Article | IMSEAR | ID: sea-211328

ABSTRACT

Background: Thrombocyte is important and very essential component of blood and have significant role in maintenance of hemostasis. Thrombocyte count is an important investigation done in various acquired and congenital coagulable states which include conditions like pregnancy. Thrombocyte count is routinely done by automated hematology analyzer method. The automated hematology analyzer counters are not usually available at all centres especially in peripheral and rural side though thrombocytes can also be assessed from the peripheral blood smears, which can be easily and precisely done at any set up. Aim and objective of this study was to compare the thrombocyte estimation by peripheral blood smear method and automated hematology analyzer in pregnant women.Methods: Thrombocyte estimation was done from samples taken from 120 normal pregnant women between December 2018 to March 2019, where samples were Ethylene Diamine Tetra Acetic acid (EDTA) anticoagulated. Thrombocyte was counted manually using PBS (Leishman stain) and hematology analyzer (Sysmex XN1000 series). Thrombocyte counts were expressed in Mean and standard Deviation. Statistical analysis was done by student’s t test using MS excel and SPSS version 17.Results: Thrombocyte count by PBS have mean value of 2.04 lacs/mm3 with standard deviation of 0.56 lacs/mm3 and by automated method have mean value of 1.89 lacs/mm3 and standard deviation of 0.71 lacs/mm3 with p value 0.010. Thus, there was no statistically significant difference found between two methods.Conclusions: Estimation of thrombocyte count on the basis of manual thrombocyte count is a reliable technique and can be used to validate automated thrombocyte counts. It can also be used in under resourced laboratories, where there are no automated counters of good precision available. In fact, all the tests showing abnormal thrombocyte counts must be reported only after cross examining on PBS.

2.
Chinese Medical Equipment Journal ; (6): 97-100, 2017.
Article in Chinese | WPRIM | ID: wpr-511344

ABSTRACT

Objective To compare the clinical values of impedance method,optical method and microscopy when used to detect platelet abnormal results.Methods Platelet re-examinations by optical method and microscopy were carried out in case of low confidence degree in platelet test with impedance method by XE-2100 automatic hematology analyzer,and then the results by the three methods were compared.Results Most of the low-confidence-degree results by impedance method could be corrected by re-examination by optical method,and the remained had to turn to microscopy due to unsatisfied requirements of the instrument.Conclusion Optical method has to be involved to correct the platelet abnormal results by XE2100 automatic hematology analyzer,and microscopy should be applied in case optical method doesn't work.The three methods gains advantages and disadvantages of themselves,and can be supplementaries for one another.

3.
Journal of Laboratory Medicine and Quality Assurance ; : 171-176, 2004.
Article in Korean | WPRIM | ID: wpr-60351

ABSTRACT

BACKGROUND: For the diagnosis of malaria, examination of blood smear slides by light microscopy is used as standard, and commercial kits detecting malarial antibodies and antigens are available, and molecular methods such as polymerase chain reaction (PCR) are used additionally. But, these diagnostic methods can be performed when clinicians request them, so problems of misdiagnosing the patients who are not suspected malaria may be occurred. METHODS: In 42 Korean patients with malaria, the author analyzed the characteristic signals of malaria using granularity (90 degrees depolarized) versus lobularity (90 degrees polarized) graph of Cell-Dyn 4000 (CD4000) automatic hematologic analyzer. And, the author examined the presence of malaria in 421 random samples by CD4000 and Giemsa stain. RESULTS: The usefulness of CD4000 in diagnosing malaria are as follows, 93.0% sensitivity, 99.3% specificity, 93.0% positive-predictive value, and 99.3% negative-predictive value. CONCLUSION: CD4000 automatic hematology analyzer has high diagnostic sensitivity and specificity in diagnosing malaria. Because complete blood count (CBC) is the routine test for most patients, this method has advantage of time and cost effectiveness and can even detect malaria in unsuspected cases.


Subject(s)
Humans , Antibodies , Azure Stains , Blood Cell Count , Cost-Benefit Analysis , Diagnosis , Hematology , Malaria , Microscopy , Polymerase Chain Reaction , Sensitivity and Specificity
4.
Chinese Journal of Laboratory Medicine ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-685370

ABSTRACT

Objective To find a proper way for accurate results on completing blood counts.Methods Based on the results from automatic hematology analyzer XE-2100,set up the criteria for blood cell microscopic examination.1368 blood specimen were detected and the results were analyzed according to the criteria.Statistics on the data were made to evaluate the accordance between warnings of analyzer and manual examination,likewise the reliability of the criteria.Results Comparing with microscopic examination,analyzer warning on low PLT has good accordance,Kappa value was 0.95,U value was 35.19,P