite control (ME1), Maxcem Elite + PAA applied for 10s (ME2), Maxcem Elite + PPA for 20s (ME3), BisCem control (BC1), BisCem + PAA for 10s (BC2), BisCem + PAA for 20s (BC3), RelyX U200 control (RU1), RelyX U200 + PAA for 10s (RU2), RelyX U200 + PPA for 20s (RU3). Resin disc were luted to dentin; after 24h of storage in distilled water, the samples were sectioned for obtaining microbar specimens whit a cross-sectional area of 1mm2 (n=30 per group). Specimens were submitted to the microtensile bond strength test. RESULTS: The mean and standard deviation result of each group were: ME1 = 10.17MPa (± 1.73), ME2 = 18.62 (± 1.60), ME3 = 22.92 (± 2.13), BC1 = 8.17 (± 1.31), BC2 = 14.56 (± 1.94), BC3 = 17.52 (± 1.92), RU1 = 13.71 (± 1.70), RU2 = 22.91 (± 2.26) and RU3 = 30.42 (± 1.50). These values were analyzed by one-way ANOVA and Tukey HDS shown statistically significant differences (p < 0.001) among all groups. CONCLUSION: Dentin conditioning with 15% polyacrylic acid significantly increases the bond strength of the self-adhesive resin cements, obtaining better resistance in the application for 20 seconds. (AU)


Subject(s)
Humans , Tissue Conditioning, Dental , Adhesives , Resin Cements , Dentin
SELECTION OF CITATIONS
SEARCH DETAIL