Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Chinese Journal of Radiological Health ; (6): 626-631, 2023.
Article in Chinese | WPRIM | ID: wpr-1006317

ABSTRACT

Objective To preliminarily compare 6LiF-7LiF and CR39 in individual neutron dose monitoring, and to provide a reference for improving individual neutron dose monitoring. Methods According to the GBZ 128-2019, 26 radiation workers from 7 institutions received individual neutron dose monitoring with 6LiF-7LiF and CR39 at the same time. The monitoring results were analyzed. Results For most of the workers, the personal neutron dose equivalent Hp(10) was less than the minimum detectable level. The results with the two monitoring methods differed in 6 of 26 workers. Conclusion Both 6LiF-7LiF and CR39 monitoring methods can be used for individual neutron dose monitoring for radiation workers, but the difference between 6LiF-7LiF and CR39 (in threshold energy, energy response, etc.) should be considered so that different types of radiation workers receive appropriate individual neutron dose monitoring.

2.
Article in English | IMSEAR | ID: sea-178623

ABSTRACT

Context: It has been proved from many epidemiological studies that the inhalation of the radioactive, inert gas radon (222Rn) is the main cause of lungs cancer after smoking. Objective: The survey was conducted to estimate the indoor radon concentration, the annual effective dose rate and the annual dose equivalent rate to the lung. Material and Methods: Altogether 50 dwellings were chosen randomly at 5 different districts of Nepal. The dosimetric measurements were carried out over a period of 3 months using time-integrated passive radon detectors, CR-39 based on type II Solid State Nuclear Track Detector (SSNTD) technique. The type of houses was concrete with plastered walls and mud house. Results: The minimum concentration of radon in the study areas was found to be <20Bq.m-3 and the maximum concentration was 110±20Bq.m-3. Also the corresponding values of annual effective dose and annual equivalent dose to the lung respectively varied from <0.60 to 3.30mSv.y-1 and 0.16×10-7 to 0.88×10-7 Sv.y-1. The uncertainty was measured at 95% confidence level. Conclusion: The indoor radon concentration varies considerably with the ventilation condition, lifestyle of the people, construction of the dwellings and climate of the areas. The measurements show that the radon concentrations were found to be well below the reference levels of ICRP.

3.
Journal of the Korean Ophthalmological Society ; : 909-914, 1995.
Article in Korean | WPRIM | ID: wpr-39408

ABSTRACT

Prisms have been used as tools with which to treat and diagnose many diseases in strabismology. But, because of prismatic distortion and dispersion, the visual acuities are declined. The purpose of this study is to show the relationship between prismatic effect and visual acuity degradation. Visual acuities were measured through a series of prisms of CR-39 to quantify the blur induced by prism. The mean visual acuities of myopias and amblyopias(with or without correction), and emmetropias were reduced as prism diopters were increased. The declines were linear. There was no significant difference among the declines of visual acuities of each group. Whenever to prescribe prisms and to test with prisms, we should remind that prisms could reduce visual acuities.


Subject(s)
Emmetropia , Myopia , Visual Acuity
SELECTION OF CITATIONS
SEARCH DETAIL