1.
Korean Journal of Radiology ; : 102-113, 2019.
Article in English | WPRIM | ID: wpr-719593

ABSTRACT

OBJECTIVE: To assess the accuracy and potential bias of computed tomography (CT) ventricular volumetry using semiautomatic three-dimensional (3D) threshold-based segmentation in repaired tetralogy of Fallot, and to compare them to those of two-dimensional (2D) magnetic resonance imaging (MRI). MATERIALS AND METHODS: This retrospective study evaluated 32 patients with repaired tetralogy of Fallot who had undergone both cardiac CT and MRI within 3 years. For ventricular volumetry, semiautomatic 3D threshold-based segmentation was used in CT, while a manual simplified contouring 2D method was used in MRI. The indexed ventricular volumes were compared between CT and MRI. The indexed ventricular stroke volumes were compared with the indexed arterial stroke volumes measured using phase-contrast MRI. The mean differences and degrees of agreement in the indexed ventricular and stroke volumes were evaluated using Bland-Altman analysis. RESULTS: The indexed end-systolic (ES) volumes showed no significant difference between CT and MRI (p > 0.05), while the indexed end-diastolic (ED) volumes were significantly larger on CT than on MRI (93.6 ± 17.5 mL/m² vs. 87.3 ± 15.5 mL/m² for the left ventricle [p < 0.001] and 177.2 ± 39.5 mL/m² vs. 161.7 ± 33.1 mL/m² for the right ventricle [p < 0.001], respectively). The mean differences between CT and MRI were smaller for the indexed ES volumes (2.0–2.5 mL/m²) than for the indexed ED volumes (6.3–15.5 mL/m²). CT overestimated the stroke volumes by 14–16%. With phase-contrast MRI as a reference, CT (7.2–14.3 mL/m²) showed greater mean differences in the indexed stroke volumes than did MRI (0.8–3.3 mL/m²; p < 0.005). CONCLUSION: Compared to 2D MRI, CT ventricular volumetry using semiautomatic 3D threshold-based segmentation provides comparable ES volumes, but overestimates the ED and stroke volumes in patients with repaired tetralogy of Fallot.


Subject(s)
Humans , Bias , Heart Defects, Congenital , Heart Ventricles , Magnetic Resonance Imaging , Methods , Retrospective Studies , Stroke Volume , Tetralogy of Fallot
2.
Korean Journal of Radiology ; : 704-714, 2018.
Article in English | WPRIM | ID: wpr-716265

ABSTRACT

OBJECTIVE: To test whether the method utilizing three-dimensional (3D) whole-heart MRI has an additional benefit over that utilizing conventional two-dimensional (2D) cine MRI in quantifying ventricular volumes. MATERIALS AND METHODS: In 110 patients with congenital heart disease, a navigator-gated, 3D whole-heart MRI during end-systole (ES) and end-diastole (ED), 2D short-axis cine MRI, and phase contrast MRI of the great arteries were acquired. Ventricular volumes were measured by using a 3D threshold-based segmentation for 3D whole-heart MRI and by using a simplified contouring for 2D cine MRI. The cardiac trigger delays of 3D whole-heart MRI were compared with those of a 2D cine MRI. The stroke volumes calculated from the ventricular volumes were compared with the arterial flow volumes, measured by phase contrast MRI. RESULTS: The ES and ED trigger delays of whole-heart MRI were significantly less than cine MRI for both the left ventricle (−16.8 ± 35.9 ms for ES, −59.0 ± 90.4 ms for ED; p < 0.001) and the right ventricle (−58.8 ± 30.6 ms for ES, −104.9 ± 92.7 ms for ED; p < 0.001). Compared with the arterial flow volumes, 2D cine MRI significantly overestimated the left ventricular stroke volumes (8.7 ± 8.9 mL, p < 0.001) and the 3D whole-heart MRI significantly underestimated the right ventricular stroke volumes (−22.7 ± 22.9 mL, p < 0.001). CONCLUSION: Three-dimensional whole-heart MRI is often subject to early timing of the ED phase, potentially leading to the underestimation of the right ventricular stroke volumes.


Subject(s)
Humans , Arteries , Heart Defects, Congenital , Heart Ventricles , Magnetic Resonance Imaging , Magnetic Resonance Imaging, Cine , Methods , Stroke Volume