1.
Journal of the Korean Society of Neonatology ; : 85-89, 1999.
Article in Korean | WPRIM | ID: wpr-125232

ABSTRACT

PURPOSE: Bilirubin values may vary depending on the site of sampling. The purpose of this study is to compare simultaneously obtained capillary and venous serum bilirubin to assess neonatal jaundice. METHODS: The subjects for the study included 135 healthy inborn as well as outborn full-term infants admitted to Dong-Eui Medical Center for evaluation of jaundice from May 1997 to February 1999. A paired capillary and venous sample was simultaneously drawn from each neonate, and their serum bilirubins were measured by direct spectrophotometric method. RESULTS: A high correlation between capillary and venous serum bilirubin(correlation coefficient(r) =0.949, P0.05), however, the mean venous bilirubin was significantly higher than the mean capillary bilirubin(mean difference;0.65+/-1.04 mg/dL, P0.05). CONCLUSION: There was a trend toward venous bilirubin being higher than capillary bilirubin at higher serum bilirubin levels. However, further studies are needed to ascer-tain the relationship between the site of the sampling and methodology in measurement of bilirubin.


Subject(s)
Humans , Infant , Infant, Newborn , Bilirubin , Capillaries , Jaundice , Jaundice, Neonatal
SELECTION OF CITATIONS