1.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 25-31, 2023.
Article in Chinese | WPRIM | ID: wpr-953741

ABSTRACT

@#Objective     To recognize the different phases of Korotkoff sounds through deep learning technology, so as to improve the accuracy of blood pressure measurement in different populations. Methods     A classification model of the Korotkoff sounds phases was designed, which fused attention mechanism (Attention), residual network (ResNet) and bidirectional long short-term memory (BiLSTM). First, a single Korotkoff sound signal was extracted from the whole Korotkoff sounds signals beat by beat, and each Korotkoff sound signal was converted into a Mel spectrogram. Then, the local feature extraction of Mel spectrogram was processed by using the Attention mechanism and ResNet network, and BiLSTM network was used to deal with the temporal relations between features, and full-connection layer network was applied in reducing the dimension of features. Finally, the classification was completed by SoftMax function. The dataset used in this study was collected from 44 volunteers (24 females, 20 males with an average age of 36 years), and the model performance was verified using 10-fold cross-validation. Results     The classification accuracy of the established model for the 5 types of Korotkoff sounds phases was 93.4%, which was higher than that of other models. Conclusion     This study proves that the deep learning method can accurately classify Korotkoff sounds phases, which lays a strong technical foundation for the subsequent design of automatic blood pressure measurement methods based on the classification of the Korotkoff sounds phases.

2.
Journal of Biomedical Engineering ; (6): 249-256, 2023.
Article in Chinese | WPRIM | ID: wpr-981536

ABSTRACT

Hypertension is the primary disease that endangers human health. A convenient and accurate blood pressure measurement method can help to prevent the hypertension. This paper proposed a continuous blood pressure measurement method based on facial video signal. Firstly, color distortion filtering and independent component analysis were used to extract the video pulse wave of the region of interest in the facial video signal, and the multi-dimensional feature extraction of the pulse wave was preformed based on the time-frequency domain and physiological principles; Secondly, an integrated feature selection method was designed to extract the universal optimal feature subset; After that, we compared the single person blood pressure measurement models established by Elman neural network based on particle swarm optimization, support vector machine (SVM) and deep belief network; Finally, we used SVM algorithm to build a general blood pressure prediction model, which was compared and evaluated with the real blood pressure value. The experimental results showed that the blood pressure measurement results based on facial video were in good agreement with the standard blood pressure values. Comparing the estimated blood pressure from the video with standard blood pressure value, the mean absolute error (MAE) of systolic blood pressure was 4.9 mm Hg with a standard deviation (STD) of 5.9 mm Hg, and the MAE of diastolic blood pressure was 4.6 mm Hg with a STD of 5.0 mm Hg, which met the AAMI standards. The non-contact blood pressure measurement method based on video stream proposed in this paper can be used for blood pressure measurement.


Subject(s)
Humans , Blood Pressure/physiology , Blood Pressure Determination/methods , Algorithms , Hypertension/diagnosis , Sexually Transmitted Diseases
3.
Online braz. j. nurs. (Online) ; 21: e20226619, 01 jan 2022. tab
Article in English | LILACS, BDENF | ID: biblio-1413268

ABSTRACT

OBJECTIVE: The study aimed to evaluate how neonatal blood pressure measurement with the oscillometric method is performed by a nursing team, including patient preparation, documentation, materials, and equipment. METHOD: This cross-sectional study was conducted in a neonatal intensive care unit (NICU) through direct observation of procedures performed by nursing staff. A systematic script was used for observation and documentation of the procedure, patient reparation, and handling of equipment. The results were analyzed through inferential statistics. RESULTS: In a total of 150 observations, 60% or more of steps were classified as correct in 13 of the 26 target items. There was no difference between RNs and nurse technicians concerning the procedure´s success rate (p = 0.3933). Blood pressure measurement was obtained in the first attempt, according to the procedure´s adequacy (p <0.0001). CONCLUSION: Published recommendations for oscillometric blood pressure measurement were not followed completely. Continuing education should focus on routine procedures to ensure essential aspects of care.


Subject(s)
Humans , Infant, Newborn , Oscillometry , Blood Pressure Determination , Intensive Care Units, Neonatal , Nursing, Team , Cross-Sectional Studies
4.
Shanghai Journal of Preventive Medicine ; (12): 1074-1078, 2022.
Article in Chinese | WPRIM | ID: wpr-953900

ABSTRACT

ObjectiveTo evaluate the effect of standardized blood pressure measurement in consulting room (SBPM) model on blood pressure screening of non-hypertensive patients in community. MethodsFour communities were randomly selected from Fengxian District of Shanghai, and non-hypertensive patients in the communities were included for screening. Based on the communities, participants were further classified into the intervention group and control group. A one-year intervention study was conducted from January 1, 2021 to December 31, 2021. The intervention group received the intervention measures of standardized measurement, and the control group remained the routine measurement. The distribution of blood pressure values and last digit of the values between the intervention group and control group were tested using Chi-square test and normality test. Then changes in abnormal blood pressure rate before and after the intervention were determined by double difference method. Statistical analysis was performed using SPSS 20.0. ResultsA total of 15 368 participants were included in the intervention group, and 19 811 participants in the control group. After the intervention, range of the last digit of blood pressure values in the intervention group was 9.55%‒10.41%, of which that of systolic and diastolic blood pressure were equally distributed (P=0.932 and 0.871, respectively). The range of the last digit in the control group was 1.31%‒42.58%, of which that of systolic and diastolic blood pressure showed unequal distribution (P<0.001). Through one-year standardized measurement intervention, the abnormal rate of blood pressure in the intervention group was 26.29%, which was 7.61 times as high as that in the control group (OR=7.55, 95%CI: 6.75‒8.57, P<0.001). ConclusionStandardized blood pressure measurement in consulting room is suitable for the screening of blood pressure measurement in community, which has higher data quality than that of routine measurement.

5.
J. pediatr. (Rio J.) ; 96(2): 168-176, Mar.-Apr. 2020. tab, graf
Article in English | LILACS, ColecionaSUS, SES-SP | ID: biblio-1135009

ABSTRACT

Abstract Objective: Blood pressure (BP) references for Brazilian adolescents are lacking in the literature. This study aims to investigate the normal range of office BP in a healthy, non-overweight Brazilian population of adolescents. Method: The Brazilian Study of Cardiovascular Risks in Adolescents (Portuguese acronym "ERICA") is a national school-based study that included adolescents (aged 12 through 17 years), enrolled in public and private schools, in cities with over 100,000 inhabitants, from all five Brazilian macro-regions. Adolescents' height and body mass index (BMI) were classified in percentiles according to age and gender, and reference curves from the World Health Organization were adopted. Three consecutive office BP measurements were taken with a validated oscillometric device using the appropriate cuff size. The mean values of the last two readings were used for analysis. Polynomial regression models relating BP, age, and height were applied. Results: Among 73,999 adolescents, non-overweight individuals represented 74.5% (95% CI: 73.3-75.6) of the total, with similar distribution across ages. The majority of the non-overweight sample was from public schools 84.2% (95% CI: 79.9-87.7) and sedentary 54.8% (95% CI: 53.7-55.8). Adolescents reporting their skin color as brown (48.8% [95% CI: 47.4-50.1]) or white (37.8% [95% CI: 36.1-39.5]) were most frequently represented. BP increased by both age and height percentile. Systolic BP growth patterns were more marked in males when compared to females, along all height percentiles. The same pattern was not observed for diastolic BP. Conclusions: Blood pressure references by sex, age, and height percentiles for Brazilian adolescents are provided.


Resumo Objetivo Referências de pressão arterial (PA) para adolescentes brasileiros estão ausentes na literatura. Este estudo tem como objetivo investigar a variação normal da pressão arterial no consultório em uma população brasileira saudável de adolescentes sem sobrepeso. Método O Estudo dos Riscos Cardiovasculares em Adolescentes (ERICA) é um estudo brasileiro, de âmbito nacional e de base escolar, que incluiu adolescentes (12 a 17 anos) matriculados em escolas públicas e privadas, em cidades com mais de 100.000 habitantes, de todas as cinco macrorregiões brasileiras. A altura e o índice de massa corporal (IMC) dos adolescentes foram classificados em percentis de acordo com a idade e o sexo, sendo adotadas as curvas de referência da Organização Mundial de Saúde. Foram realizadas três medidas consecutivas de PA no consultório com um dispositivo oscilométrico validado, utilizando o manguito de tamanho apropriado. Os valores médios das duas últimas leituras foram utilizados nas análises. Modelos de regressão polinomial relacionando PA, idade e estatura foram aplicados. Resultados Entre os 73.999 adolescentes, os indivíduos sem sobrepeso representaram 74,5% (IC95%: 73,3-75,6) do total, com distribuição similar entre as idades. A maior parte da amostra sem sobrepeso originava-se das escolas públicas, com 84,2% (IC95%: 79,9-87,7), e os sedentários 54,8% (IC95%: 53,7-55,8). Os adolescentes que relataram sua cor de pele como parda (48,8% [IC95%: 47,4-50,1]) e branca (37,8%: [IC 95% 36,1-39,5]) foram os mais representados. A PA aumentou tanto com a idade, quanto com o percentil de altura. Os padrões de aumento sistólico da PA foram mais acentuados no sexo masculino quando comparados ao sexo feminino, em todos os percentis de altura. O mesmo padrão não foi observado para a PA diastólica. Conclusões São fornecidas referências de pressão arterial por sexo, idade e percentil de altura para adolescentes brasileiros.


Subject(s)
Humans , Male , Female , Child , Adolescent , Cardiovascular Diseases , Reference Values , Blood Pressure , Brazil , Body Mass Index , Cross-Sectional Studies , Risk Factors
6.
Chinese Journal of General Practitioners ; (6): 27-31, 2020.
Article in Chinese | WPRIM | ID: wpr-798578

ABSTRACT

Objective@#To survey on the home blood pressure measurement and blood pressure control rate among patients with hypertension in Beijing Yuetan community.@*Methods@#A questionnaire survey was conducted among 504 hypertensive patients, who were visiting Beijing Yuetan Community Health Service Center and selected by convenience-sampling method during June 2018 to January 2019. The status of home blood pressure measurement, the awareness of hypertension, the blood pressure control rate and factors related to not regularly measuring were surveyed.@*Results@#Of the 504 patients, 93.7% (472/504) took regular medication, but only 61.5% (310/504) had regular blood pressure measurements; 92.5% (466/504) had sphygmomanometers at home with electronic type mainly; 89.9% (453/504) patients knew the method of blood pressure measurement, but only 11.5% (52/453) had their sphygmomanometer calibrated. Among those who measured blood pressure, 77.4% (240/310) measured per week. The main reason for not measuring blood pressure regularly was that there was no need to measure blood pressure without any discomfort, accounting for 50.0% (97/194). The office blood pressure control rate (with desktop mercury sphygmomanometer) was 62.3% (314/504); the blood pressure control rate both in the morning and at bed time was 61.3% (73/119), that in the morning was 68.1% (81/119) and at bed time was 75.6% (90/119). The control rates of systolic blood pressure and heart rate by home measurement at morning and bedtime were significantly higher than those by office measurement (χ2=5.02, 9.97, 15.51, 13.72; all P<0.05).@*Conclusions@#The home blood pressure monitoring rate and knowledge level of hypertension among patients with hypertension in Yuetan community are relatively low. There are some differences in blood pressure control rate between office measurement and home measurement. Comprehensive evaluation is needed in the management process, and the treatment plan should be adjusted according to the specific condition of patients.

7.
Ribeirão Preto; s.n; 2020. 71 p. tab.
Thesis in English | LILACS, BDENF | ID: biblio-1451720

ABSTRACT

Background: Blood pressure is the force of blood pushing against a blood vessels traditionally measured non-invasively by auscultation using an aneroid gauge or mercury device. The objective of this study was to determine whether the nursing staff of a Public hospital in Guyana follow international guidelines for the measurement of blood pressure. Since the detection and subsequent management of patients with high blood require that the technique followed by nursing staff who measure patients' blood pressure produces accurate readings. Methods: This was a quantitative, cross sectional study, conducted in the national referral hospital GPHC in Guyana assessing a sample of 137 of the 781 nursing staff working in the five departments of this hospital. Data was collected through the use of a questionnaire developed following the guidelines for non-invasive blood pressure measurement published by Nerengberg 2018, by the researcher and validated by experts in blood pressure measurement technique and research methodology. Results: 5% of the participants was ward managers, 12% was RNM, 35% of the participants was registered nurses, 7%was qualified midwives, 18% of the participants was nursing assistants and 23% of the participants was patient care assistants. Most of the participants i.e. 39.4% had 4-6, years of experience 31.4% had more than 6 years of experience and 29.2% had 0-3ears of experience in their area off work which means that they all had education and experience in blood pressure measurement. When compared to the steps of the blood pressure measurement technique 72% allow the patient to rest for at least five minutes, 82% provided a calm and quiet environment, 37% explain to the patient not to talk during the procedure, 13% ask the patient to keep the legs uncrossed, 10% ask the patient to keep the feet flat on the floor and 31% of the participants ask the patient to keep the back against the chair. Conclusion: None of the nursing staff of GPHC Guyana followed all of the steps in the guidelines for the measurement of non-invasive blood pressure. While 15 of the 26 steps in guideline measured resulted in more than 75% adherence there were 9 of the 26 steps that had a less than 25% adherence by nursing staff. This means that the steps in the blood pressure guidelines are taken without a standardized guideline and so nursing staff.


Antecedentes: A pressão arterial é a força do sangue empurrando os vasos sanguíneos tradicionalmente medida de forma não invasiva por ausculta usando um medidor aneróide ou dispositivo de mercúrio. O objetivo deste estudo foi determinar se a equipe de enfermagem de um hospital público na Guiana segue as diretrizes internacionais para medição da pressão arterial. Já a detecção e posterior manejo de pacientes com hipertensão arterial exigem que a técnica seguida pela equipe de enfermagem que mede a pressão arterial dos pacientes produza leituras precisas. Métodos: Este foi um estudo quantitativo, transversal, realizado no hospital de referência nacional GPHC na Guiana, avaliando uma amostra de 137 dos 781 funcionários de enfermagem que trabalham nos cinco departamentos deste hospital. Os dados foram coletados por meio de questionário desenvolvido seguindo as diretrizes para medição não invasiva da pressão arterial publicadas por Nerengberg 2018, pela pesquisadora e validado por especialistas em técnica de medição de pressão arterial e metodologia de pesquisa. Resultados: 5% dos participantes eram gerentes de enfermaria, 12% eram RNM, 35% dos participantes eram enfermeiros registrados, 7% eram parteiras qualificadas, 18% dos participantes eram auxiliares de enfermagem e 23% dos participantes eram auxiliares de atendimento ao paciente. A maioria dos participantes, ou seja, 39,4% tinham 4-6 anos de experiência, 31,4% tinham mais de 6 anos de experiência e 29,2% tinham 0-3 anos de experiência em sua área fora do trabalho, o que significa que todos tinham formação e experiência em pressão arterial. medição. Quando comparados com as etapas da técnica de aferição da pressão arterial 72% permitem que o paciente descanse por pelo menos cinco minutos, 82% proporcionam um ambiente calmo e tranquilo, 37% explicam ao paciente para não falar durante o procedimento, 13% pedem ao paciente manter as pernas descruzadas, 10% pedem para o paciente manter os pés apoiados no chão e 31% dos participantes pedem para o paciente manter as costas apoiadas na cadeira. Conclusão: Nenhum membro da equipe de enfermagem do GPHC Guiana seguiu todas as etapas das diretrizes para medição da pressão arterial não invasiva. Embora 15 dos 26 passos medidos nas diretrizes tenham resultado em mais de 75% de adesão, houve 9 dos 26 passos que tiveram uma adesão inferior a 25% por parte da equipe de enfermagem. Isso significa que as etapas das diretrizes de pressão arterial são executadas sem uma diretriz padronizada e, portanto, pela equipe de enfermagem.


Subject(s)
Humans , Blood Pressure Determination , Nursing, Team
8.
Rev. bras. enferm ; 72(supl.3): 162-169, 2019. tab
Article in English | BDENF, LILACS | ID: biblio-1057717

ABSTRACT

ABSTRACT Objective: to compare blood pressure values obtained by auscultatory and oscillometric methods in different gestational periods, considering cuff width. Method: it is a cross-sectional and quasi-experimental study approved by the Research Ethics Committee. The sample consisted of 108 low-risk pregnant women. Blood pressure measurements were performed in gestational periods of 10-14, 19-22 and 27-30 weeks. Results: The oscillometric device presented values similar to the auscultatory method in systolic blood pressure, but overestimated diastolic blood pressure. Underestimation of blood pressure occurred when using the standard width cuff rather than the correct width cuff in both measuring methods. Conclusion: Verification of brachial circumference and use of adequate cuffs in both methods are indispensable to obtain reliable blood pressure values in pregnant women. We recommend performance of additional studies to evaluate diastolic blood pressure overestimation by the Microlife 3BTO-A.


RESUMEN Objetivo: Comparar los valores de presión arterial obtenidos por los métodos auscultatorio e oscilométrico en distintos períodos del embarazo, en función del ancho del manguito. Método: Se trata de un estudio transversal y cuasiexperimental aprobado por el Comité de Ética en Investigación. Se analizó una muestra compuesta por 108 embarazadas de bajo riesgo. Las medidas de presión arterial se obtuvieron en los períodos gestacionales de 10-14, 19-22 y 27-30 semanas. Resultados: El aparato oscilométrico presentó valores similares al método auscultatorio en la presión arterial sistólica, sin embargo sobreestimó la presión arterial diastólica. Hubo subestimación de la presión arterial al utilizar el manguito de anchura estándar en lugar del manguito de anchura adecuada, en los dos métodos de medida. Conclusión: La verificación de la circunferencia braquial y el uso de manguitos adecuados en los dos métodos son indispensables para obtener valores confiables de la presión arterial en embarazadas. Recomendamos que se realicen nuevos estudios para evaluar la sobreestimación de la presión arterial diastólica por el aparato Microlife 3BTO-A.


RESUMO Objetivo: Comparar os valores de pressão arterial, obtidos pelos métodos auscultatório e oscilométrico em diferentes períodos gestacionais, em função da largura do manguito. Método: Trata-se de um estudo transversal e quase-experimental aprovado pelo Comitê de Ética em Pesquisa. A amostra foi composta por 108 gestantes de baixo risco. As medidas de pressão arterial foram realizadas nos períodos gestacionais de 10-14, 19-22 e 27-30 semanas. Resultados: O aparelho oscilométrico apresentou valores similares ao método auscultatório na pressão arterial sistólica, porém superestimou a pressão arterial diastólica. Houve subestimação da pressão arterial ao utilizar o manguito de largura padrão ao invés do manguito de largura correta, nos dois métodos. Conclusão: A verificação da circunferência braquial e o uso de manguitos adequados nos dois métodos são indispensáveis para obter valores confiáveis da pressão arterial em gestantes. Recomendamos que novos estudos sejam realizados para avaliar a superestimação da pressão arterial diastólica pelo aparelho Microlife 3BTO-A.


Subject(s)
Humans , Female , Pregnancy , Adult , Oscillometry/instrumentation , Blood Pressure Determination/instrumentation , Pregnant Women , Oscillometry/methods , Oscillometry/standards , Auscultation/instrumentation , Auscultation/methods , Blood Pressure Determination/methods , Blood Pressure Determination/standards , Cross-Sectional Studies , Gestational Age , Middle Aged
9.
Arch. cardiol. Méx ; 88(1): 16-24, ene.-mar. 2018. tab, graf
Article in English | LILACS | ID: biblio-1054984

ABSTRACT

Abstract: Objective: The level of agreement between two blood pressure (BP) reading methods, auscultatory vs oscillometric, was examined using a mercury sphygmomanometer and an electronic device in children and adolescents with different levels of obesity. The readings were compared to determine their impact on the diagnosis of pre-hypertension/hypertension. Methods: Blood pressure readings were taken in children with obesity (body mass index ≥ 95th percentile) and severe obesity (≥120% 95th percentile). Bland-Altman analysis and Intraclass Correlation Coefficient were used to determine the agreement between measurements. Results: The mercury sphygmomanometer readings were lower than those obtained with the electronic device for both systolic and diastolic BP (P = .01 and P = .001, respectively). The mean systolic and diastolic BP differences between the oscillometric vs first mercury reading were 4.2/10.2 mm Hg, respectively. A large difference was observed between the BP measurement methods. The ICC showed regular to moderate reliability for the systolic BP (.595), but poor for the diastolic BP (.330). Screening using the first of three mercury measurements showed that 10.4% of the children and adolescents had BPs within the pre-hypertension/hypertension range. This was reduced to 5.2% when the mean of three mercury readings was used. Conclusions: Large discrepancies were observed in both the systolic and diastolic BP. These differences are not clinically acceptable as to consider the two instruments interchangeable. The electronic device readings were higher, and they overestimated the diagnosis of hypertension. © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma Mèxico S.A. This is an open access article under the CC BY-NC-ND license (https://creativecommons.org/licenses/by-nc-nd/4.0/).


Resumen: Objetivo: Para conocer el grado de concordancia entre 2 métodos de medición de presión arterial (PA), auscultatorio vs oscilométrico se utilizó un esfigmomanómetro de mercurio y un dispositivo electrónico en niños y adolescentes con diferentes grados de obesidad. Las lecturas fueron comparadas para conocer su impacto en el diagnóstico de prehipertensión/hipertensión. Método: Se midió la PA a niños con obesidad (percentil 95 del índice masa corporal) y obesidad severa (120% del percentil 95). Utilizamos análisis de Bland-Altman y Coeficiente de Correlación Intraclase (CCI) para conocer acuerdo entre mediciones. Resultados: Las lecturas con esfigmomanómetro de mercurio fueron más bajas que con el electrónico para la PA sistólica y diastólica (p = 0.01 y 0.001, respectivamente). El promedio de las diferencias en sistólica y diastólica entre oscilométrico vs. primera medición con mercurio fue de 4.2/10.2 mm Hg respectivamente. Se observó una gran diferencia de las mediciones entre los métodos de medición de PA. El CCI mostró una confiabilidad regular a moderada para la sistólica (0.595) pero pobre para la diastólica (0.330). El tamizaje con una medición mediante mercurio mostró que el 10.4% de los niños y adolescentes tenían PA en el rango de prehipertensión/hipertensión, pero se redujo a un 5.2% con el promedio de 3 mediciones. Conclusiones: Se observaron grandes discrepancias en la PA sistólica y diastólica. Tales diferencias no son clínicamente aceptables como para considerar equivalentes los 2 instrumentos. Las mediciones realizadas en este estudio con dispositivo electrónico fueron más altas y sobre estimaron el diagnóstico de hipertensión. © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. Este es un artículo Open Access bajo la licencia CC BY-NC-ND (https://creativecommons.org/licenses/by-nc-nd/4.0/).


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Oscillometry , Auscultation , Blood Pressure Determination/methods , Pediatric Obesity/complications , Hypertension/complications , Hypertension/diagnosis , Cross-Sectional Studies , Sphygmomanometers , Prehypertension/complications , Prehypertension/diagnosis
10.
Chinese Journal of Medical Instrumentation ; (6): 400-404, 2018.
Article in Chinese | WPRIM | ID: wpr-775545

ABSTRACT

In aging society the development of non-invasive continuously blood pressure monitors which are suitable for homes, communities and nursing homes has a wide range of applications. This paper proposes a non-invasive continuously blood pressure monitoring based on wearable device which uses MSP430F5529 as the central processor. The design is divided into signal acquisition module, central control module, display module, power supply module and host computer module. The experimental results showed that DBP (375/390, 96.15%) and SBP estimation values (377/390, 96.67%) are in 95% confidence interval, which means our design passes Bland-Altman test with high accuracy and stability.


Subject(s)
Blood Pressure , Blood Pressure Determination , Blood Pressure Monitors , Electric Power Supplies , Wearable Electronic Devices
11.
REME rev. min. enferm ; 21: e-995, 2017. tab
Article in English, Portuguese | LILACS, BDENF | ID: biblio-907959

ABSTRACT

Objetivou-se identificar como é realizado o procedimento de medida indireta e registro da pressão arterial por profissionais de enfermagem e as condições técnicas dos dispositivos utilizados. Trata-se de estudo quantitativo, observacional, de delineamento transversal. A amostra compôs-se de 80 servidores observados no período de agosto de 2013 a janeiro de 2014, em cinco unidades de saúde de Londrina, Paraná. Na coleta de dados utilizou-se instrumento fundamentado nas VI Diretrizes Brasileiras de Hipertensão e, para o registro do procedimento, instrumento construído conforme recomendações do COREn-SP.Na análise dos dados usou-se o Programa Statistical Package for the Social Science versão1.6. Os resultados mostraram altos índices de “não realização” (93,8 a 100%) das etapas de preparo do paciente para a medida da pressão. A calibração dos equipamentos não era aferida e não havia manguitos disponíveis de tamanhos variados. Concluiu-se que há importantes lacunas nos procedimentos adotados pela enfermagem para a medida da pressão arterial, indicando a necessidade de medidas educativas.


The aim of this study was to identify how the procedure for indirect measurement and recording of blood pressure by nursing professionals isperformed and the technical conditions of the devices used. It is a quantitative, observational, cross-sectional study. The sample consisted of 80servers, observed from August 2013 to January 2014, in five health units in Londrina, Paraná. In the data collection, it was used as a reference tomeasure an instrument made from the steps described in the VI Brazilian Guidelines on Hypertension and, for the record of the proceeding, a toolbuilt according to the recommendations of the COREn, São Paulo. For data analysis, we used the Program Statistical Package for Social Scienceversion 1.6. The results showed high rates of "non-performance" (93.8% to 100%) of the steps for preparing the patient for measurement of pressure. The calibration of the equipment is not measured, and there are not cuffs of varied sizes. It is concluded that there are important gaps related to the practice adopted by nurses to measure blood pressure, indicating the need for implementation of educational measures.


El objetivo del presente estudio fue identificar cómo el personal de enfermería realiza el procedimiento de medición indirecta y registro de la presiónarterial y cuáles son las condiciones técnicas de los dispositivos utilizados. Se trata de un estudio cuantitativo observacional transversal. La muestra estuvo formada por 80 empleados observados de agosto 2013 a enero 2014 en cinco unidades de salud en Londrina, Paraná. En la recogida de datos seutilizó un instrumento basado en las VI Directrices Brasileñas de Hipertensión y, para el registro del procedimiento, un instrumento construido segúnlas recomendaciones del COREn - SP. Para el análisis de datos se utilizó el Programa Statistical Package for the Social Science versión 1.6. Los resultadosmostraron altos índices de "no realización" (93,8% a 100%) de las etapas de preparación del paciente para la medición de la presión, que no se evaluaba la calibración de los equipos y que no había manguitos disponibles de distintos tamaños. Se llegó a la conclusión de que hay deficiencias significativa.


Subject(s)
Humans , Blood Pressure Determination , Hypertension , Nursing Care , Nursing Records
12.
The Korean Journal of Internal Medicine ; : 665-674, 2015.
Article in English | WPRIM | ID: wpr-76677

ABSTRACT

BACKGROUND/AIMS: Ambulatory blood pressure (BP) monitoring has been widely recommended for evaluating the status of BP, but is lacking in practicality. Determination of the specific time points for BP measurement that are representative of 24-hour mean BP could be useful and convenient in hypertensive patients with chronic kidney disease (CKD). METHODS: A total of 1,317 patients for whom 24-hour ambulatory BP monitoring was performed were enrolled in a multicenter study on hypertensive CKD. We analyzed the time points at which systolic blood pressure (SBP) values exhibited the smallest differences from 24-hour mean SBP (mSBP). We included office mSBP and analyzed the relationships between SBPs at the office and the time points with the smallest differences from 24-hour mSBP using several methods. RESULTS: The time points with the smallest differences from 24-hour mSBP were 7:00 AM, 2:00 PM, and 9:30 PM. In regression analysis, SBPs at 7:00 AM and 9:30 PM were better correlated with 24-hour mSBP than SBPs at 2:00 PM and the office. The proportions of patients with SBPs within 30% of 24-hour mSBP were higher at 7:00 AM and 9:30 PM. The best consistency between the uncontrolled hypertensive groups, defined as > or = 135 mmHg of 24-hour mSBP and higher values of SBPs corresponding to 135 mmHg of 24-hour mSBP, were observed at the 7:00 AM and 9:30 PM time points. CONCLUSIONS: The specific time points for SBPs that correlated well with 24-hour mSBP in hypertensive CKD patients were 7:00 AM and 9:30 PM.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Young Adult , Blood Pressure , Blood Pressure Monitoring, Ambulatory/methods , Circadian Rhythm , Cross-Sectional Studies , Hypertension/diagnosis , Office Visits , Predictive Value of Tests , Prospective Studies , Renal Insufficiency, Chronic/diagnosis , Republic of Korea , Time Factors
13.
J. vasc. bras ; 13(1): 27-33, Jan-Mar/2014. tab, graf
Article in English | LILACS | ID: lil-709786

ABSTRACT

INTRODUCTION: The conventional method for measuring the ankle-brachial index (ABI) requires a vascular Doppler machine and a trained professional, which is a barrier to the examination becoming more widely adopted across health services. For this reason, the possibility of substituting Doppler monitors for other types of device has been investigated. The objective of this study was to assess the validity, reliability and accuracy of taking ABI measurement using oscillometric devices and compare them to vascular Doppler. METHODS: This is an integrative literature review of four articles. RESULTS: There was very little uniformity between the four studies in terms of ample populations or the methodological procedures used to measure systolic pressures. The results for sensitivity, specificity and positive and negative predictive values varied and so did measures of reliability. CONCLUSIONS: The results of these studies do not provide a basis from which conclusions can be drawn on the validity, reliability or accuracy of employing oscillometric devices as a substitute for Doppler for determination of ABI. .


INTRODUÇÃO: A necessidade do Doppler vascular e da capacitação profissional para a realização do método convencional para medida do índice tornozelo-braquial (ITB) é uma barreira à disseminação desse tipo de avaliação nos serviços de saúde. Nesse contexto, a substituição do Doppler por outros dispositivos tem sido investigada. O objetivo deste trabalho foi avaliar a validade, a confiabilidade e a acurácia da determinação do ITB com o uso de dispositivo oscilométrico comparado ao Doppler vascular. MÉTODO: Esta revisão integrativa da literatura incluiu quatro artigos. RESULTADOS: Os estudos foram bastante heterogêneos com relação à população estudada e aos procedimentos metodológicos para aferição das pressões sistólicas. Variações nos valores de sensibilidade e especificidade, e valores preditivos positivo e negativo foram observadas, assim como nas medidas de confiabilidade. CONCLUSÃO: Os resultados dos estudos não permitiram tecer conclusões acerca da validade, da confiabilidade e da acurácia da utilização do dispositivo oscilométrico em substituição ao Doppler, para determinação do ITB. .


Subject(s)
Humans , Middle Aged , Databases, Bibliographic , Blood Pressure Determination/nursing , Peripheral Arterial Disease , Ankle Brachial Index/methods , Lower Extremity , Quality of Life
14.
Malaysian Journal of Public Health Medicine ; : 48-64, 2013.
Article in English | WPRIM | ID: wpr-626607

ABSTRACT

A cross-sectional study was carried out in July-October 2012 in UKM to remeasure, evaluate and compare the changes in health services utilization level among women staff in UKM with a previous study done in 2001 and its influencing factors. The services studied were blood pressure (BP) measurement and Pap smear test. A total of 234 respondents aged between 18 and 55 were selected using stratified random sampling from Bangi, Kuala Lumpur and UKMMC, Malaysia. Data was collected via self-administered questionnaire and was analyzed by using SPSS version 17.0. Majority 85.9% of the respondents were found to have utilized at least one BP measurement which is higher compared to previous study. The Pap smear test, 64.5% of women have had a Pap smear test done also higher compared to previous study. Multivariate analysis shows the factors associated with BP measurement are age (OR 2.7, CI 95% 1.2, 6.3), family history of general health problems (OR 3.4, CI 95% 1.5, 7.6), and health staff influence (OR 5.2, CI 95% 1.1, 25.5). The factors associated with Pap smear test are marital status (OR 62.8, CI 95% 7.2, 546.4), general health problems (OR 2.3, CI 95% 1.2, 4.5), family planning (OR 6.9, CI 95% 3.0, 16.5) and self-interest (OR 3.3, CI 95%, 1.3, 8.6). The level of health services utilization on BP measurement and Pap smear test in 2012 is higher than 2001. For both BP measurement and Pap smear test the determinant factors are differed in the aforesaid years.

15.
Rev. bras. hipertens ; 19(4): 95-98, out.-dez.2012.
Article in Portuguese | LILACS | ID: biblio-881717

ABSTRACT

As controvérsias sobre os padrões pressóricos durante a gravidez normal justificam a realização de estudos para melhor entender a questão. O objetivo deste estudo foi conhecer as variações normais da pressão arterial (PA), através da monitorização ambulatorial da pressão arterial (MAPA), em gestantes saudáveis numa capital da região norte do Brasil. Foram estudadas 89 gestantes normotensas, nulíparas ou multíparas, de 3 centros obstétricos da cidade de Belém (PA). As gestantes foram divididas em três grupos, segundo a idade gestacional: Grupo 1, composto por 25 grávidas, entre 6 e 13 semanas de gestação; Grupo 2, por 32 grávidas, entre 14 e 25 semanas; e Grupo 3, por 32 grávidas, entre 28 e 38 semanas de gestação. As 89 gestantes apresentavam idade entre 18 e 35 anos (mediana de 24 anos). Não houve diferenças significantes entre o número de nulíparas e multíparas (p = 0,5555). Quanto às variáveis da MAPA analisadas (média de 24 horas) houve diferenças estatisticamente significantes apenas em três delas: PA sistólica no Grupo 3 (aumento), PA diastólica no Grupo 2 (redução) e descenso noturno diastólico no Grupo 1 (aumento). Podemos concluir que em grávidas normotensas, os parâmetros da MAPA avaliados tiveram comportamento similar aos padrões de normalidade considerados para a população geral.


Controversies regarding blood pressure patterns during normal pregnancy justify studies for their better understanding. The objective of this study was to verify normal blood pressure (BP) variations by means of ambulatory blood pressure monitoring (ABPM) in healthy pregnant women in the capital of a northern Brazilian state. A total of 89 normotensive nulliparous or multiparous pregnant women from 3 obstetric centers in the city of Belém ­ State of Pará, were studied. The pregnant women were divided into three groups, according to their gestational age: Group 1, comprising 25 pregnant women between 6 and 13 weeks of gestation; Group 2, with 32 pregnant women between 14 and 25 weeks of gestation; and Group 3, with 32 pregnant women between 28 and 38 weeks of gestation. The ages of the 89 pregnant women ranged from 18 to 35 years (median of 24,0 years). There was no significant difference between the number of nulliparae and multiparae (p = 0.5555). As regards the ABPM variables analyzed (mean of 24 hours), statistically significant differences were observed in only three of them: systolic BP in Group 3 (increase); diastolic BP in Group 2 (decrease), and diastolic nocturnal dip in Group 1 (increase). In conclusion, in normotensive pregnant women the variation of the ABPM parameters analyzed was similar to the normal patterns observed in the general population.


Subject(s)
Humans , Female , Pregnancy , Adolescent , Adult , Blood Pressure Monitoring, Ambulatory , Data Interpretation, Statistical
16.
Chinese Journal of Emergency Medicine ; (12): 1367-1370, 2012.
Article in Chinese | WPRIM | ID: wpr-430606

ABSTRACT

Objective To investigate the relationship between noninvasive brachial artery blood pressure (B) and radial artery blood pressure (R) of the right arm.Methods Two hundred and ninetyfive patients with 149 males and age of (47 ± 16) years were studied.The height of patients was 163 ± 8 cm,and weight of patients was (61.2 ± 7.8) kg.The patients with peripheral vascular disease,wounds of arm skin or subcutaneous tissue infection were all excluded.Their B (with adult cuffs) and R (with infant cuffs) of the right arm were measured and analyzed after the patients under general anesthesia and stable hemodynamics.The relationships between B and R were analyzed by linear regression,the differences between B and R of each interval were compared using one-way ANOVA and then followed by SNK procedure.Results Right brachial artery blood pressure was significantly lower than radial artery blood pressure.The differences between the two varied from 13 to 18 mmHg in systolic BP (SBP),diastolic BP (DBP) and mean blood pressure (MAP).And linear regression was most applicable to describe their correlation [r=0.841 (SBP),0.808 (DBP),0.833 (MAP),all P<0.01].Conclusions Radial artery blood pressure measured with infant cuffs can well reflect the variation of brachial artery blood pressure.

17.
Indian J Med Sci ; 2011 Sept; 65(9) 406-410
Article in English | IMSEAR | ID: sea-145698

ABSTRACT

Guidelines for measuring blood pressure includes measurement of blood pressure on both arms but it is often ignored. Our case report aims at highlighting the need follow the guidelines. A 60 year old 59 kg weighing male asymptomatic patient without any comobidities was posted for bilateral inguinal hernia repair. The interarm blood pressure difference was discovered incidentally during his preanaesthetic evalution. On further evaluation patient was found to be having subclavian stenosis on left side which was asymptomatic. Intraoperative and post operative period was uneventful. Blood pressure measurement should be done in accordance with the stipulated guidelines. Inter arm blood pressure difference should be noted in all patients as not only for diagnosis and treatment of hypertension but also as a tool to diagnose asymptomatic peripheral vascular disesase.


Subject(s)
Aged , Arm/physiology , Blood Pressure/physiology , Blood Pressure Determination/methods , Blood Pressure Determination/standards , Hernia, Inguinal/surgery , Humans , Hypertension/epidemiology , Hypertension/diagnosis , Male , Peripheral Vascular Diseases/epidemiology , Peripheral Vascular Diseases/diagnosis
18.
Clinics ; 63(1): 43-50, 2008. ilus, graf, tab
Article in English | LILACS | ID: lil-474927

ABSTRACT

OBJECTIVE: To compare blood pressure measurements taken at home by physicians, nurses, and patients with office blood pressure measurement , ambulatory blood pressure monitoring and home blood pressure measurement. METHODS: A total of 44 patients seen by a home care program were studied. Protocol 1 a) blood pressure was measured by the patient, a physician and a nurse during a regular home visit (Home1); b) home blood pressure measurement was measured for 4 days (HBPM1); c) office blood pressure measurement was measured by a physician, a nurse, and the patient; and by 24-hour ambulatory blood pressure monitoring. Protocol 2 blood pressure was measured by the patient, a physician, and a nurse during a special home visit in the presence of a physician and a nurse only (Home2); and b) home blood pressure measurement was taken for the second time (HBPM2). Echocardiography, guided by a two-dimensional echocardiograph, was performed. RESULTS: Protocol 1: a) office blood pressure measurement and Home1 were significantly higher than ambulatory blood pressure monitoring, except for systolic and diastolic office blood pressure measurement taken by the patient or a family member, systolic blood pressure taken by a nurse, and diastolic blood pressure taken by a physician. b) ambulatory blood pressure monitoring and HBPM1 were similar. Protocol 2: a) HBPM2 and Home2 were similar. b) Home2 was significantly lower than Home1, except for diastolic blood pressure taken by a nurse or the patient. There were significant relationships between: a) diastolic blood pressure measured by the patient and the thickness of the interventricular septum, posterior wall, and left ventricular mass; and b) ambulatory and HBPM2 diastolic and systolic blood pressure taken by a physician (home2) and left ventricular mass. Therefore, the data indicate that home blood pressure measurement and ambulatory blood pressure monitoring had good prognostic values relative to "office...


Subject(s)
Humans , Blood Pressure Determination/methods , Home Care Services , Hypertension/diagnosis , Physicians' Offices , Blood Pressure Monitoring, Ambulatory , Echocardiography , Hypertension/psychology , Multivariate Analysis
19.
Chinese Journal of Hypertension ; (12)2007.
Article in Chinese | WPRIM | ID: wpr-589124

ABSTRACT

18 years of age were enrolled. The blood pressure measurements at the wrist were compared with the results obtained by auscultatory measurement on left upper arm. Both measurements were taken 3 times in each person. A total 273 measurements were obtained in 91 participants. The evaluation of the accuracy was assessed by 2 statistical methods. (1)The differences between the 2 devices for a given measurement. (2) The differences between the 2 devices for a given person. Results Method 1 showed the sample mean errors and standard deviation of errors were 0.5?7.1 mm Hg for systolic blood pressure(SBP) and -1.6?6.1 mm Hg for diastolic blood pressure(DBP). Method 2 showed they were 0.5?6.1 mm Hg for SBP and -1.6?5.3 mm Hg for DBP. Blood pressure level and the wrist circumferences had no influence on the measurement errors. Conclusion The HEM-6000 wrist blood pressure device apparently met the AAMI criteria and is valid for patient self-measurement.

20.
Chinese Journal of Hypertension ; (12)2007.
Article in Chinese | WPRIM | ID: wpr-588464

ABSTRACT

Objective The aim of this study was to assess the distribution histogram of arm circumference (AC) in adult hypertensives in Beijing area, and to establish which size of cuffs is most appropriate in clinical practice. Methods We conducted a cross-sectional survey in a cohort of 424 (male 61.6%) consecutive hypertensives patients. Arm circumference was measured at the mid-point of the right upper arm. Subjects were stratified in three groups: group 1 with AC between 22-26 cm (small size), group 2 AC between 27-34 cm(medium size), and group 3 AC great than 34 cm (large size). Using AC of 32 cm as cutoff point, patients were subdivided as group A (AC