1.
Chinese Journal of Radiological Medicine and Protection ; (12): 476-480, 2017.
Article in Chinese | WPRIM | ID: wpr-620996

ABSTRACT

Objective To optimize the exposure parameters and reduce the irradiation dose level in infants and young children during digital radiography (DR) chest radiography under the premise of satisfied image quality.Methods The thoracic thickness of 100 patients were measured.Determined the aluminum equivalent of the thoraxes of the infants and young children by comparing the grayscale value and the aluminum step wedge.Another 100 infants and young children of experimental exposure were performed with the aluminum step wedge as a phantom,under AEC control,kV was the only variant to explore the optimal exposure parameters with dose monitor simultaneously.At last,clinical validation was performed.Images quality was compared with x2 test.The radiation dose of two groups was compared with t test.Results The maximum,minimum,average thoracic thickness and their correspondent aluminum equivalent were 13.5 and 2.3 cm,8.0 and 1.4 cm,(10.6 ± 1.3) and 2.0 cm,respectively.The average thoracic thickness of experimental group was (10.1 ± 2.2) cm.The range of entrance surface dose was 0.068-0.056 mGy while the tube voltage range was 55-65 kV.The exposure index range was 0.60-0.74.The visual inspection of aluminum step wedge was from grades 8 to 11 with satisfying image quality at lower radiation.The infant chest X-ray photography exposure parameters formula have been optimized,that was kV =thoracic thickness (cm) × 2 + 38 (constant),mAs (0.8-1.0) with SID =100 cm,without filter grid.Compare to the conventional parameters,the image quality of new method had no significant differences (P > 0.05).The actual average entrance surface dose was (0.048 ± 0.007) mGy,lower than AEC group (0.066 ± 0.008) mGy.The difference was statistically significant (t =16.781,P < 0.001).Conclusions The optimized formula kV =thoracic thickness (cm) ×2 + 38(constant),mAs (0.8-1.0) with SID =100 cm was credible for lowering the radiation exposure with good image quality for clinical diagnosis.

2.
Restorative Dentistry & Endodontics ; : 146-153, 2013.
Article in English | WPRIM | ID: wpr-77360

ABSTRACT

OBJECTIVES: Aluminum step wedge (ASW) equivalent radiodensity (eRD) has been used to quantify restorative material's radiodensity. The aim of this study was to evaluate the effects of image acquisition control (IAC) of a digital X-ray system on the radiodensity quantification under different exposure time settings. MATERIALS AND METHODS: Three 1-mm thick restorative material samples with various opacities were prepared. Samples were radiographed alongside an ASW using one of three digital radiographic modes (linear mapping (L), nonlinear mapping (N), and nonlinear mapping and automatic exposure control activated (E)) under 3 exposure time settings (underexposure, normal-exposure, and overexposure). The ASW eRD of restorative materials, attenuation coefficients and contrasts of ASW, and the correlation coefficient of linear relationship between logarithms of gray-scale value and thicknesses of ASW were compared under 9 conditions. RESULTS: The ASW eRD measurements of restorative materials by three digital radiographic modes were statistically different (p = 0.049) but clinically similar. The relationship between logarithms of background corrected grey scale value and thickness of ASW was highly linear but attenuation coefficients and contrasts varied significantly among 3 radiographic modes. Varying exposure times did not affect ASW eRD significantly. CONCLUSIONS: Even though different digital radiographic modes induced large variation on attenuation of coefficient and contrast of ASW, E mode improved diagnostic quality of the image significantly under the under-exposure condition by improving contrasts, while maintaining ASW eRDs of restorative materials similar. Under the condition of this study, underexposure time may be acceptable clinically with digital X-ray system using automatic gain control that reduces radiation exposure for patient.


Subject(s)
Humans , Aluminum , Radiographic Image Enhancement
3.
Journal of Korean Academy of Conservative Dentistry ; : 188-197, 2010.
Article in Korean | WPRIM | ID: wpr-58042

ABSTRACT

The purpose of this study was to compare radiopacity and radiographic discriminability of various FRC-Posts. Six FRC-Posts were investigated ; 1) FRC Postec Plus (Ivoclar Vivadent AG, Schaan, Liechtenstein), 2) Snowlight (Carbotech, Lewis center, OH, USA), 3) Dentin Post (Komet Brasseler, Lamgo, Germany), 4) Rely-X Fiber Post (3M ESPE, St.paul, MN, USA), 5) D.T.-Light Post (BISCO, Schaumburg, IL,USA), 6) Luxapost (DMG, Hamburg, Germany) The radiographs of each post with a reference 1 mm / 2 mm aluminum step-wedge was taken using digital sensor. The optical density were calculated by gray value of 10 x 10 pixel and compared in mm Al equivalent at five points. Six maxillary incisors of similar radiopacity were used. Radiographs of posts in Mx. incisors of lingual side of dry mandible were taken. We showed radiographs and asked the questionnaire to 3 radiologists, 3 endodontists, 3 general practitioners. The questionnaire was comprised of choices of the highest, lowest radiopaque individual post and the choices of best discriminable post at apical, coronal area. The following results were obtained. 1. Each post system showed various radiopacity. 2. There was change of discriminability between each post and simulated specimens regardless of examiner. Although each post showed various radiopacity, the difference of radiopacity did not affect on discriminability.


Subject(s)
Humans , Acrylic Resins , Aluminum , Composite Resins , Dentin , General Practitioners , Incisor , Mandible , Polyurethanes , Resin Cements , Surveys and Questionnaires
4.
Journal of Korean Academy of Conservative Dentistry ; : 61-68, 2009.
Article in Korean | WPRIM | ID: wpr-44640

ABSTRACT

This study was performed to assess the radiopacity of a variety of root canal sealers according to the specification concerning root canal sealers. Ten materials including Tubli-Seal(TM), Kerr Pulp Canal Sealer(TM), AH 26(R), AH plus(R), AH plus jet(TM), Ad sea l(TM), Sealapex(TM), NOGENOL(TM), ZOB seal(TM), Epiphany(TM) and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film was performed at different voltage and exposure time. In the second part, ten specimens were radiographed simultaneously with an aluminum step wedges on the occlusal films under decided condition. The mean radiographic den sity values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions, the appropriate voltage and exposure time that meet the requirement density was 60 kVp at 0.2 s. 2. All of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards. 3. The radiopacity of materials increased as thickness of materials increased. 4. The mm Al value of each specimen at 1mm in thickness has a significant difference in the statistics. It suggests that root canal sealers have a sufficient radiopacity that meet the requirement.


Subject(s)
Aluminum , Dental Pulp Cavity , Dentin , Epoxy Resins , Root Canal Filling Materials
5.
Journal of Korean Academy of Conservative Dentistry ; : 107-114, 2008.
Article in Korean | WPRIM | ID: wpr-105061

ABSTRACT

This study was performed to assess the radiopacity of a variety of canal filling and retrograde root-end filling materials according to the specification concerning root canal obturation materials. Ten materials including Gutta-percha pellets, amalgam, Fuji II LC, Dyract(R) AP, Super EBA(R), IRM(R), AH 26(R), Sealapex(TM), Tubli-Seal(TM) and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film were performed at 60 kVp (0.2, 0.3, 0.4 s), 70 kVp (0.2, 0.3, 0.33 s) to decide appropriate voltage and exposure time. In the second part, ten specimens which are 5 mm in diameter and 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 mm in thickness, were fabricated from each material studied. The specimens were radiographed simultaneously with an aluminum step wedge under decided condition (60 kVp, 0.2 s). The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions including 0.2 s, 0.3 s, 0.4 s at 60 kVp and 0.2 s, 0.3 s, 0.33 s at 70 kVp, the appropriate voltage and exposure time that meet the requirement of density from 0.5 to 2.0 was 0.2 s at 60 kVp. 2. All of the materials in this study had greater radiopacity than the minimun level recommended by ISO No. 4049 standards. 3. Most of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards except for Fuji II LC and Dyract. It suggests that all experimental canal filling and retrograde root-end filling materials have a sufficient radiopacity that meet the requirement concerning root canal obturation materials except for Fuji II LC and Dyract.


Subject(s)
Aluminum , Compomers , Dentin , Glass Ionomer Cements , Gutta-Percha , Resins, Synthetic , Root Canal Obturation
6.
Journal of Korean Academy of Conservative Dentistry ; : 419-425, 2007.
Article in English | WPRIM | ID: wpr-67031

ABSTRACT

The aim of this study was to evaluate the radiopacity and cytotoxicity of three resin-based (AH 26, EZ fill and AD Seal), a zinc oxide-eugenol-based (ZOB Seal), and a calcium hydroxide-based (Sealapex) root canal sealers. Specimens, 10 mm in diameter and 1 mm in thickness, were radiographed simultaneously with an aluminum step wedge using occlusal films, according to ISO 6876/2001 standards. Radiographs were digitized, and the radiopacity of sealers was compared to the different thicknesses of the aluminum step wedge, using the Scion image software. Using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, the cytotoxicity of each material was determined in immortalized human periodontal ligament (IPDL) cells. The results demonstrated that EZ fill was the most radiopaque sealer, while Sealapex was the least radiopaque (p 0.05). These results indicate that resin-based root canal sealer is more biocompatible and has advantage in terms of radiopacity.


Subject(s)
Humans , Aluminum , Calcium , Cell Survival , Dental Pulp Cavity , Periodontal Ligament , Zinc
7.
Journal of Korean Academy of Oral and Maxillofacial Radiology ; : 283-297, 1999.
Article in Korean | WPRIM | ID: wpr-41604

ABSTRACT

PURPOSE: To compare radiographic images of Digora system and Ektaspeed Plus film obtained from normal adults. MATERIALS AND METHODS: Storage phosphor plate(SPP) was placed in a film holder behind Ektaspeed Plus film package without lead foil. The effect of film on SPP was studied in a separate in vitro experiment. Forty-seven sets of images were prepared for the evaluaton. The regions of interest(ROI) for evaluation were designated at seven sites including normal anatomical structures. The image quality for each ROI was evaluated on enhanced and unenhanced storage phosphor(SP) images and Ektaspeed Plus film. RESULTS: Two film-SPP configurations showed significantly different grey levels at each step of the aluminum step wedge(p<0.05). The contrasts were comparable. Enhanced SP images were significantly superior to unenhaned images and film in all anatomical sturctures(p<0.01). The differences between unenhanced SP images and film were significant(p<0.05) except root canal and cortical bone on alveolar crest. For anatomical items, there were statistically significant difference among five observers(p<0.05). CONCLUSIONS: The image quality of enhanced SP images were superior to Ektaspeed Plus film, and Digora system is potentially applicable to clinical diagnosis.


Subject(s)
Adult , Humans , Aluminum , Dental Pulp Cavity , Diagnosis , Radiography, Dental, Digital