Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
Chinese Journal of Radiological Health ; (6): 35-39, 2023.
Article in Chinese | WPRIM | ID: wpr-965369

ABSTRACT

@#<b>Objective</b> To compare the effects of different respiratory signal acquisition methods on the delineation of moving tumor targets. <b>Methods</b> A cube phantom containing a sphere was placed on a motion platform to simulate respiratory movement by setting motion period, frequency, and direction. Respiratory signal was acquired by real-time position management (RPM) method and GE method independently. Target delineation was conducted using the maximum intensity projection (MIP) sequence. The difference between the reconstructed volume and the theoretical moving volume was compared under the two respiratory signal acquisition methods for cube and sphere targets. <b>Results</b> Under the same respiratory signal acquisition method, the same respiratory amplitude, and different respiratory frequencies, reconstructed volume changes were relatively small. For the sphere target, the deviation between the reconstructed volume and the theoretical moving volume was −1.5% to 5.7% with the RPM method and −1.3% to −13.8% with the GE method (both <i>P</i> < 0.05). For the cube target, the deviation between the reconstructed volume and the theoretical moving volume was 0.2% to 0.9% with the RPM method and −2.6% to 0.9% with the GE method, with no statistical significance. <b>Conclusion</b> For small-volume sphere targets, the target volumes obtained from MIP images by the two respiratory signal acquisition methods are both smaller than the actual moving volume. For large-volume cube targets, there is no significant difference between the reconstructed and theoretical results with any respiratory signal acquisition method. The RPM method produces smaller deviation and better image quality when reconstructing small-volume targets.

2.
Cancer Research on Prevention and Treatment ; (12): 453-458, 2022.
Article in Chinese | WPRIM | ID: wpr-986538

ABSTRACT

Objective To investigate the clinical application value of 18F-FDG PET-CT simulation localization in radiotherapy of recurrent abdominal and pelvic tumors. Methods 18F-FDG PET-CT was used to simulate positioning 38 patients with abdominal and pelvic tumors who relapsed after treatment.Based on both CT images and 18F-FDG PRT-CT, we drew up a systemic treatment plan and outlined the radiotherapy target area, and then compared the differences between the two methods. Results In 38 patients, 21.1%(3/8) of patients were found to have distal metastases outside the pelvic and abdominal cavity, and changed the systemic treatment plan.The radiotherapy target was altered in 34(89.5%) patients.The mean value of GTVPET-CT was 118.14cm3and the mean value of GTVCT was 148.53cm3(P=0.044). Conclusion For patients with recurrent abdominal and pelvic tumors, 18F-FDG PET-CT simulation localization treatment improves tumor re-staging, changes the integrated therapy for some patients, and makes the target area of radiotherapy more accurate.

3.
Chinese Journal of Gastrointestinal Surgery ; (12): 173-178, 2021.
Article in Chinese | WPRIM | ID: wpr-942882

ABSTRACT

Objective: Anatomic variations in the perigastric vessels during laparoscopic radical gastrectomy often affect the operator's judgment and prolong the operation time, and even cause accidental injury and surgical complications, and hence the safety and quality of the operation cannot be ensured. In this study, multiple slice CT was reconstructed by 3-dimensional CT simulation software (3D-CT), and 3D-CT images were used to describe the variation of celiac trunk and splenic artery before surgery. The guiding role of the different variation of vessels was analyzed for laparoscopic total gastrectomy+D2 lymph node dissection (LTG+D2LD). Methods: A retrospective cohort study was conducted. Case inclusion criteria: (1) Gastric cancer was at an advanced stage. All the patients were preoperatively examined by digestive endoscopy and 64-row enhanced CT scan, and were histopathologically diagnosed with gastric adenocarcinoma. (2) 3D-CT simulation images were reconstructed to guide the operation. (3) LTG+D2LD surgery was performed by the same surgical team. (4) Clinical data were complete, and all the patients had signed the informed consent. From 2014 to 2018, 98 patients with gastric cancer at the Gastrointestinal Surgery Department of Henan Provincial People's Hospital were enrolled. According to the Adachi classification, celiac trunk variation was divided into common type (Adachi type I) and rare type (Adachi type II-VI). According to the Natsume classification, splenic artery was classified into "flat type" and "curved type". Based on 3D-CT simulation images, variation of celiac trunk and splenic artery was described, and the differences in operation time, intraoperative blood loss and the number of postoperative retrieved lymph nodes were compared between groups with different types of arterial variation. Results: For celiac trunk, common type was found in 84 cases (86%) and rare type was found in 14 cases, including 6 cases (6%) of type II, 2 cases (2%) of type III, 2 cases (2%) of type IV, 3 cases (3%) of type V, 1 case (1%) of type VI. No other types were found. There were no statistically significant differences in clinical characteristics and number of retrieved lymph nodes between patients of the common type group and rare type group (all P>0.05). Compared with common type patients, those of rare type had longer operative time [(321.1±29.0) minutes vs. (295.1±46.5) minutes, t=2.081, P=0.040] and more intraoperative blood loss (median: 66.0 ml vs. 32.0 ml, Z=-4.974, P=0.001). For splenic artery, 41 patients (42%) were flat type and 57 patients (58%) were curved type. There were no statistically significant differences between the two groups in terms of clinical characteristics, intraoperative blood loss, operative time and number of retrieved lymph nodes (all P>0.05). Conclusions: The method of describing the variation in the perigastric vessels by 3D-CT simulation has certain clinical value in laparoscopic radical gastrectomy. The duration of LTG+D2LD is prolonged and the intraoperative blood loss is increased with the variation of celiac trunk, while the variation of splenic artery has no effect on LTG+D2LD.


Subject(s)
Humans , Computer Simulation , Gastrectomy , Gastric Artery/diagnostic imaging , Imaging, Three-Dimensional , Laparoscopy , Lymph Node Excision , Retrospective Studies , Stomach/diagnostic imaging , Stomach Neoplasms/surgery , Tomography, X-Ray Computed
4.
Article | IMSEAR | ID: sea-212128

ABSTRACT

Background: Traditionally pelvic External Beam Radiotherapy is delivered with four field box technique in carcinoma cervix patients. The primary aim of this prospective observational study is to determine the adequacy of pelvic lymph nodal coverage by conventional Four Field Box Technique with the help of pelvic lymph node contouring by CT simulation.Methods: Between January 2013 and August 2015 sixty patients with biopsy proven Carcinoma Cervix were enrolled in this study. Of these fifty-three patients were available for final analysis. CT simulation based Pelvic lymph node contouring was done for each patient. Then two External Beam Radiotherapy plans were generated, one contoured based and the other based on bony landmark based Four Field Box Technique. The number of patients whose contoured lymph nodes lies partly outside the field borders of the bony landmark-based plan and also its extent was determined. D90 of various groups of pelvic lymph nodes obtained from both the plans were compared using ‘paired sample t - test’.Results: It was seen that with Four Field Box Technique there is inadequate coverage of common iliac lymph nodes in 34/53 patients. The difference between the mean D90 of common iliac lymph nodes in two sets of plans was found to be statistically significant.Conclusions: Pelvic field planning should be individualized. CT simulation-based radiotherapy planning should be done for each individual patient to adequately cover the nodal microscopic disease.

5.
Chinese Journal of Radiation Oncology ; (6): 4-8, 2016.
Article in Chinese | WPRIM | ID: wpr-490353

ABSTRACT

Objective To investigate the role of large-diameter magnetic resonance imaging (MRI) simulation in target volume delineation in radiotherapy for nasopharyngeal carcinoma (NPC).Methods Eighteen patients with NPC underwent computed tomography (CT) simulation and MRI simulation scans and localization in the same body position,with SOMATOM Sensation Open 40-row 82-cm large-diameter CT simulator and Siemens 3T MRI MAGNETOM Skyra 70-cm large-diameter simulator,respectively.The gross tumor volume (GTV) and parotid glands were delineated on all images according to the ICRU Report 50/62,and MRI was applied to observe the changes in GTV and parotid volume during radiotherapy.Paired t-test was applied to analyze the differences between GTVCT and GTVMRI and between GTVnx-CT and GTVnx-MRI.Results GTVMRI decreased significantly compared with GTVCT,and the average volume decreased from (213.64±84.59) cm3 to (199.68±84.69) cm3(p=0.006).As for the volume of primary lesions in the nasopharynx,GTVnx-MRI was significantly smaller than GTVnx-CT,and the volume decreased from (95.75± 24.76) cm3 to (88.12±26.25) cm3 (P =0.001);as for the volume of cervical lymph nodes,GTVnd-MRI was significantly smaller than GTVnd-CT,and the volume decreased from (117.89± 72.69) cm3 to (111.56± 70.69) cm3 (P=0.018).The targets delineated by CT and MRI did not overlap completely,with major differences in skull base bone and cervical soft tissue.The volume of both parotid glands delineated on MRI image was higher than that delineated on CT image,with a major difference in the deep lobe.MRI showed that GTV was reduced by 82.64± 16.87% during radiotherapy,and the volumes of the left and right parotid glands were reduced by (32.7± 23.95) % and (34.7± 21.72) %,respectively.Conclusions The delineation of target volume based on MRI simulation is more accurate than that based on CT simulation and can achieve a smaller volume range,which helps to guide target volume delineation in radiotherapy for NPC accurately.

6.
Chinese Journal of Radiation Oncology ; (6): 387-390, 2013.
Article in Chinese | WPRIM | ID: wpr-442014

ABSTRACT

Objective To compare the errors of final isocenter marking method and reference point marking method for CT simulation positioning in intensity-modulated radiotherapy (IMRT).Methods From 2009 to 2012,327 patients with head and neck cancer for IMRT underwent CT simulation positioning using the Philips Brilliance CT Big Bore scanner and Philips Tumor LOC workstation and were divided into final isocenter marking group (n =208) and reference point marking group (n =119) according to positioning methods.Target volume delineation and treatment plan design were performed on the Varian Eclipse treatment planning system (TPS).Before treatment,kilovoltage cone-beam CT scans and registration were performed with the Varian EX on-board imager system to obtain beam position errors in the right-left (RL),superior-inferior (SI),and anterior-posterior (AP) directions,and then comparisons of errors between the two groups were made by independent-samples t test.Finally,the TPS was used to measure the changes in the doses to the organs at risk after moving isocenters in the RL,SI,and AP directions among 5 patients with nasopharyngeal carcinoma.Results The mean beam position errors in the three directions were less in the final isocenter marking group than in the reference point marking group (P =0.02,0.01,0.03).After moving isocenters in the three directions,the target dose was reduced and the dose to the normal tissue around the target tumor was increased significantly.The error in the AP direction had the maximum influence on the spinal cord and brainstem.Conclusions Final isocenter marking method leads to less beam position error than reference point marking method in CT simulation positioning.Small isocenter motion can cause large changes in the doses to the organs at risk.

7.
Chinese Journal of Radiological Medicine and Protection ; (12): 516-518, 2013.
Article in Chinese | WPRIM | ID: wpr-442010

ABSTRACT

Objective To analyze the influence of tumor volume change on intensity modulated radiotherapy(IMRT)for nasopharyngeal carcinoma by analyzing the repeated CT simulation.Methods Twenty nasopharyngeal carcinoma patients undergoing IMRT from July 2011 to November 2012 were selected in the study.The first CT simulation was conducted prior to radiotherapy,and the repeated CT simulation was finished after radiotherapy of 30 Gy.The first and the repeated CT images were fused in treatment planning system and GTV volume shrink rate was calculated.The original plan was used to recalculate the dose distribution on repeated CT.The dose volume histogram was used to calculate the dose difference of organs at risk including the brain stem and spinal cord.Results Compared with the first CT,GTV volume shrink rate of the repeated CT simulation was 28.7%,the maximum dose,1 cm3 volume and the average dose percentage of the brain stem and spinal cord were increased(t=0.83-3.17,P<0.05).Conclusions GTV volume shrinked significantly after radiotherapy of 30 Gy in IMRT for nasopharyngeal carcinoma.The dose of the organs at risk increased accordingly.

8.
Chinese Journal of Radiological Medicine and Protection ; (12): 301-303, 2012.
Article in Chinese | WPRIM | ID: wpr-427089

ABSTRACT

Objective To evaluate the setup errors of image guided radiation therapy (IGRT) for head-and-neck cancer using kilovoltage cone beam CT( kV CBCT).Methods 256 patients with head-and-neck cancer were treated with intensity modulated radiation therapy (IMRT) from March 2009 to October 2011.All patients were immobilized with head-and-neck mask and localized with final isocenter marking method using the Philips PQS CT or Philips Brilliance CT Big Bore scanners,which were equipped with LAP movable laser systems.The CT images were transferred to a Varian Eclipse V8.6 workstation for contouring and planning.A kV cone-beam CT scans was acquired,and registered before the treatment for every patient on a Varian iX linear accelerator via OBI system.The setup errors in the right-left ( RL),superior-inferior (SI),and anterior-posterior (AP) directions were recorded.Results The setup errors for the 473 datasets followed a Gaussian distribution.The systematic errors ± random errors in the RL,SI and AP were(-0.6 ± 1.3 ),(0.5 ± 1.6) and (0.9 ± 1.7 ) mm,respectively.The planning target volume (PTV) margins were calculated respectively as 2.4,2.4 and 3.4 mm according to the formula of M =2.5∑ +0.7δ The margins of 288 sets of data using the Big Bore CT scanner were calculated as 2.0,2.1 and 1.7 mm,respectively.Conclusions The setup errors using final isocenter marking method are smaller than those using reference point marking method.The result derived from this retrospective study could be used to set the margin between CTV and PTV.

9.
Chinese Journal of Radiological Medicine and Protection ; (12): 200-204, 2011.
Article in Chinese | WPRIM | ID: wpr-412726

ABSTRACT

Objecttve To compare the positional and volumetric differences of planning target volumes(PTVs)based on axial three-dimensional CT(3D-CT)and four-dimensional CT(4D-CT)for the primary tumor of non-small cell lung cancer(NSCLC).Methods Sixteen NSCLC patients with lesions located in the upper lobe and 12 patients with lesions in middle and lower lobes,totally 28 patients, initially underwent three-dimensional CT scans followed by 4D-CT scans of the thorax under normal free breathing.PTVvector was defined on gross tumor volume (GTV) contoured on 3D-CT and its motion vector. The clinical target volumes(CTVs)were created by adding 7 mm to GTVs,then, internal target volume (ITVs)were produced by enlarging CTVs isotropically based on the individually measured amount of motion in the 4D-CT,lastly,PTVs were created by adding 3 mm setup margin to ITVs. PTV4D was defined on the fusion of CTVs on all phases of the 4D data.The CTV wag generated by adding7 mm to the GTV on each phase.then,PIVs were produced by fusing CTVs on 10 phases and adding 3 mm setup margin.The position of the target center,the volume of target and the degree of inclusion(DI)were compared reciprocally between the PTVvector and the PTV 4D The difference of the position,volume and degree of inclusion of the targets between PTVvecter and PTV4D were compared,and the relevance between the relative characters of the targets and the three-dimensional vector was analyzed based on the groups of the patients. Results The median of the 3 D motion vector for the lesions in the upper lobe was 2.8 mm, significantly lower than that for the lesions in the middle and lower lobe ( 7.0 mm, z = - 3. 485, P < 0. 05 ). In the upper lobe group there was only significant spatial difference between the PTVvector and PTV4D targets in the center coordinate at the x axe (z = -2. 010, P < 0. 05 ), while in the middle and lower lobes there was only significant spatial difference between the PTVvector and PTV4D targets in the center coordinates at the z axe (z = -2. 136,P <0.05). The median of ratio of PTV4D and PTVvector, of the upper lobe group was 0. 75, significantly higher than that of the middle and lower lobes group (0. 52, z = - 2. 949, P < 0. 05 ).A significant correlation was found for the motion vector and the ratio of PTV and PTV4D in both groups ( r = - 0. 638, - 0. 850, P < 0. 05 ). For all patients, the median of D[ of PTV4D in PTVvector was 66. 39% ,while the median of DI of PTVvector, in PTV4D was 99. 55% , both showed a positive significant correlation with the motion vector (r = -0. 814,0. 613 ,P < 0. 05). Conclusions PTV4D defined based on 4D-CT simulation images is obviously less than PTV defined based on 3D-CT simulation images. The ratio and DI of both targets are related with the three-dimensional motion vector of the tumor.

10.
Korean Journal of Medical Physics ; : 241-246, 2008.
Article in Korean | WPRIM | ID: wpr-93135

ABSTRACT

Patient's respiration can have an effect on movement of tumor range and peripheral organs. Therefore, the respiratory signal was acquired by relation between external markers and movement of patient's abdomen during radiational therapy in order to minimize the effect of respiration. Based on this technique, many studies of rational therapy to irradiate at particular part of stable respiratory signals have executed and they have been clinically applied. Nevertheless, the phase-based method is preferred to the amplitude-based method for the rational therapy related to respiration. Because stabilization of the respiratory signal are limited. In this study, a in-house respiratory signal analysis program was developed for the phase reassignment and the analysis of the irregular respiratory signals. Various irregular respiratory patterns was obtained from clinical experimental volunteers. After then, the in-house program analyzed the factors affecting to phase assignment which is directly related to irradiated sector. Subsequently, accuracy of phase assignment was improved with removement of irregular signals by self-developed algorithm. This study is considered to be useful for not only image reconstruction and elevation of irradiating accuracy through phase assignment of RPM system but also analysis of respiratory signals. Moreover, development of 4D CT image is planed with phantom researches or clinical experiments based on this program.


Subject(s)
Abdomen , Four-Dimensional Computed Tomography , Image Processing, Computer-Assisted , Respiration
11.
Korean Journal of Medical Physics ; : 263-268, 2008.
Article in Korean | WPRIM | ID: wpr-93132

ABSTRACT

The application of a respiratory gated radiotherpy method to the lung radiation surgery was evaluated compared with the conventional method in which the whole tumor motion range is considered in the delineation of PTV (Planning target volume). The four dimensional CT simulation images were acquired for the five NSCLC (Non-small cell lung cancer) patients for radiation surgery. The respiratory gated plan was prepared with the 50% phase CT images and the conventional method was planned based on the ITV (Internal target volume) which include all the target volumes created in each phase CT images within a whole respiratory period. The DVH (Dose volume histogram) of OAR (Organ at risk) which calculated in each method was compared for the evaluation of the plan properness. The relative decrease of OARs' DVH were verified in the application of respiratory gated method. The average decrease rate were 16.88+/-9.97% in the bronchus, 34.13+/-19.15% in the spinal cord, 28.42+/-18.49% in the chest wall and 32.48+/-16.66% in the lung. Based on these results, we can verified the applicability and the effectiveness of the respiratory gated method in the lung radiation surgery.


Subject(s)
Humans , Bronchi , Four-Dimensional Computed Tomography , Lung , Spinal Cord , Thoracic Wall
12.
Chinese Journal of Radiation Oncology ; (6)2005.
Article in Chinese | WPRIM | ID: wpr-679522

ABSTRACT

Objective Transpherical technique of CT scanner of beekley spot quality assurance (BBQA) and its effect in CT simulator QA.Methods Vertical column,BB,Jig,Philips PQS-Falcon CT, ACQSIM workstation and the laser system were used.Scanning BB was used in sending image to the AC- QSIM workstation.In this system,after describing the BB,isocenter can be established.Then,tile couch with the lasers were moved to the programmed position.Checking was needed.Results The center of the laser should just be found on the BB.Otherwise the laser system should be regulated again.Conclusions Beekley spot quality assurance,being the very important center of any QA program,influences the accuracy of quality of the treatment.

13.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 94-99, 2003.
Article in Korean | WPRIM | ID: wpr-200730

ABSTRACT

PURPOSE: To explore a 3D conformal radiotherapy technique for a posterior fossa boost, and the potential advantages of a prone position for such radiotherapy. MATERIALS AND METHODS: A CT simulator and 3D conformal radiotherapy planning system was used for the posterior fossa boost treatment of a 13-year-old medulloblastoma patient. He was placed in the prone position and immobilized with an aquaplast mask and immobilization mold. CT scans were obtained of the brain from the top of the skull to the lower neck, with IV contrast enhancement. The target volume and normal structures were delineated on each slice, with treatment planning performed using non-coplanar conformal beams. RESULTS: The CT scans, and treatment in the prone position, were performed successfully. In the prone position, the definition of the target volume was made easier due to the well enhanced tentorium. In addition, the posterior fossa was located anteriorly, and with the greater choice of beam arrangements, more accurate treatment planning was possible as the primary beams were not obstructed by the treatment table. CONCLUSION: A posterior fossa boost, in the prone position, is feasible in cooperating patients, but further evaluation is needed to define the optimal and most comfortable treatment positions.


Subject(s)
Adolescent , Humans , Brain , Carboxymethylcellulose Sodium , Fungi , Head , Immobilization , Masks , Medulloblastoma , Neck , Prone Position , Radiotherapy , Radiotherapy, Conformal , Skull , Tomography, X-Ray Computed
14.
Chinese Journal of Radiation Oncology ; (6)1993.
Article in Chinese | WPRIM | ID: wpr-553155

ABSTRACT

Objective To compare and evaluate dose at optic structures (eyeballs, optic nerves and chiasma) between conventional and CT simulated treatment planning for nasopharyngeal carcinoma. Methods Thirty three patients with T1 to T4 nasopharyngeal carcinoma underwent simulated spiral CT with picker PQ 5000 and AcQ plan 4.1.1 software system. At first irradiation portals were delinated by the simulation films taken on the conventional X ray simulator using the digital reconstruction (DRR) of the treatment planning system (TPS) supplemented by the patient's CT (or MRI) and clinical findings. Then, the gross tumor volume (GTV),clinical target volume (CTV) and planned target volume (PTV) were delineated on every section of the CT scans. At the same time, the silhouette of the nearby important organs was drawn out ,paying special attention to the backward passage of the retrobulbar optic nerves up to the optic chiasma. The final portals were designed by the 3 dimensional relation between the tumor and its surrounding organs. Then dose distribution was separately calculated by two independent TPSs,with 100% at the target center. Finally,the maximum dose (D max ),average dose (D ave ) and median dose (D med ) of the tumor target area, eye ball,optic nerve and also the length of optic nerve included within the portal of these two technics were compared.Results The dose distribution in nasopharyngeal GTV and CTV were satisfactory both in CT simulated and conventional planning. However, the D max ,D ave and D med all showed significant differences. Those by CT simulated planning were obviously lower than those by conventional planning. CT simulated planning was able to spare more optic nerve by leaving it out of the irradiation portal,thereby,avoiding unwanted radiation.Conclusion CT simulated treatment planning is able to reduce the superfluous radiation to the optic nerve in external irradiation of nasophargngeal carcinoma.

15.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-588361

ABSTRACT

CT laser simulation positioning system is a necessary auxiliary device for radiotherapy. Its main purpose is to position patients by simulating different kinds of treatment machine. In order to demarcate the mark of the iso-center, it is common to use the laser positioning device to indicate the iso-center. The kernel technology of the laser positioning system is the controlling of the step progress motor by using the MCS, which is to control the movement of step progress motor using the wheel of the motor. This design uses MCS-51 to control step progress motor by the way of exporting the rectangle wave form through I/O port of 8255 chip. The system configuration is simple, the operation is convenient and the positioning is precise.

SELECTION OF CITATIONS
SEARCH DETAIL