Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Postgraduates of Medicine ; (36): 33-35, 2014.
Article in Chinese | WPRIM | ID: wpr-447769

ABSTRACT

Objective To investigate the feasibility of bedside temporary transvenous cardiac pacing with balloon tipped floating catheter under non X-ray fluoroscopy.Methods Twenty-four patients of bedside temporary transvenous cardiac pacing,11 cases underwent common electrode (common group),13cases underwent balloon tipped floating electrode (balloon tipped group).The operating time,pacing thresholds,pacing perception and complications were observed between two groups.Results All balloon tipped group placement success,8 cases in common group successfully.The operating time in balloon tipped group was significantly less than that in common group [(2.5 ± 1.5) min vs.(9.3 ±5.3) min],there was significant difference (P < 0.05),but pacing thresholds and pacing perception between two groups had no significant difference (P > 0.05).Common group occurred complications in 2 cases,respectively cardiac perforation and induced paroxysmal ventricular tachycardia,balloon tipped group occurred concurrent electrode wire dislocation in 2 cases.Conclusion Compared with the common electrode,balloon tipped floating electrode is simple,fast,high success rate and low risk of complications,suitable emergency physician bedside operating emergency temporary pacing.

2.
Chinese Journal of Primary Medicine and Pharmacy ; (12)2006.
Article in Chinese | WPRIM | ID: wpr-559256

ABSTRACT

Objective To investigate the methodology and feasibility of bedside temporary cardiac pacing with balloon-tipped floating catheter by femoral vein approach.Methods 86 patients in this study were treated with bedside temporary cardiac pacing by femoral vein for arrhythmias.A balloon-tipped floating catheter was inserted through the femoral vein in right ventricle,guided by the length of catheter in body and the QRS morphology of pacing electrocardiogram(ECG).After that,the pacing site was identified by X-ray fluoroscopy.Then,the feasibility and successful rate of this bedside temporary cardiac pacing,and the causes for failure were analyzed.Results Guided by the length of catheter and the QRS morphology of pacing ECG,the succesful rate of balloon-tipped floating catheter putted into right ventricle was 98.8%.The most successful pacing sites were located at the right ventricular apex(RVA) and right ventricular out-flow tract(RVOT).The lengths of catheter from the puncture sites to RVA and RVOT were (57.2?3.2)cm and (54.3?3.1)cm,respectively.Incidence of undersensing in RVOT pacing group was significantly higher than that in RVA pacing group(P

SELECTION OF CITATIONS
SEARCH DETAIL