Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Journal of the Korean Radiological Society ; : 335-338, 2007.
Article in Korean | WPRIM | ID: wpr-42911

ABSTRACT

Endovascular repair of abdominal aortic aneurysm is associated with low morbidity and mortality rates when compared to open surgery, and this can be used in patients who are at a high risk for open surgical repair. Also, secondary intervention is an important for achieving intermediate and long term success of endovascular repair of abdominal aortic aneurysm as this can resolve complications. We report here on endovascular stent-graft placement and a secondary interventional procedure in the abdominal aortic aneurysm of a patient who had a previously inserted iliac stent.


Subject(s)
Humans , Aortic Aneurysm , Aortic Aneurysm, Abdominal , Iliac Artery , Mortality , Stents
2.
Korean Journal of Radiology ; : 256-266, 2005.
Article in English | WPRIM | ID: wpr-210572

ABSTRACT

OBJECTIVE: We wanted to retrospectively evaluate the long-term therapeutic results of iliac arterial stent placement that was done in a single institution for 10 years. MATERIALS AND METHODS: From May 1994 to April 2004, 206 patients who underwent iliac arterial stent placement (mean age; 64+/-8.8) were followed up for evaluating the long term stent patency. Combined or subsequent bypass surgery was performed in 72 patients. The follow up period ranged from one month to 120 months (mean; 31+/-25.2 months). The factors that were analyzed for their effect on the patency of stents were age, the stent type and diameter, the lesion site, lesion shape, lesion length, the Society of Cardiovascular and Interventinal Radiology criteria, the total run off scores, the Fontaine stage and the cardiovascular risk factors (diabetes mellitus, hypertension and smoking). Follow-up included angiography and/or CT angiography, color Doppler sonography and clinical evaluation with the ankle-brachial index. RESULTS: Two hundred and eighty-four stents were placed in 249 limbs of 203 patients. The technical success rate was 98% (203/206). The primary patency rates of the stents at 3, 5, 7 and 10 year were 87%, 83%, 61% and 49%, respectively. One hundred seventy-seven patients maintained the primary stent patency until the final follow up and 26 patients showed stenosis or obstruction during the follow up. Secondary intervention was performed in thirteen patients. Lesions in the external iliac artery (EIA) or lesions in both the common iliac artery (CIA) and EIA were a poor prognostic factor for stent patency. The run off score and stent diameter also showed statistically significant influence on stent patency. The overall complication rate was 6%. CONCLUSION: Iliac arterial stent placement is a safe treatment with favorable long term patency. Lesions in the EIA or lesions in both the EIA and CIA, poor run off vessels and a stent having the same or a larger diameter than 10 mm were the poor prognostic factors for long term stent patency.


Subject(s)
Middle Aged , Male , Humans , Female , Aged, 80 and over , Aged , Vascular Patency , Treatment Outcome , Stents , Risk Factors , Retrospective Studies , Iliac Artery , Arterial Occlusive Diseases/therapy
3.
Journal of the Korean Radiological Society ; : 173-179, 2003.
Article in Korean | WPRIM | ID: wpr-198203

ABSTRACT

PURPOSE: To determine the long-term patency rate in 68 patients with iliac artery occlusion who underwent metallic stent implantation, and to analyze the factors related to recurrence. MATERIALS AND METHODS: Sixty-eight patients with occlusive disease of the iliac artery underwent implantation of a self-expandable metallic stent. The clinical symptoms were intermittent claudication (n=48), resting pain (n=11), and gangrene (n=9). Stent patency was determined by follow-up angiography and color Doppler imaging, and the cumulative patency rate using the Kaplan-Meier method. Cox's proportional hazard model was used to analyse recurrence-related factors involving clinical symptoms (Fontaine stage), risk factors, and anatomical factors such as lesion location, length, and the development of collaterals. The duration of followup varied from 1 day to 73 months (mean, 23.8 months). RESULTS: Arterial occlusion recurred in 16 of 68 patients (23.5%), and the cumulative patency rate was as follows: 95.4% at one month, 93.2% at six months, 80.1% at one year, 73.2% at two years, 68.9% at three years, and 62% at five years. According to a statistical analysis of risk factors, the recurrence p=0.04) than in those without it, but in patients who smoked, hypertension, DM, and previous cerebrovascular disease were not statistically significant. With regard to anatomical factors, the recurrent rate for lesions involving the external iliac artery was 6.5 times higher (p=0.02) than for those involving the common iliac artery. Variations in the Fontaine stage were not statistically significant indicators of recurrence. CONCLUSION: The recurrence rate after implantation of an iliac artery stent is higher in patients with heart disease than in those without it, and higher for occlusive lesions involving the external iliac artery than for those of the common iliac artery.


Subject(s)
Humans , Angiography , Follow-Up Studies , Gangrene , Heart Diseases , Hypertension , Iliac Artery , Intermittent Claudication , Proportional Hazards Models , Recurrence , Risk Factors , Smoke , Stents
4.
Journal of the Korean Radiological Society ; : 255-261, 2001.
Article in Korean | WPRIM | ID: wpr-94587

ABSTRACT

PURPOSE: To determine the long-term patency of percutaneous intravascular metallic stent placement in patients with chronic iliac artery stenosis. MATERIALS AND METHODS: Intravascular metallic stents were placed percutaneously in 41 limbs of 38 patients with chronic iliac artery stenosis who presented with intermittent claudication in 40 limbs and gangrene in the other. Preoperative angiography showed that complete occlusion occurred in one limb, and luminal stenosis of over 50% in 34 and of less than 50% in six. The mean length of stenoses was 3.1 (range, 1 -8) cm, and in all cases the systolic pressure gradient was over 10 (range, 12 -100, mean, 43) mmHg. Stent placement was indicated by failed balloon angioplasty in 35 limbs, primary stenting in five, and restenosis after balloon angioplasty in one. Technical and clinical success were evaluated in terms of immediate results and stent patency over a period of 1 -49 (mean, 19) months (Kaplan-Meier method). RESULTS: Stent placement was successful in all cases in which residual stenosis was less than 10% and systolic pressure gradient less than 2 mmHg. One to three days after the procedure, clinical symptoms had improved in 40 limbs and ABI (n=23) had increased from 0.64 +/-0.20 to 0.92 +/-0.17. Follow-up studies demonstrated patency rates of 94.1% at 6 months, 90.7% at 1 year, 86.6% at 2 years, and 86.6% at 4 years. CONCLUSION: Our results showed that in patients with chronic iliac artery stenosis, percutaneous intravascular metallic stent placement led to patency rates which were similar over a period of between six months and four years.


Subject(s)
Humans , Angiography , Angioplasty, Balloon , Blood Pressure , Constriction, Pathologic , Extremities , Follow-Up Studies , Gangrene , Iliac Artery , Intermittent Claudication , Phenobarbital , Stents
5.
Korean Journal of Radiology ; : 145-150, 2001.
Article in English | WPRIM | ID: wpr-100804

ABSTRACT

OBJECTIVE: To investigate the effectiveness of the newly designed Niti-S stent in the management of iliac arterial stenoses and occlusions. MATERIALS AND METHODS: Stenoses (n=25) or occlusions (n=5) in the iliac arteries of 25 patients (30 limbs) were treated. The site of the lesions was the common (n=15) or external (n=11) iliac artery, or both (n=4). Eight limbs were treated for diffuse disease, six for highly eccentric lesion, five for occlusive lesion, and 11 for failed angioplasty. RESULTS: In all patients, technical success was achieved without major complications. One death, not procedure-related, occurred within 30 days. Ankle-brachial indexes improved from 0.63 +/- 0.30 to 0.99 +/- 0.21, and ischemic symptoms showed improvement in 22 patients (88%). Fontaine classifications before stenting, namely IIa(n=3), IIb(n=16), III(n=2), and IV(n=4) improved to I(n=17), IIa(n=5), and IV(n=3). Follow-up over a 27 (mean, 19.8 +/- 8)-month period showed that cumulative patency rates were 95.8% at 1 year and 86.2% at 2 and 3 years. No significant decrease in the mean ankle-brachial index was observed. CONCLUSION: The Niti-S stent appears to be a safe and effective device for the treatment of iliac stenoses and occlusions. These preliminary results require confirmation with a larger series.


Subject(s)
Aged , Female , Humans , Male , Alloys , Arterial Occlusive Diseases/therapy , Equipment Design , Iliac Artery , Stents
SELECTION OF CITATIONS
SEARCH DETAIL