Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Rev. bras. ortop ; 58(6): 847-853, 2023. graf
Article in English | LILACS | ID: biblio-1535615

ABSTRACT

Abstract Objective This study proposes the Niza box, a device created to reduce interpretive errors among professionals and facilitate the correct positioning of structures by standardizing orthopedic radiography of the foot in anteroposterior, loaded, and Saltzman views. Methods Descriptive study based on material collected at an Orthopedics Ambulatory from a tertiary service in a large Brazilian city. The X-ray device was a Lotus X, model HF 500 M, 500 milliamperes and 125 kilovolts capacity, 100 cm focus-film distance, and 24 × 30 cm radiographic chassis. Device controls were set at 100 mA, 5 mA/sec, and 60 kilovolts, depending on the variable size of the foot. The same team of previously trained radiography technicians performed the tests under the authors' supervision. The chassis were positioned in three specific Niza box spaces per the proposed incidence. Data from 50 images from people between 18 and 70 years old were analyzed. Results Radiographs taken using the proposed device usually had a satisfactory quality, allowing correct identification of the anatomical elements of the foot and ankle and angular reconstruction. Small image variations due to foot size were acceptable and expected, allowing radiograph standardization. Conclusion The Niza box is a good method for minimizing interference and avoiding radiographic interpretation errors, providing quality and agility to the examination, and reducing cost and unnecessary repetitions. It is an innovative, low-cost device made of recyclable and biodegradable material.


Resumo Objetivo Este estudo propõe a utilização da Caixa Niza, dispositivo criado com a finalidade de diminuir os erros interpretativos entre profissionais e facilitar o correto posicionamento das estruturas radiografadas ao padronizar as incidências radiográficas ortopédicas do pé anteroposterior, perfil com carga e Saltzman. Métodos Pesquisa descritiva, material coletado em Ambulatório de Ortopedia em serviço terciário de cidade brasileira de grande porte. Utilizado aparelho de radiografia marca Lotus X, modelo HF 500M, capacidade de 500 miliamperes e 125 quilovolts, distância foco-filme de 100cm, chassi radiográfico 24×30 cm e os comandos do aparelho ajustados para 100 mA, 5mA/seg e 60 quilovolts dependendo do tamanho variável dos pés. Exames realizados pela mesma equipe de técnicos em radiografia previamente treinados com supervisão dos autores. O chassi é posicionado em três espaços específicos da Caixa conforme a incidência proposta. Foram analisados dados de 50 imagens de pessoas entre 18 e 70 anos. Resultados A avaliação das radiografias após utilização do dispositivo proposto ocorreu de modo geral com qualidade satisfatória, permitindo correta identificação dos elementos anatômicos do pé e tornozelo e reconstrução angular. Pequenas variações nas imagens devido ao tamanho dos pés são aceitáveis e esperadas, sendo possível perceber padronização das radiografias. Conclusão A Caixa proposta se mostra um bom método de minimizar as interferências e evitar erros de interpretação radiográfica, proporcionando qualidade e agilidade ao exame, diminuindo custo e repetições desnecessárias. É inovador, um dispositivo de baixo custo, de material reciclável e biodegradável.


Subject(s)
Humans , Adult , Middle Aged , Aged , Foot Joints/diagnostic imaging , Foot/diagnostic imaging
2.
Acta ortop. bras ; 16(1): 45-48, 2008. ilus, graf, tab
Article in English, Portuguese | LILACS | ID: lil-482453

ABSTRACT

INTRODUÇAO: As artrodeses tarsometatársicas sao opçao terapeutica efetiva no tratamento das osteoartroses sintomaticas da articulacao de Lisfranc. Os métodos de estabilizaçao disponíveis sao: Fios de Kirschner, Parafusos Corticais, Placas e parafusos e Agrafe. A estabilidade oferecida e a técnica cirúrgica utilizada para cada material é discutida na literatura. OBJETIVO: Comparar a força de compressão e a estabilidade biomecânica da fixação da articulação tarsometatársica com Parafusos Corticais e com Agrafe. CASUISTICA E MÉTODO: Selecionados 10 cadáveres frescos, do genero masculino, idade variando de 35 a 49 anos, foram submetidas a dissecçao do cúboide e do 4º metatarso bilateralmente, decorticadas as superfícies articulares e realizada fixação com parafuso cortical - Cortical Screw 3.5mm Impol, e Agrafe - Uni-clip® Staple 2.0 NewDeal. RESULTADOS: Os 20 ensaios biomecânicos foram completados. A analise estatística dos métodos agrafe vs parafuso cortical, em relação a energia acumulada até atingir o pico de força do ensaio p= 0.047, e a energia acumulada até o final do ensaio p= 0.047 apresentaram diferença significativa. CONCLUSÃO: Os picos de carga suportados pelas estabilizaçoes com agrafe e com parafuso cortical decrescem, significativamente, com a idade. Observa-se valores de força superiores para o agrafe em ossos osteoporóticos. A energia acumulada na area de trabalho dos graficos nos ensaios com o agrafe, mostram-se estatisticamente superiores aos valores para os Parafusos Corticais.


INTRODUCTION: Tarsometatarsal arthrodeses are an effective therapeutic alternative for treating symptomatic osteoarthroses of the Lisfranc joint. Stabilization methods available include: Kirschner's wires, cortical screws, plates and screws and staples. The stability provided and the surgical technique employed with each material is discussed in literature. PURPOSE: To compare compression forces and biomechanical stability of tarsometatarsal joint fixation with cortical screws and staples. CASE SERIES AND METHOD: Ten fresh male cadavers with ages ranging from 35 to 49 years were selected and submitted to bilateral dissection of the cuboidal and 4th metatarsal bones, with joint surfaces decortification and fixation with cortical screw - Cortical Screw 3.5mm Impol, and Uni-clip® Staple 2.0 NewDeal. RESULTS: All the 20 biomechanical assays were completed. The statistical analysis of the methods using staples vs. cortical screw concerning accrued energy until reaching the assay's peak force p= 0.047, and the accrued energy until the completion of the assay p= 0.047 showed a significant difference. CONCLUSION: Load peaks supported by staples and cortical screws are significantly reduced with age. Superior force values are found for staples in osteoporotic bones. The accrued energy on graphs' work areas in assays with staples is shown to be statistically superior to cortical screws' values.


Subject(s)
Humans , Male , Adult , Arthrodesis/methods , Foot Joints , Internal Fixators , Tarsal Joints , Biomechanical Phenomena/methods , Bone Screws , Osteoporosis
3.
Acta ortop. bras ; 15(5): 242-245, 2007. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-473501

ABSTRACT

OBJETIVO: Este trabalho teve como objetivo estimar as forças plantares nos dedos dos pés de mulheres com hálux valgo e/ou pés planos. MÉTODOS: Trata-se de um estudo transversal envolvendo mulheres com hálux valgo e/ou pés planos confirmado através de análise radiográfica. Mediram-se as forças plantares, utilizando plataformas de forças. Coletaram-se estas forças com as mulheres descalças e em posição ereta, por três medidas sendo obtida uma média. Os dados foram adquiridos através da ponte amplificadora Spider 8 da HBM e analisados através do programa Catman®. Obtiveram-se as medidas de forças dos dedos de ambos os pés e as médias foram comparadas pelo teste t de Student segundo a presença de hálux valgo e pés planos; a associação entre essas deformidades foi estimada pelo teste exato de Fischer bicaudal, a significância estatística adotada foi alfa = 5 por cento. RESULTADOS: Foram incluídas no estudo, vinte mulheres com presença ou não de hálux valgo. As forças médias encontradas mostraram-se maiores no 5º dedo em relação ao 1º dedo de ambos os pés (p< 0,05) em ambas as situações. CONCLUSÃO: Neste estudo encontraram-se, ao contrário de outros trabalhos, forças no 5º dedo maiores que no 1º em ambos os pés.


OBJECTIVE: to measure the plantar forces above the toes of women with hallux valgus and/or flat feet. METHODS: This study involved women with hallux valgus and/or flat feet confirmed by X-ray images. The plantar forces were measured utilizing force plates. Force was measured three times, which were taken with the women on barefoot and at upright position, recording the average for the three measurements. Data were acquired from Spider 8 system (HBM) and analyzed by using a Catman® software. The measurements for both feet's toes force were reported and the averages were compared by the Student's t-test according to the presence of hallux valgus and flat feet; the association between these deformities was estimated by using the two-tailed Fischer's exact test, the statistical significance adopted was alpha = 5 percent. RESULTS: For this study, 20 women with or without hallux valgus were included. The mean force values found showed to be higher on the fifth toe compared to first toe of both feet (p < 0.05) in both situations. CONCLUSION: in this study, we found strong forces on the fifth toe than on the first toe, contradicting some studies in literature.


Subject(s)
Humans , Female , Young Adult , Middle Aged , Hallux Valgus/physiopathology , Flatfoot/physiopathology , Flatfoot , Body Mass Index , Brazil , Cross-Sectional Studies
SELECTION OF CITATIONS
SEARCH DETAIL