Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Bauru; s.n; 2017. 100 p. tab, ilus, graf.
Thesis in English | LILACS, BBO | ID: biblio-879563

ABSTRACT

The present study aimed to identify different concentrations of residual stress of surfaces of porcelain veneer (PV) fused to zirconia 3-unit fixed dental prostheses (FDPs) with even thickness and modified (lingual collar connected to proximal struts presenting 12 mm2 connector area) framework designs by nanoindentation method. Twenty-three FDPs replacing second premolar (PM) were fabricated and the cyclic loading was applied on twenty FDPs. Fractured, suspended and non-fatigued FDPs were selected and divided (n=3/each) into: 1) Fractured even thickness (ZrEvenF); 2) Suspended even thickness (ZrEvenS); 3) Fractured with modified framework (ZrModF); 4) Suspended with modified framework (ZrModS); 5) Non-fatigued even thickness (Control). Moreover, the control group surfaces could be divided (n=3/each) into: 6) Mesial PM abutment (MPMa); 7) Distal PM abutment (DPMa); 8) Buccal PM abutment (BPMa); 9) Lingual PM abutment (LPMa); 10) Mesial PM pontic (MPMp); 11) Distal PM pontic (DPMp); 12) Buccal PM pontic (BPMp); 13) Lingual PM pontic (LPMp); 14) Mesial molar abutment (MMa); 15) Distal molar abutment (DMa); 16) Buccal molar abutment (BMa); 17) Lingual molar abutment (LMa). The PV surfaces were nanoindented in regions of interest (ROI) 1, 2 and 3, which were 0.03 mm, 0.35 mm and 1.05 mm from outer PV surface surface towards the PV/framework interface, respectively. Each ROI received 5 nanoindentations with 10 µm of minimum separation loaded to a peak load 4 µN. The Linear Mixed Model test and Least Significant Difference (95%) were used. The statistical analysis among ZrEvenF, ZrEvenS, ZrModF, ZrModS, and Control groups showed differences (p=0.000) except for the comparison between ZrModS and Control group (p=0.371). Also, ROI 1, 2, and 3 were different (p<0.001) with higher residual stresses in outer PV regions relative to those closer to the framework. The comparison among crowns showed that pontic was different from premolar (p=0,001) and molar (p=0,007) abutments, always showing higher residual stress levels. When marginal ridges groups (MPMa, DPMa, MPMp, DPMp, MMa, DMa) were compared, the DMa group was different from DPMp (p=0,004) and MPMa (p=0,00) group, whereas MPMa was different among all groups. The residual stress of porcelain veneer FDPs was different between: fractured and suspended FDPs regardless of the framework design; ROI 1, 2 and 3; and pontic and abutment crowns. Moreover, the proximal areas presented the highest concentration of residual stress. (AU)


O presente estudo teve como objetivo identificar diferentes concentrações de tensão residual de superfícies da cerâmica de revestimento (CR) de próteses parciais fixas de zircônia de 3 elementos (PPFs) com desenho da infraestrutura de espessura mínima e modificada (cinta lingual conectada aos postes proximais com 12 mm2 de área de conector) pelo método de nanoindentação. Vinte e três PPFs repondo segundo premolar (PM) foram confeccionados e o carregamento dinâmico foi aplicado em vinte PPFs. As PPFs fraturadas, suspensas e não fadigadas foram selecionadas e divididas (n=3/cada) nos seguintes grupos: 1) Fraturadas com espessura mínima (ZrEvenF); 2) Suspensas com espessura mínima (ZrEvenS); 3) Fraturadas com infraestrutura modificada (ZrModF); 4) Suspensas com infraestrutura modificada (ZrModS); 5) Não fadigadas com espessura mínima (Controle). Além disso, as superfícies do grupo controle foram divididas (n=3/cada) nos seguintes grupos: 6) Mesial do pilar PM (MPMa); 7) Distal do pilar PM (DPMa); 8) Vestibular do pilar PM (BPMa); 9) Lingual do pilar PM (LPMa); 10) Mesial do pôntico PM (MPMp); 11) Distal do pôntico PM (DPMp); 12) Vestibular do pôntico PM (BPMp); 13) Lingual do pôntico PM (LPMp); 14) Mesial do pilar molar (MMa); 15) Distal do pilar molar (DMa); 16) Vestibular do pilar molar (BMa); 17) Lingual do pilar molar (LMa). As superfícies da CR foram nanoendentadas nas regiões de interesse (ROI) 1, 2 e 3, a qual a distância da superfície externa da CR no sentido da interface CR/infraestrutura era de 0,03 mm, 0,35 mm e 1,05 mm, respectivamente. Cada ROI recebeu 5 nanoendentações com espaço mínimo de 10 µm para carregar até 4 µN. O teste modelo linear misto com diferença estatística mínima (95%) foi executado usando os valores de dureza. A análise estatística entre os grupos ZrEvenF, ZrEvenS, ZrModF, ZrModS, e Control apresentou diferenças (p=0.000) exceto para a comparação entre os grupos ZrModS e Control (p=0.371). Também, ROI 1, 2 e 3 foram diferentes (p<0.001). A comparação entre coroas mostrou que o pôntico foi diferente dos pilares pré-molar (p=0,001) e molar (p=0,007), sempre apresentando os maiores níveis de tensão. Quando os grupos das cristas marginais (MPMa, DPMa, MPMp, DPMp, MMa, DMa) foram comparadas, o grupo DMa foi diferente dos grupos DPMp (p=0,004) and MPMa (p=0,00), enquanto que o grupo MPMa foi diferente de todos os grupos. A tensão residual da cerâmica de revestimento foi diferente entre: PPFs fraturadas e suspensas independente do desenho da infraestrutura; ROI 1, 2 e 3; e pônticos e pilares. Além disso, as áreas proximais apresentaram a maior concentração de tensão residual. (AU)


Subject(s)
Dental Porcelain/chemistry , Dental Prosthesis Design/methods , Denture, Partial, Fixed , Zirconium/chemistry , Dental Restoration Failure , Dental Stress Analysis , Hardness Tests , Materials Testing , Reproducibility of Results , Surface Properties , Tensile Strength , Time Factors
2.
Bauru; s.n; 2017. 86 p. tab, ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-880013

ABSTRACT

A expansão de maxila cirurgicamente assistida (EMCA) é a modalidade de tratamento que tem como objetivo romper as regiões de reforço maxilar permitindo seu movimento expansivo gradativamente. Tal movimento pode ser realizado às custas de aparelhos dento-suportado, dento-muco-suportado, implanto-suportados ou ósseo-suportado. Os efeitos produzidos pelo tratamento vão desde alterações esqueléticas (aumento da base, cavidade e do espaço aéreo nasais) até inclinações dentárias (principalmente nos dentes de suporte do aparelho expansor), dentre outras. O objetivo desta pesquisa foi avaliar, por meio do Método de Elementos Finitos (MEF), a distribuição das tensões produzidas pela EMCA nas estruturas maxilares utilizando-se aparelho expansor ósseo-suportado. Material e métodos: Foi confeccionado um modelo tridimensional de maxila para simulação da EMCA com osteotomia tipo LeFort I descendente sem degrau, com disjunção pterigomaxilar utilizando um modelo de aparelho ósseo-suportado para o teste com a simulação de abertura de 1mm. Os resultados mostraram maior abertura da maxila na região anterior de incisivos a pré-molar (1 mm) e em menor quantidade (0,6mm) na região de molares. A tensão máxima principal (TMXP) mostrou a concentração de tensões principalmente em toda face palatina da maxila de pré-molar ao túber maxilar. Pela face lateral, ficou mais evidente a TMXP nas região de osso alveolar posterior ao pré-molar, molares e túber, assim como na região de pilar zigomático acima da osteotomia. Pelo plano transversal foi possível observar a transmissão de tensões ao longo das estruturas ósseas mostrando pouca dissipação para as raízes do molar. Enquanto que as forças de compressão (Tensão Mínima Principal), evidenciadas pela tensão mínima principal, se manifestaram nas áreas de pilar zigomático e adjacentes as osteotomias, assim como na áreas de contato do apoio do aparelho com o osso palatino. Tensões de tração e compressão também foram evidenciadas na região de processo pterigoide. A análise de tensão de Von Mises mostrou que a parte que mais sofre estresse é a haste que liga o módulo do aparelho com a plataforma de apoio. Conclusão: Houve maior abertura da maxila na região anterior e as tensões resultantes de forças transmitidas ao osso alveolar dos dentes adjacentes ao aparelho, parecem não ser suficientes para deslocar os dentes.(AU)


Surgically assisted maxillary expansion (SARME) is the modality of treatment that aims to weaken the points of maxillary reinforcement allowing its gradual expansion. Such movement can be performed at the expense of dento-supported, dento-muco-supported, implanto-supported or bony-backed devices. The effects produced by the treatment range from skeletal changes (increase of nasal base, cavity and nasal air space) to dental inclinations (mainly in the supporting teeth of the expander apparatus), among others. The objective of the present research was to evaluate the distribution of stress produced by SARME in the maxillary structures using the bone-supported expander apparatus by the Finite Element Method (FEM). Material and methods: A three-dimensional hemi-maxilla model was simulated for SARME with a non-step descending LeFort I osteotomy with pterygomaxillary disjunction using a bone-supported device model for the 1mm aperture simulation test. The results showed a greater opening of the maxilla in the anterior region of the incisors to the premolar (1 mm) and smaller (0.6 mm) in the molar region. The principal maximal stress (TMXP) showed the concentration of the tension forces mainly in all the palatine face of the pre-molar maxilla to the maxillary tuft. Due to the lateral aspect, the TMXP was more evident in the posterior alveolar bone region, the molars and tuber, as well as in the epilating zygomatic region above the osteotomy. From the transversal plane, it was possible to observe the transmission of stress along the bony structures showing little dissipation for the roots of the molar. Meanwhile, the forces of compression (Principal Minimum Tension) evidenced by the principal minimal stress, were manifested in the areas of the zygomatic pillar adjacent to the osteotomies, as well as in the areas of contact of the support of the apparatus with the palatine bone. Tension and compression forces were also evidenced in the pterygoid process region. Von Mises' stress analysis showed that the most stressed part is the rod connecting the device module to the support platform. Conclusion: There was a greater opening of the maxilla in the anterior region and the resulting forces of tension transmitted to the alveolar bone of the teeth adjacent to the appliance did not seem to be sufficient to displace the teeth.(AU)


Subject(s)
Humans , Finite Element Analysis , Maxilla/physiopathology , Maxilla/surgery , Orthotic Devices/standards , Osteotomy, Le Fort/methods , Palatal Expansion Technique/instrumentation , Equipment Design , Reference Standards , Reference Values , Reproducibility of Results
3.
Braz. dent. sci ; 19(3): 88-93, 2016. ilus, tab
Article in English | LILACS, BBO | ID: biblio-830982

ABSTRACT

Objective: The aim of this pilot study was to perform in vitro analysis of the stress related to instrumentation of artificial root canals with Reciproc System by using the photoelasticity method. Material and Methods: Photoelastic models consisted of two epoxy resin blocks simulating root canals, which were attached with cyanoacrylate adhesive to a base and placed at the centre of a circular polariscope in a darkfield configuration. The Reciproc R25 instrument was mounted to a VDW motor and used in block 1 up to 12 mm (working length) and then the same instrument was used in block 2. The images were captured by video camera and analysed at the time of the fourth penetration. Isochromatic fringes were observed in the cervical, middle and apical thirds at mesial and distal regions of each block. Therefore, they were divided into cervical-mesial (CM), cervicaldistal (CD), middle-mesial (MM), middle-distal (MD), apical-mesial (AM) and apical-distal (AD). Results: In the first instrumentation, it was found that the greatest stress occurred at the middle-distal region (1.38), followed by middle-mesial (1.20), apicaldistal (1.20) and apical-mesial regions (1.20). In the second instrumentation, the greatest stress occurred at the middle-mesial (1.20), apical-distal (1.20), apical-mesial (1.20) and middle-distal regions (0.90). Conclusion: The greatest stress occurred in the middle and apical thirds during the first instrumentation. Reutilization caused less stress.


O objetivo deste estudo piloto foi realizar a análise in vitro do estresse relacionado a instrumentação de canais artificiais utilizando o sistema de instrumentação Reciproc por meio da fotoelasticidade. Material e Métodos: Modelos fotoelásticos de dois blocos de resina epóxi com um canal simulado foram fixados com adesivo de cianoacrilato sobre uma base no centro de um polariscope circular na configuração de campo escuro. O instrumento Reciproc R25 foi inserido no motor VDW e utilizado no bloco 1 até 12 mm (comprimento de trabalho) e, sem seguida, o mesmo instrumento foi utilizado no bloco 2. As imagens foram captadas pela câmara de vídeo e analisadas no tempo da quarta penetração. As franjas isocromáticas foram observadas nos terços cervical, médio e apical, em regiões mesial e distal de cada bloco. Sendo assim, divididos em: CM - cérvico-mesial, CD - cérvicodistal, MM - médio-mesial, MD - médio-distal, AM - apical-mesial e AD - apical-distal. Resultados: Na primeira utilização do instrumento, o maior estresse ocorreu na região médio-distal (1,38), seguido por médio-mesial (1,20), apical-distal (1,20) e apicalmesial (1,20). No segundo uso, o maior estresse ocorreu na região médio-mesial (1,20), apical-distal (1,20), apical-mesial (1,20) e médio-distal (0,90). Conclusão: O maior estresse ocorreu nos terços médio e apical na primeira utilização, sendo que a reutilização promoveu menos estresse.


Subject(s)
Dental Instruments , Dental Stress Analysis , Endodontics
4.
Bauru; s.n; 2015. 113 p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-794217

ABSTRACT

A longevidade das coroas cerâmicas depende, entre outros fatores, de sua adaptação ao pilar, bem como da distribuição das tensões nas mesmas. Não há um consenso sobre a melhor adaptação dos copings de zircônia feitos em CAD/CAM em relação aos métodos convencionais, podendo haver uma influência da contração de sinterização sobre esta. O presente estudo avaliou as alterações dimensionais decorrentes do processo de sinterização em três diferentes marcas comerciais de blocos de zircônia, relacionando-as com a adaptação de copings confeccionados por um sistema CAD/CAM, além de avaliar como a adaptação de tais copings poderia impactar na distribuição de tensões em coroas cerâmicas bi-camadas com estrutura de zircônia. A contração de sinterização das três marcas comerciais de zircônia foi obtida experimentalmente a partir da mensuração de espécimes geométricos. Trinta e seis copings de zircônia confeccionados por CAD/CAM foram divididos em três grupos (n=12): ZMAX a partir de blocos de IPS E.max ZirCad (Ivoclar Vivadent; Liechtenstein); ZYZ blocos de InCeram YZ (Vita Zahnfabrik; Alemanha) e; ZMC zircônia de manufatura controlada (Zirklein/Biodinâmica; Brasil). Os copings foram escaneados em micro-CT antes a após a sinterização para que as alterações dimensionais decorrentes do processo de sinterização fossem obtidas a partir da mensuração de cortes específicos. Os dados das alterações dimensionais obtidos para os espécimes geométricos e para os copings foram confrontados com as taxas de contração de sinterização informadas pelos fabricantes dos blocos de zircônia. Os copings sinterizados foram assentados sobre um pilar de zircônia e levados ao micro-CT para averiguação da adaptação interna e marginal dos mesmos. As mensurações foram realizadas pelo software ImageJ em 33 pontos diferentes. Os dados da adaptação possibilitaram a comparação estatística (p0,05) entre marcas comerciais e locais de mensuração, bem como a comparação entre a adaptação...


The longevity of ceramic crowns depends, among other factors, on its fit and the stress distribution. There is no consensus regarding the better fitting of zirconia CAD/CAM made crowns over conventional methods and may be an influence of zirconia sintering shrinkage on the abutment/coping spacing. This study aimed at evaluating the dimensional changes from sintering process of three zirconia blocks trademarks, relating them to the fit of CAD / CAM made zirconia copings, and to evaluate how the fit of such copings could impact on the stress distribution in bilayered Y-TZP based ceramic crowns. The sintering shrinkage of the three trademarks of zirconia was obtained experimentally from the measurement of geometric specimens. Thirty-six zirconia copings made by CAD / CAM were equally divided into three groups (n = 12): ZMAX - from blocks of IPS e.max ZirCAD (Ivoclar Vivadent, Liechtenstein); ZYZ - InCeram YZ blocks (Vita Zahnfabrik, Germany) and; ZMC - controlled manufacturing zirconia (Zirklein/Biodinamica, Brazil). The copings were scanned in micro-CT before and after the sintering so that dimensional changes from the sintering process were obtained from measurements taken from specific slices. Data from dimensional changes obtained for the geometric specimens and for the copings were faced with the sintering shrinkage rates reported by the manufacturers of zirconia blanks. The sintered copings were settled on a zirconia abutment and taken to the micro-CT scanner to evaluate its marginal and internal fit. Thirty three different points were measured using the Image J software. The data enabled the statistical comparison (p 0,05) between trademarks and measurement sites, as well as the comparison between the fit obtained experimentally with that stipulated by the CAD / CAM software. The micro-CT images of copings with smaller and larger cement space were used to build finite element models to evaluate stress distribution as a function of the abutment...


Subject(s)
Humans , Computer-Aided Design , Crowns , Ceramics/chemistry , Dental Prosthesis Design/methods , Zirconium/chemistry , Analysis of Variance , Dental Marginal Adaptation , Hot Temperature , Materials Testing , Reference Values , Tensile Strength , Tomography, X-Ray Computed
5.
Bauru; s.n; 2015. 113 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867423

ABSTRACT

A longevidade das coroas cerâmicas depende, entre outros fatores, de sua adaptação ao pilar, bem como da distribuição das tensões nas mesmas. Não há um consenso sobre a melhor adaptação dos copings de zircônia feitos em CAD/CAM em relação aos métodos convencionais, podendo haver uma influência da contração de sinterização sobre esta. O presente estudo avaliou as alterações dimensionais decorrentes do processo de sinterização em três diferentes marcas comerciais de blocos de zircônia, relacionando-as com a adaptação de copings confeccionados por um sistema CAD/CAM, além de avaliar como a adaptação de tais copings poderia impactar na distribuição de tensões em coroas cerâmicas bi-camadas com estrutura de zircônia. A contração de sinterização das três marcas comerciais de zircônia foi obtida experimentalmente a partir da mensuração de espécimes geométricos. Trinta e seis copings de zircônia confeccionados por CAD/CAM foram divididos em três grupos (n=12): ZMAX a partir de blocos de IPS E.max ZirCad (Ivoclar Vivadent; Liechtenstein); ZYZ blocos de InCeram YZ (Vita Zahnfabrik; Alemanha) e; ZMC zircônia de manufatura controlada (Zirklein/Biodinâmica; Brasil). Os copings foram escaneados em micro-CT antes a após a sinterização para que as alterações dimensionais decorrentes do processo de sinterização fossem obtidas a partir da mensuração de cortes específicos. Os dados das alterações dimensionais obtidos para os espécimes geométricos e para os copings foram confrontados com as taxas de contração de sinterização informadas pelos fabricantes dos blocos de zircônia. Os copings sinterizados foram assentados sobre um pilar de zircônia e levados ao micro-CT para averiguação da adaptação interna e marginal dos mesmos. As mensurações foram realizadas pelo software ImageJ em 33 pontos diferentes. Os dados da adaptação possibilitaram a comparação estatística (p0,05) entre marcas comerciais e locais de mensuração, bem como a comparação entre a adaptação...


The longevity of ceramic crowns depends, among other factors, on its fit and the stress distribution. There is no consensus regarding the better fitting of zirconia CAD/CAM made crowns over conventional methods and may be an influence of zirconia sintering shrinkage on the abutment/coping spacing. This study aimed at evaluating the dimensional changes from sintering process of three zirconia blocks trademarks, relating them to the fit of CAD / CAM made zirconia copings, and to evaluate how the fit of such copings could impact on the stress distribution in bilayered Y-TZP based ceramic crowns. The sintering shrinkage of the three trademarks of zirconia was obtained experimentally from the measurement of geometric specimens. Thirty-six zirconia copings made by CAD / CAM were equally divided into three groups (n = 12): ZMAX - from blocks of IPS e.max ZirCAD (Ivoclar Vivadent, Liechtenstein); ZYZ - InCeram YZ blocks (Vita Zahnfabrik, Germany) and; ZMC - controlled manufacturing zirconia (Zirklein/Biodinamica, Brazil). The copings were scanned in micro-CT before and after the sintering so that dimensional changes from the sintering process were obtained from measurements taken from specific slices. Data from dimensional changes obtained for the geometric specimens and for the copings were faced with the sintering shrinkage rates reported by the manufacturers of zirconia blanks. The sintered copings were settled on a zirconia abutment and taken to the micro-CT scanner to evaluate its marginal and internal fit. Thirty three different points were measured using the Image J software. The data enabled the statistical comparison (p 0,05) between trademarks and measurement sites, as well as the comparison between the fit obtained experimentally with that stipulated by the CAD / CAM software. The micro-CT images of copings with smaller and larger cement space were used to build finite element models to evaluate stress distribution as a function of the abutment...


Subject(s)
Computer-Aided Design , Crowns , Ceramics/chemistry , Dental Prosthesis Design/methods , Zirconium/chemistry , Analysis of Variance , Dental Marginal Adaptation , Hot Temperature , Materials Testing , Reference Values , Tensile Strength , Tomography, X-Ray Computed
6.
Ortho Sci., Orthod. sci. pract ; 8(32): 471-478, 2015. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-852864

ABSTRACT

A verticalização de molares inferiores é indicada quando ocorre inclinação mesial dos segundos molares atribuída à ausência do primeiro molar. Existem inúmeras metodologias para realização de tal movimento. O objetivo do estudo foi analisar e comparar in vitro, por meio de fotoelasticidade a distribuição de tensões nos segundos molares inferiores geradas por diferentes métodos de verticalização com aplicação de diferentes cargas. Foi avaliado um modelo confeccionado em resina flexível com a mecânica de cantiléver. Foram utilizadas forças de 50 gf, 100 gf, 150 gf, 200 gf, 250 gf e 300 gf. As regiões do segundo molar selecionadas para avaliação foram: mesial da raiz cervical, apical da raiz mesial, cervical da raiz distal e apical da raiz distal. A resultante das forças aplicadas foi aferida por meio da quantificação das franjas isocromáticas. Os valores de franjas foram descritos com uso de média e desvio padrão e verificada a concordância/reprodutibilidade entre as avaliações com uso do coeficiente de correlação intraclasse com os respectivos intervalos com 95% de confiança e calculadas as medidas de repetibilidade. Utilizando-se o cantiléver, as maiores tensões localizaram-se na região cervical mesial, seguidas de apical da raiz mesial e região cervical distal. Não foram detectadas tensões na apical da raiz distal. A aplicação de forças acima de 100 gf apresentou grandes áreas de tensões nas regiões cervical e apical da raiz mesial.


Lower molars uprighting is indicated when mesial inclination of second molars occurs due to lack of first molars. There are many methodologies to perform such movement. The aim of this study was to analyze and compare in vitro, by means of photoelasticity, the stress distribution in lower second molars generated by different uprighting methods, with application of diferrent loads. It was assessed one model manufactured with flexible resin with cantilever mechanics. The loads used were 50gf, 100gf, 150gf, 200gf, 250gf, 300gf. The second molar areas selected for the assessment were the mesial of the cervical root, apical of the mesial root, cervical of the distal root and apical of the distal root. The resultant of forces applied was measured by quantifying isochromatic fringes. The fringe values were described using the mean and the standard deviation values and the agreement/reproducibility among the assessments were verified applying the intraclass correlation coefficient in the respective intervals with 95% confidence. Repeatability measures were calculated. Using cantilever, the highest strains were found in the mesial-cervical area, followed by the apical area of the mesial root and the distal-cervical area. In the apical area of the distal root strain was not found. The application of forces above 100gf showed large areas of tension in the cervical and apical regions of the mesial root.


Subject(s)
Dental Stress Analysis , Elasticity , Tooth Movement Techniques
7.
RPG, Rev. Pós-Grad ; 16(4): 188-193, out.-dez. 2009. tab, graf, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-855247

ABSTRACT

A proposta deste trabalho foi avaliar a influência da ciclagem mecânica na resistência de união de uma resina composta associada a um sistema adesivo convencional e um autocondicionante à dentina humana hígida por meio de teste de microtração. Para o estudo, foram utilizados 40 terceiros molares humanos hígidos, nos quais as faces oclusais foram lixadas até a obtenção de uma superfície plana com exposição do tecido dentinário. Os dentes foram divididos, aleatoriamente, em quatro grupos (n = 10) de acordo com o sistema adesivo utilizado e a realização ou não da ciclagem mecânica. Blocos de resina composta Z-250 foram confeccionados nas superfícies dentinárias após aplicação do sistema adesivo correspondente. Após esse passo, os espécimes de dois grupos passaram por ciclagem mecânica enquanto outros dois grupos ficaram armazenados em água destilada, mantidos em estufa à 37˚C até o momento do recorte dos espécimes para o teste de microtração. Os corpos de prova foram seccionados em planos perpendiculares à area de união para obtenção de espécimes com área de secção transversal aproximada de 1,0 mm2, que foram tracionados, em máquina de ensaios universal, à velocidade de 0,5 mm/minuto.


Os resultados de resistência de união foram analisados usando o teste estatístico análise de variância, e os modos de fratura foram avaliados em lupa estereoscópica (25 vezes). Não foram encontradas diferenças estatísticas entre os grupos (p < 0,05). Pôde-se concluir que não houve influência da ciclagem mecânica nos valores de resistência de união da resina composta associada a ambos os sistemas adesivos utilizados


Subject(s)
Humans , Dental Materials , Dental Stress Analysis , Dentin-Bonding Agents , Dental Enamel , Dentin , Esthetics, Dental , Smiling
8.
RFO UPF ; 14(1): 47-50, jan.-abr. 2009. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-516899

ABSTRACT

A indução de tensões ao implante e ao tecido ósseo peri-implantar pode ser responsável pela reabsorção tecidual e pela perda do implante. Próteses com o mínimo desajuste marginal são desejadas, acreditando-se na geração de menores valores de tensão às fixações .No entanto, não se tem certeza desta correlação, uma vez que a literatura não apresenta resultados confiáveis que venham a elucidar tal aspecto. Assim, o objetivo deste trabalho foi verificar se existe correlação entre os valores de desajuste marginal e de tensão gerados às fixações pelo parafusamento de infraestruturas implanto-retidas. Foram obtidas dez infraestruturas em titânio fundido, utilizando-se matriz metálica contendo dois implantes conectados a pilares cônicos para construções múltiplas. As infraestruturas foram aleatoriamente avaliadas quanto aos desajustes marginais mediante o teste do parafuso único e observação em microscópio ótico(120X). As tensões nas fixações foram avaliadas por extensometria. A média de desajuste marginal foi 118,07(58,61) μm e a média de tensão, 580,06 (253,93) gf.O teste de Pearson foi utilizado, mostrando não haver correlação entre desajuste marginal e tensão (-0,072),com p = 0,842. A presença e a intensidade do desajuste marginal, por si só, não são indicadores seguros no prognóstico da geração de tensões às fixações


Subject(s)
Dental Prosthesis , Dental Implants , Tensile Strength
9.
Araçatuba; s.n; 2009. 52 p. ilus.
Thesis in Portuguese | LILACS, BBO | ID: lil-671253

ABSTRACT

Objetivo: O propósito deste estudo foi avaliar o padrão de tensão produzido por overdentures implanto-retidas com 3 diferentes sistemas de retenção e prótese fixa tipo protocolo de Branemark, através do método da fotoelasticidade. Método: O modelo mandibular foi confeccionado em resina fotoelástica PL-2 contendo 4 implantes 3.75x10mm, posicionados na área interforaminal. Foram avaliadas 4 situações clínicas: A- Overdenture com 3 attachments clip sobre barra; B- Overdenture com 2 attachments Era em cantilever aos últimos implantes e 1 clip anterior; C- Overdenture com 3 attachments O’ring sobre barra e DPrótese total fixa tipo protocolo de Branemark. Forças oclusais verticais de 100N foram aplicadas entre os incisivos centrais e unilateralmente nos segundos premolares direito e esquerdo e segundos molares direito e esquerdo para todos os sistemas. Na prótese protocolo foram aplicadas cargas verticais nos primeiros molares a fim de permitir análise da extensão do cantilever. As tensões desenvolvidas nas estruturas de suporte foram monitoradas fotoelasticamente e registradas fotograficamente. Resultados: No carregamento anterior, houve alta concentração de stress nos implantes medianos na situação A, principalmente na região apical. O carregamento no premolar gerou alto stress no implante ipsilateral à aplicação da carga com maior intensidade para a prótese protocolo e situação A. No carregamento do molar, a overdenture com 3 o’ring distribuiu o stress de forma mais uniforme sobre o rebordo alveolar, com menor sobrecarga ao implante distal. O aumento do cantilever na prótese protocolo causou grande stress ao último implante e tração no implante mediano. Todas as situações avaliadas demonstraram baixa transferência de stress ao nível do pescoço dos implantes contralaterais à aplicação da carga. Conclusão: As forças verticais aplicadas na overdenture com 3 clip e prótese protocolo geraram um imediato padrão de stress de grande concentração e magnitude sobre o...


Objective: The purpose of this study was to evaluate of stress patterns produced by mandibular implant overdentures with three different attachment systems and fixed implant prosthesis, through the photoelastic method. Method: A mandibular model was fabricated PL-2 photoelastic resin having 4 screw-type implants (3.75 × 10 mm) embedded in the parasymphyseal area. Four clinical situations were evaluated: A - Overdenture with 3 plastic Hader clips on bar; B - Overdenture with 2 ERA attachment was in cantilever to the terminal implant and 1 anterior Hader clip; C - Overdenture with 3 ball/O-ring attachment on bar and D - implant-supported fixed partial denture (FPD). Vertical occlusal forces from 100 N were applied between of central incisor and unilaterally to the right and left second premolars and second molars for all the designs. In FPD were applied vertical loads in the first molars in order to allow analysis of the cantilever extension. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. Results: Anterior loading, there was high stress concentration in medium implant in the situation A, mainly apical area. The premolar loading generated high stress to the ipsilateral implants with larger intensity from the FPD and situation A. The molar loading, the overdenture with 3 ball/O-ring attachment away the caused more uniform stress distribution in the posterior edentulous ridge with less overload in the terminal implant. The FPD cantilever increase caused high stress to the terminal implant and traction to the medium implant. All the situations demonstrated a low stress transfer at the level of the contralateral implants neck. Conclusion: Vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on ipsilateral implants while the ball/O-ring attachments transferred minimal stress to implants. The clinical implication of the...


Subject(s)
Dental Implantation , Dental Prosthesis , Dental Prosthesis, Implant-Supported , Dental Stress Analysis
10.
Araçatuba; s.n; 2009. 52 p. ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-866155

ABSTRACT

Objetivo: O propósito deste estudo foi avaliar o padrão de tensão produzido por overdentures implanto-retidas com 3 diferentes sistemas de retenção e prótese fixa tipo protocolo de Branemark, através do método da fotoelasticidade. Método: O modelo mandibular foi confeccionado em resina fotoelástica PL-2 contendo 4 implantes 3.75x10mm, posicionados na área interforaminal. Foram avaliadas 4 situações clínicas: A- Overdenture com 3 attachments clip sobre barra; B- Overdenture com 2 attachments Era em cantilever aos últimos implantes e 1 clip anterior; C- Overdenture com 3 attachments O’ring sobre barra e DPrótese total fixa tipo protocolo de Branemark. Forças oclusais verticais de 100N foram aplicadas entre os incisivos centrais e unilateralmente nos segundos premolares direito e esquerdo e segundos molares direito e esquerdo para todos os sistemas. Na prótese protocolo foram aplicadas cargas verticais nos primeiros molares a fim de permitir análise da extensão do cantilever. As tensões desenvolvidas nas estruturas de suporte foram monitoradas fotoelasticamente e registradas fotograficamente. Resultados: No carregamento anterior, houve alta concentração de stress nos implantes medianos na situação A, principalmente na região apical. O carregamento no premolar gerou alto stress no implante ipsilateral à aplicação da carga com maior intensidade para a prótese protocolo e situação A. No carregamento do molar, a overdenture com 3 o’ring distribuiu o stress de forma mais uniforme sobre o rebordo alveolar, com menor sobrecarga ao implante distal. O aumento do cantilever na prótese protocolo causou grande stress ao último implante e tração no implante mediano. Todas as situações avaliadas demonstraram baixa transferência de stress ao nível do pescoço dos implantes contralaterais à aplicação da carga. Conclusão: As forças verticais aplicadas na overdenture com 3 clip e prótese protocolo geraram um imediato padrão de stress de grande concentração e magnitude sobre o...


Objective: The purpose of this study was to evaluate of stress patterns produced by mandibular implant overdentures with three different attachment systems and fixed implant prosthesis, through the photoelastic method. Method: A mandibular model was fabricated PL-2 photoelastic resin having 4 screw-type implants (3.75 × 10 mm) embedded in the parasymphyseal area. Four clinical situations were evaluated: A - Overdenture with 3 plastic Hader clips on bar; B - Overdenture with 2 ERA attachment was in cantilever to the terminal implant and 1 anterior Hader clip; C - Overdenture with 3 ball/O-ring attachment on bar and D - implant-supported fixed partial denture (FPD). Vertical occlusal forces from 100 N were applied between of central incisor and unilaterally to the right and left second premolars and second molars for all the designs. In FPD were applied vertical loads in the first molars in order to allow analysis of the cantilever extension. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. Results: Anterior loading, there was high stress concentration in medium implant in the situation A, mainly apical area. The premolar loading generated high stress to the ipsilateral implants with larger intensity from the FPD and situation A. The molar loading, the overdenture with 3 ball/O-ring attachment away the caused more uniform stress distribution in the posterior edentulous ridge with less overload in the terminal implant. The FPD cantilever increase caused high stress to the terminal implant and traction to the medium implant. All the situations demonstrated a low stress transfer at the level of the contralateral implants neck. Conclusion: Vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on ipsilateral implants while the ball/O-ring attachments transferred minimal stress to implants. The clinical implication of the...


Subject(s)
Dental Prosthesis , Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Dental Implants
11.
Rev. Fac. Odontol. Porto Alegre ; 49(1): 31-33, 2008. tab
Article in Portuguese | LILACS, BBO | ID: lil-563454

ABSTRACT

O presente estudo avaliou três diferentes marcas comerciais de compósitos quanto à fenda resultante da contração de polimerização: Esthet-X (Dentsply); Filtek Z350 (3MESPE); Concept (Vigodent) todos na cor A3. Os compósitos foram inseridos numa matriz metálica com 7mm de diâmetro interno e 2mm de altura, sendo prensados entre 2 placas de vidro e fotopolimerizados por 40 segundos em uma das superfícies com aparelho de luz halógena XL 3000 (3M/ESPE) a 500 +/- 10 mW/cm2. Após foram polidos em politriz, metalizados em ouro e levados para análise da fenda resultante da contração de polimerização em um microscópio eletrônico de varredura (Philips XL30). Foram feitas 4 medições para cada corpo de prova em áreas correspondentes a 3, 6, 9 e 12 horas. Os resultados foram submetidos à análise de variância ANOVA e teste de Tukey, ao nível de significância de 5%. Os resultados mostraram os seguintes valores médios para as fendas de contração dos compósitos: Consept (35,77 μm); Esthet-X (22,01μm); Filtek Z350 (17,95μm), o que demonstrou que o grupo Con diferiu estatisticamente dos demais apresentado maior valor médio em relação à fenda de contração. Baseados nos resultados obtidos, foi possível concluir que o compósito Concept apresentou maior contração de polimerização quando comparado às Resinas Compostas Esthet-X e Filtek Z350.


This study evaluated three different brands of composite resins on the slot resulting from the polymerization contraction: Esthet X (Dentsply); Filtek Z350 (3M / ESPE); Concept (Vigodent), all of them in color A3. Composites were placed in a metal matrix with 7mm in internal diameter and 2mm in height, being pressed between 2 glass plaques and photopolymerized for 40 seconds in one of the surfaces with a polymerization system by halogen light XL 3000 (3M/ ESPE) to 500 +/- 10 mW/cm2. After that, it was polished in politriz, metallized in gold and taken for analysis of the slot resultant of the polymerization contraction in a scanning electron microscope (SEM, Philips XL30). Four measurements were made for each body of evidence in areas corresponding to 3, 6, 9 and 12 hours...


Subject(s)
Dental Stress Analysis , Composite Resins/chemistry
12.
J. Health Sci. Inst ; 25(4): 437-441, out.-dez. 2007. tab
Article in Portuguese | LILACS | ID: lil-655194

ABSTRACT

Introdução - Este estudo se propõe a comparar a força de retenção de núcleos diretos de fibra de vidro obtidos a partir das técnicas direta e direta-indireta, cujos preenchimentos radiculares foram realizados com diferentes materiais (cimento resinoso ou resina composta). Material e Métodos - Quarenta raízes de dentes bovinos com comprimento de 12 mm foram tratadas endodonticamente e divididas aleatoriamente em 4 grupos de acordo com a técnica de obtenção dos pinos e material utilizado para preenchimento (n=10): grupo 1 (técnica direta associada ao cimento resinoso); grupo 2 (técnica direta associada à resina composta); grupo 3 (técnica direta-indireta associada ao cimento resinoso); e grupo 4 (técnica direta-indireta associada à resina composta). A força de retenção foi determinada através do teste de tração usando Universal Testing Machine (Instron). Todos os dados foram analisados usando one-way analysis of variance (ANOVA) com a significância de p<0.05. Após o teste, as interfaces adesivas onde ocorreram as falhas foram examinadas e classificadas. Resultados - O grupo 4 (95,18N) apresentou força de retenção estatisticamente maior que os grupos 3 (57,94N), 2 (39,09N) e 1 (30,70N). A maior parte das fraturas ocorreu na interface dentina/resina. Conclusão - Com base nos resultados obtidos, conclui-se que a utilização da resina composta como material de preenchimento, utilizada com método direto-indireto proporcionou a melhor retenção dos pinos de fibra de vidro.


Introduction - The purpose of this study is to compare the retention force of direct-technique and direct-indirect technique using posts fulfilled with resin cement or resin. Material and Methods - Fourty bovine single root teeth with 12mm of length were used in this study. The roots were endodontically treated and randomly divided in four groups according to the fulfill material and technique used: group 1 (direct technique, resin cement), group 2 (direct technique, composite resin), group 3 (direct-indirect technique, resin cement), group 4 (direct-indirect technique, composite resin). The retention force was determined sing a Universal Testing Machine (Instron). All data were analyzed using one-way analysis of variance (ANOVA) and Scheffe's test. After the test, the failure was examined and classified according to the fracture place: post/ resin; resin/dentin; mix. Results - Group 4 (95,18N) showed statistically higher retention force than group 3 (57,94N), 2 (39,09N) and 1 (30,70N). Most of fracture occurred in interface between dentin/resin. Conclusion - Based on the obtained results, it was concluded that adhesive cementation technique influenced in the retention of glass fiber post with better retention force obtained when composite resin was used as a core build up material with direct-indirect technique.


Subject(s)
Animals , Cattle , Tensile Strength , Post and Core Technique , Resin Cements , Dental Pins , Dental Stress Analysis , Root Canal Filling Materials , Polymerization
SELECTION OF CITATIONS
SEARCH DETAIL