Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Archives of Plastic Surgery ; : 303-310, 2019.
Article in English | WPRIM | ID: wpr-762850

ABSTRACT

BACKGROUND: Prosthetic hands with a myoelectric interface have recently received interest within the broader category of hand prostheses, but their high cost is a major barrier to use. Modern three-dimensional (3D) printing technology has enabled more widespread development and cost-effectiveness in the field of prostheses. The objective of the present study was to evaluate the clinical impact of a low-cost 3D-printed myoelectric-interface prosthetic hand on patients' daily life. METHODS: A prospective review of all upper-arm transradial amputation amputees who used 3D-printed myoelectric interface prostheses (Mark V) between January 2016 and August 2017 was conducted. The functional outcomes of prosthesis usage over a 3-month follow-up period were measured using a validated method (Orthotics Prosthetics User Survey–Upper Extremity Functional Status [OPUS-UEFS]). In addition, the correlation between the length of the amputated radius and changes in OPUS-UEFS scores was analyzed. RESULTS: Ten patients were included in the study. After use of the 3D-printed myoelectric single electromyography channel prosthesis for 3 months, the average OPUS-UEFS score significantly increased from 45.50 to 60.10. The Spearman correlation coefficient (r) of the correlation between radius length and OPUS-UEFS at the 3rd month of prosthetic use was 0.815. CONCLUSIONS: This low-cost 3D-printed myoelectric-interface prosthetic hand with a single reliable myoelectrical signal shows the potential to positively impact amputees' quality of life through daily usage. The emergence of a low-cost 3D-printed myoelectric prosthesis could lead to new market trends, with such a device gaining popularity via reduced production costs and increased market demand.


Subject(s)
Humans , Amputation, Surgical , Amputation Stumps , Amputees , Artificial Limbs , Electromyography , Extremities , Follow-Up Studies , Hand , Methods , Prospective Studies , Prostheses and Implants , Quality of Life , Radius
2.
Journal of the Korean Microsurgical Society ; : 51-56, 2011.
Article in English | WPRIM | ID: wpr-724773

ABSTRACT

During below knee amputation, the amputation stump must be covered with well-vascularized and sensate soft tissue. Many flaps can be used for this purpose, but available reconstructive options are limited. We performed reverse flow ALT flap elevation on two patients with below knee amputations to reconstruct defects in the stumps. The sizes of the defects in the stumps were 4x16 cm and 5x5 cm, respectively. The most distal portion of the defects were located 20 cm and 16 cm lateral to the knee joint in a curve, respectively. The size of the elevated flap was 5x18 cm for case 1 and 18x10 cm for case 2. The respective pivot points of the pedicles were 7 cm and 6 cm above the patella and the respective lengths of the pedicles were 17 cm and 16 cm. In both cases, venous congestion occurred on the second postoperative day and the flap distal to 10 cm or more from below the knee joint was necrotized at the second postoperative week. Surgeons should be cautious when using a reverse ALT flap to reconstruct a soft tissue defect located 10 cm or more distal from below the knee joint. Since a pedicle longer than 15 cm may develop partial necrosis of the flap, simultaneous application of antegrade venous drainage is recommended.


Subject(s)
Humans , Amputation, Surgical , Amputation Stumps , Drainage , Hyperemia , Knee , Knee Joint , Necrosis , Patella , Thigh
3.
Korean Journal of Dermatology ; : 1374-1376, 2006.
Article in Korean | WPRIM | ID: wpr-215673

ABSTRACT

Verrucous hyperplasia appears as multiple, warty, coalescent papules arising on the distal portion of amputation stump skin, yet it displays no histological evidence of viral warts. It occurs when the chronic pressure of a poor prosthetic fit disrupts vascular and lymphatic channels, subsequently causing chronic tissue edema. We report a case of 30 year old male, with 15 year history of wearing below-the-knee prosthesis, who presented with a verrucous papule that arose at his amputation site. Histopathological findings showed hyperkeratosis, acanthosis, superficial dermal edema and dilated thick vessles oriented vertical to the skin surface. Verrucous hyperplasia with lymphedema was diagnosed on the basis of clinical and histological findings.


Subject(s)
Adult , Humans , Male , Amputation Stumps , Amputation, Surgical , Edema , Hyperplasia , Leg , Lymphedema , Prostheses and Implants , Skin , Warts
4.
Korean Journal of Dermatology ; : 953-955, 2001.
Article in Korean | WPRIM | ID: wpr-149797

ABSTRACT

Verrucous hyperplasia shows multiple warty like lesion on the amputation stump, but the pathologic findings of viral verrucae has not been discovered. A verrucous plaque on the amputation stump of the right leg was found in 31-year-old man. He had suffered from a traumatic amputation of right leg since 8 years ago. A leg prosthesis had been worn since that time. Histopathologic findings shows hyperkeratosis, acanthosis, papillomatosis, superficial dermal edema and dilated thick-walled venules oriented vertical to the skin surface. Verrucous hyperplasia was diagnosed with lymphedema on the basis of clinical and histological findings.


Subject(s)
Adult , Humans , Amputation Stumps , Amputation, Surgical , Amputation, Traumatic , Artificial Limbs , Edema , Hyperplasia , Leg , Lymphedema , Papilloma , Skin , Venules , Warts
5.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 10-13, 1998.
Article in Chinese | WPRIM | ID: wpr-997195

ABSTRACT

@#The prosthesis fitting were discussed in this paper for 48 un-reoperation of 91 cases the non-ideal stump of the lower limb amputees hospitalized in the past six years. The author suggests that silicon socks,the supplementary hang band,a combinative use of the prosthesis and orthosis,adjustment aligment of the prosthesis provide a good method for prosthesis fitting of the non-ideal stump of the lower limbamputees. It was able to wearing a good prosthesis and bring the compensatory functions into full play.

SELECTION OF CITATIONS
SEARCH DETAIL