1.
Journal of Periodontal & Implant Science ; : 366-381, 2019.
Article in English | WPRIM | ID: wpr-786135

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the effectiveness of conventional sandblasted, large-grit, acid-etched (SLA) surface coated with a pH buffering solution based on surface wettability, blood protein adhesion, osteoblast affinity, and platelet adhesion and activation.METHODS: Titanium discs and implants with conventional SLA surface (SA), SLA surface in an aqueous calcium chloride solution (CA), and SLA surface with a pH buffering agent (SOI) were prepared. The wetting velocity was measured by the number of threads wetted by blood over an interval of time. Serum albumin adsorption was tested using the bicinchoninic acid assay and by measuring fluorescence intensity. Osteoblast activity assays (osteoblast adhesion, proliferation, differentiation, mineralization, and migration) were also performed, and platelet adhesion and activation assays were conducted.RESULTS: In both the wetting velocity test and the serum albumin adsorption assay, the SOI surface displayed a significantly higher wetting velocity than the SA surface (P=0.000 and P=0.000, respectively). In the osteoblast adhesion, proliferation, differentiation, and mineralization tests, the mean values for SOI were all higher than those for SA and CA. On the osteoblast migration, platelet adhesion, and activation tests, SOI also showed significantly higher values than SA (P=0.040, P=0.000, and P=0.000, respectively).CONCLUSIONS: SOI exhibited higher hydrophilicity and affinity for proteins, cells, and platelets than SA. Within the limits of this study, it may be concluded that coating an implant with a pH buffering agent can induce the attachment of platelets, proteins, and cells to the implant surface. Further studies should be conducted to directly compare SOI with other conventional surfaces with regard to its safety and effectiveness in clinical settings.


Subject(s)
Adsorption , Blood Platelets , Calcium Chloride , Coated Materials, Biocompatible , Dental Implants , Fluorescence , Hydrogen-Ion Concentration , Hydrophobic and Hydrophilic Interactions , Immunoassay , In Vitro Techniques , Miners , Osteoblasts , Serum Albumin , Surface Properties , Titanium , Wettability
2.
Journal of Periodontal & Implant Science ; : 18-23, 2013.
Article in English | WPRIM | ID: wpr-18704

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the osseointegration of calcium phosphate (CaP)-coated implants by ion beam assisted deposition with a lack of primary stability. METHODS: A total of 20 CaP-coated implants were bilaterally placed in the mandible of five dogs. In the rotational implant group, the implants were inserted in oversized drilled sockets without mechanical engagement, while the conventional surgical protocol was followed in the control group. Each group was allowed to heal for 4 and 8 weeks. The bone-to-implant contact (BIC, %) was measured by a histometric analysis. RESULTS: All of the implants were well-maintained and healing was uneventful. In the histologic observation, all of the implants tested were successfully osseointegrated with a high level of BIC at both observation intervals. There was no significant difference in BIC among any of the groups. CONCLUSIONS: Within the limitation of this study, successful osseointegration of CaP-coated implants could be achieved in unfavorable conditions without primary stability.


Subject(s)
Animals , Dogs , Calcium , Calcium Phosphates , Coated Materials, Biocompatible , Dental Implants , Mandible , Mandrillus , Osseointegration
3.
Journal of Periodontal & Implant Science ; : 59-63, 2012.
Article in English | WPRIM | ID: wpr-135237

ABSTRACT

PURPOSE: This study evaluated the surface characteristics and bond strength produced using a novel technique for coating hydroxyapatite (HA) onto titanium implants. METHODS: HA was coated on the titanium implant surface using a super-high-speed (SHS) blasting method with highly purified HA. The coating was performed at a low temperature, unlike conventional HA coating methods. Coating thickness was measured. The novel HA-coated disc was fabricated. X-ray diffraction analysis was performed directly on the disc to evaluate crystallinity. Four novel HA-coated discs and four resorbable blast medium (RBM) discs were prepared. Their surface roughnesses and areas were measured. Five puretitanium, RBM-treated, and novel HA-coated discs were prepared. Contact angle was measured. Two-way analysis of variance and the post-hoc Scheffe's test were used to analyze differences between the groups, with those with a probability of P<0.05 considered to be statistically significant. To evaluate exfoliation of the coating layer, 7 sites on the mandibles from 7 mongrel dogs were used. Other sites were used for another research project. In total, seven novel HA-coated implants were placed 2 months after extraction of premolars according to the manufacturer's instructions. The dogs were sacrificed 8 weeks after implant surgery. Implants were removed using a ratchet driver. The surface of the retrieved implants was evaluated microscopically. RESULTS: A uniform HA coating layer was formed on the titanium implants with no deformation of the RBM titanium surface microtexture when an SHS blasting method was used. CONCLUSIONS: These HA-coated implants exhibited increased roughness, crystallinity, and wettability when compared with RBM implants.


Subject(s)
Animals , Dogs , Bicuspid , Coated Materials, Biocompatible , Crystallins , Dental Implants , Durapatite , Hydroxyapatites , Mandible , Titanium , Wettability , X-Ray Diffraction
4.
Journal of Periodontal & Implant Science ; : 59-63, 2012.
Article in English | WPRIM | ID: wpr-135236

ABSTRACT

PURPOSE: This study evaluated the surface characteristics and bond strength produced using a novel technique for coating hydroxyapatite (HA) onto titanium implants. METHODS: HA was coated on the titanium implant surface using a super-high-speed (SHS) blasting method with highly purified HA. The coating was performed at a low temperature, unlike conventional HA coating methods. Coating thickness was measured. The novel HA-coated disc was fabricated. X-ray diffraction analysis was performed directly on the disc to evaluate crystallinity. Four novel HA-coated discs and four resorbable blast medium (RBM) discs were prepared. Their surface roughnesses and areas were measured. Five puretitanium, RBM-treated, and novel HA-coated discs were prepared. Contact angle was measured. Two-way analysis of variance and the post-hoc Scheffe's test were used to analyze differences between the groups, with those with a probability of P<0.05 considered to be statistically significant. To evaluate exfoliation of the coating layer, 7 sites on the mandibles from 7 mongrel dogs were used. Other sites were used for another research project. In total, seven novel HA-coated implants were placed 2 months after extraction of premolars according to the manufacturer's instructions. The dogs were sacrificed 8 weeks after implant surgery. Implants were removed using a ratchet driver. The surface of the retrieved implants was evaluated microscopically. RESULTS: A uniform HA coating layer was formed on the titanium implants with no deformation of the RBM titanium surface microtexture when an SHS blasting method was used. CONCLUSIONS: These HA-coated implants exhibited increased roughness, crystallinity, and wettability when compared with RBM implants.


Subject(s)
Animals , Dogs , Bicuspid , Coated Materials, Biocompatible , Crystallins , Dental Implants , Durapatite , Hydroxyapatites , Mandible , Titanium , Wettability , X-Ray Diffraction
5.
Journal of Periodontal & Implant Science ; : 242-247, 2011.
Article in English | WPRIM | ID: wpr-173652

ABSTRACT

PURPOSE: The purpose of this study was to characterize the osseointegration of the fibronectin-coated implant surface. METHODS: Sand-blasted, large-grit, acid-etched (SLA) surface implants, with or without a thin calcium phosphate and fibronectin coating, were placed in edentulous mandibles of dogs 8 weeks after extraction. All dogs were sacrificed forhistological and histomorphometric evaluation after 4- and 8-week healing periods. RESULTS: All types of implants were clinically stable without any mobility. Although the bone-to-implant contact and bone density of the SLA implants coated with calcium phosphate (CaP)/fibronectin were lower than the uncoated SLA implants, there were no significant differences between the uncoated SLA surface group and the SLA surface coated with CaP/fibronectin group. CONCLUSIONS: Within the limits of this study, SLA surfaces coated with CaP/fibronectin were shown to have comparable bone-to-implant contact and bone density to uncoated SLA surfaces.


Subject(s)
Animals , Dogs , Bone Density , Calcium , Calcium Phosphates , Coated Materials, Biocompatible , Dental Implants , Fibronectins , Mandible , Osseointegration
SELECTION OF CITATIONS