1.
Eng. sanit. ambient ; 22(1): 179-186, jan.-fev. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-840387

ABSTRACT

RESUMO No Brasil, cerca de 32.700 postos de lavagem de veículos consomem 3,7 milhões de m3/mês-1, média de 60 L por veículo. Esse consumo poderia ser minimizado, se o efluente fosse devidamente tratado e reutilizado. Como diversos tipos de efluentes têm sido eficientemente tratados por técnicas eletroquímicas, como a eletrocoagulação (EC) e a eletroflotação (EF), o objetivo principal deste estudo foi desenvolver um sistema de tratamento de efluentes de lavagem de carros por EC, usando eletrodos de alumínio. Parâmetros como pH inicial, corrente elétrica aplicada e tempo de eletrólise foram otimizados por meio de análises físico-químicas e estatísticas. Em sua condição ótima, pH 5, corrente elétrica de 3,5 A e tempo de 20 minutos, o sistema conseguiu reduzir em 73% a demanda química de oxigênio (DQO), 58% de surfactantes e no mínimo 90% a turbidez e os sólidos suspensos totais (SST). Além da simples implantação e operação, a técnica mostrou-se eficiente na recuperação desse tipo de efluente, podendo ser utilizada em sistemas de reúso de água de lavagem de veículos.


ABSTRACT In Brazil, about 32,700 vehicle washing stations consume 3,7 million m3 per month-1, average of 60 L per vehicle. Consumption could be minimized if the effluent was properly treated and reused. As different types of effluents have been effectively treated by electrochemical techniques, such as electrocoagulation (EC) and electrocoagulation (EF), the main objective of this study was to develop a treatment system of carwash wastewater, by EC using electrodes aluminum. Parameters like the initial pH, applied electric current and electrolysis time were optimized by means of physical-chemical analysis and statistics. In its optimum condition, pH 5, electrical current of 3,5 A and time of 20 minutes, the system has managed to reduce by 73% the chemical oxygen demand (COD), 58% of surfactants and a minimum of 90% turbidity and total suspended solids (TSS). Besides the simple installation and operation, the technique was efficient in the recovery of this type of effluent and can be used in reuse system carwash water.

2.
Braz. j. microbiol ; 40(1): 48-53, Jan.-Mar. 2009. ilus, tab
Article in English | LILACS | ID: lil-513114

ABSTRACT

The performance of an anaerobic baffled reactor (ABR) was evaluated in the treatment of cassava wastewater, a pollutant residue. An ABR divided in four equal volume compartments (total volume 4L) and operated at 35ºC was used in cassava wastewater treatment. Feed tank chemical oxygen demand (COD) was varied from 2000 to 7000 mg L-1 and it was evaluated the most appropriated hydraulic retention time (HRT) for the best performance on COD removal. The ABR was evaluated by analysis of COD (colorimetric method), pH, turbidity, total and volatile solids, alkalinity and acidity. Principal component analysis (PCA) was carried to better understand data obtained. The system showed buffering ability as acidity decreased along compartments while alkalinity and pH values were increased. There was particulate material retention and COD removal varied from 83 to 92% for HRT of 3.5 days.


O desempenho de um reator anaeróbio compartimentado (RAC) foi avaliado para o tratamento da manipueira, resíduo tóxico. Um RAC dividido em quatro compartimentos de mesmo volume (volume total 4L) e operado a 35ºC foi utilizado no tratamento da manipueira. A demanda química de oxigênio (DQO) do tanque de alimentação variou de 2000 a 7000 mg L-1 e avaliou-se o tempo de residência hidráulica (TRH) mais apropriado ao melhor desempenho do reator. O RAC foi avaliado pelas análises de DQO (método colorimétrico), pH, turbidez, sólidos totais e voláteis, alcalinidade e acidez. A Análise das Componentes Principais (PCA) foi conduzida para melhor compreensão dos dados obtidos. O sistema apresentou capacidade tamponante conforme a acidez decresceu ao longo dos compartimentos ao passo que a alcalinidade e o pH aumentaram. Houve retenção do material particulado e a remoção da DQO variou de 83 a 92% para TRH de 3,5 dias.


Subject(s)
Biological Oxygen Demand Analysis/analysis , Anaerobic Digestion/analysis , Upflow Anaerobic Reactors/analysis , Toxic Wastes/analysis , Colorimetry/methods , Methods , Methods