Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add filters








Language
Year range
1.
Article in English | IMSEAR | ID: sea-163362

ABSTRACT

Aim: The aim of the present investigation was to perform the precolumn derivatization of Amantadine Hydrochloride (AMT) with phenylisothiocyanate and to develop a RP-HPLCPDA method for the quantification of Amantadine Hydrochloride-phenylisothiocyanate (AMT-PITC) complex in bulk and dosage forms which is rapid, sensitive and economical. Study Design: Method development and Validation study. Methodology: A Phenomenex C18 RP column of 250 x 4.6mm dimensions and 5μm particle size with mobile phase containing water and acetonitrile (40:60% v/v) was used at isocratic mode binary pump and eluent was monitored at 273nm. Results & Discussion: The retention time of AMT-PITC complex was 6.3 min. The developed method showed a good linearity in the concentration range of 10-50μg/mL with a correlation coefficient >0.998. The recoveries ranged between 95-105% with a Relative Standard Deviation of (RSD) < 2%. Conclusion: The developed method was validated as per ICH guidelines and successfully used for quantification of AMT by derivatization with PITC. The method was found to be rapid, specific and accurate.

2.
Article in English | IMSEAR | ID: sea-151581

ABSTRACT

The aim of the present work was to develop and validate a simple, efficient, economical and LC-MS compatible method for the analysis of Terbutaline sulphate in bulk, dosage forms and in dissolution samples of Terbutaline sulphate tablets by reverse phase high pressure liquid chromatography. A C18 reverse phase column (Phenomenex) of 250 x 4.6mm dimensions and 5μm particle size with mobile phase containing 15mM ammonium acetate: methanol (70:30% v/v) was used at isocratic mode binary pump and eluents were monitored at 220nm. The retention time of Terbutaline sulphate was 4.1min and showed a good linearity in the concentration range of 2-10μg/mL with a correlation coefficient >0.999. The validation characteristics included specificity, linearity, and limit of detection, limit of quantification, precision, robustness and stability. Validation acceptance criteria were met in all cases. The percent recoveries ranged between 98-102%, RSD < 2%. The method could be successfully used for the analysis of Terbutaline sulphate in bulk, dosage forms and in dissolution samples of marketed Terbutaline sulphate tablets.

3.
Article in English | IMSEAR | ID: sea-152858

ABSTRACT

A Simple, efficient and reproducible reverse phase high performance liquid chromatographic method was developed and validated for the Simultaneous determination of Escitalopram oxalate and Clonazepam in combined dosage form. The separation was effected on a Hypersil ODS C18 column (250mm X 4.6mm; 5μ) using a mobile phase mixture of buffer and acetonitrile in a ratio of 50:50 v/v at a flow rate of 1.0ml/min. The detection was made at 240nm. The retention time of Escitalopram oxalate and Clonazepam was found to be 2.840± 0.007min and 4.007±0.006 min. Calibration curve was linear over the concentration range of 20-120μg/ml and 1-6μg/ml for Escitalopram oxalate and Clonazepam. All the analytical validation parameters were determined and found in the limit as per ICH guidelines, which indicates the validity of the method. The developed method is also found to be precise, accurate, specific, robust and rapid for the simultaneous determination of Escitalopram oxalate and Clonazepam in tablet dosage forms.

4.
Article in English | IMSEAR | ID: sea-152831

ABSTRACT

A reverse phase high performance liquid chromatographic method was developed for the determination of dulox-etine hydrochloride in bulk and dosage form. The separation was effected on a kromasil ODS C18 column (250mmX4.6mm, 5μ) using a mobile phase mixture of buffer and methanol in a ratio of 85:15 v/v at a flow rate of 1.0ml/min. The detection was made at 230nm. The retention time of duloxetine hydrochloride was found to be 3.443±0.06 min. Calibration curve was linear over the concentration range of 20-120μg/ml of duloxetine hydrochlo-ride. The propose method was validated as per the ICH guidelines. The method was accurate, precise, specific and rapid found to be suitable for the quantitative analysis of the drug and dosage form.

5.
Article in English | IMSEAR | ID: sea-152824

ABSTRACT

A reverse phase high performance liquid chromatographic method was developed for the determination of Modafinil in bulk and dosage form. The separation was effective on a Hypersil ODS C18 column (250 mm x 4.6 mm; 5μ) using a mobile phase mixture of Buffer:Acetonitrile in a ratio of 55:45 (v/v) at a flow rate of 1.0ml/min. The detection was made at 220nm. The retention time of modafinil was found to be 4.80±0.06 min. Calibration curve was linear over the concentration range of 20-120μg/ml of modafinil. The proposed method was validated as per the ICH guidelines. The method was accurate, precise, specific and rapid and thus found to be suitable for the quantitative analysis of modafi-nil in the bulk and dosage form.

6.
Article in English | IMSEAR | ID: sea-167853

ABSTRACT

A Simple, efficient and reproducible reverse phase high performance liquid chromatographic method was developed and validated for the Simultaneous determination of Escitalopram oxalate and Clonazepam in combined dosage form. The separation was effected on a Hypersil ODS C18 column (250mm X 4.6mm; 5μ) using a mobile phase mixture of buffer and acetonitrile in a ratio of 50:50 v/v at a flow rate of 1.0ml/min. The detection was made at 240nm. The retention time of Escitalopram oxalate and Clonazepam was found to be 2.840± 0.007min and 4.007±0.006 min. Calibration curve was linear over the concentration range of 20-120μg/ml and 1-6μg/ml for Escitalopram oxalate and Clonazepam. All the analytical validation parameters were determined and found in the limit as per ICH guidelines, which indicates the validity of the method. The developed method is also found to be precise, accurate, specific, robust and rapid for the simultaneous determination of Escitalopram oxalate and Clonazepam in tablet dosage forms.

7.
Article in English | IMSEAR | ID: sea-167838

ABSTRACT

A reverse phase high performance liquid chromatographic method was developed for the determination of dulox-etine hydrochloride in bulk and dosage form. The separation was effected on a kromasil ODS C18 column (250mmX4.6mm, 5μ) using a mobile phase mixture of buffer and methanol in a ratio of 85:15 v/v at a flow rate of 1.0ml/min. The detection was made at 230nm. The retention time of duloxetine hydrochloride was found to be 3.443±0.06 min. Calibration curve was linear over the concentration range of 20-120μg/ml of duloxetine hydrochlo-ride. The propose method was validated as per the ICH guidelines. The method was accurate, precise, specific and rapid found to be suitable for the quantitative analysis of the drug and dosage form.

8.
Article in English | IMSEAR | ID: sea-167834

ABSTRACT

A reverse phase high performance liquid chromatographic method was developed for the determination of Modafinil in bulk and dosage form. The separation was effective on a Hypersil ODS C18 column (250 mm x 4.6 mm; 5μ) using a mobile phase mixture of Buffer:Acetonitrile in a ratio of 55:45 (v/v) at a flow rate of 1.0ml/min. The detection was made at 220nm. The retention time of modafinil was found to be 4.80±0.06 min. Calibration curve was linear over the concentration range of 20-120μg/ml of modafinil. The proposed method was validated as per the ICH guidelines. The method was accurate, precise, specific and rapid and thus found to be suitable for the quantitative analysis of modafi-nil in the bulk and dosage form.

SELECTION OF CITATIONS
SEARCH DETAIL