Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
The Korean Journal of Orthodontics ; : 268-280, 2018.
Article in English | WPRIM | ID: wpr-716084

ABSTRACT

Resistance to sliding (RS) between the bracket, wire, and ligature has been largely debated in orthodontics. Despite the extensive number of published studies, the lack of discussion of the methods used has led to little understanding of this phenomenon. The aim of this study was to discuss variables affecting RS in orthodontics and to suggest an operative protocol. The search included PubMed©, Medline©, and the Cochrane Library©. References of full-text articles were manually analyzed. English-language articles published between January 2007 and January 2017 that performed an in vitro analysis of RS between the bracket, wire, and ligature were included. Study methods were analyzed based on the study design, description of materials, and experimental setup, and a protocol to standardize the testing methods was proposed. From 404 articles identified from the database search and 242 records selected from published references, 101 were eligible for the qualitative analysis, and six for the quantitative synthesis. One or more experimental parameters were incompatible and a meta-analysis was not performed. Major factors regarding the study design, materials, and experimental setup were not clearly described by most studies. The normal force, that is the force perpendicular to the sliding of the wire and one of the most relevant variable in RS, was not considered by most studies. Different variables were introduced, often acting as confounding factors. A protocol was suggested to standardize testing procedures and enhance the understanding of in vitro findings.


Subject(s)
In Vitro Techniques , Ligation , Methods , Orthodontics
2.
The Korean Journal of Orthodontics ; : 146-154, 2016.
Article in English | WPRIM | ID: wpr-111418

ABSTRACT

OBJECTIVE: Different methods have been utilized to prevent enamel demineralization and other complications during orthodontic treatment. However, none of these methods can offer long-lasting and effective prevention of orthodontic complications or interventions after complications occur. Considering the photocatalytic effect of TiO2 on organic compounds, we hoped to synthesize a novel bracket with a TiO2 thin film to develop a photocatalytic antimicrobial effect. METHODS: The sol-gel dip coating method was used to prepare TiO2 thin films on ceramic bracket surfaces. Twenty groups of samples were composed according to the experimental parameters. Crystalline structure and surface morphology were characterized by X-ray diffraction and scanning electron microscopy, respectively; film thickness was examined with a surface ellipsometer. The photocatalytic properties under ultraviolet (UV) light irradiation were analyzed by evaluating the degradation ratio of methylene blue (MB) at a certain time. Antibacterial activities of selected thin films were also tested against Lactobacillus acidophilus and Candida albicans. RESULTS: Films with 5 coating layers annealed at 700℃ showed the greatest photocatalytic activity in terms of MB decomposition under UV light irradiation. TiO2 thin films with 5 coating layers annealed at 700℃ exhibited the greatest antimicrobial activity under UV-A light irradiation. CONCLUSIONS: These results provide promising guidance in prevention of demineralization by increasing antimicrobial activities of film coated brackets.


Subject(s)
Candida albicans , Ceramics , Crystallins , Dental Enamel , Esthetics , Hope , Lactobacillus acidophilus , Methods , Methylene Blue , Microscopy, Electron, Scanning , Ultraviolet Rays , X-Ray Diffraction
3.
The Korean Journal of Orthodontics ; : 105-112, 2014.
Article in English | WPRIM | ID: wpr-41969

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate the effects of three different surface conditioning methods on the shear bond strength (SBS) of metal brackets bonded directly to gold alloy with chemically cured resin. METHODS: Two hundred ten type III gold alloy specimens were randomly divided into six groups according to the combination of three different surface conditioning methods (aluminum oxide sandblasting only, application of a metal primer after aluminum oxide sandblasting, silica coating and silanation) and thermocycling (with thermocycling, without thermocycling). After performing surface conditioning of specimens in accordance with each experimental condition, metal brackets were bonded to all specimens using a chemically cured resin. The SBS was measured at the moment of bracket debonding, and the resin remnants on the specimen surface were evaluated using the adhesive remnant index. RESULTS: Application of metal primer after aluminum oxide sandblasting yielded a higher bond strength than that with aluminum oxide sandblasting alone (p < 0.001), and silica coating and silanation yielded a higher bond strength than that with metal primer after aluminum oxide sandblasting (p < 0.001). There was no significant change in SBS after thermocycling in all groups. CONCLUSIONS: With silica coating and silanation, clinically satisfactory bond strength can be attained when metal brackets are directly bonded to gold alloys using a chemically cured resin.


Subject(s)
Adhesives , Alloys , Aluminum Oxide , Gold Alloys , Silicon Dioxide
4.
The Korean Journal of Orthodontics ; : 242-247, 2013.
Article in English | WPRIM | ID: wpr-213117

ABSTRACT

OBJECTIVE: To test the null hypothesis that no difference exists between the effects of at-home bleaching and in-office bleaching on shear bond strength (SBS) with bracket bonding at 4 different time intervals after dental bleaching. METHODS: Ninety extracted human premolars were randomly divided into 9 groups (n = 10) according to the bleaching methods used (at-home bleaching and in-office bleaching) and the storage time in artificial saliva (30 min, 1 day, 2 weeks, and 3 weeks before bonding). The control group was stored in artificial saliva for 7 days. Brackets were bonded with the Transbond XT adhesive system, and SBS testing was performed. The adhesive remnant index (ARI) was used to assess the amount of resin remaining on the enamel surfaces after debonding. The SBS data were analyzed by analysis of variance (ANOVA) and the Tukey test. For the ARI, the Kruskal-Wallis test was performed. Significance for all statistical tests was predetermined to be p < 0.05. RESULTS: The SBS of the unbleached group was significantly higher (p < 0.05) than that of the bleached groups (except for the group bonded 30 min after at-home bleaching). CONCLUSIONS: The null hypothesis was not totally rejected. All bleaching groups tested had decreased SBS of the brackets to the enamel, except for the group bonded 30 min after at-home bleaching. The SBS returned to values close to those of the unbleached enamel within 3 weeks following bleaching.


Subject(s)
Humans , Adhesives , Bicuspid , Dental Bonding , Dental Enamel , Orthodontic Brackets , Resin Cements , Saliva, Artificial
5.
The Korean Journal of Orthodontics ; : 127-133, 2013.
Article in English | WPRIM | ID: wpr-150566

ABSTRACT

OBJECTIVE: We aimed to investigate the effects of silanation time on the shear bond strength (SBS) of metal brackets on gold alloy in a silicoating procedure and compare the SBS of metal brackets on gold alloy and enamel. METHODS: Type III gold alloy plates were sandblasted with 30-microm silicon dioxide. Excess particles were removed with gentle air after silica coating, and silane was applied. Maxillary central-incisor metal brackets were bonded to each conditioned alloy surface with a light curing resin adhesive for 1 s, 30 s, 60 s, or 120 s after applying silane. The brackets were also bonded to 36 upper central incisors with the same adhesive. All samples were cured for 40 s with a light emitting diode curing light. The SBS was tested after 1 h and after 24 h. The adhesive remnant index (ARI) of the samples was also compared. RESULTS: The 60-s and 120-s silanation time groups showed a higher SBS than the other groups (p < 0.05). Samples tested after 24 h showed a significantly higher SBS than did the samples tested after 1 h (p < 0.05). The 1-s group showed higher ARI scores. The one-way analysis of variance and Student-Newman-Keuls test showed that the SBS values of the 60-s and 120-s silanation time groups were not significantly different from the SBS values of enamel. CONCLUSIONS: Adequate silanation time is required to produce sufficient bond strength during silicoating.


Subject(s)
Adhesives , Alloys , Enzyme Multiplied Immunoassay Technique , Incisor , Light , Silicon Dioxide
6.
The Korean Journal of Orthodontics ; : 129-137, 2012.
Article in English | WPRIM | ID: wpr-77878

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate the surface roughness (SR) of 2 types of orthodontic archwires made by 4 different manufacturers. METHODS: This in vitro experimental study was conducted on 35 specimens of 7 different orthodontic archwires, namely, 1 nickel-titanium (NiTi) archwire each from the manufacturers American Orthodontics, OrthoTechnology, All-Star Orthodontics, and Smart Technology, and 1 stainless steel (SS) archwire each from the manufacturers American Orthodontics, OrthoTechnology, and All-Star Orthodontics. After analyzing the composition of each wire by energy-dispersive X-ray analysis, the SR of each wire was determined by scanning electron microscopy (SEM) and surface profilometry. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests (alpha < 0.05). RESULTS: The average SR of NiTi wires manufactured by Smart Technology, American Orthodontics, OrthoTechnology, and All-Star Orthodontics were 1,289 +/- 915 Adegrees, 1,378 +/- 372 Adegrees, 2,444 +/- 369 Adegrees, and 5,242 +/- 2,832 Adegrees, respectively. The average SR of SS wires manufactured by All-Star Orthodontics, OrthoTechnology, and American Orthodontics were 710 +/- 210 Adegrees, 1,831 +/- 1,156 Adegrees, and 4,018 +/- 2,214 Adegrees, respectively. Similar to the results of profilometry, the SEM images showed more defects and cracks on the SS wire made by American Orthodontics and the NiTi wire made by All-Star Orthodontics than others. CONCLUSIONS: The NiTi wire manufactured by All-Star Orthodontics and the SS wire made by American Orthodontics were the roughest wires.


Subject(s)
Microscopy, Electron, Scanning , Orthodontics , Stainless Steel
7.
The Korean Journal of Orthodontics ; : 87-93, 2012.
Article in English | WPRIM | ID: wpr-36132

ABSTRACT

OBJECTIVE: The purpose of this study was to investigate the antimicrobial effect of silverized elastomers on mutans streptococci in dental plaque. METHODS: Forty patients undergoing orthodontic treatment were randomly placed into 1 of 2 groups. We examined the maxillary right and left central incisors and premolars, and the mandibular right and left canines of all participants. We ligated the right maxillary and left mandibular teeth of the participants in group 1 with silverized elastomers and ligated their contralateral teeth with conventional elastomers. We ligated the left maxillary teeth and right mandibular teeth of group 2 participants with silverized elastomers. Each participant visited the clinic 4 times at 3-week intervals. We applied the elastomers to the teeth on one side of each patient's mouth during their first visit. During the second visit, the elastomers were removed for microbiological analysis and replaced with steel ligatures. During the third visit, we used silverized elastomers to ligate the teeth contralateral to those treated on the first visit. The elastomers were removed during the fourth visit, and microbiological analyses were performed. We compared the quantity of bacteria on silverized and conventional elastomers at the 0.05 level of significance. RESULTS: The percentage of mutans streptococci was not significantly different in cultures of dental plaque from the silverized and the conventional elastomers (p > 0.05). CONCLUSIONS: There was no significant difference between the antimicrobial effect of the silverized elastomers and that of the conventional elastomers.


Subject(s)
Humans , Bacteria , Bicuspid , Dental Plaque , Elastomers , Incisor , Ligation , Mouth , Silver , Steel , Tooth
SELECTION OF CITATIONS
SEARCH DETAIL