Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Type of study
Year range
1.
Braz. j. otorhinolaryngol. (Impr.) ; 88(supl.1): 118-127, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1420797

ABSTRACT

Abstract Introduction Anatomical variations in the sinonasal region are remarkably common and these variations may have an impact on maxillary sinus development due to their close anatomical adjacency. Objective The aim of this study was to investigate the effect of anatomical variations of the sinonasal region on the width, height, length, and volume of the maxillary sinus. Methods Cone beam computed tomography records of 120 patients were evaluated. Nasal septum deviation angle was measured for each patient and patients were divided into three groups as mild, moderate, and severe. Sinonasal variations such as nasal septum deviation direction, septal spur, concha bullosa, uncinate process pneumatization, middle concha hypertrophy, inferior concha hypertrophy, paradoxical middle concha and presence of septa in the maxillary sinus were registered. Cone beam computed tomography images were transferred to the SimPlant software thus right and left maxillary sinus volumes and dimensions were measured separately. Results There was a negative and statistically significant relationship between age and left maxillary sinus width (p= 0.015). The relationships between gender and maxillary sinus volumes and dimensions were statistically significant (p< 0.05). Although there were significant relationships between the nasal septum deviation severity, middle concha hypertrophy, inferior concha hypertrophy, paradoxical middle concha, and presence of septa and maxillary sinus dimensions; there was no significant relationship between septal spur, nasal septum deviation direction, concha bullosa, uncinate process pneumatization, and maxillary sinus dimensions. No statistically significant relationship could be determined between maxillary sinus volume and anatomical variations of the sinonasal region. Conclusion According to our findings, while certain the variations were found to affect the sinus dimensions; none of the variations was found to be related to the maxillary sinus volume.


Resumo Introdução As variações anatômicas na região nasossinusal são extremamente comuns e essas variações podem ter um impacto no desenvolvimento do seio maxilar, devido à proximidade anatômica. Objetivo Investigar o efeito das variações anatômicas da região nasossinusal na largura, altura, comprimento e volume do seio maxilar. Método Foram avaliados registros de tomografia computadorizada de feixe cônico de 120 pacientes. O ângulo de desvio do septo nasal foi medido para cada paciente e os pacientes foram divididos em três grupos: leve, moderado e grave. Foram observadas variações nasossinusais, como direção do desvio do septo nasal, esporão septal, concha bolhosa, pneumatização do processo uncinado, hipertrofia da concha média, hipertrofia da concha inferior, concha média paradoxal e presença de septos no seio maxilar. Imagens de tomografia computadorizada de feixe cônico foram transferidas para o software SimPlant e, portanto, os volumes e dimensões dos seios maxilares direito e esquerdo foram medidos separadamente. Resultados Houve uma relação negativa e estatisticamente significante entre a idade e a largura do seio maxilar esquerdo (p = 0,015). As relações entre gênero e volumes e dimensões do seio maxilar foram estatisticamente significantes (p < 0,05). Embora houvesse relações significativas entre a gravidade do desvio do septo nasal, hipertrofia da concha média, hipertrofia da concha inferior, concha média paradoxal e presença de septos e dimensões do seio maxilar, não houve relação significativa entre esporão septal, direção do desvio do septo nasal, concha bolhosa, pneumatização do processo uncinado e dimensões do seio maxilar. Nenhuma relação estatisticamente significante pôde ser determinada entre o volume do seio maxilar e as variações anatômicas da região nasossinusal. Conclusão De acordo com nossos achados, embora certas variações tenham afetado as dimensões sinusais, nenhuma das variações foi efetivamente relacionada ao volume do seio maxilar.

2.
Arq. bras. med. vet. zootec. (Online) ; 73(3): 571-582, May-June 2021. tab, graf, ilus
Article in English | LILACS, VETINDEX | ID: biblio-1278365

ABSTRACT

The outcome of total hip arthroplasty (THA) in dogs is directly related to surgical planning. Templating of radiographs prior to THA should help the surgeon anticipate prosthesis size and femoral shape allowing canal fill of the proximal metaphysis by the implant ensuring primary stable fixation. The canal flare index (CFI) obtained from radiograph has been used as a measure of risk of complications for the technique in human beings and dogs. However, standard radiographs only provide limited data for the selection of cementless prostheses and the assessment of their fit within the femoral canal, due to factors like radiographic magnification and femoral rotation. Therefore, three-dimensional evaluation based on computed tomography (CT) may be a better tool for CFI measurement. The aim of this study was to compare anatomical measurement with CFI values obtained from craniocaudal radiography and CT. Craniocaudal radiographs using a horizontal radiographic beam (CR), CT, and anatomical macroscopic measurements (A) were obtained from 45 femurs from 23 canine cadavers. The differences between the values of CFI obtained from radiograph (CFI-R), computed tomography on transverse (CFI- TT) and longitudinal axis (CFI-TL) compared to the CFI obtained from macroscopic measurements - gold standard - (CFI-A), and 95% limits of agreement (LOA) between the values, were evaluated by the Bland-Altman method. Dimensions obtained from CT techniques had a greatest mean difference from anatomical and CFI values were also different (P=0.032). Under the experimental conditions, the craniocaudal radiograph, provided the most accurate measurement of the CFI (mean difference: 0.087 ± 0.42).(AU)


O resultado da artroplastia total do quadril (ATQ) em cães está diretamente relacionado ao planejamento cirúrgico. O templating radiográfico pré-operatório da ATQ deve ajudar o cirurgião a prever o tamanho da prótese e o formato do fêmur, o que permitirá um preenchimento ideal da metáfise proximal pelo implante, garantindo, assim, fixação primária estável. O índice de alargamento do canal (Canal Flare Index - CFI) obtido em radiografias tem sido utilizado como fator de risco de complicações para a técnica em humanos e cães. No entanto, as radiografias podem fornecer apenas dados limitados para a seleção de próteses não cimentadas e a avaliação do seu encaixe no canal femoral, devido a fatores como ampliação radiográfica e rotação femoral. Portanto, a avaliação tridimensional baseada na tomografia computadorizada (TC) pode ser uma ferramenta vantajosa para a mensuração do CFI. O objetivo deste estudo foi comparar a medida anatômica com os valores de CFI obtidos na radiografia craniocaudal e na TC. Radiografias craniocaudais utilizando feixe radiográfico horizontal (CR), tomografia computadorizada e medidas macroscópicas anatômicas (A) foram obtidas de 45 fêmures de 23 cadáveres caninos. As diferenças entre os valores de CFI obtidos na radiografia (CFI-R), na tomografia computadorizada no eixo transversal (CFI-TT) e no eixo longitudinal (CFI-TL), em comparação com os valores de CFI obtidos nas medições macroscópicas - padrão-ouro - (CFI-A) e os limites de concordância de 95% (LOA) entre os valores, foram avaliadas pelo método de Bland-Altman. As dimensões obtidas pelas técnicas de TC apresentaram maior diferença média dos valores anatômicos, e as do CFI também foram diferentes (P=0,032). Nas condições experimentais, a radiografia craniocaudal forneceu a medida mais precisa do CFI (diferença média: 0,087 ± 0,42) para representar o padrão-ouro deste estudo.(AU)


Subject(s)
Animals , Dogs , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/veterinary , Femur/surgery , Femur/diagnostic imaging , Tomography, X-Ray Computed/veterinary , Imaging, Three-Dimensional/veterinary
3.
Arq. bras. med. vet. zootec ; 59(4): 862-868, ago. 2007. ilus
Article in Portuguese | LILACS | ID: lil-462178

ABSTRACT

Adaptou-se uma metodologia utilizada no estudo do movimento humano para analisar o movimento de eqüinos em esteira rolante de alto desempenho, construindo-se um sistema de calibração utilizando-se um teodolito eletrônico de alta precisão e calibradores que demarcavam o espaço ocupado pelo animal. Dessa forma, foram obtidas as coordenadas espaciais dos marcadores presentes nos calibradores, compondo o arquivo de calibração. Duas câmeras de vídeo (60Hz) foram posicionadas em vista lateral esquerda, distantes 5m da manta de rolagem da esteira a 1,8m de altura. As imagens foram enquadradas utilizando-se um monitor de vídeo. Para a validação do método, um membro da equipe movimentou, no espaço calibrado, uma haste rígida com marcadores fixados nas suas extremidades, distantes um do outro 43,8cm. Para a análise das imagens, utilizou-se o programa Dvideow, desenvolvido pelo Laboratório de Instrumentação para Biomecânica - UNICAMP. Após a reconstrução tridimensional das imagens utilizou-se um programa matemático para o cálculo do valor médio da distância entre os marcadores. Obteve-se, após a mensuração em 100 quadros, o valor médio de 43,7cm com coeficiente de variação de 0,8 por cento. Estes resultados mostram que a metodologia desenvolvida é precisa e adequada para o estudo da locomoção de eqüinos


A methodology used for the study of human movement was adapted to analyze the movement of equines in a high performance treadmill. An electronic high precision theodolite was used to construct a calibration system to demarcate the volume occupied by the animal. It was taken the three dimensions coordinates of each marker present in the calibrator, composing the calibration archive. Two video cameras (60 Hz) were located approximately 5m from the left lateral side of the treadmill at 1.8m height. The images had been fit using a video monitor. For the validation of the method, a member of the team moved into the calibrated space, a 43.8cm long rigid stick with markers settled in its extremities. For the analysis of the images, the Dvideow program developed by the Laboratório de Instrumentação para Biomecânica - UNICAMP was used. After the three-dimensional reconstruction of the images, the calculation of the distance between the markers of the stick was done in 100 frames. The mean was 43.7 cm with a variation coefficient of 0.8 percent. These results confirm that this methodology is precise and adequate for the study of the locomotion in horses


Subject(s)
Animals , Horses/physiology , Kinesiology, Applied/methods , Image Interpretation, Computer-Assisted/methods , Movement , Exercise Test/methods , Exercise Test
SELECTION OF CITATIONS
SEARCH DETAIL