ABSTRACT

Abstract Introduction Therapeutic ultrasound (TUS) is a widespread modality in physiotherapy, and the water bag technique is a coupling method employed in the presence of anatomical irregularities in the treatment area. The aim of the present study is to evaluate the acoustic attenuation of the water bag and its effectiveness as a TUS coupling agent. Methods The rated output powers (ROPs) of the TUS equipment were evaluated based on IEC 61689. Then, a radiation force balance was used to measure ROP with and without a water bag (latex and nitrile gloves filled with deionized water) between a TUS transducer and the cone-shaped target of the balance. Each experiment was performed five times for each nominal power (0.5, 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, and 7.0 W) and in the following configurations: without the water bag (A), with nitrile gloves and with (B) and without (C) a height controller, and latex gloves with (D) and without (E) height controller. ROPs obtained in different media were compared. Results The highest relative error of ROP was 16.72% for 0.5 W. Although the power values of the equipment were within the range recommended by IEC, there was a significant difference between the ROP values measured with A and with B, C and D. Conclusion As intensity differences below 0.5 W/cm2 are considered clinically not relevant, conditions A, B, C, D, or E can be used interchangeably.

2.
Article in English | IMSEAR | ID: sea-154399

ABSTRACT

Emerging evidence suggests that ultrasonography of lung is a fast, inexpensive, widely available bed-side diagnostic tool which is useful for quick and early diagnosis of respiratory diseases. It is useful in the differential diagnosis of pulmonary infiltrates and has good accuracy in identifying consolidation and alveolar-interstitial syndrome. This technique can also be useful in the immediate evaluation of patients with dyspnoea or acute respiratory failure in the respiratory intensive care unit and helps in monitoring treatment response. Ultrasonography of lung has also been found to be useful in the diagnosis of pulmonary embolism, traumatic lung contusion and lung consolidation as well. There is a need for developing specific guidelines for establishing the standards of training and education regarding lung ultrasonography in India.


Subject(s)
Early Diagnosis , Humans , India , Lung Diseases/diagnosis , Lung Diseases/diagnostic imaging , Pneumothorax/diagnostic imaging , Predictive Value of Tests , Pulmonary Atelectasis/diagnostic imaging , Respiratory Care Units , SENSITIVITY &
SELECTION OF CITATIONS
SEARCH DETAIL