Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Rev. colomb. anestesiol ; 49(4): e301, Oct.-Dec. 2021. tab, graf
Article in English | LILACS, COLNAL | ID: biblio-1341240

ABSTRACT

Abstract Patients with implantable electric stimulation devices are challenging to the anesthesiologist since these cases demand a comprehensive knowledge about how the device operates, the indications for the implant and the implications that must be addressed during the perioperative period. This article is intended to provide the reader with clear and structured information so that the anesthesiologist will be able to safely deal with the situation of a patient with an implantable cardiac stimulation device, who has been programmed for emergent surgery. A search for the scientific evidence available was conducted in Pubmed / Medline, ScienceDirect, OVID, SciELO), for a non-systematic review. The incidence of the use of cardiac electric stimulation devices has been growing. Their operation is increasingly complex, and demands being constantly updated on the knowledge in the area.


Resumen El paciente portador de un dispositivo de estimulación eléctrica cardiaca implantable se convierte en un reto para el anestesiólogo debido a que implica un conocimiento integral que abarca su funcionamiento, las indicaciones que llevaron a su implante y las implicaciones que se deben abordar en el perioperatorio. Este artículo busca proporcionar al lector información clara y estructurada que le permita al anestesiólogo enfrentarse de forma segura al escenario de un paciente con un dispositivo de estimulación eléctrica cardiaca implantable programado para cirugía emergente. Se realizó una búsqueda de la evidencia científica disponible en bases de datos (Pubmed / Medline, ScienceDirect, OVID, SciELO), para una revisión no sistemática. La incidencia en el uso de dispositivos de estimulación eléctrica cardiaca viene en aumento. Su funcionamiento es cada vez más complejo lo cual implica una actualización permanente del conocimiento en esta área.


Subject(s)
Humans , Cardiac Pacing, Artificial , Perioperative Period , Cardiac Resynchronization Therapy Devices , Radiography , Defibrillators, Implantable , Electric Stimulation/methods , Anesthesiologists
3.
Rev. enferm. UERJ ; 27: e45014, jan.-dez. 2019. tab
Article in Portuguese | LILACS, BDENF | ID: biblio-1097364

ABSTRACT

Objetivo: avaliar a qualidade de vida de indivíduos portadores de dispositivo cardíaco eletrônico implantável. Método: estudo descritivo e transversal realizado com 50 indivíduos em 2018. Utilizou-se o SF-36 e AQUAREL. Resultados: a comorbidade mais frequente foi a hipertensão arterial sistêmica ­ 39 (78%), a cardiopatia de base a bradicardia ­ 18 (36%) e queixas de palpitação e pré-síncope. Predominaram indivíduos com tempo do dispositivo cardíaco eletrônico de até 5 anos ­ 24 (48%), sem troca de gerador ­ 31 (62%). A maioria negou o consumo de bebida alcóolica ­ 47 (94%), de cigarros ­ 44 (88%) e não realiza atividade física regular ­ 34 (68%). No SF-36, o menor escore foi no domínio aspectos físicos (15) e o maior em dor (88,8). No AQUAREL o menor escore foi no domínio dispneia (78,98) e o maior em desconforto (86,54). Conclusão: constatou-se sintomatologia reduzida. Houve associação significativa entre sexo masculino e atividade física. Os indivíduos apresentam melhora da qualidade de vida após a implantação do dispositivo cardíaco.


Objective: to evaluate the quality of life of individuals with implantable electronic cardiac devices. Method: descriptive and cross-sectional study conducted with 50 individuals in 2018. SF-36 and AQUAREL were used. Results: the most frequent comorbidity was systemic arterial hypertension ­ 39 (78%), baseline heart disease bradycardia ­ 18 (36%) and complaints of palpitation and pre-syncope. Individuals with electronic cardiac device time of up to 5 years 24 (48%) predominated, without changing the generator ­ 31 (62%). The majority denied alcohol consumption ­ 47 (94%), cigarettes ­ 44 (88%) and regular physical activity ­ 34 (68%). In the SF-36 the lowest score was in the physical aspects domain (15) and the highest in pain (88.8). In AQUAREL the lowest score was in the domain dyspnea (78.98) and the highest in discomfort (86.54). Conclusion: reduced symptomatology was observed. There was a significant association between males and physical activity. Individuals have improved quality of life after implantation of the cardiac device.


Objetivo: evaluar la calidad de vida de las personas con dispositivos cardíacos electrónicos implantables. Método: estudio descriptivo y transversal realizado con 50 individuos, en 2018. SF-36 y AQUAREL se utilizaron. Resultados: la comorbilidad más frecuente fue la hipertensión arterial sistémica ­ 39 (78%), las cardiopatías subyacentes, bradicardia ­ 18 (36%) y quejas de palpitación y presíncope. Predominan los individuos con tiempo de dispositivo cardíaco electrónico de hasta 5 años ­ 24 (48%) sin cambiar el generador ­ 31 (62%). La mayoría negó el consumo de alcohol ­ 47 (94%), cigarrillos ­ 44 (88%) y actividad física regular 34 (68%). En el SF-36, la puntuación más baja estaba en el dominio de aspectos físicos (15) y la más alta en dolor (88.8). En AQUAREL, la puntuación más baja estaba en el dominio disnea (78,98) y la más alta en malestar (86,54). Conclusión: se observó una sintomatología reducida. Hubo una asociación significativa entre los varones y la actividad física. Los individuos han mejorado la calidad de vida después de la implantación del dispositivo cardíaco.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Pacemaker, Artificial , Quality of Life , Electric Countershock , Cardiac Pacing, Artificial , Cardiovascular Diseases/therapy , Cardiac Resynchronization Therapy Devices , Cardiovascular Diseases/complications
4.
Salud UNINORTE ; 34(2): 383-392, mayo-ago. 2018. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1004591

ABSTRACT

Abstract Objective: To cross-culturally adapt into the Colombian context the "Florida Patient Acceptance Survey" instrument which measures the acceptance of people implanted with cardiac stimulation devices. Materials and methods: The methodology of translation and back translation has been followed, with the equivalence in cultural semantics to carry out the cross-cultural adaptation of the original version of the instrument Florida Patient Acceptance Survey (FPAS). In the process, experts participated in the areas of: cardiac rhythm disorders, mental health and the validation of health measurement instruments, as well as a professional in linguistics and a professional in statistics. Results: It has been achieved to obtain a Spanish version of the FPAS instrument culturally adapted to the Colombian context, with the necessary adjustments for the understanding of the target population, in order to preserve the semantic and conceptual equivalence of the original version. Conclusions: The Spanish version of the FPAS is semantically and culturally equivalent to its original English version. From the contributions of the experts, adjustments were made, that did not modify the essence of the instrument, after which all the psychometric tests will be performed to carry out the process of validation of the instrument.


Resumen Objective: Adaptar transculturalmente al contexto colombiano el instrumento "Florida Patient Acceptance Survey" que mide la aceptación de las personas implantadas con dispositivos de estimulación cardiaca. Materiales y métodos: Se ha seguido la metodología de traducción y retrotraducción, con equivalencia en semánticas culturales para llevar acabo la adaptación transcultural de la versión original del instrumento Florida Patient Acceptance Survey (FPAS). En el proceso participaron expertos en el área de: alteraciones del ritmo cardiaco, salud mental y validación de instrumentos de salud, así como, un profesional en lingüística y un profesional en estadística. Resultados: Se logra obtener una versión en español del instrumento FPAS adaptada culturalmente al contexto colombiano, con la realización de ajustes necesarios para la comprensión de la población objeto, a fin de conservar la equivalencia semántica y conceptual de la versión original. Conclusiones: La versión en español del FPAS es semántica y culturalmente equivalente a su versión original en inglés. A partir de los aportes de los expertos se realizaron ajustes que no modificaron la esencia del instrumento, posteriormente se realizarán las pruebas psicométricas para llevar a cabo el proceso de validez y fiabilidad.

5.
Rev. argent. cardiol ; 78(2): 143-146, mar.-abr. 2010. ilus
Article in Spanish | LILACS | ID: lil-634159

ABSTRACT

Las dificultades inherentes a la técnica de implante de resincronizadores han generado la necesidad de buscar nuevas opciones, como el implante endocavitario en el ventrículo izquierdo por vía transeptal auricular desde la aurícula derecha. En tal sentido, en los últimos años ya se realizaron varias publicaciones. Si bien los resultados son satisfactorios, en todos los casos se utilizan técnicas "especiales", que tienen sus dificultades propias y requieren gran experiencia y una curva de aprendizaje por parte del operador. Es probable que ésta sea la razón por la cual estas técnicas no se "popularizaron", pese a sus buenos resultados. El procedimiento que se describe en esta presentación pretende establecer un método basado en técnicas de rutina en los laboratorios de electrofisiología de todo el mundo que permita un implante sencillo, efectivo, rápido y pasible de ser utilizado en forma segura con una curva de aprendizaje mínima. Básicamente, el procedimiento consiste en la introducción de un catéter endocavitario en el ventrículo izquierdo a través de una punción transeptal convencional por la vena femoral y su exteriorización por la vena subclavia (derecha o izquierda) para completar el implante en forma convencional.


The difficulties regarding the implantation of devices for cardiac resynchronization therapy have generated the necessity to look for alternative pacing techniques, such as endocardial left ventricular lead placement via the transseptal approach from the right atrium. In this sense, several studies have been published in the last years. Al-though all these studies have reported satisfactory outcomes, they all use "special" techniques with their own limitations, as the procedures should be performed by experienced op-erators who have overcome the learning curve. This might be the reason why these techniques have not become "popular" yet despite the favorable outcomes reported. The procedure here described intends to establish a methodology based on routine techniques used worldwide in the electrophysiology labs to allow a simple, effective, fast and safe lead placement with a minimum learning curve. The procedure consists in introducing an endocardial lead in the left ventricle through a conventional transfemorally performed transseptal puncture; the lead is then tunneled to the right or left subclavian vein and the implant is com-pleted in the conventional fashion.

SELECTION OF CITATIONS
SEARCH DETAIL