Chinese Journal of Digestive Endoscopy ; (12): 65-70, 2022.
Article in Chinese | WPRIM | ID: wpr-934077

ABSTRACT

Objective To investigate the diagnostic value of blue light imaging-bright (BLI-bright) and linked color imaging (LCI) for early esophageal cancer (EEC).Methods:Data of 63 consecutive patients with EEC who underwent gastroscopy under BLI-bright, LCI and white-light imaging (WLI) and endoscopic submucosal dissection (ESD) from May 2018 to August 2020 at Fuding Hospital Affiliated to Fujian University of Traditional Chinese Medicine were analyzed retrospectively in the cohort study. Subjective visibility analysis was performed by 6 endoscopists who were divided into 2 groups (expert group and trainee group) with 3 endoscopists in each group. The main observation index was the visibility score (ranking score, RS). The objective color difference (Δ E) between lesions of EEC and surrounding mucosa under 3 modes were analyzed by using the L *a *b * color space. Results:The overall RS of 6 endoscopists under WLI mode (2.57±0.81) was significantly lower than that under LCI (3.25±0.67) ( t=9.71, P<0.001) and BLI-bright (3.18±0.67) ( t=9.31, P<0.001). In the expert group, the RS of WLI (2.71±0.80) was significantly lower than that of LCI (3.33±0.66) ( t=7.16, P<0.001) and BLI-bright (3.42±0.62) ( t=8.09, P<0.001). In the trainee group, the RS of WLI (2.40±0.90) was also significantly lower than that of LCI (3.15±0.83) ( t=9.62, P<0.001) and BLI-bright (2.89±0.92) ( t=5.69, P<0.001), and the RS of LCI was higher than that of BLI-bright ( t=4.07, P<0.001). The Δ E between lesions of EEC and surrounding mucosa under WLI (11.52±3.40) was significantly lower than that under LCI (16.64±4.70) ( t=7.10, P<0.001) and BLI-bright (15.72±3.84) ( t=7.88, P<0.001). Conclusion:BLI-bright and LCI can effectively improve EEC visibility and color difference between EEC and surrounding mucosa. Furthermore, LCI is more conducive to the detection of EEC for the trainees.

2.
Chinese Journal of Internal Medicine ; (12): 310-316, 2022.
Article in Chinese | WPRIM | ID: wpr-933453

ABSTRACT

Objective:To evaluate the clinical application of LASEREO endoscopic system in early gastric cancer (EGC).Methods:A total of 68 patients diagnosed with EGC were retrospectively analyzed between August 2017 to December 2020 in Fuding Hospital Affiliated to Fujian University of Traditional Chinese Medicine. There were 50 males and 18 females finally enrolled with a median age of 64 years. EGCs were analyzed from subjective and objective aspect, as well as from magnification and non-magnification status. Six endoscopists evaluated the visibility of the EGC (RSC) and calculated the color difference (ΔEC) between EGC and the surrounding mucosa in white light imaging (WLI), blue light imaging-bright (BLI-Bri) and linked color imaging (LCI) modes. In the case of magnification (×80), the visibility of the microstructures and microvessels (RSV) was analyzed and the color difference (ΔEV) between microvessels and non-vessels areas were calculated in WLI, BLI and LCI modes. The visibility was evaluated using visibility ranking scale(RS) and the color difference (ΔE) was calculated using L*a*b* color space.Results:In WLI, BLI-Bri, and LCI modes, the mean (±SD) RSC were 2.56±0.68, 2.63±0.59 and 3.17±0.50, and the mean(±SD) ΔEC were 15.71±5.58, 12.04±3.73, and 22.84±8.46, respectively, which in LCI were higher than those in WLI and BLI-Bri modes ( P<0.001).Regarding the data evaluated by senior endoscopists, the RSC was higher in BLI-Bri than that in WLI mode (2.98±0.58 vs. 2.79±0.73, P<0.001), but as to those evaluated by junior endoscopists, there were no significant differences between the WLI and BLI-Bri modes(2.29±0.72 vs. 2.23±0.72,P =0.218).In magnifying endoscopy with WLI, BLI, and LCI modes, the mean(±SD) RSV were 2.95±0.28, 3.46±0.40, and 3.38±0.33, and the mean (±SD) ΔEV were 21.68±7.52, 44.29±10.94, and 45.38±14.29, respectively.The RSV and ΔEV in LCI and BLI were higher than that in WLI mode ( P<0.001). Conclusions:LCI improves the visibility of EGC by increasing ΔEC, especially in junior endoscopists. Both BLI and LCI improve the visibility of microstructures and microvessels under magnification.

3.
Gut and Liver ; : 140-148, 2019.
Article in English | WPRIM | ID: wpr-763836

ABSTRACT

A laser endoscopy system was developed in 2012. The system allows blue laser imaging (BLI), BLI-bright, and linked color imaging (LCI) to be performed as modes of narrow-band light observation; these modes have been reported to be useful for tumor detection and characterization. Furthermore, an innovative endoscopy system using four-light emitting diode (LED) multilight technology was released in 2016 to 2017 in some areas in which laser endoscopes have not been approved for use, including the United States and Europe. This system enables blue light imaging (this is also known as BLI) and LCI with an LED light source instead of a laser light source. Several reports have shown that these modes have improved tumor detection. In this paper, we review the efficacy of BLI and LCI with laser and LED endoscopes in tumor detection and characterization.